How to configure the Communication Adaptor for use with the OEM Portal Pro

Similar documents
MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

SMMS i Selection Tool

The PanasonicVRF Driver

Installation Instructions. Procon IP-32M wir-1_ MITSUBISHI ELECTRIC

Introduction... 5 Section 1: iseries Diagnostics... 5 Equipment Required... 5 System Setup... 5 Logging Procedure... 5 Section 2: Updating

IntesisBox PA-AC-MBS-1

Pocket Quick Reference Guide On the TOSHIBA

Unplug the power of your current controller.

GV-I/O Box 4 Ports V1.0 / V1.1

CT-510. Multifunctional CCTV Tester. User Manual

INSTALLATION INSTRUCTIONS

7. PCB AND FUNCTIONS

GV-I/O Box 4 Ports V1.2

INTELLIGENT SERVER. Model: BMS-LSV6E

CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

Instruction Sheet Board Style Low Water Cutoff

Model Instruction Manual. Heat Stress Meter. reedinstruments. www. com

IntesisBox PA-AW-MBS-1 v.2.0

INTERFACE SPECIFICATION

EY-RU : Room operating unit, ecounit

CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

Guardzilla has three ways to add a camera in the app. Scroll to the section that meets your needs. Are you

Specifications and information contained are subject to change without notice. Always refer to install manuals provided with equipment and controls

IntesisBox. v.1.3. User Manual Issue Date: 04/2016. IntesisBox PA-RC2-MBS-4

TH100A User Manual 1 Updated October 12, 2018

EY-RU : Room operating unit, ecounit

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL.

Procon BAC-A/50. Installation Instructions MITSUBISHI ELECTRIC

INSTRUCTION MANUAL A141 High Level Audible Warning System

Pocket Quick. Reference Guide. On the TOSHIBA RBC-AMS51E. Remote Controller

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

Code Dynamics, Inc. Port Splitter

REMOTE CONTROL MYSYSTEM

INSTALLATION INSTRUCTIONS

Installation and Programming Manual. This Manual describes the IBSS InterBus-S Slave, its uses and set up.

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Version-E Manual LDU3000/3000A

FLASH GUI. User Manual V1.4 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

Powerline 200 Plus Home Network Adapter (PL200P)

Technical data sheet Fila LED - FT0110-A4-P FILA LED

Adventurer TM Balances

EY-RU : Room operating unit, ecounit

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

SAMPLE HEAT PUMP WIRING DIAGRAMS

VRF Control System. Judy Ouyang Technical Support Engineer

Gateway Ascii Command Protocol

Thermometer / Barometer System

SMEMA Extension Module

User Guide Automatic Transfer Switch (ATS)

Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA100AMVEB > FVA125AMVEB > FVA140AMVEB

Programmable Logic Controller

The Monitoring Software of Chigo CMV DC Inverter Instruction Manual

Installation & Quick Start Guide iais Wireless AIS Receiver

IntesisBox Modbus Server Panasonic

i.shine 1136 RGBW Color Stainer CN USER MANUAL

User Manual EzLogger WiFi Ver 02

IntesisBox TO-RC-MBS-1

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

PWDBT Bluetooth Mobile Speaker USER GUIDE

Uponor Smatrix Move PRO Controller X-159 Modbus RTU interface

BSH-DRV-1 Bass Shaker Driver Data Sheet (V0.4) BFF Design Ltd

The PC Software can be downloaded from the Arcolectric Web Site:

1:1 Model Connection Interface

VC2100 / VC MB Digital Event Recorder

Screw-in resistance thermometers with terminal head Form B

Welcome to WiFi smart watering

HVAC TECHNICAL BULLETIN

1320 Electronics LLC USB-ALDL Cable User s Guide Electronics LLC. User s Guide for: USB-ALDL Cable

Modbus RTU (EIA-485) Interface for Panasonic and Sanyo air conditioners. Compatible with ECOi and PACi line models.

