H y d r o C A D. Owner's Manual

Similar documents
Flood Routing for Continuous Simulation Models

Linear Routing: Floodrouting. HEC-RAS Introduction. Brays Bayou. Uniform Open Channel Flow. v = 1 n R2/3. S S.I. units

Multi-Stage Outlet Structures

WMS 10.0 Tutorial Storm Drain Modeling SWMM Modeling Learn how to link a hydrologic model to the SWMM storm drain model

v. 9.1 WMS 9.1 Tutorial Watershed Modeling HEC-1 Interface Learn how to setup a basic HEC-1 model using WMS

WMS 9.1 Tutorial Storm Drain Modeling SWMM Modeling Learn how to link a hydrologic model to the SWMM storm drain model

Watershed Modeling Rational Method Interface. Learn how to model urban areas using WMS' rational method interface

Watershed Modeling HEC-HMS Interface

Introduction to Bentley PondPack

How to correct and complete discharge data Main text

Modeling CULTEC Chambers in HydroCAD - Using the Chamber Wizard

Modeling Detention Ponds Malaysian Example (v2009)

Cross Sections, Profiles, and Rating Curves. Viewing Results From The River System Schematic. Viewing Data Contained in an HEC-DSS File

Learn how to link a hydrologic model to the SWMM storm drain model

Storm Drain Modeling HY-12 Pump Station

Hydraulics and Floodplain Modeling Modeling with the Hydraulic Toolbox

Prof. B.S. Thandaveswara. The computation of a flood wave resulting from a dam break basically involves two

Storm Drain Modeling HY-12 Rational Design

Travel Time and Time of Concentration

Objectives Divide a single watershed into multiple sub-basins, and define routing between sub-basins.

Introducion to Hydrologic Engineering Centers River Analysis System (HEC- RAS) Neena Isaac Scientist D CWPRS, Pune -24

WMS 10.0 Tutorial Hydraulics and Floodplain Modeling HY-8 Modeling Wizard Learn how to model a culvert using HY-8 and WMS

HEC-RAS. A Tutorial (Model Development of a Small Flume)

Numerical Hydraulics

WMS 10.0 Tutorial Watershed Modeling MODRAT Interface Schematic Build a MODRAT model by defining a hydrologic schematic

CEE3430 Engineering Hydrology

Appendix H Drainage Ditch Design - Lab TABLE OF CONTENTS APPENDIX H... 2

ENV3104 Hydraulics II 2017 Assignment 1. Gradually Varied Flow Profiles and Numerical Solution of the Kinematic Equations:

b ma. The reservoir reduces The storage-outflow function is calculated in the following example, for Q = 57 ma/s, 2s/At b 20,890 ms/s as shown

This loads a preset standard set of data appropriate for Malaysian modeling projects.

Evaluating Multiple Stormwater Analysis and Design Alternatives with StormCAD

Culvert Studio User's Guide

Channel Routing & Lakes/Reservoirs in WRF-Hydro

CHAPTER 7 FLOOD HYDRAULICS & HYDROLOGIC VIVEK VERMA

Rapid Floodplain Delineation. Presented by: Leo R. Kreymborg 1, P.E. David T. Williams 2, Ph.D., P.E. Iwan H. Thomas 3, E.I.T.

WMS 8.4 Tutorial Watershed Modeling MODRAT Interface Schematic Build a MODRAT model by defining a hydrologic schematic

Peak Stormwater Engineering, LLC MEMORANDUM

Section 4: Pond Storage

HEC-RAS 3.0 January, 2001 Release Notes

Hydrologic Modeling using HEC-HMS

Bentley OpenRoads Workshop 2017 FLUG Fall Training Event

TUFLOW Urban Flood Models. Introduction. TUFLOW UK 2011 User Group Workshops. Phillip Ryan, Modelling Pipe Networks

MEMORANDUM. Corona Subdivision XP Storm Evaluation. Date: March 5, Curt Bates, City of Petaluma. David S. Smith, P.E., WEST Consultants, Inc.

