Three-phase monitoring relay

Similar documents
Electronic timer CT-ARS.11

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.21

Electronic timer CT-ERD.12

Electronic timer CT-AHD.22

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Messaging module CP-C MM

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Contact protection relay

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relay CM-MSS.41

Thermistor motor protection relay CM-MSS.21

Redundancy unit CP-A RU

Thermistor motor protection relay CM-MSS.11

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Power supply CP-C 24/5.0

Thermistor motor protection relay CM-MSS.41

Thermistor motor protection relay CM-MSS.31

Power supply CP-C 24/5.0

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-D 12/2.1 Primary switch mode power supply

Pluggable interface relays CR-P Pcb relays

Power supply CP-E 24/0.75 Primary switch mode power supply

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Power supply CP-E 24/10.0 Primary switch mode power supply

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Accessories for pluggable interface relays CR-P Sockets

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Accessories for pluggable interface relays CR-M Sockets

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Pluggable interface relays CR-M Miniature relays

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Pluggable interface relays and optocouplers CR-P Pcb relays, optocouplers and accessories

Electronic timers CT range

Pluggable interface relays CR-M Miniature relays

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

02/11/2015

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

Electronic timers CT range

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM4JA01F current measurement relay RM4-J - range ma V AC

Zelio Control-modular measurement and control relays 1

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RM4JA32MW current measurement relay RM4-J - range A V AC DC

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

DC561, digital input/output module,

RM35LM33MW liquid level control relay RM35-L V AC/DC

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

DI572 Digital Input Module

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RM35TF V AC

em4 Accessories Digital expansions

DC562, digital input/output module,

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

MINI MCR-SL-UI-REL(-SP)

ABB i-bus KNX HCC/S Heating/cooling circuit controller

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

AI561 Analog Input Module

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

DX561 Digital Input/Output Module

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

Zelio Control Measurement Relays Multifunction 3-phase supply control relays RM17T 00

AO561 Analog Output Module

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Transcription:

2CDC 251 044 F0t08 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay status 2 Marker label A C D K E L UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC RMRS Marks a b CE C-Tick Order data Type Rated control supply voltage = measuring voltage Order code 3x200-500 AC 1SR 430 824 R9300 Order data - Accessories Type Description Order code ADP.01 Adapter for screw mounting 1SR 430 029 R0100 MAR.01 Marker label 1SR 366 017 R0100 CO.01 Sealable transparent cover 1SR 430 005 R0100 Application The is used to monitor three-phase mains for incorrect phase sequence and phase failure. Operating mode Signalling is made by means of the front-face LED. LED Function Output contact closed R: yellow LED ABB

Function descriptions/diagrams Function diagram legend G Control supply voltage not applied / Output contact open / LED off B Control supply voltage applied / Output contact closed / LED glowing Phase sequence and phase failure monitoring If all phases are present with the correct phase sequence, the output relays energize after the start-up delay t s is complete. If a phase failure or a phase sequence error occurs, the output relays de-energize instantaneously. The LED R glows when the output relays are energized. In case of motors which continue running with only two phases, the detects phase failure if the reverse fed voltage is less than 60 % of the originally applied voltage. L1, L2, L3 Measuring value 11-14 11-12 21-24 21-22 R: yellow LED t s L1, L2, L3 L1, L3, L2 L1, L2, L3 L1, L2 L1, L2, L3 L1 L1, L2, L3 t s = start-up delay fixed 500 ms L3 L2, L3 2CDC 252 013 F0208 Connection diagram L1 L2 L3 L1 L2 L3 1115 2125 1216 1418 2226 2428 2226 2125 2428 1216 1115 1418 1SC 110 000 F0118 L1, L2, L3 Control supply voltage = measuring voltage 11 15-12 16 /14 18 Output contacts - 21 25-22 26 /24 28 closed-circuit principle 2 ABB

