Copyright Black Box Corporation. All rights reserved.

Similar documents
Miniature Asynchronous 4-Wire High Speed Modems

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

The Tri-State Box User s Manual

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.

Multi-Channel RS-232 Current Loop Interface Converter (CLIC)

RS-232/RS-422 Optical Isolator

Relay Tool CUSTOMER SUPPORT INFORMATION MARCH 1997 LT037

RS-422 Code-Operated Switches

ISOLATED RS-232 TO RS-422/485 CONVERTER

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.

Copyright Black Box Corporation. All rights reserved.

INSTALLATION and OPERATION MANUAL

Enhanced Mini-Chansim Model VCS-232

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

Select a Data Communication Interface

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

Miniature Asynchronous Modems

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

Sender Receiver Sender

Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m

SyncLink GT Serial Adapter

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL

Storage/Control I/O Module

DB9 Microdriver CUSTOMER SUPPORT INFORMATION JULY 1994 ME792A ME793A ME794A

SyncLink GT2E/GT4E Serial Adapter

SC32A Optically Isolated RS232 Interface

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 DB-9 DB-25 CONVERSION TABLE. 2 DRIVER INSTALLATION QUICK GUIDE.. 2

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.

RS-232 SERIAL INTERFACE PHOTOELECTRIC ISOLATOR

Manual Swipe Magnetic Card Reader

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

The Wireless Connectivity Expert

Tone Generator and Probe

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651)

SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL

ANC Series RS-422 Serial Communications Adapter

RS-232 is a complete standard. This means that the standard sets out to ensure compatibility between the host and peripheral systems by specifying:

Serial Interfaces Part 1. ECE 153B Sensor & Peripheral Interface Design Winter 2016

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

Appendix A Cable Pinouts

Chapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer

Appendix C. Datum Systems PSM-4900 Satellite Modem. Cabling Specifications

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.

Starter Guide Version Sphinx Access Control System

Cabling Guide for Console and AUX

ME758C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: DB25 RJ45 CONN. INTERFACE MODULE (REAR CARD)

HS-RN. 4-Channel Low Speed Data Module with End-to-End Signaling OPERATION MANUAL INSTALLATION AND

Cable Pinouts. SRP I/O Module

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

RocketPort Plus Hardware Installation

Connector and Cable Specifications

SeaLINK+232I USER MANUALM

User Guide. Date Apr BlueEva+C11/G2. Stollmann. E + V GmbH. User Guide

SyncLink GT4 PC/104+ Serial Adapter

SyncLink USB Serial Adapter

Table 8 shows the pin configuration and function of a standard computer-to-printer parallel cable. Table 8 Parallel Cable Pin Configuration

PCL Port RS-232 Interface Card

Overview. Port Adapter Overview CHAPTER

Advanced Electronic Communications Systems Wayne Tomasi Sixth Edition

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

E1/T1 Rate Converters

ICP PANEL-TEC PEX3000 II

USB RS232 Communication adapter virtual serial port ELO E215. Operation manual

RS-232 to Logic Level Adapter with DB9M Connector and Power LED

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

Four Port RS-232 Serial Interface

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

ELAN DIGITAL SYSTEMS LTD. CF232 COMPACT FLASH CF+ CARD USER S GUIDE

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION

NOTE: The numbers in the wiring diagrams do not show the order of connection. Follow the written instructions to make the connections.

EXTENDER 6000 / 7000 CABLES & CONNECTORS

Practical Hands-on Data Communications, Networking and TCP/IP Troubleshooting for Engineers and Technicians

Quick Start Guide. Remote Console Manager Quick Start Guide

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM

Powered RS Port PCIe Card

IC232 PC- CARD USER S GUIDE

ELAN DIGITAL SYSTEMS LTD.

SitePORTAL Lite TA-SPL32-R48

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

SC532 9-Pin Peripheral to RS232 Interface

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

NetBiter Serial Server User Manual

3.1 I-7560 Pin Assignment and Specifications: Introduction

G.SHDSL NTU with Fixed Serial Interfaces

DATA CONNECT ENTERPRISE

Black Box Tech Support: FREE! Live. 24/7.

