MPU-32 DEVICENET INTERFACE

Similar documents
POWR-GARD Motor Protection PGR-6200 SERIES Motor Protection System PGR-6200 DEVICENET INTERFACE

MPU-32 ETHERNET/IP INTERFACE

MPS DEVICENET INTERFACE

FPS DEVICENET INTERFACE

SE-330/SE-330AU/SE-330HV DEVICENET INTERFACE

EL731 DEVICENET INTERFACE

SE-330 SERIES (NEW REVISION) DEVICENET INTERFACE

EL731 PROFIBUS INTERFACE

SE-330 SERIES (NEW REVISION) ETHERNET/IP INTERFACE

Section 1.0 Description Section 2.0. Section 3.0. Section 4.0. MCD3000 DeviceNet Gateway. Contents

MPU-32 AND FPU-32 TIA-485 NETWORK

Series SD6 Limit with DeviceNet

MCD 200 Series. MCD 200 DEVICENET Module OPERATING INSTRUCTIONS. MCD 200 DEVICENET Module. Order Code: 175G9002. Adjustment.

Series SD6 with DeviceNet (Addendum)

CDN572-5 DEVICENET SPECIFICATIONS

CDN067 DEVICENET SPECIFICATIONS

SOFTWARE FUNCTIONAL REQUIREMENTS SPECIFICATION. Athena DeviceNet Interface Module Revision /26/2001

CDN127 DeviceNet SPECIFICATIONS

X-gateway Interface Addendum DeviceNet Scanner Interface

1782-JDC DeviceNet/Serial Gateway User s Manual

Built-in Board Option DEV001Z. Function Manual

DN120 DeviceNet Gateway User Manual

1. Installation DEVICENET INTERFACE. Install the DeviceNet Interface using the following procedure:

DeviceNet (CME-DN01) User Manual

DN-01 Instruction Manual

Connections and Data Exchange

DNP31.0 DeviceNet Interface

MicroNode I/O TM DeviceNet AI User Manual

PGR-3200 MANUAL INSULATION MONITOR

Intelligent Technologies

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

SE-330 SERIES (NEW REVISION) MODBUS/TCP INTERFACE

Communication Network. DeviceNet Communication

Install the DeviceNet Module using the following procedure:

FPU-16 A-B PROTOCOL/DATA LOGGER MANUAL

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

DeviceNet INSTRUCTION MANUAL. Series 956. Resolver Displacement Transducer

AVTRON DeviceNet OPTION BOARD (For Use with ACCel500 Frequency Converters)

TOSVERT VF-AS1/PS1. Option Function Manual DEV002Z-2

DeviceNet TM Supplemental Manual for Brooks Instrument Delta Class MFC s/mfm s

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Start-up Guide DeviceNet Adapter Module CFB-DEV

C441 Ethernet Module User Manual (C441R, C441T, C441U, C441V)

BNI DNT Z001 DeviceNet IO-Link Master User s Guide

X-gateway Interface Addendum DeviceNet Scanner

DEFAULT IP ADDRESS

1782-JDO DeviceNet-to-Optomux Gateway User s Manual

CATALOG NUMBER 193-EDN

How to Control and Monitor a C441 Motor Insight via DeviceNet

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

user's manual DeviceNet nx frequency converters option board

MicroNode I/O TM DeviceNet COMBO User Manual

CDN36X Series DeviceNet Gateway User Manual

Ethernet/IP Module. User Manual. Contents

- 15G0078B120 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

3GV M Modbus RTU Register Map

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

Anybus-IC DeviceNet. Fieldbus Appendix. Doc. Id. HMSI Rev Connecting Devices TM

Instructions. Modbus RTU Card (WSIQ-COM-MB)

ABOUT THIS GUIDE. Chapter 1. Implementing 6K DeviceNet Chapter 2. Implementing Gemini DeviceNet... 21

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

Communication Protocol DeviceNet Interface for Bayard-Alpert / Pirani Gauge and High Pressure / Pirani Gauge BPG400-SD HPG400-SD tira03e1-b (0310) 1

GE Power Management. MMII Intelligent MCC Controller

DeviceNet for Capacitance Diaphragm Gauge

MICRO-SCREEN DIN Controllers with DeviceNet Trip Output

Powered Roller Controller for DeviceNet

DeviceNet Interface for Bayard-Alpert Pirani Gauge

Supplemental Manual for Brooks DeviceNet MFC/RTs

Profinet Module. User Manual. Contents

Network Interface Appendix Anybus -CompactCom DeviceNet

Overview This section describes how to use the LTM R controller via the network port using the Modbus protocol.

LM10 to MM200 Retrofit

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Optidrive VTC Modbus RTU Register Map

D485 Modbus to DeviceNet Converter Instruction Manual

Betriebsanleitung Operating Instructions

M3-61B DeviceNet Slave Module. M3-61B DeviceNet Slave Module CONTROL TECHNOLOGY CORPORATION

Power Xpert C445 Motor Management Relay Cheat Sheets

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

E1 Plus Electronic Overload Relay

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

1782-JDC DeviceNet Serial Gateway User s Manual

SE-MON330 SOFTWARE MANUAL

DeviceNet - ODVA Conformance Test Results

DeviceNet SDNL-0404D-xxxx. IO Data Mapping DeviceNet Objects Indicators and Switches

MM200 Motor Management System Communications Guide

Copyright: December 2017 Nidec Issue: E

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

Allen-Bradley. User Manual. Stack Light 855T

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Communication Modules. DeviceNet. Operating Instructions 07/2010 SITRANS F

Varispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1

Intelligent Technologies QCPort Cover Control

BLEMO Frequenzumrichter. Siemensstraße Rodgau Dudenhofen

L5351 DeviceNet Communications Interface

MITSUBISHI TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- Option. DeviceNet TM FR-E5ND MITSUBISHI ELECTRIC

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

Modbus Map: Automatic Generator Start (AGS) Device

Maximize process uptime with the SEL-patented motor thermal model.

Transcription:

3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/relayscontrols INTERFACE Revision 8-A-050914 QUICK SETUP Use the operator interface to access the Setup Hardware Network Comms menu. Set the Network ID for the device and set the Baud Rate as DN 125K, DN 250K, or DN 500K. Select the DeviceNet producing assembly from the DeviceNet Produce menu and the DeviceNet consuming assembly from the DeviceNet Consume menu. Select DeviceNet from the Network Type menu. Configure the scanner s polled connections for the selected assembly sizes. The scanner may issue a configuration warning if an I/O size other than the default is used. Disregard the warning. Use Edit I/O Parameters to enable the connection and adjust the byte size to match the assembly size. Copyright 2014 Littelfuse Startco All rights reserved. Document Number: PM-1119-EN Printed in Canada.

DeviceNet Interface Page i This page intentionally left blank.

DeviceNet Interface Page ii SECTION TABLE OF CONTENTS PAGE 1 General... 1 2 DeviceNet Interface... 1 2.1 Connections and Power Requirements... 1 2.2 Network Settings... 1 2.3 Manual Changes... 1 2.4 Network Status Display... 1 2.5 Network Errors... 1 2.6 Configuration Using RSNetWorx... 1 2.7 LED Indication... 2 2.8 Conformance Tests... 2 3 DeviceNet Objects... 2 3.1 Identity Object... 2 3.2 Message Router... 3 3.3 DeviceNet Object... 3 3.4 DeviceNet Connection Object... 5 3.5 Assembly Object... 7 3.6 Control Supervisor Object... 10 3.7 Overload... 14 3.8 Set Point Class 0x64... 17 3.9 RTD Module Class 0x65... 20 3.10 RTC Class 0x66... 26 3.11 User-Defined Register Class 0x67... 26 3.12 Data Logging Class 0x68... 28 Appendix A DeviceNet EDS Files... 30 Appendix B DeviceNet Interface Revision History... 31 DISCLAIMER Specifications are subject to change without notice. Littelfuse Startco is not liable for contingent or consequential damages, or for expenses sustained as a result of incorrect application, incorrect adjustment, or a malfunction. TABLE LIST OF TABLES PAGE 1 DeviceNet Status Display... 1 2 EDS File Revisions... 1 3 DeviceNet Objects... 2 4 Explicit Messaging... 8

DeviceNet Interface Page iii This page intentionally left blank.

