Perceptron Scan Plugin 7.0

Similar documents
Perceptron Plugin. Activating the Perceptron Plugin

Steinbichler T-Scan Plugin

FARO Scanning Plugin

FARO Scanning Plugin

Virtual MODELA USER'S MANUAL

v Overview SMS Tutorials Prerequisites Requirements Time Objectives

v SMS 11.2 Tutorial Overview Prerequisites Requirements Time Objectives

Release Notes. Release Date: March, 2018

2 Solutions Chapter 3. Chapter 3: Practice Example 1

Geomagic Leica Tracker Plug-In 1.0 User s Manual

RapidWorks. What s New for 32-bit and 64-bit versions Build Version March 31, 2014

v Map Module Operations SMS Tutorials Prerequisites Requirements Time Objectives

This guide will help you with many of the basics of operation for your Epson 485wi BrightLink Projector with interactive functionality.

Autodesk Fusion 360 Training: The Future of Making Things Attendee Guide

ENVI Classic Tutorial: 3D SurfaceView and Fly- Through

Getting Started with ShowcaseChapter1:

v SMS 11.1 Tutorial Overview Time minutes

QUICK START GUIDE. SOLO Forest

Training Guide Getting Started with WorkXplore 3D

CHAPTER 1 COPYRIGHTED MATERIAL. Getting to Know AutoCAD. Opening a new drawing. Getting familiar with the AutoCAD and AutoCAD LT Graphics windows

VTube-LASER Quick Start Guide for FARO QUANTUM from a Traditional Tube Print

ezimagex2 User s Guide Version 1.0

GCC vinyl cutter, cutting plotter for sign making

GroBoto v3 SeamNet Mesh Notes

1 - Introduction Training Guide Objectives WorkXplore Environment Importing and Opening CAD Files 5

Autodesk Fusion 360: Render. Overview

CHAPTER. SAToolkit. Clouds. Mesh Vertices

Copyright (C) 2001 Roland DG Corporation

Point Cloud Classification

3DReshaper Help DReshaper Beginner's Guide. Surveying

Working with PDF s. To open a recent file on the Start screen, double click on the file name.

TruEmbroidery Software Program

WallSign TASKE Call Center Management Tools Version 7.0. Table of Contents TABLE OF CONTENTS TASKE WallSign Startup and Shutdown...

STUDIO 12 MANUAL PROCESSING GUIDE

Adobe InDesign CS6 Tutorial

User Manual Version 1.1 January 2015

Included with the system is a high quality speech synthesizer, which is installed automatically during the SymWord setup procedure.

STL Rapid Prototyping

1 - Introduction Training Guide Objectives WorkXplore Environment Importing and Opening CAD Files 5

Advanced Special Effects

VERUS Navigation Guide

This lab exercise has two parts: (a) scan a part using a laser scanner, (b) construct a surface model from the scanned data points.

RLanglois ScanPro 3000 High Definition Microfilm Scanner Help Guide

Part 1: Basics. Page Sorter:

NC Manufacturing Verification

SAS Visual Analytics 8.2: Working with Report Content

SHARP TWAIN AR/DM. User s Guide

Working with Charts Stratum.Viewer 6

Excel 2003 Tutorial II

ntouch for Mac User Guide for Apple OS X Version 3.0 Table of Contents Introducing ntouch for Mac... 2 Quick App Overview... 3

MS Word Professional Document Alignment

Using Smart Search. Understanding Smart Search CHAPTER

SmartArt Office 2007

ADD & FORMAT TABLES POWERPOINT 2010

Unit 2: Managing Views

#61-844SW ThermalVision Software Instruction Manual

VIEWZ 1.3 USER MANUAL

User manual Horus Movie Player 1

Lesson 1 Parametric Modeling Fundamentals

Piping Design. Site Map Preface Getting Started Basic Tasks Advanced Tasks Customizing Workbench Description Index