WMS 9.1 Tutorial GSSHA Modeling Basics Stream Flow Integrate stream flow with your GSSHA overland flow model

Hydrologic Modeling System HEC-HMS

Connecting 1D and 2D Domains

Build a MODRAT model by defining a hydrologic schematic

Efficiency and Accuracy of Importing HEC RAS Datafiles into PCSWMM and SWMM5

Module 9. Lecture 3: Major hydrologic models-hspf, HEC and MIKE

Documentation for Velocity Method Segment Generator Glenn E. Moglen February 2005 (Revised March 2005)

Application Description

Chapter 16. Table of Contents

Questions and Answers

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 3, 2012

Steady Flow Water Surface Profile Computation Using HEC-RAS

Required: 486DX-33, 8MB RAM, HDD w. 20 MB free, VGA, Win95. Recommended: Pentium 60, 16 MB RAM, SVGA, Win95 or NT

Automating Hydraulic Analysis v 1.0.

Gavin Fields Senior Water Resources Engineer XP Solutions

Day 1. HEC-RAS 1-D Training. Rob Keller and Mark Forest. Break (9:45 am to 10:00 am) Lunch (12:00 pm to 1:00 pm)

2D Model Implementation for Complex Floodplain Studies. Sam Crampton, P.E., CFM Dewberry

Watershed Analysis Lab Heterogeneous, Gaged Watershed I (Northwest Branch)

HEC-ResSim. Reservoir System Simulation. User s Manual. Version 2.0 September US Army Corps of Engineers Hydrologic Engineering Center CPD-82

OA: Operations and Algebraic Thinking

Appendix E-1. Hydrology Analysis

FLOODPLAIN MODELING MANUAL. HEC-RAS Procedures for HEC-2 Modelers

PCSWMM 2002 RUNOFF Block PAT AVENUE Storm Drainage Design

THE NWS SIMPLIFIED DAM-BREAK FLOOD FORECASTING MODEL

DAILY FLOW ROUTING WITH THE MUSKINGUM-CUNGE METHOD IN THE PECOS RIVER RIVERWARE MODEL

Mathematics LV 3 (with QuickTables)

Improving the Senior Level Hydraulic Engineering Design Course (CE 474) By Means of Computer Assisted Instruction

Faculty of Engineering. Irrigation & Hydraulics Department Excel Tutorial (1)

The HEC-RAS Model Refresher

River Analysis System HEC-RAS

Use of measured and interpolated crosssections

HCFCD Review Process

TUFLOW 1D/2D SURFACE WATER MODELING SYSTEM. 1 Introduction. 2 Background Data

Prepared for CIVE 401 Hydraulic Engineering By Kennard Lai, Patrick Ndolo Goy & Dr. Pierre Julien Fall 2015

NONUNIFORM FLOW AND PROFILES. Nonuniform flow varies in depth along the channel reach. Figure 1 Nonuniform Flow

HEC-22 Inlets in INFOSWMM and H2OMAP SWMM v12

25 Using Numerical Methods, GIS & Remote Sensing 1

Grade 9 Math Terminology

Ducks on the Pond: Stormwater Management Basin Analysis Using AutoCAD Civil 3D and Autodesk SSA

WMS 9.1 Tutorial Hydraulics and Floodplain Modeling Floodplain Delineation Learn how to us the WMS floodplain delineation tools

Comparison of 1D and 2D Surface Water Models for Solid Waste Facilities. Garth R. Bowers, P.E., Carl E. Bueter, P.E., Larry Henk

4 th Grade Math - Year at a Glance

UNDERSTAND HOW TO SET UP AND RUN A HYDRAULIC MODEL IN HEC-RAS CREATE A FLOOD INUNDATION MAP IN ARCGIS.

