Using UniOP HMI panels with Galil controllers

Similar documents
Connecting UniOP to Galil/Yaskawa controllers

IAI Corporation 1998, 1999, For Reference Only.

VS-626M5 Parameter Upload/Download Software User s Manual (Preliminary) 5/18/99

Getting Started with UniOP B Series Panels

ABB AC500 Technical Help Sheet

Connecting UniOP to the ABB 07KT97 Controllers

Note: the wiring of the dead-man buttons has been changed since October 2001.

SAPHIR SIO Driver. Siemens Building Technologies

Newsletter. Communicate and Stay in Control. In This Issue

TECH-NOTE. The Keyboard Macro Editor. The Keyboard Macro Editor Dialog Box

MW100 CAN Bus Module Configuration Tool (MX118-CAN-M30/S1) User s Manual

Connecting UniOP to Fatek Controllers with Facon Protocol

AMS COCKPIT USERS GUIDE. AMS Cockpit Version 1.1 USERS GUIDE

UniOP epad30, epad32. Tech-note PN# tn171-3.doc - 03/10/ Ver Highlights

Connecting UniOP to Simatic S7 MPI

UniOP with Siemens S5 PLC's using 3964R

UniOP Command Summary

Connecting UniOP to Profibus DP TI

PWS6300S Operating Guide HITECH. Introduction

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

MMI6070 Quick Start Guide

for Watlow Controllers Quick Start Guide Version 5.0

Connecting UniOP to Moeller Easy800

New Features in Designer 5.05/UniOP 4.20

The UniDataExchanger is a tool that allows an easier handling of the file transfer to and from UniOP operator panels. Contents

SwiftView Quick-Start Guide. Revised for SwiftView

GEM80 & ewon Setup Quick Guide

Section 1 Introduction

Connecting UniOP to Simatic S7 Profibus

SPECIFICATION APPROVAL SHEET

Pass-Through Function

FEC-240G. Rev. Date

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Pop. Parker operator panels. Rometec srl - - Rometec srl - - Rometec srl -

Motion Control Products Application note Connecting CP600 to motion products via Modbus RTU

GTWIN 1.1 CONTROL TECHNOLOGY CORPORATION. GTWIN 2.8 Quick Start. MGT Panel & GTWIN Quick Start Guide

TPEditor User Manual

LCD Module RSI12864**K*-02 RAYLID. Application Notes -Support UART. RSI12864**K*-02 Application Notes. Ver:

PWS3260 Installation Guide

TPC1. User s Manual. DYNASERVO INC.

Application Note #5525

SIMATIC S5 CPU Direct Driver

USB485. USB to RS485 Converter Card. User Manual for connecting with Windows Vista Version 1.01

Title: Using the AUX Port.

I-Dent Marker Communications for 186 CPU Firmware Versions 1 and 2

Motion Control Products Application note Connecting CP600 to motion products via Modbus RTU

UniOP epad03 and epad04

Grayhill 3Dxx Display Products. Setup and Usage with CoDeSys Development Software

Guide to Eason 2000 Family With Galil Motion Controllers: PC104-13A or PC10413B-I Internal or Stand-Alone External

Updating Reader Firmware

Figure 1: NC > 2 Axis menu > Options

Connecting UniOP as a Modbus Slave

BQ & BQ370-01N MODBUS ANALOG INPUT DEVICE USER MANUAL

epalm10 Product Manual

TA0139 USER MANUAL ARDUINO 2 WHEEL DRIVE WIRELESS BLUETOOTH ROBOT KIT

8S RS232/422/485 Combo to USB2.0 Module Box Installation Guide

CTC Load Utility TM User Guide

NT31/631 Multi-Vendor Connection

Extruder Controls ExtruVision S

Title: Using the AUX Port.

