If something has to be monitored: A relay for every application. simirel

Similar documents
One range for every application Monitoring and controlling with SIRIUS Relays. sirius

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

3RP, 7PV Timing Relays

Monitoring, Controlling and Switching with SIRIUS Relays. One range for every application. siemens.com/relays

The complete universe of Industrial Controls. You have it at your fingertips. sirius

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

sirius Switching. Protecting. Starting. SIRIUS Product Overview

SIRIUS 3RB2 Solid-State Overload Relays

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

Siemens AG SIMOCODE 3UF Motor Management and

IEC Power Control Contactors and Contactor Assemblies

Relays. SIRIUS 3RR24 Monitoring Relays for Mounting onto 3RT2 Contactors for IO-Link. Current and active current monitoring. 10/80 Siemens IC

3RA13, 3RA14 Contactor Assemblies

Simply on. Simply off. Day and Night. sirius SWITCHING

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

Solid-State Switching Devices

Solid-State Switching Devices

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

SIMOCODE 3UF Motor Management and Control Devices

Contactors and Contactor Assemblies

Siemens.com/industrial-controls

Monitoring Relays. 3UG Monitoring Relays for Electrical and Additional Measurements. Line monitoring 7/61. Overview

SIRIUS Motor Management and Control Devices

Siemens AG up to 12 up to 25 up to 50 up to 100 up to 200 up to S12 Terminal brackets for stand-alone

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

IEC Contactors. Auxiliary Contact Blocks GENERAL

3RV1 Circuit-Breakers

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.

Contactors and Contactor Assemblies

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Contact protection relay

Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

MID approval no. DE-08-MI004-PTB004 Date of release

Solid-State Contactors

Parts List, Charging Chart, Wiring Diagrams

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

Protection Equipment

3RT, 3TB, 3TF Contactors for Switching Motors

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Switching Devices 7/1. 7/4 Product overview. 7/5 5TT5 remote control switches. 7/8 5TT3 0 switching relays. 7/9 5TT5 7 Insta contactors

Switching and controlling in the switch cabinet

IEC Power Control Overload Relays

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Q9 ASD LOW VOLTAGE DRIVE

SITOP in the SIMATIC Design

Solid State Remote Power Controller E /627

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Industrial Controls Product Catalog 2017

Electrical Components for the Railway Industry. SIRIUS Relays 3RP, 3RS, 3TX

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

IEC Power Control Overload Relays

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

SOFT STARTERS PLANET -LOGIC

ISOMETER isopv with coupling device AGH-PV

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A)

Signal Doublers. VariTrans A 20300

SIRIUS Monitoring and Controlling. Overview of safety relays. Safety Integrated. Answers for industry.

Control Transformers Control transformers

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

Measuring and Monitoring Relays

Motor protection relays

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Miniature Circuit-Breaker IEC Series 8562

Contactors and Contactor Assemblies

SIRIUS modular system

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Expansion Module HZS 541-1S

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

Circuit Breaker Analyzer & Timer CAT65

Circuit Breaker Analyzer & Timer CAT126

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Operating instructions. Speed monitor D / / 2014

Siemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry.

Load Feeders and Motor Starters for Use in the Control Cabinet

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

CS8 Industrial Control Relays

Room Temperature Controllers

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

SITOP PSU8600 power supply system

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Transcription:

If something has to be monitored: A relay for every application simirel

Time Relays Time Relays 3RP15/3RP20 for snapping onto mounting rails 4/5 7PV for front-panel mounting, digital 6/7 Temperature Monitoring Relays 3RS10/3RS11 with analog settings 8/9 Monitoring Relays 3RS10/3RS11 with digital settings 10/11 Thermistor Motor Protection 3RN1 12/13 Line Monitoring Relays 3UG3 monitoring relays for voltage, line and insulation 14/15 Load Monitoring Relays 3UG3 for single-phase current and cos ϕ monitoring 16/17 Other Monitoring Relays 3UG3 monitoring relays for level and speed 18/19 Interface Relays 3TX70 interface relays 20/21 Narrow design 3TX70 semiconductor interfaces 22/23 Interface Relays and Converters 3RS18 relay interfaces 24 Plug-In Relays LZX plug-in relays complete units 25/26 LZX plug-in relays individual modules 27 Converters 3RS17 interface converters, normalized signal and universal converters 28/29 Power Relays/ 3TG10 30/31 Power Supply SITOP Power 30/31

The Large Range of Relays: A wealth to choose from You re unlikely to find a more complete, more extensive family of relays on the market than SIMIREL. From function relays through thermistor motor protection up to converters: SIMIREL has them all. Whatever your needs. This is because SIMIREL has the most extensive range of relays in the whole market. SIMIREL offers you everything that is used between the motor feeder and automation and that from a single source. For example, time, monitoring and temperature relays. You need a switching relay? Take a look at our plug-in power and interface relays and you will come up with a winner. We also have a complete range of interface converters from which you can choose. No matter what kind of relay you re looking for SIMIREL always has the answer. And the big advantage is the fact that every one of our relays is extremely easy to use. Just take a look at our range we think you ll be surprised. SIMIREL - Relays for every application The highlights at a glance: Optimum for every application: Extensive range User-friendly: Extremely easy to use Multi-functional: Can be flexibly used Practical: Graduated for the performance you need Excellent price-performance comparison Everything switched to go: With SIMIREL time, monitoring and interface relays, everything runs smoothly. Whether in production or transport, whether monitoring motors or controlling complex plants and systems our relays have everything under control from the word go. 3

3RP15/3RP20 Time Relays for snapping onto mounting rails 3RP1/3RP2 electronic time relays are used in all types of control, starting and protective circuits for all switching operations involving time delays. Thanks to their well thought-out compact design, they are the ideal timer blocks for cabinet and panel builders and control manufacturers in all industry sectors. Your advantages: All relay versions are available with the innovative spring-loaded terminal connection Labels document the function which has been set at the multi-function time relay Transparent range for every application: Only seven basic devices Clear logistical advantages using multi-function time relays with wide-range voltage Optimum price-performance ratio Positively driven, hard-gold-plated relay contacts (among other things for safety circuits up to Category 2 according to DIN EN 954-1, optionally in conjunction with electronic controls) Sealable cover to secure parameters which have been set Engineering information and instructions: For the clock-pulse function, pulse and interval can be separately set for the flashing function: Pulse/interval ratio is 1:1 The time addition function (this has no holding on supply failure function) for multi-function relays: By activating the start contact Applications: ON delay: Noise pulses are suppressed Motors can be started in stages so that the line supply is not overloaded etc. OFF delay: To generate a run-on function after the control voltage has been withdrawn (fan run-on) Emergency shutdown or to bring a plant into a defined state although the power has failed Star/delta: Motors are changed-over from star to delta with a changeover interval of 50 ms in order to prevent a short circuit between phases 4