Mathematics LV 5 (with QuickTables)

California Standard Study Island Topic Common Core Standard

HY-8 Quick Start Guide. What s in this Quick Start Document. Technical Methods. HY-8 Quick Start

George Mason University Department of Civil, Environmental and Infrastructure Engineering. Dr. Celso Ferreira Prepared by Lora Baumgartner

RtI 7. Curriculum (219 topics additional topics)

Automatic Discretization and Parameterization of Watersheds using a Digital Elevation Model

v Prerequisite Tutorials GSSHA Modeling Basics Stream Flow GSSHA WMS Basics Creating Feature Objects and Mapping their Attributes to the 2D Grid

Advanced 1D/2D Modeling Using HEC-RAS

v TUFLOW-2D Hydrodynamics SMS Tutorials Time minutes Prerequisites Overview Tutorial

Comparing HEC-RAS v5.0 2-D Results with Verification Datasets

Mathematics LV 4 (with QuickTables)

HECRAS 2D: Are you ready for the revolution in the world of hydraulic modeling?

v TUFLOW 1D/2D SMS 11.2 Tutorial Time minutes Prerequisites TUFLOW 2D Tutorial

Introduction to Compound Channel Flow Analysis for Floodplains

Transcription:

H y d r o C A D Stormwater Modeling System Version 8 Owner's Manual Copyright 2006 HydroCAD Software Solutions LLC. All rights reserved. HydroCAD is a registered trademark of HydroCAD Software Solutions LLC. Other trademarks are the property of their respective owners. HydroCAD Software Solutions LLC P.O. Box 477 Chocorua, NH 03817 1-800-927-7246 Tel: (603) 323-8666 Fax: (603) 323-7467 www.hydrocad.net ISBN 978-0-913633-12-0 6182 rev. 3/27/06 1

Section 18 - Reach Routing Calculations A reach is used to perform an independent hydrograph routing through an open channel, or through a pipe flowing under open-channel conditions. A channel or pipe can alternatively be modeled as a flow segment within a subcatchment, where its travel time will contribute to the Tc. The later approach is usually simpler, and may even be necessary in the case of a subcatchment that is draining along the entire length of the reach. However, for a long reach with a significant inflow at one end, a separate reach routing may be called for. This section details the procedures used to perform an independent reach routing. The Routing Curves Reach routing requires that the reach first be characterized by two curves: the end-area vs. depth (stage-storage), and the discharge vs. depth (stage-discharge). This information may be determined by one of the following procedures: 1) The user may directly specify the end-area and discharge at any number of depths. Values for intermediate depths are interpolated as described on page 70. 2) The user may enter the end-area and wetted perimeter at each depth. Values for intermediate depths are interpolated as described on page 70. Manning's equation is then used to calculate the discharge at each depth (see Basic Hydraulics p.77): V' 1.486R 2 n 1 3 2 So Eq. 19 V=Average velocity of flow [ft/sec] or [m/sec] 1.486=English factor (use 1.0 for metric) R=Hydraulic radius [ft] or [m] S 0 =Slope of hydraulic grade line [rise/run] =Slope of channel bottom, assuming normal flow n=manning's number (See table on page 144) also R ' A P and Q ' VA Eq. 20 A=Area of flow [ft²] or [m²] P=Wetted perimeter [ft] or [m] Q=Flow [ft³/sec] or [m³/sec] thus 1.486 A 2 1 3 S 2 A P Q' n 5 1 ' 1.486 A 3 2 S np 2 3 Eq. 21 3) For a rectangular, vee, trapezoidal, parabolic, or circular (pipe) channel, the user may provide the appropriate dimensions, and HydroCAD will determine the end-area and discharge curves using the cross section equations on page 154, and Manning's equation as shown above. HydroCAD Technical Reference 67