Forms Desktop for Windows Version 4 Manual

UniOP. Touch & Controls

SmartPad LCD Touch Screen Controller Advanced Feature Addendum

Lumio Release Note Lumio Multi-Touch Communication Protocol

PenMount 9084 Setup and Users Manu

Datapanel. VT100 Terminal Emulator for Datapanels. Operator Interface Products. User's Manual

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

WELDSEQ Plus. Operation / Installation Manual. Weld Sequence PLC Terminal Program. Computer Weld Technology, Inc.

USER MANUAL FOR FIOA-0402-U-16

GP-37W2->GP4000 Series Replacement Guidebook

Please refer to application note AN00129 for further details on HCP2 configuration in ABB motion control products.

Getting started with UniOP and CoDeSys integrated controller

GUI MANAGER USER GUIDE

TouchWin User Manual

User Manual pdoc Signer

FULL 36 MONTHS GUARANTEE.

SIMATIC S5 CPU Direct Driver

IO Expansion Shield User Manual

Dip Switch settings for 2-wire and 4-wire configuration. Schneider Electric - Division - Name Date

Getting started with your DGH module:

Easy! Smooth! ST-3300 Series->GP4000 Series Replacement Guidebook

ASIC-200 Version 5.0. integrated industrial control software. HMI Guide

TTL TO ETHERNET Module. MODEL No: TTL-Sereth1P VER 1.0

Centurion PLUS CPC4 Download Guide using C4 File Transfer Utility

MBB100 / DSM800 Update Instructions

using the Data-Linc SRM6000 Spread Spectrum Radio Modem (version 5.39) and Wonderware InTouch 95 (version 7.0.1)

ProjectorNetTM Adapter Quick Start Guide

1 / 20. User Manual. Getting started with devention DfuSe USB upgrade tool

PWS1711/1760 Installation Guide

Easy! Smooth! GP/ST-3500 Series->GP4000 Series Replacement Guidebook

Motion Control Products Application note How to display a page to indicate communication error

This document explains several types of Windows Vista assistance available for people with visual, dexterity, or hearing impairments.

STEPware-100 Operations Manual

DF1 Driver. Rockwell Automation, Inc.

Bristol Babcock BSAP Serial & UDP Communications Drivers

JMobile Suite User Manual

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

PMEUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

1.STARTUP FUNDAMENTALS...21

Firmware zippack name : R exe Firmware File Name : Dell1815dn_V _AutoUpgrade.exe

Transcription:

Application Note #5431 Using UniOP HMI panels with Galil controllers EXOR Electronics R&D offers the UniOP etop series HMI touch screen panels, which can effectively interface serially with Galil DMC 2x00 and 1500 series controllers. The UniOp panels can send commands, modify variables and arrays, and display controller data (such as position, error, switch status, etc.) in a graphical operator interface. The UniOP series panels feature a 5.6 diagonal display with VGA (320x240 pixels) resolution. These panels are offered in three different LCD display formats: etop10 etop11 etop12 TFT w/256 colors STN w/16 colors Monochrome The UniOP panels also feature 8 MB of flash memory for application programs that are easily designed and programmed using the UniOP Designer (version 5.08) software. This application note describes the setup and operation of the UniOP etop11 HMI panel with a Galil DMC-2x00 series controller. Example programs and screenshots are also provided to demonstrate the ease in which the panel can be programmed. Communications Hardware Setup Communications from the UniOp panel to the Galil DMC-2x00 or 1500 series controller is made with a simple RS-232 connection from the PLC port on the panel to the main serial port on the controller. The controller Baud rate should be set at 38.4K with no hardware handshaking (i.e. only switch 6 is on for DMC-2x00 and only switches 3 and 4 are on for DMC-1500). The cable (which can be purchased from Exor, part #CA81) is a 15-pin D type to a 9-pin D type with the following specifications. UniOp panel Galil DMC-2x00 controller 15-pin D type 9-pin D type 1 - Shield 2 - RXD 2 - TXD 3 - TXD 3 - RXD 5 - GND 5 - GND - 1 -