Type Supply circuit = measuring circuit L1, L2, L3 Rated control supply voltage U S = measuring voltage 3x200-500 AC Power consumption approx. 15 A Rated control supply voltage U S tolerance -15...+10 % Rated frequency 50/60 Hz Duty time 100 % Measuring circuit L1, L2, L3 Monitoring functions phase failure phase sequence Measuring ranges 3x200-500 AC Thresholds U min 0.6 x UN Umax Hysteresis related to the threshold value Measuring voltage frequency 50/60 Hz Response time 500 ms Measuring error within rated control supply voltage tolerance m 0.5 % Measuring error within temperature range m 0.06 % / C Timing circuit Start-up delay t S fixed 500 ms Tripping t - Indication of operational states Relay status R: yellow LED Output relay energized Output circuits 11(15)-12(16)/14(18), 21(25)-22(26)/24(28) Kind of output 2 c/o (SPDT) contacts Operating principle 1) closed-circuit principle Contact material AgNi Rated voltage (DE 0110, IEC 60947-1) 250 Minimum switching voltage / Minimum switching current - / - Maximum switching voltage 250 AC, 250 DC Rated operational current AC12 (resistive) 230 4 A (IEC 60947-5-1) AC15 (inductive) 230 3 A DC12 (resistive) 24 4 A DC13 (inductive) 24 2 A Mechanical lifetime 30 x 10 6 switching cycles Electrical lifetime (AC12, 230, 4 A) 0.1 x 10 6 switching cycles Short-circuit proof, n/c contact 4 A fast-acting max. fuse rating n/o contact 6 A fast-acting AC rating Utilization category (Control Circuit Rating Code) B 300 (UL 508) max. rated operational voltage 300 AC max. continuous thermal current at B 300 5 A max. making/breaking apparent power at B 300 3600/360 A General data Dimensions (W x H x D) 22.5 x 78 x 100 mm (0.89 x 3.07 x 3.94 inch) Mounting DIN rail (EN 50022) Mounting position any Minimum distance to other units horizontal / vertical M 10 mm if the control supply voltage is higher than 415 Degree of protection enclosure / terminals IP50 / IP20 Electrical connection Wire size fine-strand with wire end ferrule 2 x 0.75-2.5 mm² (2 x 18-14 AWG) fine-strand without wire end ferrule 2 x 0.75-2.5 mm² (2 x 18-14 AWG) rigid 2 x 0.5-4mm² (2 x 20-12 AWG) Stripping length 7 mm (0.28 inch) Tightening torque 0.6-0.8 mm Environmental data Ambient temperature range operation / storage -20..+60 C / -40...+85 C Environmental testing (IEC 68-2-30) 24 h cycle time, 55 C, 93 % rel., 96 h Operational reliability (IEC 68-2-6) 4 g Mechanical resistance (IEC 68-2-6) 6 g ABB 3

Type Isolation data Rated insulation volt. between supply, measuring and output circuits (DE 0110, IEC 60947-1) 500 Rated impulse withstand voltage U imp between all isolated circuits (DE 0110, IEC 664) 4 k / 1.2-50 µs Test voltage between all isolated circuits 2.5 k, 50 Hz, 1 min. Pollution category (DE 0110, IEC 664, IEC 255-5) 3 Overvoltage category (DE 0110, IEC 664, IEC 255-5) III Standards Product standard IEC 255-6, EN 60255-6 Low oltage Directive 2006/95/EC EMC Directive 2004/108/EC Electromagnetic compatibility Interference emission EN 61000-6-2 electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3-6 k/ 8 k electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 Level 3-10 /m fast transients (Burst) IEC/EN 61000-4-4 Level 3-2 k / 5 khz powerful impulses (Surge) IEC 1000-4-5, EN 61000-4-5 Level 4-2 kl-l HF line emissission IEC 1000-4-6, EN 61000-4-6 Level 3-10 Interference emission EN 61000-6-4 1) Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold. Technical diagrams Load limit curves AC load (resistive) DC load (resistive) 300 200 100 80 60 50 40 30 20 2CDC 252 194 F0205 300 200 100 80 60 50 40 30 20 2CDC 252 193 F0205 10 0.1 0.2 0.5 1 2 4 6 10 I A 10 0.1 0.2 0.5 1 2 4 6 10 I A Derating factor F Contact lifetime at inductive AC load F 1.0 0.9 0.8 0.7 0.6 0.5 2CDC 252 192 F0205 Switching cycles 250 resistive load 2CDC 252 148 F0206 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Switching current [A] 4 ABB

Dimensions in mm 2CDC 252 031 F0b03 Dimensions - Accessories in mm 4,5.177 62,5 2.46 60 2.36 11,5.453 10.394 22,5.886 2CDC 252 187 F0005 3A11 20.787 8.315 2CDC 252 186 F0005 ADP.01 - Adapter for screw mounting MAR.01 - Marker label 2.70 22,5.886 7.275 3,5.138 2CDC 252 185 F0005 68,5 front-to-back size 107 CO.01 - Sealable transparent cover Further documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C020x CM-PAS,, CM-PSS, CM-PS Instruction manual 1SC 630 510 M0000 You can find the documentation online at www.abb.com/lowvoltage R Control Products R... ABB 5

ABB As part of the on going product improvement, ABB reserves the right to modify the characteristics of the products described in this document. The information given is noncontractual. For further details please contact (www.abb.com/contacts) the ABB company marketing these products in your country. Document number. 2CDC 112 135 D0201 (08/2008) ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82, 69123 Heidelberg, Germany Postfach 10 16 80, 69006 Heidelberg, Germany Internet http://www.abb.com/lowvoltage R Control Products You can find the address of your local sales organisation on the ABB home http://www.abb.com/contacts R Low oltage products