XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm

Similar documents
XUSL4E30H151N XUSL type 4 - For hand protection - Std sensing range - Hp = 1510 mm, R=30mm

XUSL4E2BB051L XUSL type 4 - Body protection - Long sensing range 510 mm

XUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm

XUSL2E30H166N XUSL type 2 Hand protection - Std sensing range - Hp = 1660mm, R=30mm

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing

XGCS491B201 Standalone panel smart antenna

XPSMCMDO Digital output pairs expansion modules with screw term

XPSMCMMX inputs 2 output pairs expansion module with screw term

XPSMCMDI Input expansion module with screw term

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

TM3SAF. Main. Device short name

RM35LM33MW liquid level control relay RM35-L V AC/DC

XGCS RFID compact smart antenna MHz - flat form 40x40x15 - M12 - cable 0.2m

TM3SAK. Main. Device short name

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

XUX9ARCNT16 photo-electric sensor - XUX - polarised - Sn 11m VAC/DC - terminals

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

TM3DI16G module TM3-16 inputs spring

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

ILS1M851PB1F0 integrated drive ILS with stepper motor V - I/O for motion sequence - 5A

XCMD21F0L2 limit switch XCMD - M12 metal end plunger - 1NC+1NO - snap - 2 m

XGCS850C201 RFID compact smart antenna MHz- Ethernet dual port communication

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

XXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

RM4TA32 three-phase network control relay RM4-T - range V

TM241CE24T controller M IO transistor PNP Ethernet

HMIPPH7A0701 Panel PC Performance - Hard Disk - 15'' - AC - 0 slot - fan

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

TM3DI16 module TM3-16 inputs

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM4TR31 three-phase network control relay RM4-T - range V

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RM35TF V AC

XBTGC2330T 5 7 LCD TFT color controller panel - 16 inputs/16 outputs source

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

XCKP2110N12 limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

RM35LM33MW liquid level control relay RM35-L V AC/DC

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE9RA21MW7 off-delay timing relay s V AC -

TM241CE40R controller M IO relay Ethernet

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

XCMN2102L2 limit switch XCMN - steel roller plunger - 1NC +1NO - snap - 2 m

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

HMIGTO5310 advanced touchscreen panel 640 x 480 pixels VGA- 10.4" TFT - 96 MB

XCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

SAFETY & MESUREMENT SFIN A GER F OT T PR E. TION light CURTAINS EC Y SG4-FINGER SERIES. highlights

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

140ERT85420 multifunction input module Modicon Quantum - 32 I - IRIG-B - DCF77

TM3AI4 module TM3-4 analog inputs

RMCN22BD Analog Converter ma - for Zelio Analog

RM4LA32M liquid level control relay RM4-L V AC

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

LMC058LF42 compact base - 42 I/O - 24 V DC supply

Transcription:

Characteristics XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm Complementary Detection system Response time Kit composition [EAA] effective aperture angle Emission Main Range of product Product or component type Device short name Output type Product specific application [R] Resolution [Sn] nominal sensing distance [Hp] Height protected Preventa Safety detection Safety light curtain type 4 XUSL4E 2 safety outputs OSSD solid-state PNP (integrated arc suppression) For finger protection 14 mm Number of beams 120 Type of start / restart External Device Monitoring (EDM) Transmitter-receiver system 16.5 ms 0...3 m by cabling 1...6 m by cabling 1210 mm Automatic Manual Selected by wiring 1 user guide with certificate of conformity on CD-ROM 1 transmitter(s) 1 receiver(s) Adjustable mounting bracket(s) +/- 2.5 at 3 m IR LED (λ = 950 nm) [Us] rated supply voltage 24 V DC (+/- 20 %) Supply Power supply must meet requirements of IEC 60204-1 Power supply must meet requirements of IEC 61496-1 [Ie] rated operational current Current consumption Output current limits Output voltage Output circuit type Voltage drop Local signalling Electrical connection Function available Marking Material Housing colour 2 A 900 ma with maximum load (receiver) 42 ma (transmitter) 83 ma no-load (receiver) 42 ma no-load (transmitter) 0.4 A for safety outputs OSSD 24 V DC <= 0.5 V 2 dual colour LEDs (receiver) 1 multi-colour LED (transmitter) 1 male connector M12 8 pins (receiver) 1 male connector M12 5 pins (transmitter) LED display of operating modes and faults Muting through external safety module XPSLCMUT1160 Test CE End caps : polypropylene Front panel : polycarbonate Casing : aluminium RAL 3000 : red The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Apr 29, 2015 1

Fixing mode Product weight Offer type By fixing brackets 2.3 kg Standard distance Environment Directives Product certifications 89/336/EEC - electromagnetic compatibility 2002/96/EC - WEEE directive 2002/95/EC - RoHS directive 98/37/EEC - machinery 89/655/EEC - work equipment CE CULus TÜV Safety level (correctly wired) PL = e conforming to EN/ISO 13849-1 Category 4 conforming to EN/ISO 13849-1 SILCL 3 conforming to IEC 62061 SIL 3 conforming to IEC 61508 Type 4 conforming to IEC 61496-1 Optical characteristic Resistance to light disturbance conforming to EN/IEC 61496-2 Mission time Safety reliability data PFHd = 2.73E-8 1/h conforming to IEC 61508 20 yr Ambient air temperature for operation -10...55 C 14...131 F Ambient air temperature for storage -25...70 C -13...158 F Relative humidity IP degree of protection <= 95 % without condensation IP67 IP65 Shock resistance 10 gn for 16 ms conforming to IEC 61496-1 Vibration resistance 0.35 +/- 0.05 mm (f = 10...55 Hz) conforming to IEC 61496-1 Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1425 - Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product environmental profile Available Download Product Environmental Product end of life instructions Available Download End Of Life Manual 2

Dimensions Drawings Dimensions Brackets Dimensions 3

Mounting and Clearance Mounting and Clearance (1) Insert (2) Bracket (3) Washer (4) Spring washer (5) Nut 4

Connections and Schema Wiring Diagrams Transmitter Connections (1) +24 Vdc (2) Configuration_0 (3) 0 Vdc (4) Configuration_1 (5) FE Transmitter configurations and operating modes High range option Low range option Transmitter in Test state Forbidden wiring Pin 4 : Configuration_1 24 V 0 V 0 V 24 V Pin 2 : Configuration_0 0 V 24 V 0 V 24 V Receiver Connections (1) OSSD1 (2) + 24 V (3) OSSD2 (4) Configuration_A (5) K1_K2 Feeback/Restart (6) Configuration_B (7) 0 Vdc (8) FE Receiver Configurations and Operating Modes Automatic Start/Restart Without External Device Monitoring (EDM) feedback loop 5

With External Device Monitoring (EDM) feedback loop Manual Start/Restart Without External Device Monitoring (EDM) feedback loop (1) Restart With External Device Monitoring (EDM) feedback loop (1) Restart Connection Schematics Standalone Application XUSL4E light curtains are conforming to Type 4 (IEC 61496-1), SIL3 (IEC 61508) - SILCL3 (IEC 62061) and PLd- Cat.4 (EN ISO 13849-1:2008) 6

Example of wiring diagram with manual start, external device monitoring and low range (1) Power supply (2) XUSL Receiver (3) XUSL transmitter (4) Low range (5) Start The contactors K1/K2 must have : * Normally closed mirror contact, according to IEC 60947-4-1 for power contactors * Linked contacts (or force guided contacts), according to IEC 60947-5-1 or EN 50205 for auxiliary contactors or control relays 7