3RP1/3RP2 time relays 3RP20 solid-state time relays in a 45 mm SIRIUS design Function Contact elements Time range 8 functions (changeover contact) 8 functions ON delay ON delay 16 functions 3RP1/3RP2 time relays 3RP15 solid-state time relays in a 22.5 mm ruggedized 8 functions 8 functions 8 functions 8 functions 8 functions 2 CO 16 functions 2 CO 16 functions 2 CO 16 functions 2 CO 16 functions 2 CO ON delay 0.5 10 s ON delay 0.5 10 s ON delay 1.5 30 s ON delay 1.5 30 s ON delay 5 100 s ON delay 5 100 s ON delay ON delay ON delay 2 CO ON delay 2 CO ON delay 2 CO ON delay 2 CO ON delay, 2-wire 1 NO, semiconductor 0.05 240 s ON delay, 2-wire 1 NO, semiconductor 0.05 240 s OFF delay with auxiliary voltage 0.5 10 s OFF delay with auxiliary voltage 0.5 10 s OFF delay with auxiliary voltage 1.5 30 s OFF delay with auxiliary voltage 1.5 30 s OFF delay with auxiliary voltage 5 100 s OFF delay with auxiliary voltage 5 100 s OFF delay with auxiliary voltage 0.05 100 s OFF delay with auxiliary voltage 0.05 100 s OFF delay with auxiliary voltage 0.05 100 s OFF delay with auxiliary voltage 2 CO 0.05 100 s OFF delay with auxiliary voltage 2 CO 0.05 100 s OFF delay with auxiliary voltage 2 CO 0.05 100 s Clock generator Clock generator Clock generator Star/delta with run-on function 3 x 1 NO 1 20 s, 30 600 s (run-on) Star/delta with run-on function 3 x 1 NO 1 20 s, 30 600 s (run-on) Star/delta 1 NO + 1 NO 1 20 s Star/delta 1 NO + 1 NO 1 20 s Star/delta 1 NO + 1 NO 3 60 s Star/delta 1 NO + 1 NO 3 60 s Control supply voltage 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 240 V UC 12 V DC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 240 V UC 24 240 V UC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 240 V UC 400 440 V AC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 42 48/60 V UC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 240 V UC 24 66 V UC 90 240 V UC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 V UC 100 127 V UC 200 240 V UC 24 V UC 100 127 V UC 200 240 V UC 42 48/60 V UC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 V UC/100 127 V AC 24 V UC/200 240 V AC 24 V UC/100 127 V AC 24 V UC/200 240 V AC Order No. 3RP2005- AQ30 3RP2005- AP30 3RP2025- AQ30 3RP2025- AP30 3RP2005- BW30 3RP1505- AA40 3RP1505- AQ30 3RP1505- AP30 3RP1505- AW30 3RP1505- RW30 1) 3RP1505- BQ30 3RP1505- BP30 3RP1505- BW30 3RP1505-1BT20 2) 3RP1511- AQ30 3RP1511- AP30 3RP1512- AQ30 3RP1512- AP30 3RP1513- AQ30 3RP1513- AP30 3RP1525- AQ30 3RP1525- AP30 3RP1525- BR30 3RP1525- BQ30 3RP1525- BP30 3RP1525- BW30 3RP1527- EC30 3RP1527- EM30 3RP1531- AQ30 3AP1531- AP30 3RP1532- AQ30 3RP1532- AP30 3RP1533- AQ30 3RP1533- AP30 3RP1540- AB30 3RP1540- AJ30 3RP1540- AN30 3RP1540- BB30 3RP1540- BJ30 3RP1540- BN30 3RP1555- AR30 3RP1555- AQ30 3RP1555- AP30 3RP1560- SQ30 3RP1560- SP30 3RP1574- NQ30 3RP1574- NP30 3RP1576- NQ30 3RP1576- NP30 Time Relays 1) Positively driven and hard-gold-plated relay contacts 2) This device is only available with screw terminal 1 = screw terminal 2 = spring-loaded terminal 5

7PV Time Relays for front panel mounting with digital settings The 7PV solid-state time relay is ideal for mounting in operator panels. It is 48 x 48 mm for mounting in a 45 x 45 mm cut-out which means that this device is the optimum relay for every application when it comes to function, rated voltage and time ranges. The relay has selectable time ranges so that it covers a wide spectrum of applications with all of the usual control supply voltages. Digital devices are set using the keypad and the LCD displays. The version can be combined with an 11-pin plug-in socket either for surface mounting (mounting rail) or connection at the rear. The relays can be quickly replaced and can be used over a wide ambient temperature range of between 20 C and 60 C. Your advantages: Quickly accessible and easy to read thanks to the front-panel mounting A small 48 x 48 mm Multi-function relays with digital settings with LCD display and holding on supply failure function Time ranges of 0.01 s to 9999 h can be selected Can be easily handled with simple menu prompting Can be quickly replaced using separate components, plug socket and relay Applications: When process materials frequently change When the plant or system is frequently modified Everywhere where start and process times must be frequently adapted (e. g. when plastic bags with changing material thickness are welded) 6

7PV time relays Built-in time relays with digital settings Multi-function, 6 functions: ON delay OFF delay with auxiliary voltage Blinking, pulse-starting Blinking, interval-starting Making pulse contact Pulse shaping 1 changeover contact LCD display 0.01 s 9999 h, eleven possible settings 24 V UC/110 240 V AC 7PV3 solid-state time relays, digital settings Function Contact elements Time range Control supply voltage Order No. (MRPD) 6 functions 0.01 s 9999 h 24 V UC/110 240 V AC 7PV3348-2AX34 Time Relays Accessories Version 11-pin plug-in socket with rear connection 11-pin plug-in socket for DIN mounting rail and surface mounting Order No. 7PX9921 LZX:MT78750 7

3RS10/3RS11 Temperature Monitoring Relays Relays with analog settings Our 3RS10/3RS11 analog temperature monitoring relays are the specialists when it comes to measuring temperatures in solid, liquid and gaseous mediums. A sensor in the medium is used to determine the temperature. This is then evaluated by the device and monitored whether the measured value was within the range defined by the limit temperatures. Depending on how it is parameterized, the output relay either switches on or off at the threshold values. Your advantages: All of the versions are also available with innovative spring-loaded terminals All of the relays have electrical isolation exception: 24 V UC Can be simply handled using a rotary potentiometer Selectable hysteresis For devices with two threshold values, the operating principle can be selected Applications: Motor and plant protection Cabinet temperature monitoring Frost monitoring Temperature limits for process quantities, e. g. in the packaging industry or electroplating Controlling systems and machines such as heating, climate control and ventilation systems, solar collectors, heat pumps and warm water supplies Monitoring bearing and gearbox oil Monitoring cooling liquids 8

3RS10/3RS11 temperature monitoring relays Sensor Function Measuring range Rated control supply Screw terminal spring-loaded terminal voltage Vs 50 60 Hz AC Order No. Order No. C V Analog settings, 1 threshold value, 22.5 mm wide; analog closed-circuit principle; without fault memory; 1 NO + 1 NC PT100 Over- 50...+50 24 V UC 3RS10 00-1CD00 3RS10 00-2CD00 (resistance temperature 110/230 V AC 3RS10 00-1CK00 3RS10 00-2CK00 sensor) 0...+100 24 V UC 3RS10 00-1CD10 3RS10 00-2CD10 110/230 V AC 3RS10 00-1CK10 3RS10 00-2CK10 0...+200 24 V UC 3RS10 00-1CD20 3RS10 00-2CD20 110/230 V AC 3RS10 00-1CK20 3RS10 00-2CK20 Under- 50...+50 24 V UC 3RS10 10-1CD00 3RS10 10-2CD00 temperature 110/230 V AC 3RS10 10-1CK00 3RS10 10-2CK00 0...+100 24 V UC 3RS10 10-1CD10 3RS10 10-2CD10 110/230 V AC 3RS10 10-1CK10 3RS10 10-2CK10 0...+200 24 V UC 3RS10 10-1CD20 3RS10 10-2CD20 110/230 V AC 3RS10 10-1CK20 3RS10 10-2CK20 Type J Over-0...+200 24 V UC 3RS11 00-1CD20 3RS11 00-2CD20 (thermo-temperature 110/230 V AC 3RS11 00-1CK20 3RS11 00-2CK20 element) 0...+600 24 V UC 3RS11 00-1CD30 3RS11 00-2CD30 110/230 V AC 3RS11 00-1CK30 3RS11 00-2CK30 Type K Over-0...+200 24 V UC 3RS11 01-1CD20 3RS11 01-2CD20 (thermo-temperature 110/230 V AC 3RS11 01-1CK20 3RS11 01-2CK20 element) 0...+600 24 V UC 3RS11 01-1CD30 3RS11 01-2CD30 Monitoring Relays 110/230 V AC 3RS11 01-1CK30 3RS11 01-2CK30 +500...+1000 24 V UC 3RS11 01-1CD40 3RS11 01-2CD40 110/230 V AC 3RS11 01-1CK40 3RS11 01-2CK40 Analog settings for alarm and trip (2 threshold values), 22.5 mm wide; open-/closed-circuit principle, selectable; without fault memory; 1 NO + PT100 Over- 50...+50 24 V UC 3RS10 20-1DD00 3RS10 20-2DD00 (resistance temperature 24 240 V UC 3RS10 20-1DW00 3RS10 20-2DW00 sensor) 0...+100 24 V UC 3RS10 20-1DD10 3RS10 20-2DD10 24 240 V UC 3RS10 20-1DW10 3RS10 20-2DW10 0...+200 24 V UC 3RS10 20-1DD20 3RS10 20-2DD20 24 240 V UC 3RS10 20-1DW20 3RS10 20-2DW20 Under- 50...+50 24 V UC 3RS10 30-1DD00 3RS10 30-2DD00 temperature 24 240 V UC 3RS10 30-1DW00 3RS10 30-2DW00 0...+100 24 V UC 3RS10 30-1DD10 3RS10 30-2DD10 24 240 V UC 3RS10 30-1DW10 3RS10 30-2DW10 0...+ 200 24 V UC 3RS10 30-1DD20 3RS10 30-2DD20 24 240 V UC 3RS10 30-1DW20 3RS10 30-2DW20 Type J Over-0...+200 24 V UC 3RS11 20-1DD20 3RS11 20-2DD20 (thermo-stemperature 24 240 V UC 3RS11 20-1DW20 3RS11 20-2DW20 element) 0...+600 24 V UC 3RS11 20-1DD30 3RS11 20-2DD30 24 240 V UC 3RS11 20-1DW30 3RS11 20-2DW30 Type K Over-0...+200 24 V UC 3RS11 21-1DD20 3RS11 21-2DD20 (thermo-temperature 24 240 V UC 3RS11 21-1DW20 3RS11 21-2DW20 element) 0...+600 24 V UC 3RS11 21-1DD30 3RS11 21-2DD30 24 240 V UC 3RS11 21-1DW30 3RS11 21-2DW30 +500...+1000 24 V UC 3RS11 21-1DD40 3RS11 21-2DD40 24 240 V UC 3RS11 21-1DW40 3RS11 21-2DW40 Evaluation devices with analog settings with one and two threshold values. For relays with analog settings, the threshold values and the hysteresis of 2 to 20 % are set using rotary potentiometers. For relays with 2 threshold values, the adjustable hysteresis only acts on the 1st threshold value. A fixed hysteresis of 5 % acts on the 2nd threshold value. This product series was developed for applications where a setting accuracy of ±5 % is sufficient. 9