4) Other shapes, such as natural channels, can be described by entering a custom cross-section. The section is defined by a table of coordinates that indicate the offset and elevation of points along the cross-section. Manning s equation is then used to calculate the flow at any required depth. 5) A custom cross-section may also be defined in which each segment has a different Manning s value. The total flow is determined with a composite Manning s value or segmented flow, using one of the following methods. (See Open Channel Hydraulics p.136.) Horton (deep flow) method n c ' 3/2 j (ni P i ) j P i 2/3 Eq. 22 n c =Composite Manning s number n i =Manning s value for segment i P i =Wetted perimeter for segment i This technique is commonly used for deep channels, where the velocity is relatively constant throughout the cross-section. If applied to a section with a constant Manning s value, the result is identical to the original Manning s value. Pavlovskii (shallow flow) method n c ' j (n 2 i P i ) j P i 1/2 Eq. 23 n c =Composite Manning s number n i =Manning s value for segment i P i =Wetted perimeter for segment i This technique is commonly used for shallow channels, where the velocity may vary considerably between segments. It is based on the assumption that the total resistant force for the cross-section is the sum of the resistant force for each of the segments. Lotter (subdivided flow) method n c ' j PR 5/3 P i R 5/3 i n i Eq. 24 n c =Composite Manning s number n i =Manning s value for segment i P i =Wetted perimeter for segment i R i =Hydraulics radius for segment i = Area i /P i P=Total wetted perimeter = sum(p i ) R=Hydraulic radius for entire channel = Area/P 68 HydroCAD Technical Reference

This technique is based on the assumption that the total flow is equal to the sum of the flows for the individual segments. If applied to a section with a constant Manning s value, the result is not the same as the original Manning s value. Subdivision by Segment Q ' j Q i Eq. 25 Q=Total flow for cross-section [ft³/sec] or [m³/sec] Q i =Flow for segment i (see eq.21) [ft³/sec] or [m³/sec] This technique produces exactly the same flow as the Lotter method, described above. It differs only in the calculation procedure, in which the total flow is the sum of the flows calculated separately for each segment, without the use of a composite Manning s value. Subdivision by Manning's Value Q ' j Q n Eq. 26 Q=Total flow for cross-section [ft³/sec] or [m³/sec] Q n =Flow for consecutive segments with same Manning s value This technique subdivides the channel only when there is a change (break) in the Manning's value. This produces more consistent results than subdivision by segment, in that the resulting flow is independent of the number of points along the cross section. When all segments have the same Manning's value, the flow is identical to the traditional solution for a constant Manning's value. This technique is similar (although not identical) to the current procedure used in HEC-RAS. Other Procedures If another technique is used to calculate flow through a complex cross-section, the rating curve can be calculated separately and entered into HydroCAD using option 1, above. However, using a defined geometry or cross-section allows direct evaluation of the channel at any depth, without having to interpolate between a (smaller) number of user-defined stages. Reach Routing Limitations The preceding stage-discharge calculations are based solely on Manning's equation, and do not consider possible inlet, outlet, or tailwater effects. If a complete analysis is desired for a pipe, including entrance losses and possible tailwater effects, it should be modeled as a pond with a culvert outlet. If a detailed water surface profile is required for a channel, you should use a program specifically designed for that purpose. 23 23 Surface water profiles are usually calculated under constant-flow conditions, rather than with a hydrograph (timevarying flow). Peak flows (from HydroCAD or another hydrograph model) are often used as input for these calculations. HydroCAD Technical Reference 69

