Diffusion Mapping with FireVoxel Quick Start Guide

Similar documents
BrainMask. Quick Start

BrainMask. Quick Start

Brain Mask User s Guide

fmri/dti analysis using Dynasuite

Introduction to Microsoft Office PowerPoint 2010

Learn Image Segmentation Basics with Hands-on Introduction to ITK-SNAP. RSNA 2016 Courses RCB22 and RCB54

Contents... 1 Installation... 3

Instructions for Display of Imaging Studies Using Stentor isite

DIFFUSION TENSOR IMAGING ANALYSIS. Using Analyze

Microsoft Office Word. Help. Opening a Document. Converting from Older Versions

Pre-Lab Excel Problem

UGviewer: a medical image viewer

Virtual Frap User Guide

icatvision Quick Reference

Quick Start Guide - Contents. Opening Word Locating Big Lottery Fund Templates The Word 2013 Screen... 3

Word 2010 Beginning. Technology Integration Center

Display Systems International Software Demo Instructions

How to...create a Video VBOX Gauge in Inkscape. So you want to create your own gauge? How about a transparent background for those text elements?

BASICS OF MOTIONSTUDIO

Microsoft Office Excel

Word 2013 Beginning. Technology Integration Center

Microsoft PowerPoint 2013 Beginning

HOW TO SETUP AND RUN SHIVA...

IDL Tutorial. Working with Images. Copyright 2008 ITT Visual Information Solutions All Rights Reserved

Table of Contents Welcome to Menu.Applet... 2 Why Java -based menus?... 2 Basic terminology... 2 Getting to know Menu.Applet... 4 Creating a new menu

Getting Started with DADiSP

The Mathcad Workspace 7

ClinicalConnect TM eunity TM Training Guide

TexGraf4 GRAPHICS PROGRAM FOR UTEXAS4. Stephen G. Wright. May Shinoak Software Austin, Texas

The LabScribe Tutorial

XnView Image Viewer. a ZOOMERS guide

HydroOffice Diagrams

XnView 1.9. a ZOOMERS guide. Introduction...2 Browser Mode... 5 Image View Mode...15 Printing Image Editing...28 Configuration...

1 Place the iworx/214 unit on the bench, close to the computer. 3 When the dialog box appears, select ahk214.iws and then click Load.

Introduction to Adobe Premiere 5.1. Creating a New Project and Capturing Clips. Editing Digitized Clips. Reviewing and Exporting the Final Movie Clip

DDX-R Quick Start Guide

Experiment 1: The LabScribe Tutorial

MS Excel Henrico County Public Library. I. Tour of the Excel Window

Gloucester County Library System EXCEL 2007

Quick Start Guide Jacob Stolk PhD Simone Stolk MPH November 2018

Sending image(s) to report Click Send Snapshot on any screen in Dolphin3D and choose the Send to Report option

Vision Pointer Tools

Learning to use ProAnalyst

Bombardier Business Aircraft Customer Services. Technical Publications. SmartPubs Viewer 3.0 User Guide. Updated January 2013 [2013]

Logger Pro Resource Sheet

PowerPoint 2016 Building a Presentation

The Fundamentals. Document Basics

Word 2007: Flowcharts Learning guide

Chapter 7 Inserting Spreadsheets, Charts, and Other Objects

Part 1: Basics. Page Sorter:

Premiere Pro Desktop Layout (NeaseTV 2015 Layout)

OnPoint s Guide to MimioStudio 9

Microsoft PowerPoint 2010 Beginning

Introduction to Microsoft PowerPoint 2000

SISCOM (Subtraction Ictal SPECT CO-registered to MRI)

Metrics Tutorial. Table of Contents. 1. Introduction

Using Blending Modes for Simple Color Correction

n o r d i c B r a i n E x Tutorial DTI Module

Keynote 08 Basics Website:

MS Excel Henrico County Public Library. I. Tour of the Excel Window

3DMMVR REFERENCE MANUAL V 0.81

Excel Tutorial 1

Developer s Tip Print to Scale Feature in Slide

The gray notepad indicates that no note or report is attached to the study.

Review other manuals that may assist you in navigating and using the Kettering CAFM website. Follow these steps to retrieve the user guides:

Gloucester County Library System. Excel 2010

Correcting Grammar as You Type. 1. Right-click the text marked with the blue, wavy underline. 2. Click the desired option on the shortcut menu.