3RS10/3RS11 Temperature Monitoring Relays Relays with digital settings These relays are used to measure temperatures in solid, liquid and gaseous mediums. These relays also monitor temperatures to see whether they fall within a specific operating range (window function). This means that 3RS10 40 and 3RS11 40 relays fulfill requirements in compliance with DIN 3440 as temperature monitor. The 3RS10 42 and 3RS11 42 relays can be used as temperature limiting devices in accordance with DIN 3440. These represent a good alternative to temperature controllers in the low-end area. Your advantages: Simple to handle without complex menu prompting Certified according to DIN 3440 All of the relay versions are also available with innovative spring-loaded terminals 2- or 3-point control which can be quickly parameterized Applications: Plant and environmental protection Temperature limits for process quantities e. g. in the packaging industry or electroplating Temperature limits for heating systems Exhaust gas temperature monitoring Controlling plants and machines such as heating, climate control and ventilation systems, solar collectors, heat pumps and warm water supplies Monitoring motor, bearing and gearbox oil temperatures Monitoring the temperature of cooling liquids The short-circuit and wire breakage detection as well as the measuring range are, dependent on the sensor type, restricted: Measuring range in C for thermoelements Sensor Short Wire 3RS11 40 3RS11 42 type circuit breakage measuring measuring range in C range in C J x 99...999 99...1200 K x 99...999 99...1350 T x 99...400 99...400 E x 99...999 99...999 N x 99...999 99...999 S x 0...1750 R x 0...1750 B x 400...1800 Measuring range in C for resistance sensors Sensor Short Wire 3RS10 40 3RS10 42 type circuit breakage measuring measuring range in C range in C PT100 x x 50...500 50...750 PT1000 x x 50...500 50...500 KTY83-110 x x 50...175 50...175 KTY84 x x 40...300 40...300 NTC 1) x 80...160 80...160 10 1) NTC type: B57227-K333-A1 (100 C: 1.8 kω; 25 C: 32.762 kω)

3RS10/3RS11 temperature monitoring relays Sensor Measuring range Rated control supply Screw terminal spring-loaded terminal (measuring range voltage Vs limit depends on 50 60 Hz AC the sensor) C V Order No. Order No. Temperature monitor acc. to DIN 3440, digital settings, 2 threshold values, 45 mm wide; + + 1 NO, fault memory function possible using an external jumper. Relay parameters have a holding on supply failure function. PT100/1000; 50...+500 24 V UC 3RS10 40-1GD50 3RS10 40-2GD50 KTY83/84; 24 240 V UC 3RS10 40-1GW50 3RS10 40-2GW50 NTC (resistance sensor) 1) Type J, K, T, 99...+999 24 V UC 3RS11 40-1GD60 3RS11 40-2GD60 E, N (thermoelement) 24 240 V UC 3RS11 40-1GW60 3RS11 40-2GW60 Temperature limiter and Temperature monitor according to DIN 3440, digital settings, 2 threshold values, 45 mm wide; + + 1 NO, tripped state and relay parameters have a holding on supply failure function. PT100/1000; 50...+750 24 V UC 3RS10 42-1GD70 3RS10 42-2GD70 KTY83/84; 24 240 V UC 3RS10 42-1GW70 3RS10 42-2GW70 NTC (resistance sensor) 1) Type J, K, T, E, 99...+1800 24 V UC 3RS11 42-1GD80 3RS11 42-2GD80 N, R, S, B 24 240 V UC 3RS11 42-1GW80 3RS11 42-2GW80 (thermoelement) Sensor Number of Measuring range Rated control supply Screw terminal spring-loaded terminal sensors voltage Vs C V Order No. Order No. Monitoring Relays Motor monitoring relays, digital settings for up to 3 sensors, 45 mm wide; + + 1 NC PT100/1000; 1 to 3 50...+ 500 24 240 V UC 3RS10 41-1GW50 3RS10 41-2GW50 KTY83/84; sensor NTC (resistance sensor) 1) 1) NTC type: B57227-K333-A1 (100 C: 1.8 kω; 25 C: 32.762 kω) Relays with digital settings Temperature monitoring relays distinguish themselves due to the fact that they are extremely easy to handle. The actual temperature is always displayed on the three-digit LED display. A dedicated relay with one NO contact is integrated to monitor the sensor. The relay is switched out in the parameterizing mode. The following parameters can be set: Sensor type 2 threshold values, ϑ 1 ϑ 2 1 hysteresis; this acts on both thresholds (0 99 K) 1 delay time; this acts on both thresholds (0 99 K) Open-circuit/closed-circuit principle can be selected Function: Overtemperature/undertemperature or within a defined range Versions with wide-range voltage have electrical isolation. The temperature ranges are dependent on the sensor type (refer to the function). Characteristics of the most important resistance temperature sensors 5500 5000 NTC 4500 4000 Resistance in Ohm 3500 3000 2500 2000 1500 KTY83 KTY84 PT1000 1000 500 PT100 0 100 50 0 50 100 150 200 250 300 350 400 450 500 550 Temperature in C 11

3RN1 Thermistor Motor Protection 3RN1 thermistor motor protection relays provide decisive advantages where currentdependent protection using either a circuit-breaker or an overload relay is not the ideal monitoring quantity: In specific cases, often caused by external defects, overheating can occur without this being able to be detected by the thermal image in the circuitbreaker or an overload relay. Examples include heavy-duty starting (e. g. centrifuges), operation with AC drive converters or frequent switching, braking operations or when cooling is restricted, e. g. due to accumulated dirt. Your advantages: The motor winding temperature is directly measured Only one relay is required for all motor power ratings Device/terminal labeling acc. to DIN EN 50005 for standard switching relays and for overload protective devices Relays with hard-gold-plated contacts for use under difficult conditions LEDs indicate wire breakage and short circuit in the sensor circuit All relay versions are alternatively equipped with screw or spring-loaded terminals Version with protective separation up to 300 V acc. to DIN/VDE 0106 as well as versions with bistable relay for special applications PTB 01 ATEX certification Applications: Alarm and trip function by using two sensor circuits with different response temperatures this means that it is possible to respond before shutting down (for example, additional cooling can be switched-in, the load reduced, etc.) Multi-motor protection using only one device, e. g. for conveyor lines for several motors which must be shut down together 12

