PHOENIX CONTACT - 01/2008

Similar documents
PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 12/2007

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-24VDC

PHOENIX CONTACT - 02/2008

MACX MCR-EX-SD LP(-SP)

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-CVS NC

EC-E1 10A. Extract from the online catalog. Order No.: Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 10 A

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

DT 2,5. Extract from the online catalog. Order No.:

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

MACX MCR-EX-SL-NAM-R(-SP)

MACX MCR-EX-SL-NAM-2RO(-SP)

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

UK 5-MTK-P/P. Extract from the online catalog. Order No.:

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

PLC-RSC- 24DC/21 Order No.:

ETD-BL-1T-OFF-CC- 10S

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.:

Extract from the online catalog

STTB 2,5. Extract from the online catalog. Order No.:

PLC-RSC- 24DC/21. Extract from the online catalog. Order No.:

PLC-OSC-120UC/ 24DC/ 2

VAL-CP-3S-350. Extract from the online catalog. Order No.:

UT 2,5-PE. Extract from the online catalog. Order No.:

Extract from the online catalog

MINI MCR-SL-PT100-UI(-SP)(-NC)

PLC-RSC- 24DC/ Extract from the online catalog. Order No.:

UK 5-HESILA 250. Extract from the online catalog. Order No.:

Extract from the online catalog

ST 2,5. Extract from the online catalog. Order No.:

Extract from the online catalog

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-MUX-V8-FLK 16

UK 5 N BU. Extract from the online catalog. Order No.:

MBKKB 2,5-PV. Extract from the online catalog. Order No.:

DIK 1,5. Extract from the online catalog. Order No.:

DOK 1,5-2D. Extract from the online catalog. Order No.:

PIT 2,5-TWIN. Extract from the online catalog. Order No.:

UK 10-DREHSI (6,3X32)

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

UT 4-HESILA 250 (5X20)

PLC-OPT-230UC/ 24DC/2

PLC-OSC- 24DC/ 48DC/100

MKKDS 1/ 4-3,81. Extract from the online catalog. Order No.:

UK 6 N. Extract from the online catalog. Order No.:

SMKDS 1/ 4-3,81. Extract from the online catalog. Order No.:

DIK 1,5-LA 24RD/U-O. Extract from the online catalog. Order No.:

Redundancy Module QUINT-DIODE/40

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

UK 6,3-HESI. Extract from the online catalog. Order No.:

SUBCON-PLUS-PROFIB...

UK 5-TWIN. Extract from the online catalog. Order No.:

PLC-OPT- 24DC/230AC/1

MCVW 1,5/ 2-ST-3,81. Extract from the online catalog. Order No.:

PC 4/ 6-ST-7,62. Extract from the online catalog. Order No.:

Extract from the online catalog

UDK 4-DUR. Extract from the online catalog. Order No.:

ST 4. Extract from the online catalog. Order No.:

UK-SI. Extract from the online catalog. Order No.:

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

UT 6. Extract from the online catalog. Order No.:

PIT 2,5-QUATTRO-PE. Extract from the online catalog. Order No.:

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

UK 10-PLUS. Extract from the online catalog. Order No.:

MCVR 1,5/ 3-ST-3,81. Extract from the online catalog. Order No.:

UKH 50. Extract from the online catalog. Order No.:

UKKB 10. Extract from the online catalog. Order No.:

FRONT-MC 1,5/ 4-ST-3,81

UDK 4. Extract from the online catalog. Order No.:

MC 1,5/14-ST-3,81. Extract from the online catalog. Order No.:

STEP-PS/1AC/24DC/1.75

PIT 2,5-TWIN-DIO/R-L. Extract from the online catalog. Order No.:

GMSTB 2,5/ 4-ST-7,62. Extract from the online catalog. Order No.:

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

Extract from the online catalog

FLEX Ex Spring Clamp Terminal Base

Extract from the online catalog

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

MSTB 2,5/ 2-STF-5,08. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 07/2006

UKK 5-TG. Extract from the online catalog. Order No.:

MSTB 2,5/ 5-STF-5,08. Extract from the online catalog. Order No.:

UTI 16-PE. Extract from the online catalog. Order No.:

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description

UKK 5-DIO/U-O. Extract from the online catalog. Order No.:

QUINT-PS-3x AC/24DC/10

PT 1,5/S-TWIN. Extract from the online catalog. Order No.:

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

UTME 6. Extract from the online catalog. Order No.:

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

PT 1,5/ 3-5,0-H. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Transcription:

Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex basic terminal blocks are used as base elements for the wiring for plug-in PI Ex modules. The base elements can be snapped onto the popular EN DIN rails. They must be installed in the safe area or zone 2. The signal cables are connected to the module safely using screw connections. The integrated test sockets and isolating connectors enable devices for measurements, loop checks, and calibration tasks to be coupled in the current loop without interrupting the signal path. The PI-EX-TB/T basic terminal block has integrated cold junction compensation and is therefore used as the base element for the PI-EX-THC-I (Order No. 2835079) and PI-EX-THC-I-NC (Order No. 2835600) temperature measuring transducers. NOTE: The PI-EX-TB/T basic terminal block is not suitable for the PI-EX-RPSS-I/I, PI-EX-DO/REL-S, and PI-EX-RTD-I electronic modules. 1.1 Properties Single-channel Integrated test sockets Integrated isolating connectors Integrated cold junction compensation with the PI-EX-TB/T Installation in zone 2 The device is an associated item of equipment. It is designed for use in zone 2, if the specific conditions are observed. When installing and operating the device, the applicable safety directives (including national safety directives), accident prevention regulations, as well as general technical regulations, must be observed. Observe the safety regulations and installation notes on page 4. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. This data sheet is valid for all products listed on the following page:

Table of Contents 1 Description... 1 2 Ordering Data... 2 3 Technical Data... 3 4 Safety Regulations and Installation Notes... 4 5 Structure... 5 6 Installation... 5 7 Isolation and Testing Options... 6 8 PI-EX-TB/T Method of Operation... 6 2 Ordering Data Basic Terminal Blocks Ex basic terminal block for intrinsically safe signals with knife disconnection and test connections Ex basic terminal block for intrinsically safe signals with knife disconnection and test connections for the PI-Ex-THC-I(-NC) temperature measuring transducer PI-EX-TB 2835901 1 PI-EX-TB/T 2835927 1 Bridges Continuous plug-in bridge, 500 mm long, insulated, can be cut to length, for potential distribution with PLC... Blue FBST 500-PLC BU 2966692 1 Gray FBST 500-PLC GY 2966838 1 Red FBST 500-PLC RD 2966786 1 Marking Zack marker sheet, flat, 100-section, for all terminal blocks with a pitch of 6.2 mm, color: white Printed horizontally with consecutive numbers from 1-100 ZBFM 6/WH,LGS:1-100 0800284 1 Printed horizontally with consecutive numbers from 1-10, 11-20, etc. ZBFM 6/WH,LGS:FORTL.ZAHLEN 0803621 1 up to 91-100, 10 identically labeled strips per flat Zack marker sheet Unprinted: 10 strips with 10 labels each, sufficient for 100 terminal blocks ZBFM 6/WH:UNBEDRUCKT 0803618 1 Labeled according to customer specifications, can be separated ZBFM 6:SO/CMS 0803650 1 Assembly Insulating plate, 2 mm thick, black, must be installed at the start and end of each PI terminal strip, if continuous plug-in bridges are used. PI-ATP 2835969 1 Connectors/Adapters Insulating sleeve for MPS metal part to be ordered separately (0201744) Blue MPS-IH BU 0201689 1 Gray MPS-IH GY 0201728 1 Red MPS-IH RD 0201676 1 102957_00_en PHOENIX CONTACT 2

Tools Screwdriver, bladed, with graduated blade, suitable for all screw terminal blocks with a diameter of 2.3 mm, test socket screws and test sockets, blade width: 3.5 mm SZG 0,6X3,5 1205121 1 For additional accessories, please refer to the "INTERFACE" catalog from Phoenix Contact. 3 Technical Data Connection Data Conductor cross-section Solid (minimum/maximum) Stranded (minimum/maximum) AWG/kcmil (minimum/maximum) Stripping length Thread Connection method Tightening torque 0.2 mm 2 /2.5 mm 2 0.2 mm 2 /2.5 mm 2 24/14 12 mm M3 Plug-in screw connection 0.5 Nm, minimum/0.6 Nm, maximum General Data Nominal voltage U N Nominal current I N Housing material Color Degree of protection Dimensions Without electronic module (width x height x length) With electronic module (width x height x length) Inflammability class according to UL 94 Ambient temperature (operation) EC Conformance EMC directive 89/336/EEC Ex directive (ATEX) 20 V... 30 V 250 ma (depends on the plugged-in module) PBT Gray IP20 12.4 mm x 86.5 mm x 145 mm 12.4 mm x 147 mm x 145 mm V0-20 C +60 C Yes Yes Safety Data According to ATEX for Intrinsically Safe Circuits Intrinsically safe input or output circuit (+, -), U 30 V (90 V when using the PI-ATP insulating plate, Order No. 2835969) Power supply (UB+, UB-), U m Non-intrinsically safe circuit (+, -), U m Effective internal capacitance Effective internal inductance Approvals 265 V AC, Ι < 4 A 265 V AC, Ι < 4 A ATEX X II (1) GD [EEx ia] IIC, KEMA 01 ATEX 1231 X II 3G Ex na II T4X 1 nf 1 μh 102957_00_en PHOENIX CONTACT 3