DeviceNet Interface Page 1 1. GENERAL This document describes the DeviceNet features supported by the. The supports Explicit and Polled I/O. It does not support the Unconnected Message Manager (UCMM). The is an isolated node and requires both control power for its operation and DeviceNet power for network operation. 2. INTERFACE 2.1 CONNECTIONS AND POWER REQUIREMENTS Connection to the is made through the 5-pin, open style, terminal block, plug-in connector as defined by the DeviceNet standard: Terminal 1: V- Terminal 2: CAN-L Terminal 3: DRAIN Terminal 4: CAN-H Terminal 5: V+ The interface requires 30 ma from the 24 Vdc DeviceNet supply. 2.2 NETWORK SETTINGS The DeviceNet MAC ID and baud rate is set using the menu setting. Default settings are MAC ID equal to 63 and baud rate of 125 kb. Settings are located in the Setup Hardware Network Comms menu. MAC ID and baud rate can also be set using the DeviceNet object. NOTE: Changing network settings using the menus or SE-Comm-RIS will restart the DeviceNet driver. 2.3 MANUAL CHANGES Appendix E, Register 379/380: Network ID range is 0 to 63. Values greater than 63 will be forced to 63. 2.4 NETWORK STATUS DISPLAY The DeviceNet communication status can be viewed using the Metering Network Status menu. This menu indicates ACTIVITY or NO CNXNS. The last communication status is also displayed. The can be programmed to trip if there is no network activity. TABLE 1. STATUS DISPLAY DISPLAY Rx OVR Receive Q Overrun (1) Tx OVR Transmit Q Overrun (1) CAN OVR CAN Overrun (1) Dup MAC Duplicate MAC (2) Bus Sense DeviceNet Power Off (3) MAC Set MAC Was Set (1) ID Rst 0 ID Reset 0 (1) ID Rst 1 ID Reset 1 (4) Bus Off Error on the Bus (2) Expl T/O Explicit Timeout IO T/O I/O Timeout (5) IO Delete I/O Connection Deleted Drv Error Driver Error (1) (1) (2) (3) (4) (5) Driver is restarted. Faulted state with NS RED LED ON. Driver will attempt a restart after 120 seconds. NS LED off. Driver halted until DeviceNet power is applied. is restarted with address 63 and baud rate of 125 kb. NS flashes RED until a new connection is established. 2.6 CONFIGURATION USING RSNETWORX Use the EDS Wizard to register the eds file. The device will register as a Motor Starter named Startco. Select device properties to view Device Parameters. When there is a request to upload from device, select this option. This will load the present configuration from the. Parameters accessible using RSNetWorx have a DeviceNet parameter number listed in the DeviceNet Objects sections of this manual. The corresponding register number is also shown where applicable. firmware revisions may also require a revision change to the eds file. RSNetWorx will indicate an error if the Major Rev number of the eds file does not match the value read from the. Select the eds file that matches the revision number. TABLE 2. EDS FILE REVISIONS FILE REV MAJOR REV REV 1.2 01 (1.1) < 1.50 1.4 02 (2.001) 1.50 to 1.59 1.5, 1.6 03 (3.001) 1.60 to 1.69 1.7 04 (4.001) 1.70 2.5 NETWORK ERRORS The can be configured to trip or alarm on a loss of connection by using the Setup Hardware Network Comms menu, or by using attribute 0x64 of the DeviceNet object. The Net Trip/Alarm set point selects the action to be taken when the module has no connections. The latest communication status is displayed in the Metering Network Status menu. Communication status displays are listed in Table 1.

DeviceNet Interface Page 2 2.7 LED INDICATION Two LED s on the rear panel of the indicate Network Status (NS) and Module Status (MS). The MS LED is ON when the DeviceNet driver is enabled in the, and OFF when the driver is disabled. The NS LED is OFF when DeviceNet power is off and also OFF during the Duplicate MAC check, when there are no other nodes on the network. The NS LED flashes green after the Duplicate MAC check is complete and is steady green when a connection is established. The NS LED flashes red when an I/O connection has timed out and is steady red if a Duplicate MAC or Bus Off condition exists. NOTE: On loss of an I/O connection, the NS LED remains flashing red until a new connection is established. 2.8 CONFORMANCE TESTS Conformance tested to Version A-19 Hardware passes the Physical Layer Test Version B4 The EDS file passes EDS file Test Version 2.17 3. OBJECTS (In Order of Class Number) The module supports the following objects: TABLE 3. OBJECTS CLASS 0x01 Identity (1) 0x02 Message Router (1) 0x03 DeviceNet (1) 0x04 Assembly (1) 0x05 Connection (1) 0x29 Control Supervisor (1) 0x2C Overload (1) 0x64 Set Point 0x65 RTD Module 0x66 RTC 0x67 User Defined Registers 0x68 Data Logging (1) Conformance tested using DeviceNet Protocol Conformance Test Software Version A-17. 3.1 IDENTITY OBJECT Identity Object Class Services _Attribute_Single: Returns contents of specified Identity Class 1, Instance 0 Attributes 1 Revision Revision of this object. 1 UINT 2 Max Instance Maximum number of instances. 1 UINT

DeviceNet Interface Page 3 Identity Object Instance Services _Attribute_Single: Returns contents of specified Set_Attribute_Single: Modify the specified Reset: Performs reset services based on the parameter. Reset is to Class 1, Instance 1. No Parameter or Parameter = 0: The DeviceNet driver is reset with the existing MACID and baud rate. Parameter = 1: The MACID is set to 63 and the baud rate is set to 125 kb. The will then perform a reset that emulates cycling control power. Identity Class 1, Instance 1 Attributes 691 UINT 1 Vendor ID Identification of each vendor by number. 2 Device Type Motor Starter 22 UINT 3 Product Code Platform 301 UINT 0 4 Revision Major revision must match the A2 02 eds value (Major.Minor). C6 C6 5 Status Summary Status of the Device 0, 0, 255 WORD 6 1 Serial Serial number of. N/A, 0, UDINT 2/3 Number 999999999 7 Product Name Human Readable Identification Startco SHORT_ Identity Class 1, Instance 1 Attributes (Continued) N/A, 100, N/A 100 (0x64) 2 Revision Revision of Firmware: 100 = 1.00 UINT 1 101 (0x65) 3 System Name /Set 22 characters, only 20 Startco SHORT_ 600 significant. 102 (0x66) 4 Password /Set 22 characters, only 4 significant. 1111 SHORT_ 590 103 (0x67) 5 Password /Set Password timeout in minutes. 10, 1, 60 REAL 239 timeout 3.2 MESSAGE ROUTER No attributes supported for this object. 3.3 OBJECT DeviceNet Object Class Services _Attribute_Single: Returns contents of specified DeviceNet Class 3, Instance 0 Attributes 1 Revision Revision of the DeviceNet object class. Definition upon which the implementation is based. DeviceNet Object Instance Services _Attribute_Single: Returns contents of specified Set_Attribute_Single: Modify specified Allocate_Master/Slave_Connection_Set. Release_Master/Slave_Connection_Set. 1 UINT

DeviceNet Interface Page 4 DeviceNet Class 3, Instance 1 Attributes 1 MAC ID /Set (1) Node Address 63, 0, 63 USINT 2 Baud Rate /Set The baud rate of the device: 0 125 kb 1 250 kb 2 500 kb 3 Bus-Off Interrupt /Set (1) Define Processing of BOI: 0 = Hold CAN in Reset 1 = Automatic CAN Reset, Connections are Lost. Value set to 0 when driver is started. 4 Bus-Off Counter /Set (1) Number of times CAN went to the bus-off state. Writing any value clears counter. Count held at 255. Count cleared when driver is started. 5 Allocation Information Master/Slave Allocation Indication 0, 0, 2 USINT 0, 1, 0 BOOL 0, 0, 255 USINT Array BYTE, USINT DeviceNet Class 3, Instance 1 Attributes (Continued) SERVICE S 100 (0x64) 6 Net Trip Action /Set Trip Action taken by on 0, 0, 7 UINT 381 communication error: 0 = Disable 1 = Trip1 2 = Trip2 3 = Trip3 4 = Trip1 & Trip2 5 = Trip1 & Trip3 6 = Trip1 & Trip2 & Trip3 7 = Trip2 & Trip3 101 (0x65) 7 Net Alarm Action /Set Action taken on communication 0, 0, 7 UINT 382 error: 0 = Disable 1 = Alarm1 2 = Alarm2 3 = Alarm3 4 = Alarm1 & Alarm2 5 = Alarm1 & Alarm3 6 = Alarm1 & Alarm2 & Alarm3 7 = Alarm2 & Alarm3 102 (0x66) 8 Net Count Count the number of network trips. UINT 1191 (1) Takes effect on power-up reset or by a reset request to the Identity Object. Does not conform to A19.

