SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Similar documents
SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Siemens Industrial s

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Readme SiVArc V14 SP1 Update 6

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SINAMICS G130. Cabinet design and EMC. Operating Instructions 03/2013 SINAMICS

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

Siemens Drives & PLCs

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

Converter SINAMICS G150. Type 6SL37102G

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Siemens Automation Products

ST (6ES7132-6FD00-0BB1)

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

PD PA AP How To Configure Maxum II TimeServer Access

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

Optional package printer driver V1.4

Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface

Manual Edition 03/2010

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

SIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

English. SIMATIC Sensors. RFID-Systems RF600. Getting Started. Edition 11/2005; J31069-D0172-U001-A1-7618

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. Communications processor CP 340 first commissioning steps. Getting Started 04/2005 A5E

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SINAMICS Siemens Controlss

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

SIMATIC. ET 200S distributed I/O. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Preface. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Parameters 2.

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

SIMATIC. Process Control System PCS 7 Symantec Endpoint Protection 11.0 Configuration. Using virus scanners 1. Configuration 2. Commissioning Manual

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

Instruction manual. Output chokes 690V. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

CM PtP RS422/485 BA communication. module (6ES7540 1AB00 0AA0) SIMATIC. S7-1500/ET 200MP CM PtP RS422/485 BA communication module (6ES7540 1AB00 0AA0)

Mechanical Installation Manual SINUMERIK. SINUMERIK 808D Mechanical Installation Manual. Preface. Safety instructions 1. Identification 2.

PROFIenergy product information SIMATIC. ET 200SP PROFIenergy product information. PROFIenergy 1. Product Information 12/2015 A5E AH

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Class:ELOLib 1 COMOS. Platform Class documentation ELOLib_dll. Programming Manual. Siemens Distributor 09/2014 A5E AA

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SIMADYN D Digital Control System. Expansion Module IT41. User Manual. Edition DK No

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Transcription:

SINAMICS G130 Operating Instructions 05/2010 SINAMICS s

Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.3 SP2 05/2010 A5E02142235A

Legal information Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation for the specific task, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed. Trademarks All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY A5E02142235A P 08/2010 Copyright Siemens AG 2010. Technical data subject to change

Table of contents 1 Safety information... 7 1.1 Warnings...7 1.2 Safety and operating instructions...8 1.3 Components that can be destroyed by electrostatic discharge (ESD)...9 2 General... 11 2.1 Safety information...11 3 Mechanical installation... 13 4 Electrical installation... 15 4.1 Overview...15 4.2 Connection diagram...16 4.3 Interface description...17 4.3.1 Electronics power supply X524...17 4.3.2 DRIVE-CLiQ interface X500...18 4.3.3 X520 analog inputs/temperature sensor...18 4.3.4 X521 three-phase line supply voltage sensing up to 100 V (phase-to-phase)...19 4.3.5 X522 three-phase line supply voltage sensing up to 690 V (phase-to-phase)...19 4.3.6 Significance of the LEDs for the Voltage Sensing Module VSM10...20 5 Technical specifications... 21 Operating Instructions, 05/2010, A5E02142235A 5

Table of contents 6 Operating Instructions, 05/2010, A5E02142235A

Safety information 1 1.1 Warnings WARNING Hazardous voltages are present when electrical equipment is in operation. Severe personal injury or substantial material damage may result if these warnings are not observed. Only qualified personnel are permitted to work on or around the equipment. This personnel must be thoroughly familiar with all the warnings and maintenance procedures described in these operating instructions. The successful and safe operation of this device is dependent on correct transport, proper storage and installation, as well as careful operation and maintenance. National safety guidelines must be observed. DANGER Five safety rules When carrying out any kind of work on electrical devices, the "five safety rules" defined in EN 50110 must always be observed: 1. Disconnect the system. 2. Protect against reconnection. 3. Make sure that the equipment is de-energized. 4. Ground and short-circuit. 5. Cover or enclose adjacent components that are still live. NOTICE For a UL-approved system use 60/75 C copper conductors only. Operating Instructions, 05/2010, A5E02142235A 7