NC Manufacturing Verification

SOLIDWORKS 2016 and Engineering Graphics

Gexcel. JRC 3D Reconstructor BASIC MEASURING TOOLS

Creating Interactive PDF Forms

Single Menus No other menus will follow necessitating additional user choices

PowerPoint 2016 Building a Presentation

v Mesh Editing SMS 11.2 Tutorial Requirements Mesh Module Time minutes Prerequisites None Objectives

Import, view, edit, convert, and digitize triangulated irregular networks

Gallios TM Quick Reference

Inserting Information into PowerPoint

Advanced Meshing Tools

Bentley Civil Workshop

LOREX Player User Manual Version 1.0

E-Report. User Manual

SharePoint List Booster Features

Creating Fill-able Forms using Acrobat 7.0: Part 1

Software for Observation and Measurement SGMMS V2.6. Users Manual

To build shapes from scratch, use the tools are the far right of the top tool bar. These

A QUICK TOUR OF ADOBE ILLUSTRATOR CC (2018 RELEASE)

The Most User-Friendly 3D scanner

Using LoggerPro. Nothing is more terrible than to see ignorance in action. J. W. Goethe ( )

SEER-3D: An Introduction

FSA Algebra 1 EOC Practice Test Guide

Exacq Mobile. User Manual 9.2. (Updated March 9, 2018)

Contents. Introducing Clicker Paint 5. Getting Started 7. Using The Tools 10. Using Sticky Points 15. Free resources at LearningGrids.

Changing Worksheet Views

HeadMouse. Robotic Research Team. University of Lleida

Secure Guard Central Management System

StickFont v2.12 User Manual. Copyright 2012 NCPlot Software LLC

HeadMouse. Robotic Research Team. University of Lleida

Setting Up Your Drawing Environment

Release Notes. Release Date: July, 2018

Selective Space Structures Manual

To familiarize of 3ds Max user interface and adapt a workflow based on preferences of navigating Autodesk 3D Max.

This Tutorial is for Word 2007 but 2003 instructions are included in [brackets] after of each step.

IMPROVEMENT OF AIRCRAFT MECHANICAL DAMAGE INSPECTION WITH ADVANCED 3D IMAGING TECHNOLOGIES

MobileScan3D. MobileScan3D PlugIn for Geomagic. By Steintek GmbH

This is an example of a data filter which would allow this specific FormImprint user to see those patients with a room number between 135 and 156.

Convert VHS to Digital or DVD using Roxio Video Capture

Files Used in this Tutorial

Transcription:

Perceptron Scan Plugin 7.0 For compatibility with Geomagic products, see Release Notes for Geomagic Perceptron Plugin 7.0. Copyright 2004, Raindrop Geomagic, Inc. Plugins > Perceptron is the interface in Geomagic Studio and Geomagic Qualify to a Perceptron Contour Probe. Perceptron s ScanWorks must be running in the background. The purpose of this (or any) scanner plugin is to eliminate the need to import scan data into Geomagic Studio or Qualify. With the plugin, scanned data exists in the application s Model Manager immediately after the data capture process. In This Document: For a detailed procedure on starting the application and Perceptron equipment, see Activating the Perceptron Plugin on page 1. For details on the elements of the Perceptron plugin dialog, see Controls on the Plugin Dialog on page 2. For details on the three buttons at the end of the arm, see Controls on the Arm on page 6. For a detailed procedure on scanning with Geomagic Studio or Geomagic Qualify, see Step-by-Step Procedure on page 6. Activating the Perceptron Plugin The main point of this procedure is that the ScanWorks software must be running before the Geomagic application is started. 1. Turn on the Perceptron interface box by pressing the power button. Allow up to 90 seconds for startup. 2. Turn on the arm to which the scanner is mounted. 3. Turn on the scanner by pressing the Sensor Power rocker switch on the interface box. 4. Start ScanWorks, typically with a desktop icon. 5. In response to the arm joint dialog, exercise joints on the arm until all all bars are solid blue. When you hear a long tone, the arm is ready. 6. On the ScanWorks interface, at Setup > User Options, verify that the "Output Data to TCP/IP" option is checked. This causes scan data to be captured by ScanWorks but rerouted to the Geomagic application. 7. Verify that a ScanWorks is in the online state. Document Version A October 25, 2004 page 1-1