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

RS-232 Driver Module

4.3 Digital Communication

Product Overview. Interface Converters and Plug-in Modules

Model:UT-8814 USB/RS-232 Commercial interface converter. Instruction Manual

Table of Contents SPECIFICATIONS...4 THEORY OF OPERATION...9 DIP SWITCH SETTING TABLES:...12 WAN PORT PIN ASSIGNMENT...15 CABLE PIN ASSIGNMENTS:...

Industrial Isolated Converters

RS-232 Industrial Media Converter

Dual Port RS-232 Serial Interface

Bluetooth TO Serial CONVERTER E-P132-B

USART. USART stands for Universal Synchronous Asynchronous Receiver Transmitter. Full-duplex NRZ asynchronous serial data transmission

Transcription:

Copyright 1998. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 150551018 7247465500 Fax 7247460746

SAM232 Compact MARCH 1998 TS158A DB 9P cable test 1 5 6 8 7 2 3 9 4 7 6 5 4 3 2 1 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 +V V ON OFF 14 13 12 11 10 9 8 7 6 5 4 3 2 1 CL 25 24 23 22 21 20 19 18 17 16 15 +V V Com. 4 10 20 60mA TI TC DRS CI RL DTR RTS.2 LL RC RD.2 TC TD.2 CTS.2 DCD.2 STF V +V DCD S.GND DSR CTS RTS RD TD F.GND CUSTOMER SUPPORT INFORMATION Order tollfree in the U.S.: Call 877877BBOX (outside U.S. call 7247465500) FREE technical support 24 hours a day, 7 days a week: Call 7247465500 or fax 7247460746 Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 150551018 Web site: www.blackbox.com Email: info@blackbox.com

SAM232 COMPACT TRADEMARKS The trademarks mentioned in this manual are the sole property of their owners. 3

SAM232 COMPACT CONTENTS 1. Specifications............................... 5 2. Introduction............................... 6 2.1 General................................ 6 2.2 Functional Description.................... 8 2.2.1 Interface Connectors.................. 8 2.2.2 Signal Status Display.................. 8 2.2.3 Breakout Switches.................... 9 2.2.4 Access Sockets....................... 9 2.2.5 Jumper Cables/Patching.............. 9 2.2.6 Ground Potential Difference Test....... 10 2.2.7 Power/Test Voltage Sources............ 10 2.2.8 Current Loop Test Circuit............. 10 3. Instructions for Use......................... 12 3.1 Introduction............................ 12 3.2 Breakout Box Functions/Patching.......... 12 3.3 Monitoring the Interface Signals........... 14 3.4 ControlSignal Simulation................. 15 3.5 Ground Potential Difference Test.......... 15 3.6 Current Loop Circuit Examination......... 16 3.7 Cable Testing........................... 18 4

1. Specifications Number of Breakout Switches 25 Number of Probe Points 50 Display 102 LEDs SAM232 COMPACT Temperature Operating: 32 to 122 F (0 to 50 C); Storage: 13 to 158 F (25 to 70 C) Size 3.4 H x 7.4 W x 0.7 D (8.5 x 18.8 x 2.3 cm) Weight 8.9 oz. (280 g) 5

SAM232 COMPACT 2.1 General 2. Introduction The SAM232 Compact is the basic tool for testing and troubleshooting interfaces meeting CCITT V.24 specifications or the equivalent EIA standard RS232C. It s used for easy installation and to verify the proper operation of RS232, the most widely accepted interface between computers, peripherals, modems, etc. Pocketsize, simple, and friendly, it s ideal for all users of data communications devices, as well as for specialists who install, repair, or sell RS232 (V.24) devices. The SAM232 Compact s features include a clear and logical layout of the faceplate, full fourstate linemonitoring capability, convenient cabletest function, and a unique Ground Potential Difference Current Loop test. 6