DIN-RAIL EXPANDER int-iors_en 10/14

F1000 User's Manual. (Version: V1.01)

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Display Real Time Clock (RTC) On LCD. Version 1.2. Aug Cytron Technologies Sdn. Bhd.

ASSEMBLY. - Wind Ring. - Weighing pan (90mm) for 0.1mg model. - Weighing pan (130mm) for 1mg model

IntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.

Delta T Dew Heater for CDK

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

GC-10 Wireless Control Box. User Guide

Indoor Unit Controller (IUC) Quick Reference and Fault Diagnosis

Quick Guide. Extra Communication Card

Fle F xs le y xs s y C s on C tr on oller

High Efficiency LED Driver DCCP-DPR Series USER MANUAL. This manual offers important information and suggestions with

[19A4:225C][ T17:59:21]i000: Initializing string variable 'DOTNETHOME' to value '[ProgramFiles6432Folder]dotnet'

New ADAP-KOOL AK-CT 200. One. Hardware. for over 300 tray variants. Refrigeration and A/C Controls Division Date 1

Trouble shooting the DeskCNC controller:

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Single phase. Technical Support Division

TouchKit Touch Panel User manual for Windows9X/ME Version: 3.1.4

Wireless RS485 for KACO Link

Version 1.0c May 6, 2010 ATK3

for M-Bus, Modbus and 1-Wire devices

eblocks A Adaptor Board datasheet Matrix Multimedia Adaptor Board Contents

Lossnay Remote Controller

Controller Pro Instruction Manual

DESIGN & TECHNICAL MANUAL

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

Instructions for USB Tester with Full Colour Display

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

Contents. GV-I/O Box 8 Ports Key Features Compatible Software Packing List Overview DIP Switch...

Transcription:

How to configure the Communication Adaptor for use with the OEM Portal Pro When using an OEM Prtl Pro for a Building Automation System (BAS) the Communication Adaptor is necessary for the front-end to communicate with Sanyo ECO-i equipment Care must be taken to follow the configuration that was programmed into the OEM Prtl Pro via the Configuration Sheet and the Piping Diagram that was supplied to you If the information we receive is not correct the program in the OEM Prtl Pro will not properly communicate (read or write) to the equipment Please read this entire document before performing any of the procedures Fig 1 (Communication Adaptor Layout)

As an example; Refrigerant Circuit #1 has (15) indoor units with (2) outdoor units and Refrigerant Circuit #2 has (10) indoor units with (1) outdoor unit The OEM Prtl Pro was programmed to see RC #1 on link 1 and RC #2 on link 2 of the Communication Adaptor, the appropriate Refrigerant Circuit has to land on the correct link or the OEM Prtl Pro will not communicate with the equipment For an example of the wiring for this type of configuration please Fig 2 A) Setting the Communication Adaptor to scan for indoor units and outdoor units 1 The Communication Adaptor has 4 buttons below the LED display The buttons are Home, Up, Down and Set These buttons are used to configure the Com Adaptor (Fig 1) 2 Move the Terminal Resistance plug (CN32) on the Communication Adaptor to the B position 3 Turn the Communication Adaptor on 4 Press and hold <Home> button for 2-3 seconds, the display will show and then change to 5 Press the <Up> button 5 times and the display will change to 6 Press the <Set> button and the display will show 7 Press the <Down> button and the display will now show 8 Press the <Set> button until the last digit (0) begins to blink 9 Press the <Down> button and the display changes to 10 Press the <Set> button until the last digit (3) stops blinking 11 Now cycle power on the communication adaptor 12 Upon restarting the communication adaptor will begin scanning links 1 and 2 for indoor and outdoor units The display will alternately show and If everything is correct, using the example above the Communication Adaptor s 6 digit display will show 000215 and then 010110 when it has completed scanning These numbers represent: Refrigerant Circuit #1 00=Link number 1 on the Communication Adaptor 01=Total number of outdoor units 15=Total indoor units on Refrigerant Circuit 1 Refrigerant Circuit #2 01=Link number 2 on the Communication Adaptor 02=Total number of outdoor units 10=Total indoor units on Refrigerant Circuit 2