DeviceNet Interface Page 5 3.4 CONNECTION OBJECT Connection Object Class Services _Attribute_Single: Returns contents of specified Set_Attribute_Single: Modify specified DeviceNet Connection Class 5, Instance 0 Attributes 1 Revision Revision of this Connection Object Class. 100 (0x64) 10 Polled Cons ID /Set Specifies output assembly ID for polled connection: (1) 0 = None (Empty EPATH) 1 = Basic Overload (0x02) 2 = Basic Motor Starter (0x03) 101 (0x65) 11 Polled Prod ID /Set Specifies Input assembly ID for polled connection: (2) 0 = None (Empty EPATH) 1 = Basic Overload (0x32) 2 = Extended Overload (0x33) 3 = Basic Motor Starter (0x34) 4 = Extended Motor Starter (0x35) 5 = User Registers (0x64) (1) Can also be set using Class 5, Instance 2, Attribute 16 path. (2) Can also be set using Class 5, Instance 2, Attribute 14 path. 1 UINT 2, 0, 2 UINT 5, 0, 5 UINT

DeviceNet Interface Page 6 Connection Object Instance Services _Attribute_Single: Returns contents of specified Set_Attribute_Single: Modify specified Delete: Delete specified connection instance. Reset: Reset the connection instance. DeviceNet Connection Class 5, Explicit Connection Instance 1 Attributes 1 State State of the object: 0 = Nonexistent 1 = Configuring 3 = Established 4 = Timed Out 5 = Deferred Delete 2 Instance Type Indicates either IO or messaging connection. 3 Transport Class Trigger 4 Produced Cnxn ID Placed in CAN Identifier field when the Connection Transmits. 5 Consumed Cnxn ID CAN Identifier Field value that denotes message to be received. 6 Initial Comm Characteristics 7 Produced Connection Size 8 Consumed Connection Size 9 Expected Packet Rate 12 (0x0C) Watchdog Timeout Action 13 (0x0D) Produced Connection Path Length 14 (0x0E) Produced Connection Path 15 (0x0F) Consumed Connection Path Length 16 (0x10) Consumed Connection Path 17 (0x11) Production Inhibit Time 1, 0, 5 USINT 0, 0, 0 USINT Defines behavior of the connection. 0x83 BYTE /Set /Set /Set Defines the Message Group(s) across which productions and consumptions associated with this Connection occur. Maximum number of bytes transmitted across this Connection. Maximum number of bytes received across this Connection. Defines timing (ms) associated with this Connection. Resolution is 10 ms. Defines how to handle inactivity/watchdog timeouts: 1 Auto Delete 3 Deferred Delete Number of bytes in the produced_connection_path length Application Object producing data on this connection. Number of bytes in the consumed_connection_path length Specifies the Application Object(s) that are to receive the data consumed by this Connection Object. Defines minimum time (ms) between new data production. UINT UINT BYTE 254 UINT 254 UINT 2500, 0, 65535, N/A 1, 1, 3 Set to 1 or 3 UINT USINT 0 UINT {} EPATH 0 UINT {} EPATH 0 UINT

DeviceNet Interface Page 7 DeviceNet Connection Class 5, Polled I/O Connection Instance 2 Attributes 1 State State of the object: 0, 0, 4 USINT 0 = Nonexistent 1 = Configuring 3 = Established 4 = Timed Out 2 Instance Type Indicates either IO or messaging 1, 0, 1 USINT connection: 0 = Explicit Message 1 = I/O Message 3 Transport Class Defines behavior of the connection. 0x83 BYTE Trigger 4 Produced Cnxn ID Placed in CAN Identifier field when UINT the Connection Transmits. 5 Consumed Cnxn ID CAN Identifier Field value that UINT 6 Initial Comm Characteristics 7 Produced Connection Size 8 Consumed Connection Size 9 Expected Packet Rate 12 (0x0C) Watchdog Timeout Action 13 (0x0D) Produced Connection Path Length 14 (0x0E) Produced Connection Path 15 (0x0F) Consumed Connection Path Length 16 (0x10) Consumed Connection Path 17 (0x11) Production Inhibit Time /Set /Set /Set /Set denotes message to be received. Defines the Message Group(s) across which productions and consumptions associated with this Connection occur. Maximum number of bytes transmitted across this Connection. Maximum number of bytes received across this Connection. Defines timing (ms) associated with this Connection. Defines how to handle inactivity/watchdog timeouts: 0 Transition to Time Out 1 Auto Delete 2 Auto Reset Number of bytes in the produced_connection_path length Symbolic notation. Application Object producing data on this connection. Number of bytes in the consumed_connection_path length Symbolic notation. Specifies the Application Object(s) that are to receive the data consumed by this Connection Object. Defines minimum time (ms) between new data production. BYTE Defined by UINT Assembly Instance Defined by UINT Assembly Instance 0, 0, 65535, UINT N/A, N/A 0, 0, 0 USINT 3, 3, 3 UINT 62 33 33 EPATH 3 UINT {} EPATH 0 UINT 3.5 ASSEMBLY OBJECT Assembly Object Class Services _Attribute_Single: Returns contents of specified Assembly Class 4, Instance 0 Attributes 1 Revision Revision of this object. 1 UINT 2 Max Instance Maximum instance of assembly. 0x64 UINT

DeviceNet Interface Page 8 Assembly Object Instance Services _Attribute_Single: Returns assembly-instance data. Applies to both output and input instances. Set_Attribute_Single: Set assembly instance data. Applies to output instances only. Service not supported for input instances. The following static input instances can be selected by setting DeviceNet Parameter 11 to the desired ID: PRODUCING ASSEMBLY ID INSTANCE SIZE IN BYTES SYMBOLIC IO CONNECTION PATH 5 100 (0x64) User Registers (Default) 64 62 36 34 1 50 (0x32) Basic Overload 1 62 33 32 2 51 (0x33) Extended Overload 1 62 33 33 3 52 (0x34) Basic Motor Starter 1 62 33 34 4 53 (0x35) Extended Motor Starter 1 1 62 33 35 The following static output instance can be selected by setting DeviceNet Parameter 10 to the desired ID: CONSUMING ASSEMBLY ID INSTANCE SIZE IN BYTES SYMBOLIC IO CONNECTION PATH 1 2 (0x02) Basic Overload 1 62 30 32 2 3 (0x03) Basic Motor Starter (Default) 1 62 30 33 Assemblies are configured using attributes 0x64 and 0x65 of Class 5, by selected by setting the Produced and Consumed connection path attribute in the Polled I/O connection instance, or by the Setup Hardware Network Comms menu. Setting the path to empty (no data), will disable production or consumption and the corresponding connection size will be zero. Assemblies are accessed using Polled I/O or can be read using Explicit Messaging. For explicit messaging, use class, instance, and attribute as indicated in Table 4. TABLE 4. EXPLICIT MESSAGING INSTANCE CLASS_INSTANCE_ 0x02 /Set 04_02_03 0x03 /Set 04_03_03 0x32 04_32_03 0x33 04_33_03 0x34 04_34_03 0x35 04_35_03 0x64 04_64_03 I/O Assembly Instance Attributes The following are the attributes that are supported as part of the Control Supervisor. These can be individually accessed and are also part of the pre-defined DeviceNet assemblies. Faulted This bit is 1 when there is a Trip1, Trip2, or Trip3 condition on the or 0 when there are no trips. Trips are reset using Explicit Messaging commands using 29-01-64, 29-01-0C or by using the FaultReset bit of the output assembly. Warning This bit is 1 when there is an Alarm1, Alarm2, or Alarm3 and 0 when there are no alarms. Running1 This bit is 1 when motor current is detected and 0 when there is no motor current. Ready This bit is 1 when there are no trips and the Remote Alarm set point is enabled. CtrlFromNet This bit is 1 when one of the output relays is assigned to Network Run1. The assigned relay will follow the state of the Run1 bit of the Control Supervisor attribute 3. This bit is also bit 1 of output assembly instance 3. Run1 When CtrlFromNet is 1, Run1 determines the state of the relay assigned to Network Run 1. When Run1 is 0, the relay is de-energized and when Run1 is 1 the relay is energized. Using this feature the PLC can provide remote start/stop control using the. NOTE: When the DeviceNet protocol starts or if an internal protocol error occurs, the Run1 bit is cleared.

DeviceNet Interface Page 9 FaultReset This bit is used to reset trips. A transition from 0 to 1 will issue a reset to the. This attribute is also updated when a Reset Trips command is issued using 29-01-64. When using 29-01-64 commands, a transition on the command or the FaultReset bit is not required. Assembly Class 4, Instance 0x64, Attribute 3 Produced Connection Path = 62 36 34 This assembly is used to access any combination of 32 user-defined registers in the. Assembly size is fixed at 64 bytes. User defined registers are programmed in the using the Setup Hardware Network Comms User Registers menu, or by explicit messaging to Class 0x64 via the configuration tool. Register values are not DeviceNet parameter numbers but are the register numbers defined in Appendix E of the manual. Each register in Appendix E defines a 16-bit value. For 32-bit float types (DeviceNet REAL), a register pair needs to be entered. For example, to configure an assembly to read the first four RTD temperatures in RTD Module 1, enter register numbers 902, 903, 904, 905, 906, 907, 908, 909 in order. The first 16 bytes of the assembly will contain the RTD data and the remaining bytes do not contain any valid data. Build assemblies so that REAL types fall on a 32-bit boundry. This simplifies access and type conversions within the PLC s DeviceNet scanner. NOTE: Byte order follows the DeviceNet convention and is not the same as indicated in Appendix E of the manual, however 32-bit values are specified as 2 registers in order as per the above example. Input Assemblies INPUT CLASS CLASS INSTANCE ASSEMBLY BIT Bit 0 Faulted/Trip Control Supervisor 0x29 1 10 Bit 1 Warning Control Supervisor 0x29 1 11 Bit 2 Running 1 Control Supervisor 0x29 1 7 Bit 4 Ready Control Supervisor 0x29 1 9 Bit 5 Control From Net Control Supervisor 0x29 1 15 Assembly Class 4, Instance 0x32, Attribute 3 Input Basic Overload Produced Connection Path = 62 33 32 BYTE BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 0 Reserved Reserved Reserved Reserved Reserved Reserved Reserved Faulted/ Trip Assembly Class 4, Instance 0x33, Attribute 3 Input Extended Overload Produced Connection Path = 62 33 33 BYTE BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 0 Reserved Reserved Reserved Reserved Reserved Reserved Warning Faulted/ Trip Assembly Class 4, Instance 0x34, Attribute 3 Input Basic Starter Produced Connection Path = 62 33 34 BYTE BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 0 Reserved Reserved Reserved Reserved Reserved Running1 Reserved Faulted/ Trip Assembly Class 4, Instance 0x35, Attribute 3 Input Extended Motor Starter 1 Produced Connection Path = 62 33 35 BYTE BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 0 Reserved Reserved CtrlfromNet Ready Reserved Running1 Warning Faulted/ Trip