8. If Geomagic Studio or Geomagic Qualify is not already running, start it now. 9. To activate the scanner control dialog, click the Perceptron icon on the toolbar, or select PlugIns > Perceptron Scan. (This menu item in Geomagic products is an optional, separately licensed feature. If Perceptron does not already appear on the Plugins menu, download the software from support.geomagic.com/downloads, install it according to instructions on the web site, and re-start this procedure.) Controls on the Plugin Dialog This section details the controls and indicators on the user interface of the plugin. Alignment icon button - activates controls and indicators for the alignment process. Every scan must be performed with respect to a known spatial orientation (also called a coordinate system, also incorrectly called an alignment ). The spatial orientation remains in effect on subseqeunt scans and the next time Geomagic Studio or Qualify is started. Define an orientation by one of the following methods. Last Test Model Alignment button (Geomagic Qualify only; selectable only when an object has been designated as the test object) - specifies that the spatial orientation be based on the scheme of the currently designated test object. Load Transform button - allows the user to select a.tfm or.xal file that defines a spatial orientation. Use Arm CSYS button - sets the spatial orientation (also called Coordinate SYStem) to the arm default, where the arm base is the origin. page 1-2 October 25, 2004 Document Version A

Laser icon button - activates controls and indicators for the laser scanner. Object Name field and Reset button - indicates the name of the object that will be stored in the Geomagic model manager. Names are of the form Scan 1, Scan 2, Scan 3,... Reset restores the numeric part to 1. Laser Scanning group - Start Scan button - puts the scanner and software into data collection mode. To return to the application, press the LEFT button on the scanner. To actually begin scanning, press the CENTER button. To pause, press the CENTER button again. Units - specifies the units of measure on the object that will be scanned, such as inches or millimeters. Scanning Options - control the operation of the scanner and the display of data. Shade Points checkbox - By the time a scan is stored in the model manager, the plugin will have calculated individual point normals based on the scanner direction at time of acquisition. This checkbox specifies whether to perform these calculations during pauses (in which case you must wait for a calculation to complete before resuming a scan) or after you press OK to store the object in the model manager (in which case you might have to wait for a relatively long time). Virtual Camera checkbox - toggles the Virtual Camera functionality of the laser scanner. Highlight Scan Pass checkbox - toggles scan pass hi-lighting. When selected, the incoming scan data will appear red, otherwise the incoming scan data will match the light green of previously created scan passes. Display Polygons checkbox - toggles the display between Polygons and Points. Acts on all scan passes in the current plugin instance. Edge Ratio slider (five settings from Low to High) - specifies the propensity of the software to leave gaps between scan lines in the scan image if you are scanning too fast. [A triangle with high edge ratio is one that has two relatively long sides caused by rapid scanning, and a relatively short side which is influenced by the scan line density setting on the FARO Scanner Settings dialog.] When density of scan is more important, such as in a reverse engineering scenario, use a lower Edge Ratio. If you scan too fast, gaps will appear on the scan image. In that case, slow down or make a second pass. Document Version A October 25, 2004 page 1-3