AutoCollage 2008 makes it easy to create an AutoCollage from a folder of Images. To create an AutoCollage:

Microsoft PowerPoint 2007 Beginning

IMAGE STUDIO LITE. Tutorial Guide Featuring Image Studio Analysis Software Version 3.1

use selection tools, layers & masks in PhotoPlus X4 Faking it! Combine three source photos and add text to create a composite image or montage.

User Manual Version 1.1 January 2015

Quick Guide for Photoshop CC Basics April 2016 Training:

Introduction to Microsoft Word 2007 Quickguide

Microsoft Office Publisher

Intelligent Security & Fire Ltd

Quick Guide Software Version 4.4

DataPro Quick Start Guide

Contents. Launching Word

Excel Core Certification

Data Loading & 3D Visualization

Chapter 2 Using Slide Masters, Styles, and Templates

Quick Reference Guide

Exercise 5 Animated Excel Charts in PowerPoint

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

TexRAD Research Version Client User Guide Version 3.9

Introduction Make a plan with tool Rectangle Measurements Toolbar Enter Return Measurements Toolbar Measure Protractor

Microsoft Word 2010 Basics

Using Inspiration 7 I. How Inspiration Looks SYMBOL PALETTE

EXERCISE 2: GETTING STARTED WITH FUSION

Rat 2D EPSI Dual Band Variable Flip Angle 13 C Dynamic Spectroscopy

Numbers Basics Website:

Correcting Grammar as You Type

Session 7 MS Word. Graphics. Inserting Clipart, and Graphics Modify graphics Position graphics

LinkMotion and CorelDraw 9, 10, 11, 12, X3, X4, X5, X6, X7 and X8:

Interactive Powerpoint. Jessica Stenzel Hunter Singleton

June 05, 2018, Version 3.0.6

Application of Skills: Microsoft PowerPoint 2013 Tutorial

Exercise 2: Bike Frame Analysis

Optimizing ImmuNet. In this chapter: Optimizing Browser Performance Running Reports with Adobe Acrobat Reader Efficient Screen Navigation

Transcription:

Diffusion Mapping with FireVoxel Quick Start Guide Medical image analysis tool developed by Artem Mikheev and Henry Rusinek Radiology Department, NYU School of Medicine Original version prepared by Jinyu Li, July 2, 2010 this version Dec 7, 2013 FireVoxel (FV) is a MS Windows software for visualizing and analyzing medical images. The main types of data analyzed by FireVoxel are: 3D volumes resulting from acquisitions MRI, CT, PET, SPECT instruments 4D datasets, typically representing a dynamic time series of 3D volumes. 3D/4D ROIs linked to above data Installation https://files.nyu.edu/hr18/public/ is a web page from which you can download the software, quick guides, and sample data. For the initial installation Download FireVoxel.zip from the link FireVoxel * full Extract files from FireVoxel.zip to a new folder. This will include readme.txt Run vcredist_x86.exe if needed Launch FireVoxel.exe Paste your computer ID to the email addressed to hr18@nyu.edu The reply will include FireVoxel.key to be saved in your folder To upgrade to the newest version, download from the link FireVoxel * upgrade, extract new version files, and overwrite your older files. There is no need for a new FireVoxel.key This guide was done on FV version (or build) 127. Click on Help>About this Application to see the build number.