Thermistor motor protection relays for PTC thermistors (type A PTCs) All devices with the exception of 24 V UC have electrical isolation Version Reset Switching contacts Control supply Order No. (MRPD) voltage Compact evaluation units, 22.5 mm wide, monostable, closed-circuit current principle, 1 LED Terminal A1 is connected to the Auto 24 V UC 3RN1000- AB00 common of the changeover contact 110 V AC 3RN1000- AG00 230 V AC 3RN1000- AM00 Standard evaluation units, 22.5 mm wide, monostable, closed-circuit current principle, 2 LEDs Auto 1 NO + 1 NC 24 V UC 3RN1010- CB00 110 V AC 3RN1010- CG00 230 V AC 3RN1010- CM00 24 240 V UC 3RN1010- CW00 2 CO 24 V UC 3RN1010- BB00 110 V AC 3RN1010- BG00 230 V AC 3RN1010- BM00 2 CO hard-gold-plated 24 V UC 3RN1010- GB00 Manual/ 1 NO + 1 NC 24 V UC 3RN1011- CB00 remote 3) 110/230 V AC 3RN1011- CK00 Short-circuit detection in the sensor circuit Manual/ 2 CO 24 V UC 3RN1011- BB00 remote 3) 110 V AC 3RN1011- BG00 230 V AC 3RN1011- BM00 2 CO hard-gold-plated 24 V UC 3RN1011- GB00 Holding on supply failure 2) Manual/Auto/ 1 NO + 1 NC 24 V UC 3RN1012- CB00 remote 110/230 V AC 3RN1012- CK00 Holding on supply failure 2), Manual/Auto/ 2 CO 24 V UC 3RN1012- BB00 short circuit in the sensor circuit remote 110 V AC 3RN1012- BG00 230 V AC 3RN1012- BM00 2 CO hard-gold-plated 24 V UC 3RN1012- GB00 Holding on supply failure 2), Manual/Auto/ 2 CO 24 V UC 3RN1013- BB00 short circuit and broken wires in the sensor remote 24 240 V UC 3RN1013-1BW10 circuit are detected and displayed, 3RN1013-2BW00 wide-range voltage with screw terminal 2 CO hard-gold-plated 24 240 V UC 3RN1013-1GW10 with protective separation 1) 3RN1013-2GW00 Evaluation units for 2 sensor circuits, alarm and trip, 22.5 mm wide, monostable, closed-circuit current principle, 3 LEDs Monitoring Relays Test/reset button, holding on supply failure 2) ; Manual/Auto/ 1 NO + 24 240 V UC 3RN1022- DW00 the evaluation circuit for Alarm uses an NO remote contact in the open-circuit principle Evaluation units for 6 sensor circuits, multi-motor protection, 45 mm wide, monostable, closed-circuit current principle, 8 LEDs Test/reset button, holding on supply failure 2) Manual/Auto/ 1 NO + 1 NC 24 240 V UC 3RN1062- CW00 remote Bistable evaluation units, 22.5 mm wide Test/reset button, holding on supply failure 2), Manual/Auto/ 2 CO 24 240 V UC 3RN1013- BW01 short-circuit and broken wires in the sensor remote circuit are detected and displayed, bistable version, not tripped when the control supply voltage fails 1) Protective separation up to 300 V according to DIN/VDE 0106 2) Information regarding the holding on supply failure, refer to Catalog NS K 10/2001, Page 7/11 3) Reset using the Reset button or by interrupting the control supply voltage 1 = screw terminal 2 = spring-loaded terminal 13

3UG3 Monitoring Relays for voltage, line and insulation 3UG3 monitoring relays for phase and voltage monitoring measure various parameters in the main and auxiliary circuits of plants and systems. Wear and faults can be detected early on which means that the appropriate action can be taken before considerably greater damage is caused. Your advantages: None of the three-phase relays need separate auxiliary voltages It is possible to toggle between underrange or overrange Single-phase voltage monitoring with or without auxiliary voltage Single-phase voltage monitoring also using the window technique Applications: The range of applications is shown in the table below. The table indicates which system state can be detected using which monitoring parameters. Structure of a 3-phase line supply monitoring L1 L2 L3 Measured quantity Phase sequence Phase failure Phase imbalance Undervoltage Overvoltage Insulation monitoring Possible plant/system fault Direction of rotation of the drive Fuse blown Control supply voltage failed Single-phase motor operation which results in overheating The motor overheats as a result of asymmetrical phase voltages Asymmetrical loaded line supplies are detected Phase failure is detected in spite of regenerative feedback Increased motor current which results in overheating Device was accidentally reset Line supply collapses, especially for battery-supplied equipment Threshold switch for 0 to 10 V analog signals Protects a plant/system against destruction as a result of supply overvoltages A plant or system is powered-up above a certain voltage Threshold switch for 0 to 10 V analog signals Monitors the insulation resistance for plants/systems with non-grounded line supplies 3UG3 monitoring relay Phase failure Contactor Phase imbalance, voltage 14 M Direction of rotation

3UG3 monitoring relays for the line supply and insulation Phase Phase Phase Symm. Symm. N-conductor Hysteresis Delay Contacts Width Control supply Order No. (MRPD) failure sequence imbalance undervoltage overvoltage monitoring time voltage Yes 1) Yes 2 CO 22.5 mm 3 x 230 460 V AC 3UG3511-1BQ50 Yes Yes 2 CO 22.5 mm 3 x 230 V AC 3UG3513-1BL50 3 x 400 V AC 3UG3513-1BP50 Yes Yes 20% fixed 20% fixed Typ. 5% 0.2 10 s 2 CO 45 mm 3 x 180 260 V AC 3UG3013-1BL60 3 x 230 460 V AC 3UG3013-1BP60 3 x 380 550 V AC 3UG3013-1BR60 3 x 460 660 V AC 3UG3013-1BS60 Yes Yes 5 20% 10% 0.5 10 s 45 mm 3 x 230 V AC 3UG3012-1AL50 3 x 400 V AC 3UG3012-1AP50 Yes No 85 98% and 85 98% 102 115 % 3 % 0.1 10 s + 45 mm 3 x 400 V AC 3UG3041-1BP50 102 115% Yes 3 x 400 V AC 3UG3042-1BP50 Single-phase voltage monitoring Measuring range Overvoltage/ Auto reset/fault Contacts Delay time Hysteresis Auxiliary Electrical Order No. (MRPD) undervoltage memory voltage isolation 0.2 60 V UC Selectable Selectable 0.1 3 s 5 50 % 230 V AC Yes 3UG35311AL20 120 V AC Yes 3UG3531-1AG20 24 V AC Yes 3UG3531-1AC20 24 V DC No 3UG3531-1AC40 15 600 V UC Selectable Selectable 0.1 3 s 5 50 % 230 V AC Yes 3UG3532-1AL20 120 V AC Yes 3UG3532-1AG20 24 V AC Yes 3UG3532-1AC20 24 V DC No 3UG3532-1AC40 15 150 V UC Selectable Selectable 0.1 3 s 5 50 % 3UG3534-1AC50 50 275 V UC 3UG3534-1AM50 15 150 V UC Window (upper Auto reset 0.1 3 s 5 % fixed 3UG3535-1AC50 50 275 V UC and lower 3UG3535-1AM50 threshold values) Monitoring Relays Insulation monitoring for IT line supplies Line supply Measuring range Auto reset/fault memory Contacts Auxiliary voltage Order No. (MRPD) AC 1 110 kω Selectable 115/230 V AC 3UG3081-1AK20 24 240 V AC 3UG3081-1AW30 DC 10 110 kω Selectable 24 240 V AC 3UG3082-1AW30 1) Not tripped for regenerative feedback Return voltage due to coupling between the individual phases Loads connected to the three-phase line supply such as motor windings, lamps, transformers result in a connection between the individual phases. As a result of this coupling between the individual phases, there is always a return voltage at the equipment terminals of the phase that has failed. The 3UG3 monitoring relay detects this reverse voltage as follows: 3UG3511 Return voltage is not detected 3UG3513 Return voltage of between 90 % and 95 % of V rated is detected 3UG3013 Return voltage up to 70 % V rated is detected 3UG3012 Return voltage up to 95 % V rated is detected 15