When density of scan is less important, such as some inspection scenarios, use a higher Edge Ratio. If you scan relatively fast and scan lines are far apart, software will triangulate the space between scan lines and thereby suggest that the scan is good. If you are still scanning too fast and gaps appear, slow down or make a second pass. Data Options - affect the appearance of collected data after the plugin is closed. Merge Scan Passes checkbox - specifies whether to perform a point merge on all individual scan passes created during the current session of the plugin. The result will be one point object in the model manager. Sampling checkbox - specifies whether to perform uniform sampling (a reduction of point density) on the resulting point cloud at the end of a scan pass. Spacing - specifies the spacing parameter used by the Uniform Sample operation. Smoothing slider (None, Min, Med, and Max) - specifies whether to perform a smoothing operation on each scan line as it is received from the scanner. The intent is that noisy data can be smoothed in real-time to provide better wrapping results. The values are: None, Min, Med, Max. Filter Angle field (0 to 90 degrees) - offers the ability to ignore points collected by the scanner beyond the specified angle. This results in much cleaner data. The filter angle can be adjusted between 0.0 and 90.0 degrees. This operation, like smoothing, is on a per scan line basis. Real-Time 3D Comparison icon button (visible in Geomagic Qualify, not Geomagic Studio) - activates the laser scanner in a mode that performs real-time 3D comparison of the scanned object to a reference object. Scanner Controls group - is identical to the Laser Scanning group under the Laser icon button, detailed on page 3. Objects group - Reference - indicates the name of the object in the Geomagic model manager that is designated as the Reference object. Scan - indicates that the test object is the New Object that is being scanned. Max. Deviation field - indicates the greatest difference between corresponding reference and test points to allow in the test data. Points beyond this deviation are not included in the test data set. Color Averaging slider (five settings from Low to High) - affects the degree to which colors are blended and averaged across the entire surface, like an airbrush that hides small blemishes. page 1-4 October 25, 2004 Document Version A

Display group - controls various aspects of the graphical display: Test Object checkbox - specifies whether to display the raw test data points during the data capture process. Color radio buttons - specifies the one attribute that will be colored in the Viewing Area: Color Reference - color will appear on the reference object. Color Test Points - color will appear on test points. Color Deviations - color will appear on whisker lines that extend between test points and the reference object. Edit Spectrum checkbox - allows modification of the color coding scheme of the deviation map in the Viewing Area. Edit Texture Resolution checkbox - specifies whether to display the following controls: Texture Resolution group - For the purpose of generating color on the reference object, a grid with uniform cell sizes is placed across its surface. Each square cell is called a texel. Scan points are projected onto the texels. When 0 scan points correspond to a texel, the texel is gray, indicating that the test object has insufficuent data in that region for color to be rendered on the reference object. When one point corresponds to a texel, the texel assumes the color that represents the distance of that scan point from the reference. When two or more scan points correspond to a texel, the texel assumes a color that represents the one point that is furthest from the reference. Resolution dropdown - controls the total number of texels on the surface of the reference object. The choices are: Automatic (the default) - the software selects the number of texels. Fixed Texture Size - the user selects an absolute size of each texel. Fixed Resolution - the user selects an absolute number of texels. The absolute number is of texels is spread across the reference object, which therefore determines the size of each texel. Texture Size dropdown (applicable when Resolution is Fixed Texture Size) - specifies an absolute number of texels, measured in megatexels (millions of texels). Texel Size dropdown (applicable when Resolution is Fixed Resolution) - specifies the absolute width of each square texel, usually in millimeters. Statistics checkbox - specifies whether to include the following indicators: Maximum Distances - indicates the maximum distance between any two corresponding points on the test and reference objects. Average Distances - indicates the average deviation between corresponding points on the test and reference objects. Document Version A October 25, 2004 page 1-5