DeviceNet Interface Page 10 Output Assemblies OUTPUT CLASS CLASS INSTANCE ASSEMBLY BIT Bit 0 Run1 Control Supervisor 0x29 1 3 Bit 2 Fault Reset Control Supervisor 0x29 1 12 Assembly Class 4, Instance 0x02, Attribute 3 Output Basic Overload Consumed Connection Path = 62 30 32 BYTE BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 0 Reserved Reserved Reserved Reserved Reserved FaultReset Reserved Reserved Assembly Class 4, Instance 0x03, Attribute 3 Output Basic Motor Starter Consumed Connection Path = 62 30 33 BYTE BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 0 Reserved Reserved Reserved Reserved Reserved FaultReset Reserved Run1 3.6 CONTROL SUPERVISOR OBJECT Control Supervisor Class 0x29, Instance 0 Attributes 1 Revision Revision of this object. 1 UINT 2 Max Instance Maximum number of instances. 1 UINT Supervisor Object Instance Services _Attribute_Single: Returns contents of specified Set_Attribute_Single: Modifies specified Reset: Resets attributes 3, 12, 100 Supervisor Class 0x29, Instance 1 Attributes 3 Run1 (1) /Set Run 1 Input to 0, 0, 1 BOOL 7 Running Motor Current Detected 0, 0, 1 BOOL 9 Ready No Trips and Run1 Enabled 0, 0, 1 BOOL 10 (0x0A) Faulted is tripped. 0, 0, 1 BOOL 11 (0x0B) Warning in alarm. 0, 0, 1 BOOL 12 (0x0C) FaultReset /Set Reset issued on 0 - >1 transition. 0, 0, 1 BOOL 15 (0x0F) CtrlFromNet 1 = Relay Assigned to Network Run1 N/A BOOL (1) At least one relay must be assigned to Network Run1.

DeviceNet Interface Page 11 Supervisor Class 0x29, Instance 1 Attributes (Continued) 100 (0x64) 15 Command /Set A command Set will cause the requested command to be issued to the. A "" will read the last command. 0 = Reserved 1 = Reserved 2 = Reserved 3 = Reset Trips 4 = Set RTC 5 = Clear Data Logging Records 6 = Clear Trips Counters 7 = Reserved 8 = Clear Running Time 9 = Emergency I²t Reset 10 = Reserved 11 = Reserved 12 = Re-enable Temperature Protection 13 = Remote/Net Trip Set 14 = Remote/Net Trip Clear 15 = Remote/Net Alarm Set 16 = Remote/Net Alarm Clear 17 = Run1 Set 18 = Run1 Clear 101 (0x65) 16 TA Summary Trip, Alarm, Status Summary: Bit 4: 1 = Trip1 Bit 5: 1 = Trip2 Bit 6: 1 = Trip3 Bit 7: 1 = Alarm1 Bit 8: 1 = Alarm2 Bit 9: 1 = Alarm3 102 (0x66) 17 Status 103 (0x67) 18 Trip/Alarm Group 0 104 (0x68) 19 Trip/Alarm Group 1 105 (0x69) 20 Trip/Alarm Group 2 106 (0x6A) 21 Trip/Alarm Group 3 107 (0x6B) 22 Trip/Alarm Group 4 108 (0x6C) 23 Trip/Alarm Group 5 109 (0x6D) 24 Trip/Alarm Group 6 110 (0x6E) 25 Trip/Alarm Group 7 Bit 0: 1 = I > Threshold Bit 1: 1 = In run mode Bit 2: 1 = Reduced OC on Bit 3: 1 = I > 125% FLA Bit 4: 1 = ETR on Bit 5: 1 = PTC open Bit 8: 1 = Digital Input valid Bit 9: 1 = RY1 energized Bit 10: 1 = RY2 energized Bit 11: 1 = RY3 energized Trip and Alarm, Bits 15..0, T45 See Manual, Appendix F. Trip and Alarm, Bits 31..16, T46 See Manual, Appendix F. Trip and Alarm, Bits 47..32, T47 See Manual, Appendix F. Trip and Alarm, Bits 63..48, T48 See Manual, Appendix F. Trip and Alarm, Bits 79..64, T49 See Manual, Appendix F. Trip and Alarm, Bits 95..80, T50 See Manual, Appendix F. Trip and Alarm, Bits 111..96, T51 See Manual, Appendix F. Trip and Alarm, Bits 127..112, T52 See Manual, Appendix F. 0, 0, 18 USINT 0, 0, 512 WORD 1096 0, 0, 2048 WORD 1097 UINT 1104 UINT 1105 UINT 1106 UINT 1107 UINT 1108 UINT 1109 UINT 1110 UINT 1111

DeviceNet Interface Page 12 Supervisor Class 0x29, Instance 1 Attributes (Continued) 111 (0x6F) 26 RY1 Function /Set Function Assigned to Relay 1: 0, 0, 12 UINT 334 0 = None 1 = Trip1 2 = Trip2 3 = Trip3 4 = Alarm1 5 = Alarm2 6 = Alarm3 7 = Current Detected 8 = Run Mode 9 = Start Inhibit 10 = Trip1 Pulse 11 = Watchdog 12 = Network Run1 13 = Reduced Overcurrent 112 (0x70) 27 RY1 Mode /Set 0 = Fail Safe, 1 = Non Fail Safe 0, 0, 1 UINT 335 113 (0x71) 28 RY2 Function /Set See Attribute 0x6F 0, 0, 18 UINT 336 114 (0x72) 29 RY2 Mode /Set 0 = Fail Safe, 1 = Non Fail Safe 0, 0, 1 UINT 337 115 (0x73) 30 RY3 Function /Set See Attribute 0x6F 0, 0, 18 UINT 338 116 (0x74) 31 RY3 Mode /Set 0 = Fail Safe, 1 = Non Fail Safe 0, 0, 1 UINT 339 117 (0x75) 32 RY Pulse Time /Set Specifies the duration of the trip pulse when the RY function is set 0.25, 0.25, 10 REAL 344/ 345 to Trip1 Pulse. 118 (0x76) 33 Din Function /Set Digital Input function selection: 0, 0, 3 UINT 264 0 = Input Not Used 1 = Trip1 2 = Reset 3 = Program Enable 4 = Reduced Overcurrent 119 (0x77) 34 Din Bypass /Set Applies when Trip1 is selected: 1, 0, 1 UINT 265 0 = Enable, 1 = Disable 120 (0x78) 35 Din Bypass Delay /Set Applies when Trip1 is selected. Sets the bypass delay on start. 5, 0.5, 100 REAL 266/ 267 121 (0x79) 36 Din Trip Delay /Set Applies when Trip1 is selected. 0.1, 0.01, 100 REAL 268/ 269 122 (0x7A) 37 Din Trip Count Number of times the Digital Input has tripped. UINT 1149 123 (0x7B) 38 Aout Param /Set Specifies the Analog Output 0, 0, 11 UINT 373 parameter: 0 = Phase Current (%CT) 1 = Earth Leakage (CT Measured) 2 = Earth Leakage (Calculated) 3 = Used I 2 t 4 = Local RTD 5 = Max Module Stator RTD 6 = Max Module Bearing RTD 7 = Max Module Load RTD 8 = Max Module Ambient RTD 9 = Unbalance 10 = Zero 11 = Full Scale 12 = Differential Current 13 = Phase Current (%FLA) 124(0x7C) 39 DF Enable /Set Differential Module Enable: 0 = Enable 1 = Disable 0, 1, 0 UINT 160