3UG3 Monitoring Relays for single-phase current and cos ϕ monitoring Monitoring the load of motors and the functionality of electronic loads a clear case for the 3UG3 relays to monitor current and cos ϕ. These devices detect the effect of wear and faults early on. This means that the appropriate actions can be taken before considerably greater damage is caused. Your advantages: Only two versions, each with three measuring ranges per relay (20/100/500 ma and 1/5/10 A) Overrange/underrange and fault memory/no fault memory can be selected Selectable start bypass and delay time for threshold value exceeded/fallen below Current relay only 22.5 mm wide Applications: The range of applications is shown in the table below. The table indicates which system state can be detected using which monitoring parameters. Monitored parameters Current monitoring cos ϕ monitoring System states Overload monitoring Underload monitoring close to the rated torque Functional monitoring of electrical loads Wire breakage monitoring Energy management (phase current monitoring) Threshold switch for 0/4 to 20 ma analog signals No-load monitoring Underload monitoring in the lower power range Very simple cos ϕ monitoring in line supplies to control reactive power compensation equipment Cable interrupted between the cabinet and motor 16

3UG3 monitoring relays single-phase current monitoring Measuring Overrange/ Auto reset/ Contacts Starting Delay time Hysteresis Control supply Electrical Order No. (MRPD) range underrange fault memory bypass time voltage isolation 2 ma 0.5 A UC Selectable Selectable 1 20 s 0.1 3 s 5 50 % 230 V AC Yes 3UG3521-1AL20 in three meas- 120 V AC Yes 3UG3521-1AG20 uring ranges 24 V AC Yes 3UG3521-1AC20 IN1: 2 20 ma 2) 24 V DC 1) Yes 3UG3521-1AC40 IN2: 10 100 ma IN3: 50 500 ma 2 ma 0.5 A UC Selectable Selectable 1 20 s 0.1 3 s 5 50 % 230 V AC Yes 3UG3522-1AL20 in three meas- 120 V AC Yes 3UG3522-1AG20 uring ranges 24 V AC Yes 3UG3522-1AC20 IN1: 0.1 1 A 24 V DC 1) Yes 3UG3522-1AC40 IN2: 0.5 5 A IN3: 1 10 A cos ϕ monitoring Measuring Max. contin- Overcurrent/ Contacts Starting Delay time Hysteresis fixed Voltage Order No. (MRPD) range uous current undercurrent bypass time 0.1 0.99 14 A Window (upper + 0.5 20 s 0.3 3 s 10 % at cos ϕ 0.4 3 x 230 V AC 3UG3014-1BL60 (cos ϕ) and lower 10 30 % at cos ϕ < 0.4 3 x 400 V AC 3UG3014-1BP60 threshold values) 3 x 480 V AC 3UG3014-1BR60 3 x 575 V AC 3UG3014-1BS60 Monitoring Relays 1) For relays with a 24 V DC control supply voltage, the potential of the monitoring circuit must be separate from the potential of the control supply voltage. (CTs can be used for higher currents. A selection is provided in our LV10 Catalog). 2) IN = INPUT Measuring signal frequency: The 3UG352 monitoring relays can measure frequencies from 40 to 500 Hz and DC with the specified accuracy. For other frequencies, the setting must be appropriately changed. Current and cos ϕ as a function of the motor load cos ϕ 1.4 1.2 1.0 0.6 0.4 cos ϕ I Rule of thumb: cos ϕ changes significantly below the rated load; above the rated load, the current increases overproportionally 0.2 0 Rated load 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 Motor load 17

3UG3 Monitoring Relays for level and speed 3UG3 monitoring relays are always used when non-electrical quantities have to be monitored. Almost every liquid is conductive. This characteristic is used to monitor filling levels. If the probes dip into the liquid, then current flows if the probes are not in the liquid, current no longer flows. This allows reliable 2-point controls and alarm messages to be implemented for overflow or dry running operation. Sensors connected to the motor monitor speeds. These supply one pulse per revolution and one signal edge is evaluated. This also means that stationary motors are reliably detected. Your advantages: Level monitoring: 2- and 3-pole wire electrodes, can be very simply mounted from the top Bar-type electrodes for mounting at the side for higher levels and minimum space requirement Sensitivity can be set between 0 and 100 kohm 22.5 mm wide Speed monitoring: Selectable measuring ranges 2- or 3-wire sensors can be connected Sensors with mechanical switches or electronic outputs can be connected Auxiliary voltage for the sensor is integrated in the device Applications: Level monitoring: 1- and 2-point level monitoring Overflow protection Dry-running protection Leakage monitoring Speed monitoring: Slip/breakage of a belt drive Standstill monitoring (no personnel protection) Transport element monitoring for completeness Underspeed condition: + AC PNP A1 + 24 V RES IN1 0V 11 A2 IN2 + 8V2 12 14 18 NSB00976 + NAMUR

3UG3 monitoring relays for 2-point level monitoring of conductive liquids Sensitivity Contacts Width Control supply voltage Order No. (MRPD) 5 100 kohm 22.5 mm 230 V AC 3UG3501-1AL20 120 V AC 3UG3501-1AG20 24 V AC 3UG3501-1AC20 Probes for level monitoring Description Cable connection Number of poles Wire electrodes, 500 mm long, 3 x 0,5 mm 2, 2 m 3-pole 3UG3207-3A with Teflon insulation, 2 x 0,5 mm 2, 2 m 2-pole 3UG3207-2A max. operating temperature 90 C, max. operating pressure 10 bar Bow-type electrode for lateral mounting, 3 x 0,5 mm 2, 2 m 2-pole 3UG3207-2B max. operating temperature 90 C, 2 x 0,5 mm 2, 2 m 1-pole 3UG3207-1B max. operating pressure 10 bar Bar electrode, rugged, 2 x 0,5 mm 2, 2 m 1-pole 3UG3207-1C max. operating temperature 90 C max. operating pressure 10 bar Relays to monitor underspeed Measuring range Starting bypass time Width Voltage Electrical isolation Pulses/min 0.3 30 s 45 mm 230 V AC Yes 3UG3051-1AL20 0.1 600 120 V AC Yes 3UG3051-1AG20 (10 0.0017 Hz) 24 V AC Yes 3UG3051-1AC20 24 V DC No 3UG3051-1AC40 Monitoring Relays 3UG 3207-3A 3UG 3207-2B 3UG 3207-1C 1- and 2-point level monitoring, overflow protection This method can be applied for very many liquids and materials, prerequisite: Specific resistance < 100 kω Product kω Buttermilk 1 Fruit juice 1 Vegetable juice 1 Milk 1 Soup 2.2 Beer 2.2 Coffee 2.2 Ink 2.2 Saltwater 2.2 Wine 2.2 Mineral water 5 Waste water 5 Starch solution 5 Oil 10 Condensation water 18 Soap foam 18 Jams 45 Jellies 45 Sugar solution 90 Whisky 220 Distilled water 450 19