Safety information 1.2 Safety and operating instructions 1.2 Safety and operating instructions DANGER This equipment is used in industrial high-voltage installations. During operation, this equipment contains rotating and live, bare parts. For this reason, they could cause severe injury or significant material damage if the required covers are removed, if they are used or operated incorrectly, or have not been properly maintained. When the machines are used in non-industrial areas, the installation location must be protected against unauthorized access (protective fencing, appropriate signs). Prerequisites Those responsible for protecting the plant must ensure the following: The basic planning work for the plant and the transport, assembly, installation, commissioning, maintenance, and repair work is carried out by qualified personnel and/or checked by experts responsible. The operating manual and machine documentation are always available. The technical specifications regarding the applicable installation, connection, environmental, and operating conditions are always observed. The plant-specific assembly and safety guidelines are observed and personal protection equipment is used. Unqualified personnel are forbidden from using these machines and working near them. This operating manual is intended for qualified personnel and only contain information and notes relating to the intended purpose of the machines. The operating manual and machine documentation are written in different languages as specified in the delivery contracts. Note We recommend engaging the support and services of your local Siemens service center for all planning, installation, commissioning and maintenance work. 8 Operating Instructions, 05/2010, A5E02142235A

Safety information 1.3 Components that can be destroyed by electrostatic discharge (ESD) 1.3 Components that can be destroyed by electrostatic discharge (ESD) CAUTION The board contains components that can be destroyed by electrostatic discharge. These components can be easily destroyed if not handled properly. If you do have to use electronic boards, however, please observe the following: You should only touch electronic boards if absolutely necessary. When you touch boards, however, your body must be electrically discharged beforehand. Boards must not come into contact with highly insulating materials (such as plastic parts, insulated desktops, articles of clothing manufactured from man-made fibers). Boards must only be placed on conductive surfaces. Boards and components should only be stored and transported in conductive packaging (such as metalized plastic boxes or metal containers). If the packaging material is not conductive, the boards must be wrapped with a conductive packaging material (such as conductive foam rubber or household aluminum foil). The necessary ESD protective measures are clearly illustrated in the following diagram: a = conductive floor surface b = ESD table c = ESD shoes d = ESD overall e = ESD wristband f = cabinet ground connection g = contact with conductive flooring b d d b d e e f f f f f g a c c a g c a Figure 1-1 ESD protective measures Operating Instructions, 05/2010, A5E02142235A 9

Safety information 1.3 Components that can be destroyed by electrostatic discharge (ESD) 10 Operating Instructions, 05/2010, A5E02142235A

General 2 The Voltage Sensing Module VSM10 is used to operate a permanent-magnet synchronous machine without encoder with the requirement for switching to a machine which is already running (flying restart function). To commission the function, the permanent-field synchronous machine without encoder must be input and "Flying restart" activated with p1200. 2.1 Safety information WARNING The 50 mm clearances above and below the components must be observed. NOTICE The VSM10 has two terminal blocks to sense the three-phase line supply voltage (X521 and X522). The voltage strength of terminal X521 is a maximum of 100 V (phase-to-phase) and is used for voltage sensing via a potential transformer. A maximum voltage to be sensed of up to to 690 V (phase-to-phase) can be directly connected to terminal X522. Only one of the two terminals X521 and X522 may be used. Nothing may be connected to the unused terminal. CAUTION Connecting cables to temperature sensors must always be installed with shielding. The cable shield must be connected to the chassis potential at both ends through a large surface area. Temperature sensor cables that are routed together with the motor cable must be twisted in pairs and shielded separately. Operating Instructions, 05/2010, A5E02142235A 11

General 2.1 Safety information 12 Operating Instructions, 05/2010, A5E02142235A

Mechanical installation 3 Figure 3-1 Dimension drawing of Voltage Sensing Module VSM10 Note The VSM10 is installed near the Power Module on a mounting rail which must be provided by the customer. Operating Instructions, 05/2010, A5E02142235A 13

Mechanical installation 14 Operating Instructions, 05/2010, A5E02142235A

Electrical installation 4 4.1 Overview Figure 4-1 Voltage Sensing Module VSM10 Operating Instructions, 05/2010, A5E02142235A 15

Electrical installation 4.2 Connection diagram 4.2 Connection diagram Figure 4-2 Connection example VSM10 for operation of a permanent-magnet synchronous machine without encoder CAUTION The voltages for the cable to terminal -X522 must be taken downstream of an optional reactor or dv/dt filter, where possible directly at the motor connection terminals. 16 Operating Instructions, 05/2010, A5E02142235A