Once the hardware connections are made and the controller s DIP switches are properly set, the UniOP panel must then be configured for the proper Baud rate which is described in the following section. UniOP Panel Communications and Driver Setup To communicate with the Galil controller, the UniOP panel must be setup with the proper driver and Baud rate. The driver for the Galil DMC controller is contained in the driver file UPLC82.dll, which should be located in the C:\Program Files\Designer directory. If the driver is not in this directory, download the driver (in Zip format) from the Exor website http://www.exor-rd.com/support/communicationdrivers/ and unzip it to the directory. The driver setup and configurations are made using the UniOP Designer software (Version 5.08). After installing the Designer software, select Change Controller Driver from the Project menu. The following dialog box contains the button Find All which will install the driver and allow the user to select it from a list. Select the driver Galil/Yaskawa FW Drv Ver. 3.07 DLL Ver. 5.02. Next, select Controller Setup from the Project menu. Click Drive Comm and select Baud rate 38.4, parity none, 8 data bits, and 1 stop bit. At this point, the panel driver and communications settings are only loaded to the software. The drivers and settings will be transferred to the UniOP panel as part of an application program that is downloaded to the panel. Note: each time an application program is downloaded to the panel, make sure that the proper communications settings and drivers are selected. Application Programming Application programs are easily created using the Designer software. Commands can be sent to the controller using a command macro, which is associated with a command button that is simply drawn on the designer layout screen. Figure-1 shows the typical layout of the Designer software. The layout screen allows the programmer to arrange buttons, text, and controls just as they will appear on the UniOP display screen. Valid command strings that can be sent using the macro are the same Galil commands that can be sent using a standard Galil terminal (see the Galil Command Reference for more information on specific command usage). The following example demonstrates the steps in creating a command button to send a Jog command string to the controller and dynamically display the current position as the motion occurs. - 2 -

Figure 1 - Typical Designer Form Layout First, draw a button on the layout screen using the generic command button icon from the floating tool bar. A dialog box appears which allows selection of the button appearance and properties. In this dialog box, select command macro under functionality and then click configure function.. The next dialog box prompts you to define the macro. Select the large C (send command), which then pops up the Galil Define field box, and then select OK. The next box that displays is where you type in the Galil command string (uppercase letters). After entering in the command string, click OK until the main command button properties screen is displayed. Now, you can size the button, change fonts, colors and place an appropriate label on the button. The following screens in Figure-2 show the order in which the dialog boxes appear. - 3 -

Figure 2 - Command Macro Screen Sequence - 4 -

The next step is to define a data field on the form to display the current axis position. Select a location for the desired data field to be displayed on the form. Select the 999 button with the green arrow from the main tool bar. This will show the dialog box in Figure-3. Here, select the data type as Actual Pos. X. and define the data field to a width of 12 characters (to support the maximum size of the incoming data). Figure 3 - Define Field Dialog Box The data fields can also be used to define variables or an array that become global between the controller and the UniOP panel. These global variables must be defined as Vnnn where nnn is a three-digit number. For example, the variable should be defined as V001 (not V1). One array may be defined as UNIOP[zzzz], where zzzz is a four digit number from 0 to 4999. Use the DM command to dimension this array up to 5000 elements. Also note the variables defined in the UniOP panel are limited to integer values, hence the UniOP will only read the integer part of the variables and disregard the fractional part. Figure-4 shows the completed sample application program (with an additional stop button, text, and a bitmap graphic), which can now be downloaded to the UniOP panel. - 5 -

To download the application, set the UniOP panel in the configuration mode and select Download from the Transfer menu. The application program will download to the panel and automatically start. At this point, with the controller connected and powered up, you should be able to operate the controller with the UniOP panel. For more information on connecting the panel to a PC and downloading programs, as well as advanced programming features of the UniOP panel, please refer to the UniOP Designer documentation. Figure 4 - Application Program Ready for Download - 6 -