DeviceNet Interface Page 13 Supervisor Class 0x29, Instance 1 Attributes (Continued) 125 (0x7D) 40 OPI Trip Action /Set 0 = Disable 1 = Trip1 2 = Trip2 3 = Trip3 4 = Trip1 & Trip2 5 = Trip1 & Trip3 6 = Trip1 & Trip2 & Trip3 7 = Trip2 & Trip3 0, 0, 7 UINT 237 Number of OPI 12 ohm trips. UINT 1185 126 (0x7E) 41 OPI Trip Count 127 (0x7F) 42 Local Sensor /Set Selects the Local Temperature Sensor: 0 = Disabled 1 = RTD 2 = PTC 128 (0x80) 43 Local Sensor Count 129 (0x81) 44 Remote Trip Action 130 (0x82) 45 Remote Alarm Action /Set /Set Counts the number of times that the RTD Sensor Trip has occurred. 0 = Disable 1 = Trip1 2 = Trip2 3 = Trip3 4 = Trip1 & Trip2 5 = Trip1 & Trip3 6 = Trip1 & Trip2 & Trip3 7 = Trip2 & Trip3 0 = Disable 1 = Alarm1 2 = Alarm2 3 = Alarm3 4 = Alarm1 & Alarm2 5 = Alarm1 & Alarm3 6 = Alarm1 & Alarm2 & Alarm3 7 = Alarm2 & Alarm3 131 (0x83) 46 Remote Trip Count 132 (0x84) 47 UPI Select /Set Selects UPI Function: 0 = None 1 = Trip1 2 = Trip2 3 = Trip3 4 = Alarm1 5 = Alarm2 6 = Alarm3 7 = Relay1 8 = Relay2 9 = Relay3 10 = Digital Input 11 = Current Detected 12 = Current > 125% FLA 13 = In Run Mode 14 = ETR State 15 = Start Inhibit 16 = Network Run1 17 = Net Activity 18 = Reduced Overcurrent 0, 0, 2 UINT 143 UINT 1195 0, 0, 7 UINT 140 0, 0, 7 UINT 141 Number of Remote Trips UINT 1197 0, 0, 17 UINT 241

DeviceNet Interface Page 14 Supervisor Class 0x29, Instance 1 Attributes (Continued) 133 (0x85) 48 DF MOD Trip Action 134 (0x86) 49 DF MOD Alarm Action 135 (0x87) 99 DF Mod Count 136 (0x88) 14 Trip/Alarm Group 8 /Set 0 = Disable 1 = Trip1 2 = Trip2 3 = Trip3 4 = Trip1 & Trip2 5 = Trip1 & Trip3 6 = Trip1 & Trip2 & Trip3 7 = Trip2 & Trip3 /Set 0 = Disable 1 = Alarm1 2 = Alarm2 3 = Alarm3 4 = Alarm1 & Alarm2 5 = Alarm1 & Alarm3 6 = Alarm1 & Alarm2 & Alarm3 7 = Alarm2 & Alarm3 Differential Module Communications Trip Count Trip and Alarm Bits 143.. 128 T53 See Manual, Appendix F. 137 (0x89) 13 Default Menu /Set Default Menu: 0 = Main 1 = Current 2 = Unbalance 3 = Earth Leakage 4 = Thermal Capacity 5 = Differential 6 = RTD Module 7 = Local Sensor 8 = I/O Status 9 = System Status 10 = Network Status 0, 0, 7 UINT 161 0, 0, 7 UINT 162 UINT 1138 UINT 1112 0,0,10 UINT 242 3.7 OVERLOAD Overload Object Class Services _Attribute_Single: Returns contents of specified Overload Class 0x2C, Instance 0 Attributes 1 Revision Revision of this object. 1 UINT 2 Max Instance Maximum number of instances. 1 UINT Overload Object Instance Services _Attribute_Single: Returns contents of specified Set_Attribute_Single: Modify specified

DeviceNet Interface Page 15 Overload Class 0x2C, Instance 1 Attributes 100 (0x64) 50 Trip Action /Set 0 = Disable 1, 0, 7 UINT 8 1 = Trip1 2 = Trip2 3 = Trip3 4 = Trip1 & Trip2 5 = Trip1 & Trip3 6 = Trip1 & Trip2 & Trip3 7 = Trip2 & Trip3 101 (0x65) 51 Thermal /Set 0 = NEMA 0, 0, 1 UINT 9 Model 1 = I²t 52 Reserved 102 (0x66) 53 K-Factor /Set Used in I²t Algorithm 6, 1, 10 REAL 11/12 103 (0x67) 54 LR Current /Set Locked Rotor Current (x FLA) 6, 1, 10 REAL 13/14 104 (0x68) 55 LR Time Cold /Set Locked Rotor Time Cold (s) 10, 0.1, REAL 15/16 100 105 (0x69) 56 LR Time Hot /Set Locked Rotor Time Hot (s) 5, 0.1, 100 REAL 17/18 106 (0x6A) 57 Cooling /Set Multiples of Running Time 2, 0.1, 10 REAL 19/20 Factor Constant 107 (0x6B) 58 Inhibit Level /Set Thermal Reset/Inhibit Level per 0.3, 0.1, REAL 21/22 Unit 0.9 108 (0x6C) 59 Alarm Level /Set Level Where Alarm Occurs 1.0, 0.5, REAL 23/24 109 (0x6D) 60 Alarm Action /Set 0 = Disable 1 = Alarm1 2 = Alarm2 3 = Alarm3 4 = Alarm1 & Alarm2 5 = Alarm1 & Alarm3 6 = Alarm1 & Alarm2 & Alarm3 7 = Alarm2 & Alarm3 110 (0x6E) 61 Inhibit Trip Action 111 (0x6F) 62 Inhibit Alarm Action 112 (0x70) 63 Inhibit Trip Count 113 (0x71) 64 EF Source Earth Fault Protection Source: 0 = Calculated (3I 0 ) 1 = Measured (Ict) 114 (0x72) 65 PH-CT Primary 115 (0x73) 66 EF-CT Primary 116 (0x74) 67 Run-Mode Delay 117 (0x75) 68 Frequency /Set System Frequency: 0 = 50, 1 = 60 Hz, 2 = Variable 1.0 1, 0, 7 UINT 25 /Set 0, 0, 7 UINT 26 /Set 0, 0, 7 UINT 27 UINT 1196 1, 0, 1 UINT 208 /Set Phase CT Primary Rating (A) 100, 1, REAL 210 5000 /Set EF-CT Primary Rating (A) 5, 1, 5000 REAL 212 /Set 10, 5, 60 REAL 216 118 (0x76) 69 FLA Rating /Set Full-Load Current 100, 1, 5000 119 (0x77) 70 DF-CT /Set Differential CT Primary Rating 100, 1, Primary 5000 1, 0, 1 UINT 224 REAL 225/ 226 REAL 218/219

DeviceNet Interface Page 16 Overload Class 0x2C, Instance 1 Attributes 120 (0x78) 71 Service Factor /Set Motor Service Factor 1, 1, 1.25 REAL 233/ 234 121 (0x79) 72 Trip Count Counts Overload Trips UINT 1132 122 (0x7A) 73 Starts / Hour Trip Action 123 (0x7B) 74 Starts / Hour Alarm Action 124 (0x7C) 75 Number of Starts / Hour -Set /Set /Set 0 = Disable 1 = Trip1 2 = Trip2 3 = Trip3 4 = Trip1 & Trip2 5 = Trip1 & Trip3 6 = Trip1 & Trip2 & Trip3 7 = Trip2 & Trip3 0 = Disable 1 = Alarm1 2 = Alarm2 3 = Alarm3 4 = Alarm1 & Alarm2 5 = Alarm1 & Alarm3 6 = Alarm1 & Alarm2 & Alarm3 7 = Alarm2 & Alarm3 1 to 10 Starts per Hour: 0 = 1 Start 9 = 10 Starts 0, 0, 7 UINT 1270 0, 0, 7 UINT 1271 0, 0, 9 UINT 1272 125 (0x7D) 76 Time between Starts /Set 0 to 500 Minutes Between Starts 0, 0, 500 m REAL 1273/ 1274 126 (0x7E) 77 Starts / Hour Number of Starts/Hour trips UINT 1193 Trip Count 144 (0x90) 78 I A Phase A Current (A) REAL 860/861 145 (0x91) 79 I B Phase B Current (A) REAL 862/863 146 (0x92) 80 I C Phase C Current (A) REAL 864/865 147 (0x93) 81 Ict Ground-Fault Current (A) from CT REAL 866/867 148 (0x94) 82 3I 0 Ground-Fault Current (A) Calculated REAL 868/869 149 (0x95) 83 +Seq Current Positive Sequence Current (Pu) REAL 870/871 150 (0x96) 84 -Seq Current Negative Sequence Current (Pu) REAL 872/873 151 (0x97) 85 Unbalance Current Unbalance (Pu) REAL 874/875 Current 152 (0x98) 86 Used I 2 t Used Thermal Capacity (pu). REAL 876/877 Scaled to % 153 (0x99) 87 Thermal Thermal Trend (pu). REAL 878/879 Trend Scaled to % 154 (0x9A) 88 Frequency Frequency (from Ia) REAL 880/881 155 (0x9B) 89 Local RTD Load RTD Reading REAL 900/901 156 (0x9C) 90 Run Time Motor Run Time in seconds. Scaled by 1/3600 for display in hours. UDINT 1210/ 1211 157 (0x9D) 91 Overload Reset Type /Set 0 = Normal 1 = Auto Reset 2 = Multiple Motor Sequence UINT 28 158 (0x9E) 92 I 2 t Reset I 2 t Reset/Inhibit Time (m) REAL 882/883 Time 159 (0x9F) 93 DFa Differential Current A REAL 884/885 160 (0xA0) 94 DFb Differential Current B REAL 886/887 161 (0xA1) 95 DFc Differential Current C REAL 888/889