Interface Relays Narrow Design 3TX70 interface relays 3TX70 interface relays are available in two basic versions. The 3TX7004/05/01 series is just 6.2 mm wide: This series means that the interface relays take up a lot less space in the electrical cabinet. Then we have our 3TX7002/03 series: They are suitable for mounting in small electrical cabinets with low depth and with short distances between the mounting rails. Both series are available with an extensive range of input and output interfaces. Your advantages: 3TX7002/03 and 3TX7004/05 Operating range from 0.7 to 1.25 V S at 24 V DC up to 60 C Protective circuit is integrated in the input High degree of reliability using a relay which is soldered-in Connection comb and cable to connect voltages at the same potential Manual-0-automatic switch for easier commissioning Your advantages: 3TX7014 Plug-in relay that can be quickly replaced with pre-assembled wiring Conductors are introduced and clamped from the front therefore lower wiring times Tested, complete devices reduce installation times Individual relays are available as spare part Relay version with hard gold-plated contacts therefore high contact reliability Applications: Electrical isolation Voltage conversion e. g. from 24 V DC to 230 V AC Signal amplification Contact multiplication General relay controls Overvoltage and EMC protection of controls Engineering information: When selecting the interface for rated control supply voltages of 110 V AC and 230 V AC relays, the maximum missible cable length must be carefully observed. The special 3TX700-05 relay can be used for longer cables. Interface relays as input or output coupler Peripheral devices Electronic control 110 V AC 230 V AC 24 V DC Input Output 24 V DC 110 V AC 230 V AC Actuators M Pushbutton, position switch Input interface Output interface Motor contactors 20

Interface relays 3TX700 3TX7004/05 output interface with relay output Contacts Control supply voltage Width Hard-gold-plating M-0-A switch Order No. (MRPD) 24 V UC 6.2 mm 3TX700-1LB00 Yes 3TX700-1LB02 12.5 mm Yes 3TX700-1BB10 230 V UC 6.2 mm 3TX700-1LF00 12.5 mm 3TX700-1BF05 1) 10 40 V UC 6,2 mm 3TX700-1LH00 1 NO 24 V UC 6.2 mm 3TX700-1MB00 230 V UC 6.2 mm 3TX700-1MF00 3TX7004/05 Input interface with relay output 1 NO 230 V UC 6.2 mm Yes 3TX700-2MF02 110 V UC 6.2 mm Yes 3TX700-2ME02 24 V UC 6.2 mm Yes 3TX700-2MB02 1) For long cable lengths of up to 350 m Plug-in interface, complete with relay 4 = screw terminal 5 = spring-loaded terminal 3TX7002/03 for low tier heights output interface with relay output Output Control supply voltage Width Hard-gold-plating 1 NO 24 V UC 11.5 mm 3TX700-1AB00 11.5 mm Yes 3TX700-1AB02 24 V UC 17.5 mm 3TX700-1BB00 230 V UC 17.5 mm 3TX700-1BF00 2 NO 24 V UC 22.5 mm 3TX700-1CB00 2 CO 24 V UC 22.5 mm Yes 3TX700-1FB02 3TX7002/03 Input interface with relay output 1 NO 230 V UC 11.5 mm 3TX700-2AF00 230 V UC 11.5 mm 3TX700-2AF05 1) 110 V UC 11.5 mm 3TX700-2AE00 24 V UC 11.5 mm 3TX700-2AB00 230 V UC 17.5 mm Yes 3TX700-2BF02 Accessories Connecting cable with 24 connecting points for 3TX70* 3TX7004-8BA00 Connecting comb with 24 connecting points for 3TX7004, 6.2 mm wide 3TX7004-8AA00 2 = screw terminal 3 = spring-loaded terminal Contact Rated control Width Hard-gold-plating M-0-A switch Order No. (MRPD) supply voltage Vs 1NO 24 V DC 6.2 mm 3TX7014-1AM00 1CO 24 V DC 6.2 mm 3TX7014-1BM00 24 V UC 6.2 mm 3TX7014-1BB00 115 V UC 6.2 mm 3TX7014-1BE00 230 V UC 6.2 mm 3TX7014-1BF00 Plug-in interface, complete with relay and hard-gold plating 1CO 24 V DC 6.2 mm Yes 3TX7014-1BM02 24 V UC 6.2 mm Yes 3TX7014-1BB02 115 V UC 6.2 mm Yes 3TX7014-1BE02 230 V UC 6.2 mm Yes 3TX7014-1BF02 Accessories Interface Relays and Converters Connecting comb 16-pin 3TX7014-7AA00 21

Interface Relays Narrow Design 3TX70 semiconductor interfaces Interface modules are available with either conventional relays or semiconductors. Compared to interface relays, semiconductor-type interfaces offer some significant advantages: The electronic components are extremely reliable and long-lasting (refer to the diagram below). The input interface combines the best of both worlds improved technical features and a lower price. When considering output interfaces, the question of relay or semiconductor needs to be taken into account as well as the making/breaking capacity and the number of switching cycles. If a relay has to be replaced just once during the complete lifetime of a machine, then a semiconductor interface will already have paid for itself. Your advantages: Favorably priced and reliable: Input interfaces with semiconductor output Graduated series of output interfaces with semiconductors Extremely long electrical life Extremely good contact reliability High DC making/breaking capacity Applications: Providing electrical isolation, converting voltages Switching DC loads Switching capacitive loads High number of switching cycles Overvoltage and EMC protection of controls Comparison of lifetimes Probability of failure high average low Start of wear for mechanical components Probability of failure for electronic components Lifetime Electronic interface modules have a significantly higher lifetime than electromechanical devices Voltages at the same potential can be simply jumpered using the accessories Using semiconductor interfaces Electronic control Actuators Input Output 24 V DC M Semiconductor interface Solenoid valve 22

3TX70 semiconductor interfaces 3TX7004/05 the narrow space saver output interface with relay output Control supply Width Max. switching Switching Min. load Short-time M-0-A- Order No. (MRPD) voltage current voltage current load capacity switch 24 V DC 6.2 mm 0.5 A 48 V DC 1.5 A/20 ms 3TX700-3AB04 0.75 A 200 V DC 3 A/2 ms 3TX700-3PB41 1.5 A 30 V DC Short-circuit-proof 3TX700-3PB54 12.5 mm 5 A 30 V DC 0.5 A Short-circuit-proof 3TX700-3AC04 12.5 mm 5 A 30 V DC 0.5 A Short-circuit-proof Yes 3TX700-3AC14 6.2 mm 0.5 A 24 250 V AC 0.01 A 0.8 A/3 ms 3TX700-3RB43 12.5 mm 2 A 24 250 V AC 0.05 A 100 A/20 ms 3TX700-3AC03 110 230 V AC 6.2 mm 3 A 30 V DC Short-circuit-proof 3TX700-3PG74 Input interface with semiconductor output, 1 NO contact 110 230 V AC 6.2 mm 0.1 A 30 V DC 0.2 A/3 ms 3TX700-4PG24 24 V DC 0.1 A 30 V DC 0.2 A/3 ms 3TX700-4PB24 24 V DC 0.5 A 48 V DC 1.5 A/20 ms 3TX700-4AB04 4 = screw terminal 5 = spring-loaded terminal 3TX7002 for low tier heights output interface with semiconductor output, 1 NO contact Control supply Width Max. switching Switching Min. load Short-time load capacity Order No. (MRPD) voltage current voltage current 24 V DC 12.5 mm 1.8 A 48 264 V AC 0.06 A 20 A/20 ms 3TX7002-3AB00 24 V DC 11.5 mm 1.5 A 60 V DC 4 A/0.2 ms 3TX7002-3AB01 Input interface with semiconductor output, 1 NO contact 110 230 V AC 12.5 mm 0.1 A 60 V DC 1 A/20 ms 3TX7002-4AG00 24 V UC 12.5 mm 0.1 A 30 V DC 1 A/20 ms 3TX7002-4AB00 Accessories Connecting cable with 24 connecting points for 3TX70* 3TX7004-8BA00 Connecting comb with 24 connecting points for 3TX7004, 6.2 mm wide 3TX7004-8AA00 Interface Relays and Converters 23