4 Safety Regulations and Installation Notes 4.1 Installation and Operation Follow the installation instructions. NOTE: Installation, operation, and maintenance may only be carried out by qualified specialist personnel. When installing and operating the device, the applicable safety directives (including national safety directives), accident prevention regulations, as well as general technical regulations, must be observed. NOTE: Installation, operation, and maintenance may only be carried out by qualified specialist personnel. Do not repair the device yourself, replace it with an equivalent device. Repairs may only be carried out by the manufacturer. NOTE: The device is designed to meet IP20 protection when: It is installed outside potentially explosive areas. The environment is clean and dry. In order to provide protection against mechanical or electrical damage, install the device in corresponding housing with a suitable degree of protection according to IEC 60529. 4.2 Safety Regulations for Installation in Potentially Explosive Areas Regulations for Intrinsically Safe Circuits When carrying out measurements on the intrinsically safe side, observe the relevant regulations regarding the connection of intrinsically safe equipment. Only use devices approved for use in intrinsically safe circuits. If the device has been used in non-intrinsically safe circuits, it must not be used again in intrinsically safe circuits. The module must be clearly labeled as non-intrinsically safe. For the safety data, please refer to the operating instructions and certificates (EC-type examination, other approvals, if necessary). Installation in Zone 2 The device is an associated item of equipment with "intrinsically safe" explosion protection and is designed for installation in zone 2, if the symbol is printed on the block. Observe the specified conditions for use in potentially explosive areas. Install the device in suitable housing that meets IP54 protection, minimum. Observe the requirements of IEC 60079-14/ EN 60079-14, e.g., steel housing with a wall thickness of 3 mm. Disconnect the block power supply before: Snapping it on or disconnecting it. Connecting or disconnecting cables of non-intrinsically safe circuits. Only use category 3G PI EX modules (ATEX 94/9/EC). Installation in Areas With a Danger of Dust Explosions The device is not designed for use in areas with a danger of dust explosions. Connection to the intrinsically safe circuit in areas with a danger of dust explosions (zone 20, 21, and 22) is only permitted if the equipment connected to this circuit is approved for this zone (e.g., category 1D, 2D or 3D). 4.3 Use in Safety-Related Applications When using the PI-EX-TB in safety-related applications, observe the requirements specified in the data sheets for the relevant modules. 102957_00_en PHOENIX CONTACT 4

5 Structure 1 8 2 Figure 1 Structure 1 Field signal "+" (Ex area) 2 Field signal " " (Ex area) 3 Signal "+" (non-ex) 4 Signal " " (non-ex) 1-4 Terminal screw with integrated test socket 5 Voltage supply "+", UB+ 6 Voltage supply " ", UB 7 Isolating connectors 8 Test sockets 9 Holder for keying pin Dimensions + - - + - + 7 9 9 UB+ UB- + - + - 3 5 4 UB + UḆ 6 UB+ UB- UB+ UB- 145 12.4 6 Installation NOTE: Electrostatic discharge The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 61340-5-1 and EN 61340-5-2. When used as equipment in zone 2, the electronic module must not be disconnected from the base element when connected to the power supply. Cables of non-intrinsically safe circuits must only be connected and disconnected when the power is disconnected. 6.1 Basic Terminal Block Wiring The PI-EX-TB and PI-EX-TB/T basic terminal blocks can be snapped onto popular EN DIN rails. On the field side (intrinsically safe side), the sensors and limit switches are connected to the terminal points marked "+" and "-" (1 and 2). On the system side, the cables are inserted into the terminal points marked "+" and "-" on the top of the terminal block (3 and 4). The power supply is connected to the connection terminal blocks marked "UB-" and "UB+" (5 and 6). When several PI basic terminal blocks are installed side-by-side, power can be supplied using FBST 500-PLC plug-in bridges. 147 If the device has been used in non-intrinsically safe circuits, it must not be used again in intrinsically safe circuits. The module must be clearly labeled as non-intrinsically safe. 86.5 Figure 2 Dimensions (in mm) 102957_00_en PHOENIX CONTACT 5

6.2 Automatic Keying of Electronic Modules The basic terminal block is not keyed by default upon delivery. The user-friendly keying is located in the electronic module and consists of four plastic parts, which are joined together. When the electronic module is first removed, the lower part of the keying pins remains in the basic terminal block (9 in Figure 1 on page 5). In this way, it is automatically keyed to the relevant electronic module. If an electronic module is accidentally inserted in the wrong place, any plastic parts remaining in the basic terminal block can be removed using a screwdriver. 7 Isolation and Testing Options On the field side, the circuit can be interrupted by two isolating connectors (7 in Figure 1 on page 5). The intrinsically safe circuits can also be isolated when the power is connected. Both screws (1 and 2) are designed as test connectors, which means that both the voltage and current can be measured. Furthermore, additional test sockets (8) are located behind the isolating connectors, which enable the current to be measured without interrupting the measuring process. The two screws on the system side (3 and 4) are also designed as test connectors, which means that the voltage can be measured. 8 PI-EX-TB/T Method of Operation The PI-EX-TB/T basic terminal block is used as the basic terminal block for the PI-Ex-THC-I(-NC) temperature measuring transducer when measuring temperatures with thermocouple sensors. Figure 3 Temperature measurement A PT100 sensor integrated in the area of connection points 1 and 2 records the temperature of the corresponding clamping part. The basic terminal block transmits this signal to the electronic module via the spring fork contacts. Cold junction compensation is then carried out in the electronic module. 102957_00_en PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany Phone: +49-52 35-30 0 6 PHOENIX CONTACT P.O.Box 4100 Harrisburg PA 17111-0100 USA Phone: +717-944-1300 www.phoenixcontact.com