DeviceNet Interface Page 17 3.8 SET POINT CLASS 0x64 Set Point Object Class Services _Attribute_Single: Returns contents of specified Set Point Class 0x64, Instance 0 Attributes 1 Revision Revision of this object. 5 UINT 2 Max Instance Maximum number of instances. 12 UINT Set Point Object Instances Set Point Object Instance Services _Attribute_Single: Returns contents of specified Set_Attribute_Single: Modifies specified The set point class consists of seven attributes. Each set-point instance may use some or all of these attributes. Attribute 1 - Trip Action Specifies the action to take on a trip. 0 = Disable 1 = Trip1 2 = Trip2 3 = Trip3 4 = Trip1 & Trip2 5 = Trip1 & Trip3 6 = Trip1 & Trip2 & Trip3 7 = Trip2 & Trip3 Attribute 2 - Alarm Action Specifies the action to take on an alarm. 0 = Disable 1 = Alarm1 2 = Alarm2 3 = Alarm3 4 = Alarm1 & Alarm2 5 = Alarm1 & Alarm3 6 = Alarm1 & Alarm2 & Alarm3 7 = Alarm2 & Alarm3 Attribute 3 - Trip Level Attribute 4 - Trip Delay Attribute 5 - Alarm Level Attribute 6 - Alarm Delay Attribute 7 - Trip Counter for the set point Class 0x64, Instance 1 - Overcurrent 1 100 Trip Action /Set 1, 0, 7 UINT 32 3 101 Trip Level /Set 10, 1, 15 REAL 33/34 4 102 Trip Delay /Set 0.1, 0, 10 REAL 35/36 7 103 Trip Count UINT 1130 Class 0x64, Instance 2 - Aux. Overcurrent 1 104 Trip Action /Set 1, 0, 7 UINT 40 3 105 Trip Level /Set 10, 1, 15 REAL 41/42 4 106 Trip Delay /Set 0.1, 0, 10 REAL 43/44 7 107 Trip Count UINT 1131

DeviceNet Interface Page 18 Class 0x64, Instance 3 - Earth Fault 1 108 Trip Action /Set 1, 0, 7 UINT 48 2 109 Alarm Action /Set 1, 0, 7 UINT 58 3 110 Trip Level /Set 0.4, 0.05, 1 REAL 50/51 4 111 Trip Delay /Set 0.25, 0, 100 REAL 52/53 5 112 Alarm Level /Set 0.20, 0.05, 1 REAL 54/55 6 113 Alarm Delay /Set 1, 0, 100 REAL 56/57 7 114 Trip Count UINT 1133 Class 0x64, Instance 4 Jam 1 115 Trip Action /Set 1, 0, 7 UINT 64 2 116 Alarm Action /Set 1, 0, 7 UINT 73 3 117 Trip Level /Set 6, 1, 10 REAL 65/66 4 118 Trip Delay /Set 5, 1, 100 REAL 67/68 5 119 Alarm Level /Set 3, 1, 10 REAL 69/70 6 120 Alarm Delay /Set 5, 1, 100 REAL 71/72 7 121 Trip Count UINT 1136 Class 0x64, Instance 5 - Current Unbalance 1 122 Trip Action /Set 1, 0, 7 UINT 80 2 123 Alarm Action /Set 1, 0, 7 UINT 89 3 124 Trip Level /Set 0.25, 0.05, 1 REAL 81/82 4 125 Trip Delay /Set 15, 1, 100 REAL 83/84 5 126 Alarm Level /Set 0.10, 0.05, 1 REAL 85/86 6 127 Alarm Delay /Set 10, 1, 100 REAL 87/88 7 128 Trip Count UINT 1134 Class 0x64, Instance 6 - Phase Reverse 1 129 Trip Action /Set 0, 0, 7 UINT 96 2 130 Alarm Action /Set 0, 0, 7 UINT 93 4 131 Trip Delay /Set 2, 1, 100 REAL 97/98 6 132 Alarm Delay /Set 2, 1, 100 REAL 94 7 133 Trip Count UINT 1144 Class 0x64, Instance 7 - Phase Loss 1 134 Trip Action /Set 1, 0, 7 UINT 99 2 135 Alarm Action /Set 1, 0, 7 UINT 102 4 136 Trip Delay /Set 5, 1, 100 REAL 100 6 137 Alarm Delay /Set 5, 1, 100 REAL 103 7 138 Trip Count UINT 1143

DeviceNet Interface Page 19 Class 0x64, Instance 8 Undercurrent 1 139 Trip Action /Set 0, 0, 7 UINT 128 2 140 Alarm Action /Set 0, 0, 7 UINT 137 3 141 Trip Level /Set 0.5, 0.1, 1 REAL 129 4 142 Trip Delay /Set 10, 1, 100 REAL 131 5 143 Alarm Level /Set 0.8, 0.1, 1 REAL 133 6 144 Alarm Delay /Set 20, 1, 100 REAL 135 7 145 Trip Count UINT 1137 Class 0x64, Instance 9 - PTC Temperature 1 146 Trip Action /Set 0, 0, 7 UINT 144 2 147 Alarm Action /Set 0, 0, 7 UINT 145 7 148 Trip Count UINT 1142 Class 0x64, Instance 0x0A Local RTD Sensor 1 149 Trip Action /Set 1, 0, 7 UINT 146 2 150 Alarm Action /Set 1, 0, 7 UINT 151 3 151 Trip Level /Set 130, 40, 200 REAL 147 5 152 Alarm Level /Set 110, 40, 200 REAL 149 7 153 Trip Count UINT 1194 Class 0x64, Instance 0x0B Reduced Overcurrent 1 154 Trip Action /Set 0, 0, 7 UINT 45 3 155 Trip Level /Set 1, 1, 15 REAL 46/47 7 156 Trip Count UINT 1140 Class 0x64, Instance 0x0C Differential Overcurrent 1 465 Trip Action /Set 0, 0, 7 UINT 170 2 466 Alarm Action /Set 0, 0, 7 UINT 179 3 467 Trip Level /Set 1, 0.1, 15 REAL 171/172 4 468 Trip Delay /Set 0.1, 0, 10 REAL 173/174 5 469 Alarm Level /Set 0.5, 0.1, 15 REAL 175/176 6 470 Alarm Delay /Set 0.1, 0, 10 REAL 177/178 7 471 Trip Count UINT 1139

DeviceNet Interface Page 20 3.9 RTD MODULE CLASS 0x65 RTD Module Object Class Services _Attribute_Single: Returns contents of specified Set_Attribute_Single: Modifies specified Class 0x65, Instance 0, Attributes Revision number of this class. 1 UINT 1 Revision Number 2 Max Instance Maximum number of RTD modules. 100 (0x64) 160 Modules Used /Set Specifies the number of RTD modules used. 101 (0x65) 161 Sensor Trip /Set Specifies trip action to take on a Action (1) sensor error: 0 = Disable Trips 1 = Trip1 2 = Trip2 3 = Trip3 4 = Trip1 & Trip2 5 = Trip1 & Trip3 6 = Trip1 & Trip2 & Trip3 7 = Trip2 & Trip3 /Set Specifies alarm action to take on a 102 (0x66) 162 Sensor Alarm Action (1) sensor error: 0 = Disable Alarms 1 = Alarm1 2 = Alarm2 3 = Alarm3 4 = Alarm1 & Alarm2 5 = Alarm1 & Alarm3 6 = Alarm1 & Alarm2 & Alarm3 7 = Alarm2 & Alarm3 103 (0x67) 163 Module Error Trip Action 104 (0x68) 164 Module Error Alarm Action 105 (0x69) 165 Module1 Comm Trip Count 106 (0x6A) 166 Module2 Comm Trip Count 107 (0x6B) 167 Module3 Comm Trip Count 108 (0x6C) 168 Module Sensor Trip Count 109 (0x6D) 169 HMC /Set /Set Specifies trip action to take on a module error. Action list is the same as Attribute 9. Specifies alarm action to take on a module error. Action list is the same as Attribute A. Number of module1 communication-error trips. Number of module2 communication-error trips. Number of module3 communication-error trips. 3 UINT 0, 0, 3 UINT 390 0, 0, 7 UINT 388 1, 0, 7 UINT 389 0, 0, 7 UINT 387 1, 0, 7 UINT 386 UINT 1180 UINT 1181 UINT 1182 Number of RTD sensor trips. UINT 1183 /Set Stator temperature ( C) where Enable (1) 0 = Enable, 1 = Disable /Set Hot Motor Compensation control: 110 (0x6E) 170 HMC Max Bias (1) compensation ends at 100% I²t. 150, 40, 200 UINT 550 REAL 551/ 552