Electrical installation 4.3 Interface description CAUTION The cable for the -X522 connection must be routed to prevent short-circuiting and ground faults in accordance with IEC 61800-5-2:2007, Table D.1. This can be accomplished, for example, by: Eliminating the risk of mechanical damage to the cables Using cables with double insulation Maintaining adequate clearance, using spacers, for example Routing the cables in separate cable ducts or tubes 4.3 Interface description 4.3.1 Electronics power supply X524 Table 4-1 Terminals for the electronics power supply Terminal Designation Technical specifications + Electronics power supply Voltage: 24 V DC (20.4 V 28.8 V) + Electronics power supply Current consumption: max. 0.2 A Max. current via jumper in connector: 20 A at 55 C M Electronics ground M Electronics ground Max. connectable cross-section: 2.5 mm² Note The two "+" and "M" terminals are jumpered in the connector. This ensures that the supply voltage is looped through. Operating Instructions, 05/2010, A5E02142235A 17

Electrical installation 4.3 Interface description 4.3.2 DRIVE-CLiQ interface X500 Table 4-2 DRIVE-CLiQ interface X500 Pin Signal name Technical specifications 1 TXP Transmit data + 2 TXN Transmit data - 3 RXP Receive data + 4 Reserved, do not use 5 Reserved, do not use 6 RXN Receive data - 7 Reserved, do not use 8 Reserved, do not use A + (24 V) Power supply B M (0 V) Electronics ground Blanking plate for DRIVE-CLiQ interfaces (50 pcs.) Order number: 6SL3066-4CA00-0AA0 4.3.3 X520 analog inputs/temperature sensor Table 4-3 Terminal block X520 Terminal Designation Technical specifications 1 AI 0+ 2 AI 0-3 AI 1+ 4 AI 1-5 + Temp 6 - Temp 2 analog differential inputs +/- 10V to monitor the line filter resonance Resolution: 12 bits Temperature sensor KTY84-1C130 / PTC Max. connectable cross-section: 1.5 mm² DANGER Risk of electric shock! Only temperature sensors that meet the safety isolation specifications contained in EN 61800-5-1 may be connected to terminals "+Temp" and "-Temp". If these instructions are not complied with, there is a risk of electric shock! Note In order to minimize noise emission, shielded cables should be used. 18 Operating Instructions, 05/2010, A5E02142235A

Electrical installation 4.3 Interface description CAUTION The common mode range must not be violated. This means that the analog differential voltage signals can have a maximum offset voltage of +/-30 V with respect to the ground potential. If the range is infringed, incorrect results may occur during analog/digital conversion. 4.3.4 X521 three-phase line supply voltage sensing up to 100 V (phase-to-phase) This interface is not relevant for SINAMICS G130. 4.3.5 X522 three-phase line supply voltage sensing up to 690 V (phase-to-phase) Table 4-4 Terminal block X522 Terminal Designation Technical specifications 1 Phase voltage U Directly connected to sense the line supply 2 Phase voltage V voltage 3 Phase voltage W Max. connectable cross-section: 6 mm² NOTICE Only one of the two terminals X521 and X522 may be used. Nothing may be connected to the unused terminal. NOTICE The phases must be connected to the VSM10 with the same sequence as that of the Power Module. Operating Instructions, 05/2010, A5E02142235A 19

Electrical installation 4.3 Interface description 4.3.6 Significance of the LEDs for the Voltage Sensing Module VSM10 Table 4-5 Significance of the LEDs on the VSM10 LED Color Status Description RDY --- Off The electronics power supply is missing or lies outside permissible tolerance range. Green Steady light The component is ready for operation and cyclic DRIVE-CLiQ communication is taking place. Orange Steady light DRIVE-CLiQ communication is being established. Red Steady light At least one fault is present in this component. Note: The LED is driven irrespective of the corresponding messages being reconfigured. Green / red Flashing, 0.5 Hz Firmware is being downloaded. Flashing, 2 Hz Firmware download is complete. Waiting for POWER ON. Green / orange or red / orange Flashing, 2 Hz Detection of the components via LED is activated (p0144). Note: Both options depend on the LED status when module recognition is activated via p0144 = 1. 20 Operating Instructions, 05/2010, A5E02142235A

Technical specifications 5 General technical specifications Table 5-1 General technical specifications Product standard EN 61800-5-1 Technical specifications Table 5-2 Technical specifications Unit Value Electronics power supply Voltage Current (without DRIVE-CLiQ or digital outputs) Power loss PE/ground connection VDC ADC W <10 On the housing with M4, 1.8 Nm screw Weight kg 1 24 DC (20.4 28.8) 0.3 Operating Instructions, 05/2010, A5E02142235A 21

Siemens AG Industry Sector Drive Technologies Large Drives Postfach 4743 90025 NUREMBERG GERMANY www.siemens.com/automation Subject to change Siemens AG 2010