Reach Routing Table When performing a reach routing, HydroCAD uses an internal routing table to provide storage and discharge information at any required depth. The construction of this table depends on the selected reach type, as listed on page 67. When entering discharge or wetted-perimeter directly (reach types 1 or 2), several interpolation options are available: Linear: This option creates a routing table containing the same number of depth values (stages) specified by the user. When the routing is performed, intermediate storage and discharge values are obtained by linear interpolation between these stages. (This option is provided primarily for compatibility with HydroCAD 7.1 and earlier.) Multi-point: This option creates a routing table with a larger number of evenly-spaced depth intervals (normally 100). Each user-specified depth is also included in the table, to ensure accuracy at these exact depths. Storage is calculated at each tabulated depth using a linear interpolation between user-defined stages. When entering wetted-perimeter, linear interpolation is used to determine the perimeter at each tabulated depth, and the corresponding discharge is calculated with Manning's equation. When entering discharge, linear interpolation is used to determine the discharge at each tabulated depth. Multi-point is the default option, and is recommended for most situations. Parabolic: This option creates a routing table with a larger number of evenly-spaced depths, just like Multi-point, except that intermediate values are determined by parabolic interpolation using the three adjacent user-defined stages. This option may provide greater accuracy when the user-supplied rating table contains a limited number of stages. However, the resulting storage and discharge plots should be examined to be sure that a parabolic fit is appropriate for the data. Note: Due to ongoing software development, other interpolation options may be available in the latest software release. When using a standard channel geometry or cross-section (reach types 3 to 5, starting on page 67), the routing table normally contains 100 evenly-spaced depth values, ranging from zero depth up to the overall depth of the reach. At each tabulated depth, HydroCAD calculates the perimeter, storage, and discharge based on the channel geometry and Manning s equation. For all reach types, the finished routing table is used to perform the actual routing calculations, using a linear interpolation to determine the storage and discharge at intermediate depths. If greater accuracy is required, the number of depth increments can be increased on the Advanced tab of the applicable reach. Reach Routing Methods HydroCAD currently provides the following techniques for reach routing, as described in the remainder of this section.! Storage-Indication Method (Stor-Ind)! Storage-Indication plus Translation (Stor-Ind+Trans)! Dynamic Storage-Indication Method (Dyn-Stor-Ind)! Muskingum-Cunge Method! Dynamic Muskingum-Cunge Method! Simultaneous Routing (Sim-Route) 70 HydroCAD Technical Reference

Storage-Indication Method The Storage-Indication method (Stor-Ind) is the most basic reach routing technique provided by HydroCAD, and is based on the routing equations developed on page 103. The actual routing procedure is as follows. 1) The reach's stage-discharge relationship is calculated as described above. 2) The stage-storage relationship is determined from the reach cross-section multiplied by the length. 3) The stage-discharge and stage-storage curves are used to create a storage-indication curve. 4) Routing is performed using the specified time span and time increment. At each point in time, a storage-indication value is calculated based on the current inflow, plus the previous inflow, outflow, and volume in the reach. 5) The current storage-indication value and the storage-indication curve are used to determine the new elevation. 6) Using the new elevation, the stage-storage and stage-discharge curves are consulted to determine the new storage and discharge. 7) This process is repeated for all points in the inflow hydrograph. In practice, the procedure may incorporate a number of other factors, such as a base flow or inflow loss. Any unusual conditions, such as the channel overtopping, will produce a specific warning message as listed on page 115. Storage-Indication plus Translation The Stor-Ind+Trans method is identical to the Storage-Indication method described above, except that the storage-routed hydrograph is subject to a further time lag (translation) by the travel time, as defined on page 113. This is an early technique provided by HydroCAD to allow for travel time on some reaches. For longer reaches, or when peak timing is critical, a full kinematic routing procedure is recommend, such as the Muskingum-Cunge method, described below. Dynamic Storage-Indication Method The Dyn-Stor-Ind reach routing procedure is identical to the Storage-Indication method described above, except that the calculations are performed over the entire watershed at each time step. Although the reach routing results are unchanged, this allows the overall watershed to be analyzed in a dynamic manner so that ponds may respond to tailwater effects as described on page 105. HydroCAD Technical Reference 71