B) Using the Communication Adaptor to set Central Control Address 1 We have now confirmed that the Communication Adaptor is seeing all the units to be controlled by the OEM PP 2 At this point if a Central Control Address has not been assigned, you will have to set the Central Control Address If the Central Control Address has been set you do not have to perform this portion of the configuration Please go to Setting the Communication Adaptor not to scan for indoor units and outdoor units 3 You may set the Central Control Address with the System Controller or Intelligent controller instead of using the Communication Adaptor 4 Press and hold <Home> button for 2-3 seconds, the display will show and then change to 5 Press the <Up> button 4 times, the display will now show 6 Press the <Set> button and the display will change to 7 Press the <Down> button 2 times, the display will now show 8 Press the Set button for 2-3 seconds and when the Communication Adaptor has completed setting the Central Control Address the display will show Now that the Central Control address has been set, you will have to change the Communication Adaptor configuration so that it does not scan on a power up C) Setting the Communication Adaptor not to scan for indoor units and outdoor units 1 Press and hold <Home> button for 2-3 seconds, the display will show and then change to 2 Press the <Up> button 5 times and the display will change to 3 Press the <Set> button and the display will show 4 Press the <Down> button 1 time, the display shows 5 Press and hold the <Set> button until the last digit (3) begins to blink 6 Press the <Down> button and the display changes to 7 Press the <Set> button until the last digit (0) stops flashing At this point the Communication Adaptor has configured to work with the OEM Prtl Pro Turn the power on to the OEM Prtl Pro and use BacView to confirm that it is correctly reading the temperature from the indoor unit If the BacView is reporting 50 degree temperatures in the space, the OEM Prtl Pro or the Communication Adaptor is not setup correctly

D) Configure the Communication Adaptor, OEM Prtl Pro with an Intelligent Controller This procedure should only be performed if you have an Intelligent Controller with an OEM Portal Pro on the same system The OEM Prtl Pro must be programmed for this type of configuration, if the OEM Prtl Pro has not been programmed and you perform this procedure, you will lose the ability to read or write to the Sanyo units This procedure must be performed before all other procedures in this document For an example of the wiring for this type of configuration please Fig 3 1 Move the Terminal Resistance plug (CN32) on the Communication Adaptor to the B position 2 Turn the Communication Adaptor on 3 Press and hold <Home> button for 2-3 seconds, the display will show and then change to 4 Press the <Up> button 5 times and the display will change to 5 Press the <Set> button and the display will show 6 Press the <Up> button 2 times, the display will show 7 Press the <Set> button for 1-3 seconds until the last digit (0) begins to blink 8 Press the <Up> button 3 times, the display will now show the last digit blinking (3) 9 Press and hold the <Set> button until the last digit stop blinking 10 Press the <Up> button once, the display will show 11 Press the <Set> button for 1-3 seconds the last digit (0) will begin blinking 12 Press the <Up> button once to change the last digit from (0) to (1) 13 Press the <Set> button until the last digit (1) stops blinking 14 Press the <Up> button once, the display will now show 15 Press and hold the <Set> button until the last digit (0) starts blinking

16 Press the <Up> button once to change the last digit from (0) to (1) 17 Press the <Set> button until the last digit (1) stops blinking 18 Cycle power on the Communication Adaptor and perform steps A through C Fig2 (Typical Wiring of the Communication Adaptor and the OEM Prtl Pro)

Fig 3 (Typical Wiring of the Communication Adaptor, OEM Prtl Pro and an Intelligent Controller) BACnet/IP or BACnet/Ethernet line 24V AC RS485 line to Net+ and Net- 100~240V AC Power 100~240V AC Power RS485 line to 11 and 12 U1-U2 line to 0 and 1(Link1) or 3 and 4(Link2) U1-U2 line up to 64 indoor units on one link