VB Model. Instruction Manual. Vibration Meter. reedinstruments. www. com

Similar documents
VIBRATION METER Model : VB-8213

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

DIGITAL ANEMOMETER Model : AM-4203

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

SD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

Heavy Duty Vibration Meter

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

PRESSURE METER OPERATION MANUAL. Model : PS-9302

Model LM-81LX. Instruction Manual. Light Meter. reedinstruments. REED Instruments

ANEMOMETER OPERATION MANUAL. metal vane + air flow. Model : AM-4206M

Model LM-81LX. Instruction Manual. Illuminometer. reedinstruments. www. com

SD Model. Instruction Manual. Heat Stress Meter and Datalogger. reedinstruments

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

Heavy Duty Vibration Meter

MANOMETER OPERATION MANUAL. 200 mbar, differential input. Model : PM-9102

AC/DC MAGNETIC METER

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

MANOMETER OPERATION MANUAL mbar, differential input. Model : PM-9107

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

UV LIGHT METER UVC-254

VACUUM METER Model : VC-9200

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322

12 channels TEMPERATURE RECORDER Model : BTM-4208SD

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

Torque Meter. Instruction Manual

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

SD Model. Instruction Manual. Sound Level Meter/ Data logger. reedinstruments. www. com

ANEMOMETER OPERATION MANUAL. Model : AM-4207SD. SD card real time datalogger + Type K/J thermometer

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

600 g x 0.02 g DIGITAL BALANCE

OPERATION MANUAL. SD card real time Data Recorder SOLAR POWER METER. Model : SPM-1116SD

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

Sound Level Meter SL-4035SD. Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

UVA LIGHT METER OPERATION MANUAL. Model : UVA-365SD. SD card real time datalogger + Type K/J thermometer

Pen Vibration Meter. User's Guide. Model VB Washington Street Melrose, MA Phone Toll Free

Light Meter with Bar Graph

SD Card real time data recorder + type K/J TEMP. CUP ANEMOMETER

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

MOISTURE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. 3, Hagavish st. Israel Tel: , Fax:

OPERATION MANUAL. SD card real time datalogger HUMIDITY/TEMP. MONITOR. Model : MHT-381SD

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS General Specifications Electrical Specifications...3

OPERATION MANUAL. ph/mv SD card real time data logger ph METER. Model : PH-230SD

OPERATION MANUAL. SD card real time datalogger 3 Channels TEMPERATURE DATA RECORDER. Model : MTM-380SD. Your purchase of this 3

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

SD card real time data logger TDS ( Total dissolved solids ), Salt '20 us/200 us/2 ms/20 ms/200 ms CONDUCTIVITY METER.

OPERATION MANUAL. SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER. Model : MMA-386SD

Vibration Meter and Laser Combination Tachometer

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

LIGHT METER OPERATION MANUAL. auto range 0 to 50,000 Lux, 3 ranges. Model : LX-113S

Therma-Stor LLC Model LM in-1 Pocket Thermo-Anemometer, Hygrometer, Thermometer & Illuminometer. Instruction Manual.

OPERATION MANUAL. SD card real time datalogger HEAT INDEX WBGT METER. Model : WBGT-2010SD

TORQUE WRENCH OPERATION MANUAL. Model : TQ Kgf-cm, heavy duty, professional

LIGHT METER. Model : LM-81LX. Digital Measurement Metrology, Inc Digital Measurement Metrology, Inc

User's Guide. Vibration Meter and Laser Combination Tachometer Model

4 in 1 Anemometer, Humidity Light Meter, Thermometer

Clamp meter with Data recorder SERIES set

Anemometer, Hygrometer Light Meter, Thermometer

OPERATION MANUAL. SD card real time data logger DISSOLVED OXYGEN METER. Model : DO-5512SD

LIGHT METER OPERATION MANUAL. Model : LM-81LX

MMD7003 USER S MANUAL. DIGITAL and LED PRECISION MOISTURE METER

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

4-Channel Vibration Datalogger

TORQUE METER Model : TQ-8800

SD card real time datalogger, RS232/USB Frequency weighting and Time weighting meet IEC class 2, Personal sound exposure meet IEC 61252

Manual Digital Thermometer PCE-T 390

USER`S MANUAL Professional measuring instrument 4 in 1 ATE-9508

SOIL MOISTURE METER OPERATION MANUAL. Model : DSMM500. Your purchase of this

VANE ANEMOMETER HUMIDITY/TEMP.