Muskingum-Cunge Method This routing method is intended to duplicate results that would be obtained with the current Win-TR-20 software. (See Muskingum-Cunge Flood Routing Procedure in NRCS Hydrologic Models by William H. Merkel.) The basic HydroCAD procedure is as follows: 24 Step 1: Determine m-value vs. Depth The m value defines the relationship between the flow velocity (V) and the wave velocity or celerity (c). m is the slope of the discharge-area curve in a log-log plot, and is constant at all depths for basic channel geometries, such as vee and trapezoidal. However, for complex cross sections, and especially for flood plains, the value can vary considerably with depth. To handle these situations, HydroCAD uses a weighted m value, according to the same procedure developed for TR-20. When stage data is entered directly, the m value is calculated at each user-specified depth, and then interpolated to the depths used in the internal routing table. When using a standard channel geometry or cross-section, m is directly calculated at each depth in the routing table. Step 2: Select Reference Flow HydroCAD currently provides a constant-parameter implementation of the Muskingum-Cunge procedure. This requires the selection of a constant reference flow at which the routing parameters will be determined. When using a sequential routing procedure, the reference flow is set equal to the peak inflow. When using a dynamic routing procedure, the peak is unknown until the completion of the routing, so the reference flow is set equal to the channel-full capacity. In either case, the user may override the default value by entering the preferred reference flow on the reach edit screen. Step 3: Determine Wave Velocity Using the reference flow, the equivalent flow depth, velocity, and m value are determined by linear interpolation from the routing table. (The user may override the automatic m value by entering the preferred value on the reach edit screen.) The wave velocity (celerity) is then given by: c ' mv Eq. 27 c=wave velocity (celerity) [ft/sec] or [m/sec] m=rating curve exponent V=Flow velocity [ft/sec] or [m/sec] Step 4: Determine Time and Distance Steps The time step ( t) is generally selected in order to provide sufficient definition for the runoff and inflow hydrographs. This selection will generally ensure that the inflow peak occurs after at least ten time steps, as recommended in the TR-20 implementation. If necessary, a smaller time step can be specified. The overall reach length may require division into a number of equal sub-reaches of length x, such that x is approximately equal to the distance traveled by the flood wave in a single time step: 24 Due to ongoing software development, the details of this implementation are subject to change over time. For the latest updates, as well as additional details, please visit the Support Page at www.hydrocad.net 72 HydroCAD Technical Reference

to obtain x.c t where x' L N ˆ N'round L c t Eq. 28 x=distance step (length of sub-reach) [ft] or [m] t=time step (dt) [sec] c=wave velocity (celerity) [ft/sec] or [m/sec] L=Total reach length [ft] or [m] N=Number of sub-reaches Note that N is rounded to the nearest whole number, but never less than 1. Step 5: Determine Routing Parameters The following equation defines the Muskingum relationship between reach inflow, outflow, and storage: S ' K XI% (1&X)O Eq. 29 S=Reach storage [ft³] or [m³] K=Storage constant [sec] X=Weighting factor [dimensionless] I=Reach inflow [ft³/sec] or [m³/sec] O=Reach outflow [ft³/sec] or [m³/sec] The routing parameters K and X are given by: K ' x c Eq. 30 K=Wave travel time through sub-reach [sec] x=distance step (length of sub-reach) [ft] or [m] c=wave velocity (celerity) [ft/sec] or [m/sec] X ' 1 2 1& Q BS o c x ' 1 2 1& VD S o c x Eq. 31 X=Routing factor (0.0 to 0.5) Q=Reference flow [ft³/sec] or [m³/sec] B=Average flow width of reference flow [ft] or [m] V=Reference flow velocity [ft/sec] or [m/sec] D=Reference flow depth [ft] or [m] S 0 =Slope of hydraulic grade line [rise/run] =Slope of channel bottom, assuming normal flow Note that the selection of x will produce a wave travel time K that approximates the time step t. The routing factor X controls the peak outflow, with smaller values producing more attenuation. HydroCAD Technical Reference 73