SAM232 COMPACT * Red LED voltage positive signal space ctrl ON * Green LED voltage negative signal mark ctrl OFF * Ground Potential Difference test: Open (OFF) all switches, connect both DTE & DCE. GPD exceeding 2 volts lights one of the Red LEDs #7 * Cable Test: Connect one lead of the battery to the upper left socket (#26). Run the other lead of battery through both right and left #125. Green LED #7 shows battery status, Red LED #7 lights when Signal GND connection in cable is broken. CCITT 101 102 103 104 105 106 107 108.1 108.2 109 111 113 114 115 118 119 120 121 122 125 140 141 142...... EIA AA AB BA BB CA CB CC CD CD CF CH DA DB DD SBA SBB SCA SCB SCF CE............... PIN 1 7 2 3 4 5 6 20 20 8 23 24 15 17 14 16 19 13 12 22 21 18 25 9 10 DESCRIPTION FRAME GROUND SIGNAL GROUND TRANSMITTED DATA RECEIVED DATA REQUEST TO SEND CLEAR TO SEND DATA SET READY CONNECT DATA SET TO LINE DATA TERMINAL READY DATA CARRIER DETECT DATA RATE SELECT TRANSMITTER CLOCK TRANSMITTER CLOCK RECEIVER CLOCK TRANSMITTED DATA CH 2 RECEIVED DATA CH 2 REQUEST TO SEND CH 2 CLEAR TO SEND CH 2 DATA CARRIER DETECT CH 2 CALLING INDICATOR REMOTE LOOPBACK LOCAL LOOPBACK TEST INDICATOR POSITIVE TEST VOLTAGE NEGATIVE TEST VOLTAGE DTEDCE...... Figure 21. Front View of the SAM232 Compact. 7

SAM232 COMPACT 2.2 Functional Description 2.2.1 INTERFACE CONNECTORS The SAM232 Compact has one female DB25 connector fixed on the lefthand side plus one male DB25 connector fixed on the righthand side, so you don t need adapters to join the cables to the tester. 2.2.2 SIGNAL STATUS DISPLAY The SAM232 Compact has inline monitors showing all interface lines at both sides of the breakout switches. Each monitor circuit uses two LEDs to indicate the state of the signal (MARK/SPACE/CLOCKING/ NONE) defined by the value of the line voltage V s with respect to signal ground (lead #7 in RS232/V.24 standard). The red LED indicates the SPACE/ON state of the signal; that is, V +3V. The green LED indicates MARK/OFF state, that is, V 3V. In both cases the brightness of the LED corresponds to the voltage value. For clock or data signals, both LEDs will light. If the signal voltage is in the transition region, that is, between 3V and +3V, neither LED will light. 8

SAM232 COMPACT 2.2.3 BREAKOUT SWITCHES Each of the 25 interface lines has an individual switch for breaking the circuit and network reconfiguration. The switches are located in the center part of the main control panel. 2.2.4 ACCESS SOCKETS On both sides of the breakout switches are sockets that allow direct access to both interfaces for crosspatching of lines via jumper cables. Access sockets also let you attach external monitoring instruments to any line. 2.2.5 JUMPER CABLES/PATCHING A set of jumper cables with highquality plugs is provided to allow crosspatching of interface lines. For multipleline connections, two sets of fourplug jumper cables are supplied with the unit. 9

SAM232 COMPACT 2.2.6 GROUND POTENTIAL DIFFERENCE TEST CIRCUIT The difference in ground potentials of the two interfaced devices can cause problems with signal interpretation. The circuit testing this difference uses the G.P.D. monitor connected to the left side of switch #7. For more detailed information, see Section 3.5. 2.2.7 POWER/TEST VOLTAGE SOURCES The basic functions of the SAM232 Compact do not require battery power. 2.2.8 CURRENT LOOP TEST CIRCUIT You can access the current loop (C.L.) test circuit via 5 sockets in the horizontal row above breakout switch #25. The common socket at the beginning of the row forms a common input, while the right sockets marked 4, 10, 20, 60mA become the second input. One of two C.L. LED monitors lights up at 80% of the stated current, and indicates the current direction as well. The maximum current is 3 times the stated current with an upper limit of 80 ma. 10

3.1. Introduction SAM232 COMPACT 3. Instructions for Use The SAM232 Compact can function as a breakout box, a status activity tester, a Ground Potential Difference tester, a cable tester, and a Current Loop tester. The following instructions explain basic tests that can be performed. 3.2 Breakout Box Functions/Patching Breakout functions do not require power. Depending on the configuration of equipment and the particular problem to be solved, the tester has to be connected either to one of the devices or between both instruments. Before connecting the tester, make sure the power is off in both devices. Connect the tester s leftside DB25 connector to one of the ports via a cable (preferably 25wire straightthrough), and connect the right DB25 connector to the other port. 11