Pocket type SOUND LEVEL METER Model : SL-4030

USER GUIDE. AC/DC Magnetic Meter. Model MF100

Vibration Meter SD Card real-time datalogger

DATALOGGER. SD card, real time OPERATION MANUAL. Model : DL-9602SD

TU-2016 TURBIDITY METER

Torque Meter. Instruction Manual

Model Instruction Manual. Digital Pocket Psychrometer. reedinstruments. www. com

HOT WIRE ANEMOMETER. Model : 204HA

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

Model Instruction Manual. Heat Stress Meter. reedinstruments. www. com

Datalogging Hot Wire CFM Anemometer

RH/Temperature SD Card Datalogger. Instruction Manual

Heavy Duty Mini Vane CFM Thermo Anemometer

Wide Range Pressure Meter Instruction Manual

INSTRUCTION MANUAL. Models: H100 Light Meter

Mini Environmental Quality Meter

Model R8050. Instruction Manual. Sound Level Meter. reedinstruments. REED Instruments

Anemometer SD Card Datalogger. Instruction Manual

Laser, PHOTO TACHOMETER RS

VANE ANEMOMETER BAROMETER HUMIDITY/TEMP. Model : ABH-4225

Heavy Duty Differential Pressure Manometer. Model User's Guide

User's Guide. Hot Wire Thermo-Anemometer. Model

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

Transcription:

Model Vibration Meter Instruction Manual VB-8200 reedinstruments com

Table of Contents Features... 3 Specifications...4-5 Instrument Description... 6 Operating Instructions...5-10 PEAK value... 6 Data Hold... 6 Data Record (Max & Min reading)... 7 Zero Adjustment... 7 Auto Power Off... 7 RS232 PC Serial Interface... 8 Classification Ranges... 9 Relative sensitivity... 10 Battery Replacement... 10 For service on this or any other REED product or information on other REED products, contact REED Instruments at info@reedinstruments.com reedinstruments com 2

Features Frequency range 10 Hz - 1 khz, meets ISO 2954 standards Velocity measuring range 200 mm/s Acceleration measuring range 200 m/s 2 RMS & Peak measurement Wide frequency range.... Data hold button to freeze the desired reading Memory function to record maximum and minimum reading. with recall RS232 or USB output Optional data acquisition software for data record & datalogger Easy-to-read 4-digit LCD readout Microcomputer circuit, high performance Auto shut off saves battery life Built-in low battery indicator Heavy duty & compact housing case Specifications Measurement: Velocity, Acceleration RMS value, Peak value,. Data hold, Max & Min value Velocity Range: 0.5 to 199.9mm/s Acceleration Range: 0.5 to 199.9m/s 2 Frequency range: 10Hz to 1KHz Accuracy: ±(5% + 2d) 160Hz, 80Hz @ 23 ± 5 C Calibration point: Velocity: 50mm/s (160Hz). Acceleration: 50m/s 2 ( 160Hz ) Circuit: Exclusive microcomputer circuit Sampling time: Approx. 1 second Data output: RS232 or USB continued... reedinstruments com 3

Operating temp.: Operating humidity: Display: 0 C to 50 C (32 F to 122 F) Less than 80% RH 61mm x 34mm LCD display 15mm (0.6 ) digits Power supply: Alkaline or heavy duty type, DC 9V battery,. 006P, MN 1604 (PP3) or equivalent. Power consumption: Approx. DC 6mA Dimensions: Meter: 180 x 72 x 32mm (7.1 x 2.8 x 1.3 ). Vibration sensor probe: 19mm Dia. x 21 mm Weight: Meter: 230g/0.50lb. Probe with magnetic base: 38g/0.09lb Includes: Remote vibration sensor, hard carrying case and. battery Optional accessories: Data Acquisition Software (Model SW-U801-WIN). RS232 Cable (Model UPCB-01). USB Cable (Model USB-01) For service on this or any other REED product or information on other REED products, contact REED Instruments at info@reedinstruments.com reedinstruments com 4

Instrument Description 1.. Display 2.. BNC.socket 3.. RS232.output.terminal 4.. RMS/PEAK.switch 5.. Acceleration/Velocity.switchch 6.. Data.hold.button 7.. Power.button 8.. RECORD.button 9.. RECALL.button 10..Battery.compartment/cover 11..BNC.plug 12..Mini.plug 13..Vibration.sensor.input.socket 14..Vibration.sensor 15..Magnetic.base Operating Instructions 1.. Plug.in.the.BNC.plug.to.the.BNC.socket 2.. Plug.in.the.Mini.plug.to.the.Vibration.sensor.input.socket 3.. For.acceleration.measurements,.put.the.Acceleration/Velocity. switch.to.the.acc.position 4.. For.velocity.measurements,.put.the.Acceleration/Velocity.switch. to.the.vel.position..for.general.applications.of.industrial.vibration. monitoring,.select.velocity.measurement 5.. Put.the.RMS/PEAK.switch.to.the.RMS.position 6.. Turn.the.meter.on.by.pushing.the.Power.Button 7.. If.the.surface.material.of.the.item.being.measured.is.not.ferrous,. hold.the.vibration.sensor.by.hand.&.touch.the.sensor.to.the.surface. of.the.item,.refer.the.fig..2 continued... reedinstruments com 5