DeviceNet Interface Page 21 Class 0x65, Instance 0, Attributes (Continued) RTD Module Object Instance Services _Attribute_Single: Returns contents of specified Set_Attribute_Single: Modifies specified /Set Stator temperature ( C) where 111 (0x6F) 171 HMC Min 40, 40, 200 REAL 553/ Bias (1) compensation begins at 0% I²t. 554 112 (0x70) 172 Max Stator Temp Maximum Stator Temperature ( C) REAL 950/ 951 113 (0x71) 173 Max Bearing Temp Maximum Bearing Temperature ( C) REAL 952/ 953 114 (0x72) 174 Max Load Temp Maximum Load Temperature ( C) REAL 954/ 955 115 (0x73) 175 Max Amb Temp Maximum Ambient Temperature ( C) REAL 956/ 957 116 (0x74) 176 Min Stator Temp Minimum Stator Temperature ( C) REAL 958/ 959 117 (0x75) 177 Min Bearing Temp Minimum Bearing Temperature ( C) REAL 960/ 961 118 (0x76) 178 Min Load Temp Minimum Load Temperature ( C) REAL 962/ 963 119 (0x77) 179 Min Ambient Temp Minimum Ambient Temperature ( C) REAL 964/ 965 (1) Also applies to local RTD sensor Object Instance Attributes 0x11 to 0x20 define the trip and alarm settings in degrees C. The trip action is fixed as Trip1 and the alarm action is fixed as Alarm1. Object Instance Attributes 0x21 to 0x28 define an 18- character name. Object Instance Attributes 1 to 8 define the RTD type. Selecting an RTD will enable trip and alarm set points. The trip action is fixed as Trip1 and the alarm action is fixed as Alarm1. 0 = RTD Disabled 1 = Platinum 100 ohm 2 = Nickel 100 ohm 3 = Nickel 120 ohm 4 = Copper 10 ohm Object Instance Attributes 0x29 to 0x30 are temperature readings. Object Instance Attributes 0x31 to 0x38 are the trip counters for each of the RTD's. Object Instance Attributes 0x09 to 0x10 define the RTD function. 0 = Stator 1 = Bearing 2 = Load 3 = Ambient

DeviceNet Interface Page 22 Class 0x65, Instance 1 1 190 RTD #1 Type /Set 0, 0, 4 UINT 391 2 191 RTD #2 Type /Set 0, 0, 4 UINT 392 3 192 RTD #3 Type /Set 0, 0, 4 UINT 393 4 193 RTD #4 Type /Set 0, 0, 4 UINT 394 5 194 RTD #5 Type /Set 0, 0, 4 UINT 395 6 195 RTD #6 Type /Set 0, 0, 4 UINT 396 7 196 RTD #7 Type /Set 0, 0, 4 UINT 397 8 197 RTD #8 Type /Set 0, 0, 4 UINT 398 9 198 RTD #1 Function /Set 0, 0, 7 UINT 415 10 (0x0A) 199 RTD #2 Function /Set 0, 0, 7 UINT 416 11 (0x0B) 200 RTD #3 Function /Set 0, 0, 7 UINT 417 12 (0x0C) 201 RTD #4 Function /Set 0, 0, 7 UINT 418 13 (0x0D) 202 RTD #5 Function /Set 0, 0, 7 UINT 419 14 (0x0E) 203 RTD #6 Function /Set 0, 0, 7 UINT 420 15 (0x0F) 204 RTD #7 Function /Set 0, 0, 7 UINT 421 16 (0x10) 205 RTD #8 Function /Set 0, 0, 7 UINT 422 17 (0x11) 206 RTD #1 Trip Level /Set 130, 40, 200 REAL 446/447 18 (0x12) 207 RTD #1 Alarm Level /Set 110, 40, 200 REAL 448/449 19 (0x13) 208 RTD #2 Trip Level /Set 130, 40, 200 REAL 450/451 20 (0x14) 209 RTD #2 Alarm Level /Set 110, 40, 200 REAL 452/453 21 (0x15) 210 RTD #3 Trip Level /Set 130, 40, 200 REAL 454/455 22 (0x16) 211 RTD #3 Alarm Level /Set 110, 40, 200 REAL 456/457 23 (0x17) 212 RTD #4 Trip Level /Set 130, 40, 200 REAL 458/459 24 (0x18) 213 RTD #4 Alarm Level /Set 110, 40, 200 REAL 460/461 25 (0x19) 214 RTD #5 Trip Level /Set 130, 40, 200 REAL 462/463 26 (0x1A) 215 RTD #5 Alarm Level /Set 110, 40, 200 REAL 464/465 27 (0x1B) 216 RTD #6 Trip Level /Set 130, 40, 200 REAL 466/467 28 (0x1C) 217 RTD #6 Alarm Level /Set 110, 40, 200 REAL 468/469 29 (0x1D) 218 RTD #7 Trip Level /Set 130, 40, 200 REAL 470/471 30 (0x1E) 219 RTD #7 Alarm Level /Set 110, 40, 200 REAL 472/473 31 (0x1F) 220 RTD #8 Trip Level /Set 130, 40, 200 REAL 474/475 32 (0x20) 221 RTD #8 Alarm Level /Set 110, 40, 200 REAL 476/477 33 (0x21) 222 RTD #1 Name /Set RTD M1 #1 SHORT_ 610 34 (0x22) 223 RTD #2 Name /Set RTD M1 #2 SHORT_ 620 35 (0x23) 224 RTD #3 Name /Set RTD M1 #3 SHORT_ 630 36 (0x24) 225 RTD #4Name /Set RTD M1 #4 SHORT_ 640 37 (0x25) 226 RTD #5 Name /Set RTD M1 #5 SHORT_ 650 38 (0x26) 227 RTD #6 Name /Set RTD M1 #6 SHORT_ 660 39 (0x27) 228 RTD #7 Name /Set RTD M1 #7 SHORT_ 670 40 (0x28) 229 RTD #8 Name /Set RTD M1 #8 SHORT_ 680 41 (0x29) 230 RTD #1 Temp RDG REAL 902/903 42 (0x2A) 231 RTD #2 Temp RDG REAL 904/905 43 (0x2B) 232 RTD #3 Temp RDG REAL 906/907 44 (0x2C) 233 RTD #4 Temp RDG REAL 908/909 45 (0x2D) 234 RTD #5 Temp RDG REAL 910/911 46 (0x2E) 235 RTD #6 Temp RDG REAL 912/913 47 (0x2F) 236 RTD #7 Temp RDG REAL 914/915 48 (0x30) 237 RTD #8 Temp RDG REAL 916/917

DeviceNet Interface Page 23 Class 0x65, Instance 1 (Continued) 49 (0x31) 238 RTD #1 Trip Cntr UINT 1156 50 (0x32) 239 RTD #2 Trip Cntr UINT 1157 51 (0x33) 240 RTD #3 Trip Cntr UINT 1158 52 (0x34) 241 RTD #4 Trip Cntr UINT 1159 53 (0x35) 242 RTD #5 Trip Cntr UINT 1160 54 (0x36) 243 RTD #6 Trip Cntr UINT 1161 55 (0x37) 244 RTD #7 Trip Cntr UINT 1162 56 (0x38) 245 RTD #8 Trip Cntr UINT 1163 Class 0x65, Instance 2 1 250 RTD #1 Type /Set 0, 0, 4 UINT 399 2 251 RTD #2 Type /Set 0, 0, 4 UINT 400 3 252 RTD #3 Type /Set 0, 0, 4 UINT 401 4 253 RTD #4 Type /Set 0, 0, 4 UINT 402 5 254 RTD #5 Type /Set 0, 0, 4 UINT 403 6 255 RTD #6 Type /Set 0, 0, 4 UINT 404 7 256 RTD #7 Type /Set 0, 0, 4 UINT 405 8 257 RTD #8 Type /Set 0, 0, 4 UINT 406 9 258 RTD #1 Function /Set 0, 0, 7 UINT 423 10 (0x0A) 259 RTD #2 Function /Set 0, 0, 7 UINT 424 11 (0x0B) 260 RTD #3 Function /Set 0, 0, 7 UINT 425 12 (0x0C) 261 RTD #4 Function /Set 0, 0, 7 UINT 426 13 (0x0D) 262 RTD #5 Function /Set 0, 0, 7 UINT 427 14 (0x0E) 263 RTD #6 Function /Set 0, 0, 7 UINT 428 15 (0x0F) 264 RTD #7 Function /Set 0, 0, 7 UINT 429 16 (0x10) 265 RTD #8 Function /Set 0, 0, 7 UINT 430 17 (0x11) 266 RTD #1 Trip Level /Set 130, 40, 200 REAL 478/479 18 (0x12) 267 RTD #1 Alarm Level /Set 110, 40, 200 REAL 480/481 19 (0x13) 268 RTD #2 Trip Level /Set 130, 40, 200 REAL 482/483 20 (0x14) 269 RTD #2 Alarm Level /Set 110, 40, 200 REAL 484/485 21 (0x15) 270 RTD #3 Trip Level /Set 130, 40, 200 REAL 486/487 22 (0x16) 271 RTD #3 Alarm Level /Set 110, 40, 200 REAL 488/489 23 (0x17) 272 RTD #4 Trip Level /Set 130, 40, 200 REAL 490/491 24 (0x18) 273 RTD #4 Alarm Level /Set 110, 40, 200 REAL 492/493 25 (0x19) 274 RTD #5 Trip Level /Set 130, 40, 200 REAL 494/495 26 (0x1A) 275 RTD #5 Alarm Level /Set 110, 40, 200 REAL 496/497 27 (0x1B) 276 RTD #6 Trip Level /Set 130, 40, 200 REAL 498/499 28 (0x1C) 277 RTD #6 Alarm Level /Set 110, 40, 200 REAL 500/501 29 (0x1D) 278 RTD #7 Trip Level /Set 130, 40, 200 REAL 502/503 30 (0x1E) 279 RTD #7 Alarm Level /Set 110, 40, 200 REAL 504/505 31 (0x1F) 280 RTD #8 Trip Level /Set 130, 40, 200 REAL 506/507 32 (0x20) 281 RTD #8 Alarm Level /Set 110, 40, 200 REAL 508/509 33 (0x21) 282 RTD #1 Name /Set RTD M2 #1 SHORT_ 690 34 (0x22) 283 RTD #2 Name /Set RTD M2 #2 SHORT_ 700 35 (0x23) 284 RTD #3 Name /Set RTD M2 #3 SHORT_ 710 36 (0x24) 285 RTD #4Name /Set RTD M2 #4 SHORT_ 720