Interface Relays in a Rugged Enclosure 3RS18 relay interfaces The new 3RS18 interface relays set new standards: They have a wide-range voltage extending from 24 V UC up to 240 V which makes them absolutely unique in the interface market. All of these devices are accommodated in a well-proven, rugged 22.5 mm wide enclosure. Relays with 1, 2 and 3 changeover contacts both available with screw and spring-loaded terminals and in combination and wide-range voltage with hard-gold-plated contacts for especially high contact reliability and that even at low currents. Thanks to the well-proven rugged enclosure, you can enjoy the benefits of user-friendly connection systems, including spring-loaded terminals just the same as for our time relays. 2 conductors can be connected at each terminal point. Your advantages: NEW New worldwide: One device for all voltages Lower costs due to fewer versions User-friendly wiring Especially high contact reliability even at low currents Space-saving design Applications: Everywhere where contacts which are electronics-compatible are required and where devices with wide-range voltage are used Thanks to the hard-gold-plated contacts predestined for PLC I/O 3RS18 interface relays Interface relays in a rugged 22.5 mm enclosure Rated control supply voltage Vs Contact Screw terminal spring-loaded versions terminal 50/60 Hz W Order No. Order No. Wide-range voltage 24 240 V UC 2 3RS18 00-1BW00 3RS18 00-2BW00 3 3RS18 00-1HW00 3RS18 00-2HW00 3 1) 3RS18 00-1HW01 3RS18 00-2HW01 Combination voltage 24 V UC and 1 3RS18 00-1AQ00 3RS18 00-2AQ00 110 120 V AC 2 3RS18 00-1BQ00 3RS18 00-2BQ00 3 3RS18 00-1HQ00 3RS18 00-2HQ00 3 1) 3RS18 00-1HQ01 3RS18 00-2HQ01 24 V UC and 1 3RS18 00-1AP00 3RS18 00-2AP00 220 240 V AC 2 3RS18 00-1BP00 3RS18 00-2BP00 3 3RS18 00-1HP00 3RS18 00-2HP00 3 1) 3RS18 00-1HP01 3RS18 00-2HP01 1) Hard-gold-plated 24

LZX Plug-In Relays LZX plug-in relays are available either as complete device or as individual modules. These individual modules can then be assembled or are used as spare part. This family is subdivided into four designs: LZX:RT, LZX:RY, LZX:PT and LZX:MT. Your advantages: Tested AC-15 and DC-13 switching capacity LZX:RT/LZX:RY/LZX:PT either as individual module or complete device Extensive range of accessories Coil voltages: 24 V DC, 24 V AC, 115 V AC, 230 V AC Applications: As interface relay to couple inputs and outputs for electronic controls Multiplying contacts Switching small loads As measured value changeover switch Making/breaking capacity AC-15, 230 V DC-13, 24 V LZX:RT (changeover contact) 6 A 2 A LZX:RT 2 CO 3 A 2 A LZX:PT 2 CO 5 A 5 A LZX:PT 3 CO 5 A 5 A LZX:PT 4 CO 4 A 5 A LZX:MT 3 CO 5 A 2 A Engineering information: For LZX:PT relays, the test lever does not latch. If the test lever is pressed further until 90 is reached, two small lugs break off and the test lever can then be adjusted so that it latches. When LZX is used with 60 Hz AC voltages, the lower response value must be increased by 10 % and the power loss slightly increases. Designs Interface Relays and Converters LZX:RT 1 or 2 changeover contacts AC-1: 16/8 A 15.5 mm wide LZX:RY 1 changeover contact AC-1: 8 A 15.5 mm wide LZX:PT 2, 3 or 4 changeover contacts AC-1: 12/10/6 A 27 mm wide LZX:MT 3 changeover contacts AC-1: 10 A 38 mm wide 25

Relay interfaces complete modules (socket, relay, hold/eject clip, LED module and inscription plate) Version Rated control Contacts Width Order No. supply voltage Vs Complete device, 11- and 14-pin, PT series Complete device with plug-in socket 24 V DC 3 CO 27 LZX:PT3A5L24 Standard 24 V AC LZX:PT3A5R24 for snapping onto 35 mm mounting rails, 115 V AC LZX:PT3A5S15 comprising: 230 V AC LZX:PT3A5T30 Plug-in relay, standard plug-in socket, LED module 24 V DC 4 CO 27 LZX:PT5A5L24 (24 V DC LED module with free-wheeling diode, 24 V AC LZX:PT5A5R24 AC without free-wheeling diode), hold/eject clip 115 V AC LZX:PT5A5S15 and label 230 V AC LZX:PT5A5T30 Complete device with plug-in socket 24 V DC 3 CO 27 LZX:PT3B5L24 (logical separation) 24 V AC LZX:PT3B5R24 for snapping onto 35 mm mounting rails, 115 V AC LZX:PT3B5S15 comprising: 230 V AC LZX:PT3B5T30 Plug-in relay, with protective separation, LED module 24 V DC 4 CO 27 LZX:PT5B5L24 (24 V DC LED module with free-wheeling diode, 24 V AC LZX:PT5B5R24 AC without free-wheeling diode), hold/eject clip 115 V AC LZX:PT5B5S15 and label 230 V AC LZX:PT5B5T30 Complete device, 8-pin, 5 mm pinning, RT series Complete device with plug-in socket 24 V DC 15.5 LZX:RT3A4L24 Standard 24 V DC 2 CO LZX:RT4A4L24 for snapping onto 35 mm mounting rails, 230 V AC LZX:RT3A4T30 comprising: 230 V AC 2 CO LZX:RT4A4T30 PC-board-mounted relay, standard plug-in socket, 24 V AC 15.5 LZX:RT3A4R24 LED module (24 V DC LED module with free-wheeling 24 V AC 2 CO LZX:RT4A4R24 diode, AC without free-wheeling diode), 115 V AC LZX:RT3A4S15 hold/eject clip and label 115 V AC 2 CO LZX:RT4A4S15 Complete device with plug-in socket 24 V DC 15.5 LZX:RT3B4L24 (logical separation) 24 V DC 2 CO LZX:RT4B4L24 for snapping onto 35 mm mounting rails, 230 V AC LZX:RT3B4T30 comprising: 230 V AC 2 CO LZX:RT4B4T30 PC board relay with protective separation, 24 V AC 15.5 LZX:RT3B4R24 LED module (24 V DC LED module with free-wheeling 24 V AC 2 CO LZX:RT4B4R24 diode, AC without free-wheeling diode), 115 V AC LZX:RT3B4S15 hold/eject clip and label 115 V AC 2 CO LZX:RT4B4S15 Complete device, 5-pin, 3.2 mm pinning, RY series Complete device with plug-in socket 24 V DC 15.5 LZX:RY1A4L24 (logical separation) for snapping onto 35 mm mounting rails, comprising: PC board relay with protective separation, LED module (24 V DC LED module with free-wheeling diode, AC without free-wheeling diode), hold/eject clip and inscription plate Note: Logical separation: The contact connections and the coil connections are located separately at different levels, e. g. the contacts at the top and for the coil at the bottom. The logical separation does not represent protective separation. Protective separation: The protective separation is a separation which prevents, with sufficient safety, a voltage overspilling from one circuit to another (DIN VDE 106 Part 101). 26