SAM232 COMPACT Switch both devices ON. Enabling/disabling of individual lines via the breakout switches and jumpers, crossing over or bussing the access sockets allows for any modification of the standard interface. To solve problems of an existing interface switch, turn both devices OFF. Disconnect one end of the interface cable and connect it to the tester, then plug the tester into the free port. Switch both devices ON. All kinds of nullmodem and loopback configurations can be established, for example, to form a basic asynchronous nullmodem interface: Open (OFF) the breakout switch #2 and 3. connect left access socket #2 to the right socket # 3 via a jumper cable. connect left socket #3 to the right socket #2. Often in addition to lines 2 and 3, similar crossover of the control lines, usually #6 and 20, is required. 12

SAM232 COMPACT 3.3 Monitoring the Interface Signals The tester connected according to Section 3.2 immediately indicates the states of the signals transmitted by the interface. Each of the interface lines has two monitoring systems, located on either side of the corresponding breakout switch. Full monitoring doesn t depend on the positions of the breakout switches. The red LED lights when the corresponding circuit is in the SPACE/ON state; the green LED signals the MARK/OFF state. If both LEDs are off, there s no signal. LED light intensity depends on the strength of the monitored signal. 13

SAM232 COMPACT 3.4 ControlSignal Simulation Tests on the RS232 (V.24) interface often require signal simulation in various control lines. The SAM232 Compact simulates signals without a battery. Connect the access sockets belonging to the forced line to a line providing suitable voltage (often DTE lines 9 or 20 [DCE 6 or 9] can supply +V, while line 10 in many devices supplies V). 3.5 Ground Potential Difference Test Ground Potential Difference develops when two pieces of equipment are powered from different powerdistribution systems or when a ground problem occurs in one of the devices. Follow these steps to test Ground Potential Difference: Switch both devices OFF. Open (OFF) all breakout switches #1 through 25. Connect the tester between both devices via any cable supporting line #7. Switch both devices ON. 14

SAM232 COMPACT One of the Red LEDs located at position #7 lights up if G.P.D. is more than 2V. Problems with signallevel interpretation can occur when G.P.D. exceeds 2 volts. In that case, galvanic ground separation is required in one of the connected devices. 3.6 Current Loop Circuit Examination Though current loop differs substantially from the RS232 (V.24) standard, it is sometimes used in older RS232 (V.24) installations to communicate over longer distances or to establish ground separation. 15

SAM232 COMPACT The Current Loop test circuit is a unique feature of the SAM232 Compact that allows you to examine current loops mixed with the RS232 (V.24) circuits, as well as external currentloop interfaces (shorthaul modems). Follow these steps to test the current loop circuit using the RS232 (V.24) lines: Identify breakout switches belonging to the tested current loop. Disconnect one of the current loop wires by either opening the corresponding breakout switch or unplugging the jumper cable, closing the loop. Connect both ends of the opened current loop to the C.L. circuit inputs, via jumper cables, to the left input marked Common and the dedicated..ma access socket. 16

SAM232 COMPACT You can test independent current loops by connecting the open circuit to the input marked Common and the dedicated access socket marked..ma. In both cases one of the C.L. LED monitors lights when the current is at least 80% of the chosen range and shows current directions well. The currentloop test circuit does not require power from the builtin battery and is galvanically separated from the 25 RS232 (V.24) lines. 3.7 Cable Testing The SAM232 Compact can test any interface cable with DB25 connectors. To test the cable follow these steps: Open (turn OFF) all switches #1 through 25. Plug the cable into the left and right DB25 connectors. Connect the DC supply to the tester s upper left socket located at position #26. Connect the +DC supply to the left socket # 7. One of the Red LEDs (pos. # 7) will light if line # 7 is broken. 17

SAM232 COMPACT Run the jumper cable connected to the +DC supply through the left and right access sockets. Lighting LEDs indicate pins shorted in each connector as well as connections between the two. 18