Step 6: Calculate Routing Coefficients Conservation of mass is assured by use of the continuity equation: S 2 & S 1 ' I 1 %I 2 2 & O 1 %O 2 2 t Eq. 32 S 1,S 2 =Storage at time t 1 and t 2 [ft³] or [m³] I 1,I 2 =Inflow at time t 1 and t 2 [ft³/sec] or [m³/sec] O 1,O 2 =Outflow at time t 1 and t 2 [ft³/sec] or [m³/sec] t=time difference between t 1 and t 2 [sec] Combining with eq.29 and simplifying yields the final routing equation: O 2 ' C 1 I 1 % C 2 I 2 % C 3 O 1 where C 1 ' t/k%2x C 0 C 3 ' 2(1&X)& t/k C 0 C 2 ' t/k&2x C 0 C 0 ' t K %2(1&X) Eq. 33 Step 7: Perform Hydrograph Routing The routing equation (eq. 33) is applied at each time step t in the inflow hydrograph. If the reach has been divided into sub-reaches (N>1), the calculation is repeated for each sub-reach, using the outflow of the previous sub-reach as the inflow to its successor. The continuity equation (eq. 32) is also evaluated at each time step in order to determine the reach storage, average depth, and average flow velocity over the length of the reach. As an aid to evaluating the routing results, a detailed list of routing parameters is included in the reach summary report. (Click any part of the report for a detailed discussion of each parameter.) Dynamic Muskingum-Cunge Method The Dynamic Muskingum-Cunge procedure is identical to the standard Muskingum-Cunge procedure described above, except that the calculations are performed over the entire watershed at each time step. Although the reach routing results are unchanged, this allows the overall watershed to be analyzed in a dynamic manner so that ponds may respond to tailwater effects as described on page 105. The Dynamic Muskingum-Cunge procedure will produce the same reach routing results as the standard (sequential) Muskingum-Cunge procedure, as long as the same reference flow is used. 74 HydroCAD Technical Reference

Simultaneous Reach Routing The Sim-Route reach routing procedure is provided for compatibility with simultaneous pond routing. Although this method does not currently allow reaches to respond to tailwater changes, its does allow the overall watershed to be analyzed in a simultaneous manner so that ponds may respond to tailwater effects as described on page 107. Simultaneous reach routing is based on the basic equation for conservation of mass. (See Hydrologic Analysis and Design p.545.) I & O ' S t where S ' S 2 &S 1 ˆ S 2 ' S 1 %(I&O) t Eq. 34 I=Inflow rate [ft³/sec] or [m³/sec] O=Outflow rate [ft³/sec] or [m³/sec] t=time increment (dt) [sec] S=Change in storage [ft³] or [m³] S 1 =Storage at start of time interval [ft³] or [m³] S 2 =Storage at end of time interval [ft³] or [m³] The following procedure is used to perform the actual hydrograph routing: 1) Routing is performed using the specified time span and time increment, and begins with no water stored in the reach. 2) The new reach storage (S 2 ) is calculated using the above equation with the previous rates of inflow and outflow. (Using the previous value allows non-sequential flows, for which the current inflow is unknown.) 3) Using the new storage volume, a new flow depth is calculated based on the assumption of normal flow. 4) Using the new flow depth, a new discharge is calculated from Manning's equation or from the user-defined stage-discharge relationship. 5) Steps 2 through 4 are repeated at each time interval until the entire hydrograph has been developed. Additional considerations apply to all simultaneous routing procedures as described on page 107. HydroCAD Technical Reference 75

Effects of Reach Routing A reach will normally attenuate and delay the hydrograph that is routed through it. The extent of this transformation depends on many factors, including the reach dimensions, slope, and Manning's number. Short reaches (up to several hundred feet) often have a minimal effect on the routed hydrograph. For this reason they are frequently modeled as a flow segment within a subcatchment. On the other hand, for long reaches with large cross-sections, low slopes and/or high Manning's numbers, the routing effect can be significant. The graph at right shows the effects of storageindication routing through a 5500 foot long channel. Significant attenuation may also occur on shorter reaches if the inflow peak is of short duration. Allowing for Travel Time The storage-indication method, as illustrated above, accounts for only the storage effects of the reach. Other techniques must be used to account for the kinematic effects of long reaches, such as the Stor-Ind+Trans method described on page 71. A close examination of the graph below reveals that the peak discharge no longer corresponds to a point on the inflow curve, but is translated according to the travel time. A better option for modeling kinematic effects is the Muskingum-Cunge method described on page 72. This is the standard reach routing procedure in the latest Win-TR-20 release, and is recommended when significant kinematic effects are present. 76 HydroCAD Technical Reference