Introduction This quick Start Guide shows how to process dynamic (or 4D) datasets and generate voxel-based parametric maps. Our example is the MRI based measurement of water diffusion in renal lesions. Diffusion, or randomized microscopic movement of water molecules, can be useful to characterize the tissue. Diffusion MRI is performed using strong bipolar pulses called diffusion gradients. Their strength is measured with b-values (units of s/mm 2 ). While diffusion-weighted MRI is highly sensitive to motion (patient motion, breathing), with modern equipment radiologists are successful in measuring tissue diffusion even for abdominal evaluations. MRI measurements of water diffusion coefficient are affected by temperature and magnetic properties of the tissue. We therefore use the term "apparent diffusion coefficient" or ADC (units of mm 2 /s). To compute ADC we acquire a series of volumetric images, each volume at a different b-value. ADC is solved by fitting theexponsntial formula: SI(b) = SI(0) exp(-b ADC), where SI(b) is the signal intensity for a given b, to measured data. Please download and expand MRI diffusion files diffusion_sample.zip to continue this guide. Step 1 When you start FV you will see its main window, the toolbar on the right margin and only a few menu items, including File and Help. The gray document area is initially empty. Make sure that the vertical resolution of your screen is fine enough to show the entire toolbar. Step 2 To analyze water diffusion we will use kidney MRI dataset diffusion_sample providede in a DICOM file format. You will need to unzip the file into an empty folder before loading it into FV. Then go to File item of the main menu and select the Open DICOM Single submenu. Browse for Folder dialog box will now appear in order to navigate to a folder that contains your (unzipped) sample dataset. You may also select a higher-level folder, but the higher the level, the longer it will take to load. Step 3 DICOM Tree dialog box will next appear. This is a hierarchy typically organized by PATIENTS, then by STUDIES, then SERIES. Our diffusion data is very simple, containing a single series named AX MULTI b Diffusion. This series is marked with a green VL for volume list. When we expand it, we see a list of 8 volumes. As you click on the volume names (#0 #1 etc) you will see its middle slice previewed in the upper right. Under the preview slice you will see a summary of acquisition parameters for the current volume. The corresponding b-values are shown at the bottom of the summary table. Highlight the first volume, the one with b-value = 0, and press Load 4D Range button, then hit OK. This will load all 8 volumes and create a document. 2

FireVoxel contains several other methods for loading dynamic (4D) datasets. For example, we can mark the desired volumes by checking the squares located at the left. We then highlight the SERIES that contains all volumes, and click Load Siblings and Descendants button. The squares are also used to copy part of your DICOM data to another folder or to permanently delete DICOM files. To delete images, check the corresponding squares and click on the Delete button located at the bottom of the DICOM Tree dialog box. To make a copy, make a destination folder, select the desired volumes by checking the squares, and hit Copy button. Step 4 The Document window will appear inside the main window. Some new menu items (Volume, ROI, 4D Processing) will now appear. Position the mouse cursor on the first slice and right double-click to switch to a Single Slice view. Repeating right double-click brings you back to the Film View. In Single Slice view, use the mouse scroll wheel or the keyboard up/down arrow keys to view different slices. Use left/right arrow keys to scroll across different b-values, this can be done in both Film view and Single Slice view. B-values can be read at the bottom of the summary info portion (lower right). There is a Play 4D triangular icon on the right toolbar to view the entire set, with Esc key used to stop the movie. The signal intensity (SI) and xyz coordinates of the mouse cursor s location are indicated at the bottom of the window. These values change as the mouse cursor moves on a volume. Scroll through the 4D dataset and observe artifacts on images with b-value = 400. Step 5: Draw 3D ROI Regions of interest (ROIs) are often constructed to designate an organ or a lesion. ROIs can be drawn on one or more slices in the volume. (Drawing lesions on multiple slices can give a more reliable estimate of lesion signal.) To create a ROI, we first bring up the Layer Control dialog box by left doubleclicking anywhere on the volume. We then click on New ROI 3D in Layer Control. The opacity of the ROI layer defaults to 20%. It can be changed using the horizontal slider at the bottom of the Layer Control box. The color of ROIs in a layer is assigned in an arbitrary fashion, but can be changed using the ViewFilter icon from the toolbar. The ROI layer has to be active before changing its opacity or color. This is achieved by clicking at the desired line. The active layer is the one shown in the red font. A 3D ROI layer is created by clicking on New ROI 3D 3