Standard Deviation - indicates the standard deviation of distances between corresponding points on the test and reference objects. The OK and Cancel buttons described below apply to the Alignment, Laser, and Real-Time 3D Comparison functional areas simultaneously. OK button - For the Alignment function - saves the currently configured alignment. The same alignment will be in effect the next time this plugin is started. For the Laser function - performs any incomplete shading and saves scanned data into the model manager. For the Real-Time 3D Comparison function - saves scanned data into the model manager as a point object named the same as the reference object, designates the point object as the test object, and creates a Result object in the model manager that indicates differences between the test and reference objects. Cancel button - cancels all un-ok d processing in the Alignment, Laser, and Real-Time 3D Comparison functional areas. Controls on the Arm After you press the Start Capture button in the dialog, the arm buttons are enabled and the scanner is in the Paused state. Looking from the elbow toward the laser scanner, the three buttons on the arm are: Left Button - STOP - returns control to the plugin dialog. Center Button - Unpause and Pause - Press once to activate the laser and scan the physical object. Press again to pause the scanner. During the pauses, the application performs shading and sampling (if configured in the plugin dialog) on the data that was just collected. Each cycle of Unpause/Pause generates a uniquely numbered Scan N object in the Geomagic model manager. When a sufficient number of Scans are complete, press the Left button to Stop scanning and return control to the plugin dialog. Right Button - no function. Step-by-Step Procedure Use this procedure to perform a scan with Geomagic Studio or Geomagic Qualify. 1. Select Plugins > Perceptron Scan on the Geomagic Studio or Geomagic Qualify toolbar. 2. Set the values in the ScanWorks dialog appropriately. page 1-6 October 25, 2004 Document Version A

3. Press the Start Capture button in the dialog. If the arm is in the upright/stored position, it issues a continuous tone until you extend it. 4. Notice the laser cursor shining from the scanner head. Hold the scanner above the target object so that the range finder in the Geomagic window indicates a suitable scanning distance. When the blue bar is short, the scanner is too close to the object. When the blue bar fills the range finder, the scanner is too far away. 5. To begin a pass (un-pause the scanner), press and release the middle button on the scanner arm. 6. To complete the pass (pause the scanner), press and release the middle button on the arm again. During the pause, two things happen: Scan data is automatically scaled to fill the Viewing Area. If configured, Sampling and Shading occur on the object(s). 7. To perform additional passes on the same object, go back to Step 5. 8. Press the Left (Stop) button on the arm to stop the capture process and return control to the plugin dialog. 9. On the plugin dialog, press: OK to close the Perceptron Scan plugin. If Merge Objects was checked, OK also merges multiple objects into one object, named Merge N in the model manager. Closing the plugin is the only way to cause the Scan N objects to be merged into one Merge N object in the model manager. Cancel to close the Perceptron Scan plugin without saving any scan data to the model manager. Start Scan again to create additional Scan N objects. Go to step 3. Document Version A October 25, 2004 page 1-7

Last Test Model Alignment with Geomagic Qualify This example demonstrates the use of Last Test Model Alignment in a CAI process with Geomagic Qualify. This assumes a working knowledge of Geomagic Qualify. 1. Load a CAD object into the model manager and designate it as the reference object. 2. Start the scanner plugin. 3. Scan a portion of the object, at least enough points that it could be aligned to the reference object using the best-fit alignment function of Geomagic Qualify. 4. Exit the plugin by clicking the OK button. 5. Use Tools > Alignment > Best Fit Alignment on the test and reference objects (which aligns the reference object with the test object by detecting the similarity of their surfaces. The side effect of this process is that it creates an internal transformation matrix, which is a mapping of the spatial difference between the reference object and the test object. In this case, the transformation matrix represents the spatial difference between the reference object and the place where a test object will lie in the test fixture. 6. Place a real test part in the test fixture. 7. Start the scanner plugin again, and click the Alignment icon. 8. Click the Use Last Test Alignment button. This is a special alignment technique that uses the most recent transformation matrix to specify the spatial difference between the reference object and the test object. The net result is that scan data from the test part will be correctly aligned with the reference object. Next, you will scan the test part. 9. Click the large Laser icon to activate scanning mode. Begin scanning. Scan data appears on the screen in alignment with the CAD reference object. 10. Exit the plugin by clicking the OK button. In the model manager, notice that the newly created scan object is now the test object. 11. To prepare to scan another test object, go to step 7. Every new test object will be aligned correctly. page 1-8 October 25, 2004 Document Version A