XUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm

Similar documents
XUSL2E30H166N XUSL type 2 Hand protection - Std sensing range - Hp = 1660mm, R=30mm

XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm

XUSL4E30H151N XUSL type 4 - For hand protection - Std sensing range - Hp = 1510 mm, R=30mm

XUSL4E2BB051L XUSL type 4 - Body protection - Long sensing range 510 mm

XPSMCMDO Digital output pairs expansion modules with screw term

XPSMCMMX inputs 2 output pairs expansion module with screw term

XPSMCMDI Input expansion module with screw term

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35TF V AC

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

XGCS491B201 Standalone panel smart antenna

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

TM3DI16 module TM3-16 inputs

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

XB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center

TM3TI8T module TM3-8 inputs temperature

BMXAMI0410 analog input module M340-4 inputs - high speed

RM17UB3. Price* : USD

TSXCTY2A 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC

TM3AI4 module TM3-4 analog inputs

TM3SAF. Main. Device short name

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

TM3TI4 module TM3-4 inputs temperature

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

SAFETY & MESUREMENT SFIN A GER F OT T PR E. TION light CURTAINS EC Y SG4-FINGER SERIES. highlights

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

TM3SAK. Main. Device short name

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

TM3TM3 module TM3-2 temperature inputs and 1 analog output

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

TM241C24T controller M IO transistor PNP

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

TM241C40U controller M IO transistor NPN

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

XGCS RFID compact smart antenna MHz - flat form 40x40x15 - M12 - cable 0.2m

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ASI SAFETY & MESUREMENT. SG4-FINGER SERIES. APPlICATIONS

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

ILS1M851PB1F0 integrated drive ILS with stepper motor V - I/O for motion sequence - 5A

TM258LF42DT compact base M I/O - 24 V DC - CANopen

BMEP processor module M580 - Level 1 - Distributed

LMC058LF42 compact base - 42 I/O - 24 V DC supply

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

XUX9ARCNT16 photo-electric sensor - XUX - polarised - Sn 11m VAC/DC - terminals

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

TM258LD42DT4L compact base M I/O - 24 V DC

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

HAND PROTECTION APPLICATIONS

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

XCMD2110L1 limit switch XCMD - metal end plunger - 1NC +1NO - snap - 1 m

TM241C40R controller M IO relay

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

TM251MESC controller M251 Ethernet CAN

TM3DM8R module TM3-8 IO relays

TM3DI8A module TM3-8 inputs 120V AC

RXM4AB1MD Miniature Plug-in relay - Zelio RXM 4 C/O 220 V DC 6 A

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

TM200C24R controller M IO relay

TM241CE40T controller M IO transistor PNP Ethernet

BMXCPS3020H power supply module X V isolated DC -

TM221M16TG controller M IO transistor PNP spring

XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ZB5FG09 flush mounted selector switch head key pos stay put

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

Transcription:

Characteristics XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm Main Range of product Nov 18, 2017 Preventa Safety detection Product or component type Safety light curtain type 4 Device short name Output type Product specific application Minimum object diameter for detection [Sn] nominal sensing distance Height protected Number of beams 45 Type of start Control type Complementary Detection system Response time Kit composition [EAA] effective aperture angle Emission XUSL4E 2 safety outputs OSSD solid-state PNP (integrated arc suppression) For finger protection 14 mm 1...6 m by cabling 0...3 m by cabling 460 mm Manual Automatic Selected by wiring Transmitter-receiver system 7.5 ms Adjustable mounting bracket(s) 1 receiver(s) 1 transmitter(s) 1 user guide with certificate of conformity on CD-ROM +/- 2.5 at 3 m IR LED (λ = 950 nm) [Us] rated supply voltage 24 V DC (+/- 20 %) Supply Power supply must meet requirements of IEC 61496-1 Power supply must meet requirements of IEC 60204-1 [Ie] rated operational current Current consumption 2 A 42 ma no-load (transmitter) 83 ma no-load (receiver) 42 ma (transmitter) 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Output current limits Output voltage Output circuit type Voltage drop Local signalling Electrical connection Function available Marking Material Housing colour Fixing mode Product weight Offer type 900 ma with maximum load (receiver) 0.4 A for safety outputs OSSD 24 V DC <= 0.5 V 1 multi-colour LED (transmitter) 2 dual colour LEDs (receiver) 1 male connector M12 5 pins (transmitter) 1 male connector M12 8 pins (receiver) Muting through external safety module XPSLCMUT1160 LED display of operating modes and faults Test CE Front panel : polycarbonate End caps : polypropylene Casing : aluminium RAL 3000 : red By fixing brackets 1 kg Standard distance Environment Directives Product certifications 2002/95/EC - RoHS directive 2002/96/EC - WEEE directive 89/655/EEC - work equipment 98/37/EEC - machinery 89/336/EEC - electromagnetic compatibility CE TÜV culus Safety level SIL 3 conforming to IEC 61508 Type 4 conforming to IEC 61496-1 SILCL 3 conforming to IEC 62061 Category 4 conforming to EN/ISO 13849-1 PL = e conforming to EN/ISO 13849-1 Environmental characteristic Resistance to light disturbance conforming to EN/IEC 61496-2 Service life 20 yr Safety reliability data PFHd = 1.52E-8 1/h conforming to IEC 61508 Ambient air temperature for operation -20...55 C 14...131 F Ambient air temperature for storage -35...70 C -13...158 F Relative humidity IP degree of protection 0...95 % without condensation IP65 IP67 Shock resistance 10 gn for 16 ms conforming to IEC 61496-1 Vibration resistance 0.35 +/- 0.05 mm (f = 10...55 Hz) conforming to IEC 61496-1 Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Green Premium product Compliant - since 1425 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Available Product environmental Available End of life manual 2

Contractual warranty Warranty period 18 months 3

Dimensions Drawings Dimensions 4

Dimensions Drawings Brackets Dimensions 5

Mounting and Clearance Mounting and Clearance (1) Insert (2) Bracket (3) Washer (4) Spring washer (5) Nut 6

Connections and Schema Wiring Diagrams Transmitter Connections (1) +24 Vdc (2) Configuration_0 (3) 0 Vdc (4) Configuration_1 (5) FE Transmitter configurations and operating modes High range option Low range option Transmitter in Test state Forbidden wiring Pin 4 : Configuration_1 24 V 0 V 0 V 24 V Pin 2 : Configuration_0 0 V 24 V 0 V 24 V Receiver Connections (1) OSSD1 (2) + 24 V (3) OSSD2 (4) Configuration_A (5) K1_K2 Feeback/Restart (6) Configuration_B (7) 0 Vdc (8) FE 7

Connections and Schema Receiver Configurations and Operating Modes Automatic Start/Restart Without External Device Monitoring (EDM) feedback loop With External Device Monitoring (EDM) feedback loop Manual Start/Restart Without External Device Monitoring (EDM) feedback loop (1) Restart 8

With External Device Monitoring (EDM) feedback loop (1) Restart 9

Connections and Schema Connection Schematics Standalone Application XUSL4E light curtains are conforming to Type 4 (IEC 61496-1), SIL3 (IEC 61508) - SILCL3 (IEC 62061) and PLd- Cat.4 (EN ISO 13849-1:2008) Example of wiring diagram with manual start, external device monitoring and low range (1) Power supply (2) XUSL Receiver (3) XUSL transmitter (4) Low range (5) Start The contactors K1/K2 must have : * Normally closed mirror contact, according to IEC 60947-4-1 for power contactors * Linked contacts (or force guided contacts), according to IEC 60947-5-1 or EN 50205 for auxiliary contactors or control relays 10