DeviceNet Interface Page 24 Class 0x65, Instance 2 (Continued) 37 (0x25) 286 RTD #5 Name /Set RTD M2 #5 SHORT_ 730 38 (0x26) 287 RTD #6 Name /Set RTD M2 #6 SHORT_ 740 39 (0x27) 288 RTD #7 Name /Set RTD M2 #7 SHORT_ 750 40 (0x28) 289 RTD #8 Name /Set RTD M2 #8 SHORT_ 760 41 (0x29) 290 RTD #1 Temp RDG REAL 918/919 42 (0x2A) 291 RTD #2 Temp RDG REAL 920/921 43 (0x2B) 292 RTD #3 Temp RDG REAL 922/923 44 (0x2C) 293 RTD #4 Temp RDG REAL 924/925 45 (0x2D) 294 RTD #5 Temp RDG REAL 926/927 46 (0x2E) 295 RTD #6 Temp RDG REAL 928/929 47 (0x2F) 296 RTD #7 Temp RDG REAL 930/931 48 (0x30) 297 RTD #8 Temp RDG REAL 932/933 49 (0x31) 298 RTD #1 Trip Cntr UINT 1164 50 (0x32) 299 RTD #2 Trip Cntr UINT 1165 51 (0x33) 300 RTD #3 Trip Cntr UINT 1166 52 (0x34) 301 RTD #4 Trip Cntr UINT 1167 53 (0x35) 302 RTD #5 Trip Cntr UINT 1168 54 (0x36) 303 RTD #6 Trip Cntr UINT 1169 55 (0x37) 304 RTD #7 Trip Cntr UINT 1170 56 (0x38) 305 RTD #8 Trip Cntr UINT 1171 Class 0x65, Instance 3 1 310 RTD #1 Type /Set 0, 0, 4 UINT 407 2 311 RTD #2 Type /Set 0, 0, 4 UINT 408 3 312 RTD #3 Type /Set 0, 0, 4 UINT 409 4 313 RTD #4 Type /Set 0, 0, 4 UINT 410 5 314 RTD #5 Type /Set 0, 0, 4 UINT 411 6 315 RTD #6 Type /Set 0, 0, 4 UINT 412 7 316 RTD #7 Type /Set 0, 0, 4 UINT 413 8 317 RTD #8 Type /Set 0, 0, 4 UINT 414 9 318 RTD #1 Function /Set 0, 0, 7 UINT 431 10 (0x0A) 319 RTD #2 Function /Set 0, 0, 7 UINT 432 11 (0x0B) 320 RTD #3 Function /Set 0, 0, 7 UINT 433 12 (0x0C) 321 RTD #4 Function /Set 0, 0, 7 UINT 434 13 (0x0D) 322 RTD #5 Function /Set 0, 0, 7 UINT 435 14 (0x0E) 323 RTD #6 Function /Set 0, 0, 7 UINT 436 15 (0x0F) 324 RTD #7 Function /Set 0, 0, 7 UINT 437 16 (0x10) 325 RTD #8 Function /Set 0, 0, 7 UINT 438 17 (0x11) 326 RTD #1 Trip Level /Set 130, 40, 200 REAL 510/511 18 (0x12) 327 RTD #1 Alarm Level /Set 110, 40, 200 REAL 512/513 19 (0x13) 328 RTD #2 Trip Level /Set 130, 40, 200 REAL 514/515 20 (0x14) 329 RTD #2 Alarm Level /Set 110, 40, 200 REAL 516/517 21 (0x15) 330 RTD #3 Trip Level /Set 130, 40, 200 REAL 518/519 22 (0x16) 331 RTD #3 Alarm Level /Set 110, 40, 200 REAL 520/521 23 (0x17) 332 RTD #4 Trip Level /Set 130, 40, 200 REAL 522/523 24 (0x18) 333 RTD #4 Alarm Level /Set 110, 40, 200 REAL 524/525 25 (0x19) 334 RTD #5 Trip Level /Set 130, 40, 200 REAL 526/527 26 (0x1A) 335 RTD #5 Alarm Level /Set 110, 40, 200 REAL 528/529

DeviceNet Interface Page 25 Class 0x65, Instance 3 (Continued) 27 (0x1B) 336 RTD #6 Trip Level /Set 130, 40, 200 REAL 530/531 28 (0x1C) 337 RTD #6 Alarm Level /Set 110, 40, 200 REAL 532/533 29 (0x1D) 338 RTD #7 Trip Level /Set 130, 40, 200 REAL 534/535 30 (0x1E) 339 RTD #7 Alarm Level /Set 110, 40, 200 REAL 536/537 31 (0x1F) 340 RTD #8 Trip Level /Set 130, 40, 200 REAL 538/539 32 (0x20) 341 RTD #8 Alarm Level /Set 110, 40, 200 REAL 540/541 33 (0x21) 342 RTD #1 Name /Set RTD M3 #1 SHORT_ 770 34 (0x22) 343 RTD #2 Name /Set RTD M3 #2 SHORT_ 780 35 (0x23) 344 RTD #3 Name /Set RTD M3 #3 SHORT_ 790 36 (0x24) 345 RTD #4Name /Set RTD M3 #4 SHORT_ 800 37 (0x25) 346 RTD #5 Name /Set RTD M3 #5 SHORT_ 810 38 (0x26) 347 RTD #6 Name /Set RTD M3 #6 SHORT_ 820 39 (0x27) 348 RTD #7 Name /Set RTD M3 #7 SHORT_ 830 40 (0x28) 349 RTD #8 Name /Set RTD M3 #8 SHORT_ 840 41 (0x29) 350 RTD #1 Temp RDG REAL 934/935 42 (0x2A) 351 RTD #2 Temp RDG REAL 936/937 43 (0x2B) 352 RTD #3 Temp RDG REAL 938/939 44 (0x2C) 353 RTD #4 Temp RDG REAL 940/941 45 (0x2D) 354 RTD #5 Temp RDG REAL 942/943 46 (0x2E) 355 RTD #6 Temp RDG REAL 944/945 47 (0x2F) 356 RTD #7 Temp RDG REAL 946/947 48 (0x30) 357 RTD #8 Temp RDG REAL 948/949 49 (0x31) 358 RTD #1 Trip Cntr UINT 1172 50 (0x32) 359 RTD #2 Trip Cntr UINT 1173 51 (0x33) 360 RTD #3 Trip Cntr UINT 1174 52 (0x34) 361 RTD #4 Trip Cntr UINT 1175 53 (0x35) 362 RTD #5 Trip Cntr UINT 1176 54 (0x36) 363 RTD #6 Trip Cntr UINT 1177 55 (0x37) 364 RTD #7 Trip Cntr UINT 1178 56 (0x38) 365 RTD #8 Trip Cntr UINT 1179

DeviceNet Interface Page 26 3.10 RTC CLASS 0x66 RTC Object Class Services _Attribute_Single: Returns contents of specified RTC Class 0x66, Instance 0 Attributes 1 Revision Revision of this object. 1 UINT 2 Max Instance Maximum number of instances. 1 UINT RTC Object Class Services _Attribute_Single: Returns contents of specified Set_Attribute_Single: Modifies specified RTC Class 0x66, Instance 1 Attributes 1 370 RTC Date Number of days since 1972-01-01. DATE 574 (1) 2 371 RTC Time Number of milliseconds since 00:00:00:00.000. TIME OF DAY 3 372 RTC Set /Set (1) String used to set the date and time SHORT_ YY/MM/DD-HH:MM:SS. Time value is also set with a SET RTC command issued using Class 0x29, Instance 1, Attribute 0x64. 576 580 3.11 USER-DEFINED CLASS 0x67 This object defines the registers that generate the data for Assembly Class 4, Instance 0x64, Attribute 3. Register values are defined in Appendix E of the Manual and also listed in the Register column in this manual. Enter the register number for the required parameter data. Parameter data is 16 bits and two registers must be defined to retrieve a 32-bit float value. For example, to configure an assembly to read the first four RTD temperatures in RTD Module 1, enter register numbers 902, 903, 904, 905, 906, 907, 908, 909. The first 16 bytes of the assembly will contain the RTD data and the remainder of the assembly will not contain any valid data. Register definitions resulting in more than 64 bytes of data will be ignored. User-Defined Register Object Class Services _Attribute_Single: Returns contents of specified User-Defined Register Class 0x67, Instance 0 Attributes 1 Revision Revision of this object. 1 UINT 2 Max Instance Maximum number of instances. 1 UINT