Painting an ROI is done by holding down the Ctrl key and the left mouse button. Holding down Ctrl key and the right mouse button will erase the ROI. Painting and erasing affects the active layer. The size of the paintbrush can be adjusted by simultaneously holding down the Ctrl key, clicking the left mouse button, and pressing and turning the mouse scroll wheel; The size of the eraser is adjusted similarly, by simultaneously holding down the Ctrl key, clicking the right mouse button, and pressing and turning the mouse scroll wheel. Paintbrush/Eraser can also be adjusted using Paintbrush icon from the toolbar. Try to draw a ROI for a lesion on the left kidney ROI for a lesion on the left kidney, drawn on b=50 volume as shown in the figure. The lesion is well visualized on the first volume (b-value=0) by widening the gray level filter. Bring up the Layer control, make the first layer active (red font), click on View Filter, type Center=80, Width=160, OK, then change the active layer back to second layer. The ROI is centered at around x=247, y=196, and z(slice#)=3 and 4. Step 6: Save, remove and load ROI An active ROI layer can be saved by clicking Save RAW. We will save our ROI in a file named lesion_sample.im using a simple format we call RAW Midas. Any active layer can be removed by clicking on Remove in the toolbar in Layer Control. Before removing a ROI, make sure it is the active layer (in red), then click Remove. A dialog box appears with the message Press YES to remove Active layer, hit Yes. To view a 3D document that was saved previously, click on Load RAW from the Layer Control. Step 7: Dynamic Activity Curves for voxels and ROI Click on the icon with a red curve on FV right side toolbar to bring up the Dynamic Activity Curve dialog box. Moving the mouse cursor on a volume FV will plot the signal intensity (SI) for b-values at the voxel. The 8 plotting points in the figure below indicate the 8 b-values of the original volume. We expect these values to decrease approximately exponentially. 4

Step 8 This step involves calculation of the ADC map (see Introduction). First, return to film view, and left click the blue kidney icon (second to the lowest) of the toolbar on the right. A dialog box labeled Parametric Map Calculation for Dynamic Experiment will appear. This box is also activated through 4D Processing -> Calculate Parametric Map. Switch Model to ADC monoexponential fit S = S0*exp(-b*ADC). Check ADC for Output and verify that ADC Upper Limit is 0.05. Press Process ROI only button at the bottom of the dialog box. The computer will calculate the ADC map within your ROI. When a ROI layer is present, FireVoxel offers three modes for model-fitting. Process ROI Only option will process only the voxels that belong to the ROI. The resulting parametric map will be computed very quickly, but regions outside the ROI will be set to void (transparent) value. The second mode, Process ROI As a Single TAC is even faster. All voxels within the given ROI are averaged before processing. The resulting parameter(s) are simply displayed as numbers and no new image layer(s) are constructed. The Process All option performs the computation on all voxels and outputs the result(s) as new layers. Even if ROIs are present, they will be ignored Step 9 The ADC map appears in a new, third layer. The purpose of layers is to view and manipulate multiple volumes in unison. All layers have identical resolution so that they could be superimposed in the same document. The transparency of the layer is controlled with the horizontal slider at the bottom of the Layer Control box. Press the Info button to display information about the volume. Press the ViewFilter button to change the way voxel intensities are mapped to screen colors: gray level window and color maps. Now switch ADC to make it the active layer, make sure ADC is in red. Step 10 The values of parametric maps (or PMV) will typically be in a decimal format. In contrast, Signal intensity (SI) is used to describe the values of acquired MRI data, which are almost always whole numbers. The ADC of the kidney lesion is about 0.003 mm 2 /s. However, it is not customary to work with decimal numbers in imaging most imaging software will expect voxel values to be whole numbers. In order to convert the ADC map into whole numbers, we will multiply it by 100000 and drop all digits after the decimal point. Before proceeding, delete lesion ROI layer. Then click on Volume from the upper left corner of the menu, and hit Linear Amplification over ROI. If ROI layers are not present, the entire volume is amplified. A dialog box appears; change coefficient from 1 to 100000, then hit OK. We have changed ADC units to 10^6 mm 2 /s. Notice that the voxel values (PMV= in the lower margin) in the kidney lesion change from about 0.003 to about 300.00. Linear amplification tool doesn't create a new layer, it modifies the active layer. 5

Step 11 From the menu bar select Volume and click on Real to Integer Volume conversion. In Specify Integer box we could leave the Resulting Bits as 10 (default), and hit OK. A new layer pops up, in which the decimals digits are rounded off to integers and clipped to the maximum 10 bit value of 1023 (=2 10-1). Verify that a kidney lesion ADC reads about 300. In the Layer Control dialog box, save the integer ADC map using Save Raw function of the toolbar on the right. Delete all layers except integer ADC map. Step 12 In Layer Control, reload the lesion map that you saved in Step 6 by clicking on Load Raw in the toolbar. Press ROI Stats 3D button to view ROI statistics. Statistics for the ADC image of kidney lesion voxels show the distribution to be a bit asymmetric, with mean of about 350 and standard deviation about 150. You may click Save Stats to save the histogram information for further processing. 6