Fig 2 Fig 3 Fig 4 8. If the surface material of the item being measured is ferrous,. connect the Vibration sensor with the Magnetic base (see Fig 3). Put the whole unit (Vibration sensor & Magnetic base) on the surface of the item being measured (refer to Fig. 4). Peak value Before measuring, put the RMS/PEAK switch to the PEAK position.. During measurement, the display will show the peak value.. Peak value = 1.414 RMS value Data Hold While measuring, press the Data Hold button and the current value will be held the LCD screen along with a DH symbol. Push the Data hold button again to release the data hold function. reedinstruments com 6

Data Record (Max & Min reading) The Data Record function displays the maximum, minimum and average readings. To start the Data Record function, press the RECORD button.. A REC symbol will appear on the LCD display. 1. Push the RECALL button once and a Max symbol along with the maximum value will appear on the display 2. Push the RECALL button again, and a Min. symbol along with the minimum value will appear on the display. 3. To exit the memory record function, push the RECORD button once again. The display will revert back to the current reading Zero Adjustment Change in environment temperatures, battery power change, using the meter for an extended period of time, or other reasons could result in the display value to not be accurate. This will not dramatically affect the measurement readings, however if high precision is required, the following zero adjustment procedures should be executed: 1. Put the Acceleration/Velocity. Switch to the Acceleration position 2. Be sure there is no signal to the. vibration sensor 3. Open the battery cover 4. Use a screw driver to adjust. Zero adjust VR until the display. reaches a value of zero Auto Power Off As a default the instrument will be set to automatically turn itself off after 10 minutes of not being used. reedinstruments com 7

RS232 PC Serial Interface The instrument features an RS232 output via 3.5 mm terminal. The connector output is a 16 digit data stream which can be utilized to the user s specific application. An RS232 lead with the following connection will be required to link the instrument with the PC serial input. Meter (3.5mm Jack Plug) PC (9W D Connector) Center Pin Pin 2 Ground/Shield Pin 5 The 16 digit data stream will be displayed in the following format: D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 D0 D1 to D4 D5 to D8 D9 End Word Upper Display reading, D1= LSD, D4= MSB D5=? D6=? D7=? D8=? Decimal Point ( DP) for display. 0 = No DP, 1 = 1 DP, 2 = 2 DP, 3 = 3 DP D10 D10 = 0 D11 D11 = 0 D12 D12 = 0 D13 D13 = 0 D14 D14 = 0 D15 Start Word RS232 FORMAT : 9600, N, 8, 1 ** Also compatible for USB output reedinstruments com 8

Classification Ranges For the evaluation of machines and equipment in ISO 2372 and VDI 2056, four different kinds of machine groups with four classification ranges and their limits for vibration severity (mm/s) are determined. The classifications for each machine group are specified as follows: Small machines, production electrical motors of up to 15KW (Group K) Good 0 to 0.71 mm/s Acceptable 0.72 to 1.80 mm/s Still permissible 1.81 to 4.5 mm/s Dangerous >4.5 mm/s Medium sized machines, electrical motors with 15 up to 75 KW output, without special foundations (Group M) Good 0 to 1.12 mm/s Acceptable 1.13 to 2.80 mm/s Still permissible 2.81 to 7.1 mm/s Dangerous >7.1 mm/s Large machines on heavy foundations (Group G) Good 0 to 1.80 mm/s Acceptable 1.81 to 4.50 mm/s Still permissible 4.51 to 11.2 mm/s Dangerous >11.2 mm/s Largest machines and turbo machines with a special foundation (Group T) Good 0 to 2.80 mm/s Acceptable 2.81 to 7.10 mm/s Still permissible 7.11 to 18.0 mm/s Dangerous >18 mm/s reedinstruments com 9

Relative sensitivity To the reference sensitivity at 80Hz, according ISO 2954 Frequency Hz Normal Value Minimum Value Maximum value 10 hz 1.0 0.8 1.1 20 hz 1.0 0.9 1.1 40 hz 1.0 0.9 1.1 80 hz 1.0 1.0 1.0 160 hz 1.0 0.9 1.1 500 hz 1.0 0.9 1.1 1000 hz 1.0 0.8 1.1 Battery Replacement When the left corner of LCD displays a LBT symbol, it is necessary to replace the battery. 1. Use a screw driver to open the Battery Cover & remove the battery 2. Install a 9V battery (Alkaline or heavy duty) and replace the cover Note: Measurements can still be made for several hours after the low. battery indicator appears before the reading becomes inaccurate............ For service on this or any other REED product or information on other REED products, contact REED Instruments at info@reedinstruments.com reedinstruments com 10