Interface relays individual modules for self-assembly Control supply voltage Contacts LED Free-wheeling diode Logical separation Hard-gold-plated Order No. (MRPD) Individual modules for self-assembly: Relays 24 V DC No No No LZX:RT314024 24 V DC 2 CO No No No LZX:RT424024 24 V AC No No No LZX:RT314524 24 V AC 2 CO No No No LZX:RT424524 115 V AC No No No LZX:RT314615 115 V AC 2 CO No No No LZX:RT424615 230 V AC No No No LZX:RT314730 230 V AC No No No LZX:RT424730 24 V DC No No Yes LZX:RT315024 230 V AC No No Yes LZX:RT315730 Accessories for LZX:RT, matching 1 and 2 changeover contacts Plug-in socket for snapping onto mounting rails No logical separation LZX:RT78625 With logical separation LZX:RT78626 Hold/eject clip LZX:RT16016 Label LZX:RY16040 LZX plug-in relay: PT the small and high-performance individual parts for self-assembly: Relays, 12.7 mm wide Control supply voltage Contacts LED Free-wheeling diode Hard-gold-plated Test lever Order No. (MRPD) 24 V DC 2 CO No No No Yes LZX:PT270024 24 V DC 3 CO No No No Yes LZX:PT370024 24 V DC 4 CO No No No Yes LZX:PT570024 24 V DC 4 CO No No No No LZX:PT520024 24 V AC 2 CO No No No Yes LZX:PT270524 24 V AC 3 CO No No No Yes LZX:PT370524 24 V AC 4 CO No No No Yes LZX:PT570524 115 V AC 2 CO No No No Yes LZX:PT270615 115 V AC 3 CO No No No Yes LZX:PT370615 115 V AC 4 CO No No No Yes LZX:PT570615 230 V AC 2 CO No No No Yes LZX:PT270730 230 V AC 3 CO No No No Yes LZX:PT370730 230 V AC 4 CO No No No Yes LZX:PT570730 230 V AC 4 CO No No Yes Yes LZX:PT580730 230 V AC 4 CO No No No No LZX:PT520730 Accessories for LZX:PT Plug-in socket for snapping onto mounting rails 2 CO LZX:PT78702 3 CO LZX:PT78703 4 CO LZX:PT78704 Hold/eject clip 2/3/4 CO LZX:PT16016 Label LZX:PT16040 Accessories for LZX:RT and LZX:PT LED module, red Control supply voltage 24 V DC Free-wheeling diode LZX:RPML0024 24 V UC LZX:RPML0524 110 230 V AC LZX:RPML0730 LED module, green 24 V DC Free-wheeling diode LZX:RPMG0024 110 230 V AC LZX:RPMG0730 Free-wheeling diode 24 V DC Free-wheeling diode LZX:RPMT00A0 RC element 24 48 V AC LZX:RPMU0548 110 230 V AC LZX:RPMU0730 LZX:MT for high voltages and currents individual components for self-assembly: Relays Control supply voltage Contacts LED Free-wheeling diode Order No. (MRPD) 24 V DC 3 CO LZX:MT321024 24 V DC 3 CO Yes LZX:MT323024 24 V AC 3 CO LZX:MT326024 24 V AC 3 CO Yes LZX:MT328024 115 V AC 3 CO LZX:MT326115 115 V AC 3 CO Yes LZX:MT328115 230 V AC 3 CO LZX:MT326230 230 V AC 3 CO Yes LZX:MT328230 Accessories for LZX:MT Plug-in socket for snapping onto mounting rails, 11-pin LZX:MT78750 Holding Clip LZX:MT28800 Interface Relays and Converters 27

3RS17 Interface Converters Normalized signal and universal converters Interface converters are mainly used to isolate and convert analog signals. Sensors/actuators and controls generally have different power supply units and therefore require electrical isolation in the signal circuit. This is either integrated in the control or is implemented using an interface converter. A signal must be converted into another signal if, for instance, a voltage signal needs to be transmitted over a long distance as a current signal or if the output of a sensor and the input of a control system are not compatible with one another. Frequency outputs can be used for an additional application. In this case, the input signal is converted into a proportional frequency. This means that analog signals can be processed with digital inputs. This is important if the control does not allow an analog input to be installed or if all of its analog inputs are already assigned. This can occur, for example, when devices are retrofitted. Your advantages: Narrow Easy-to-set universal converter Converters with frequency output All ranges are fully calibrated Unified family of devices the ideal solution for every application Integrated manual-automatic switch with adjustable setpoint Outputs are short-circuit-proof Up to 30 V protected against damage caused by faulty wiring Applications: Electrical isolation of analog signals Converting analog signals Converting analog signals into a frequency Converting from non-normalized into normalized signals Overvoltage protection for analog inputs Engineering information: Passive converters draw the power they require from the analog signal. They do not require their own power supply. For 2-way isolation, the input is electrically isolated from the output and from the power supply, output and power supply are at the same potential. For 3-way isolation, all of the three circuits are isolated from one another. 28

3RS17 interface converters Input Output Width H-A- Control supply Electrical Order No. (MRPD) switch voltage isolation 0...10 V 0...10 V 6.2 mm No 24 V UC 2-way 3RS1700- AD00 0...10 V 0...20 ma 6.2 mm No 24 V UC 2-way 3RS1700- CD00 0...10 V 4...20 ma 6.2 mm No 24 V UC 2-way 3RS1700- DD00 0...20 ma 0...10 V 6.2 mm No 24 V UC 2-way 3RS1702- AD00 0...20 ma 0...20 ma 6.2 mm No 24 V UC 2-way 3RS1702- CD00 0...20 ma 4...20 ma 6.2 mm No 24 V UC 2-way 3RS1702- DD00 4...20 ma 0...10 V 6.2 mm No 24 V UC 2-way 3RS1703- AD00 4...20 ma 0...20 ma 6.2 mm No 24 V UC 2-way 3RS1703- CD00 4...20 ma 4...20 ma 6.2 mm No 24 V UC 2-way 3RS1703- DD00 0...20 ma 0...20 ma 6.2 mm No Passive converter 2-way 3RS1720- ET00 0...20 ma 0...20 ma 12.5 mm No Passive converter 2-way 3RS1721- ET00 2 x 0...20 ma 2 x 0...20 ma 12.5 mm No Passive converter 2-way 3RS1722- ET00 Standard interface converter which can be changed-over 0...10 V 0...10 V 6.2 mm No 24 V UC 2-way 3RS1705- FD00 0/4...20 ma 0/4...20 ma selectable selectable 17.5 mm No 24 240 V UC 3-way 3RS1705- FW00 0...10 V 0...10 V 17.5 mm Yes 24 V UC 2-way 3RS1725- FD00 0/4...20 ma 0/4...20 ma selectable selectable 17.5 mm Yes 24 240 V UC 3-way 3RS1725- FW00 0...10 V 0...50 Hz 6.2 mm No 24 V UC 2-way 3RS1705- KD00 0/4...20 ma 0...100 Hz selectable 0...1 khz 0...10 khz 17.,5 mm No 24 240 V UC 3- way 3RS1705- KW00 selectable Universal converters 0...60 mv 0...100 mv 0...300 mv 0...500 mv 0...1 V 0...2 V 0...5 V 0...10 V 0...10 V 17.5 mm No 24 V UC 2-way 3RS1706- FD00 0...20 V 0/4...20 ma 24 V UC 3-way 3RS1706- FE00 2...10 V selectable 24 240 V UC 3-way 3RS1706- FW00 0...5 ma 0...10 ma 0...20 ma 4...20 ma ± 5 ma ± 20 ma Interface Relays and Converters 1 = screw terminal 2 = spring-loaded terminal 29

3TG10 Power Relays and SITOP Power Supplies 3TG10 power relays come through with flying colors wherever low-noise relays or contactors are required and that at a low price. The power relays are suitable for basic controls, and especially for use in large series equipment and control systems. They are ideal for applications which only need an auxiliary contact and not an overload relay yet at the same time demand a higher making/breaking capacity, additional switching voltage and a longer lifetime. Your advantages: Can be mounted in any position, hum-free Protective separation Can be screwed or inserted Integrated auxiliary contact AC-3 power: 4 kw/400 V Operating current I e /AC-1: 20 A/400 V Inrush current per phase: 90 A Integrated overvoltage damping Slimline design, only 36 mm wide Applications: Domestic appliances and installation Hoisting systems: Small elevators, elevating platforms Building services, hum-free devices in building systems, e. g. in hospitals Engineering information: When the three main current paths conduct 20 A, for I > 10 A for the fourth current path: Permissible ambient temperature 40 C. 6EP1 SITOP wide-voltage range power supply units The 6EP1 primary switched-mode SITOP wide-voltage range power supply units in a narrow 22.5 mm housing were especially developed as ballast for standard products if unusual supply voltages and/or wide operating ranges have to be catered for. These devices have wide input voltage ranges and a 22 V DC output. This means that you can use standard units for almost all power supply voltages which are used. This cuts out the costs for special designs and reduces engineering times. Your advantages: Only 22.5 mm wide Wide input voltage range Low weight High degree of efficiency Applications: Voltage ballast for all voltage ranges Voltage ballast for wide operating ranges 30