System Configuration and orderinformation Guide RX600 S February 007
PRIMERGY RX600 S Front View CDROM Drive 5 inch Bay Display System Fan Hard Disk Bay Back View Serial Port Display PCI Slot 0/00/000BASET Connector Power Supply Inside View Expansion Board CPU front side
PRIMERGY RX600 S Instruction This document contains basic product and configuration information that will enable you to configure your system. Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete PRIMERGY Rack system. You can configure your individual PRIMERGY server in order to meet your specific requirements. Please follow the lines. If there is a junction, you can choose which way or component you would like to take. Go through the configurator by following the lines from the top to the bottom. The color of the junction means as follows. Key to Or And
PRIMERGY RX600 S Data Sheet Type 4Way Processor Rack Server Base Unit Xeon 740M (.40GHz) PGUR608A Xeon 70M (GHz) PGUR606A CPU Frequencies Dual Core Intel Xeon 740M (.40GHz) / 70M (GHz) SecondLevelCache ThirdLevelCache MultiProcessor xmb 6MB / 4MB max. 4 ( for standard) FrontSideBus Chipset 800MHz Intel E850 Standard GB (GB ECC DDR SDRAM DIMM x ) (SDDC(Single Device Data Correction) supported) Maximum * 64GB (4GB ECC DDR SDRAM DIMM x 6) *6 Graphics Controller Resolution * ATI RADEON 7000M, VRAM:6MB (PCI) 640x480/800x600/04x768/80x04 dot Internal Bays Number of bays 5.5 inch Available HDD * *4 7.4GB (PGHDH7W) 0krpm, U0 HDD 46.8GB (PGHDH4W) 0krpm, U0 00.0GB (PGHDHW) 0krpm, U0 7.4GB (PGHDH75W) 5krpm, U0 46.8GB (PGHDH45W) 5krpm, U0 Maximum * *4.5TB (00.0GB x 5) 5 inch Bay CDROM CDROM (Max. 4 ATAPI) PCI Slots PCI Express (x8) [x8] PCI Express (x4) [x4] PCIX (64bit/MHz) [.V] PCIX (64bit/00MHz) [.V] RAID Controller Controller onboard, 56MB Cache, BBU Ultra0 x ch (with RAID 0//5/0+(0) function) FDD optional *7 Network Controller (onboard) ports (000BASET/00BASETX/0BASET) Interfaces Display x (Analog RGB) *8, Serial Port (DSUB 9pins) x, USB x 6(ver..0) (Internal : x,external : x 5) *7 *9 Server Management Software Remote Service function ServerView (Standard) optional Power supply Voltage AC 00V(50/60Hz) Power consumption Redundant power supply 00W / 960kJ/h (max.) standard Redundant Fan Dimensions (W x D x H (mm) ) Weight standard 447 (48.6 incl. protruding parts)(w) x 706 (77 incl. protruding parts)(d) x 76 (4U) (H) 50kg (max.) Environmental Conditions Temperature05 C / Humidity 080% (non condensing) OS Support *5 Windows Server 00 R, Standard Edition / Windows Server 00 R, Enterprise Edition Windows Server 00, Standard Edition (SP) / Windows Server 00, Enterprise Edition (SP) Windows Server 00 R, Standard x64 Edition / Windows Server 00 R, Enterprise x64 Edition Windows Server 00, Standard x64 Edition / Windows Server 00, Enterprise x64 Edition Windows 000 Server (SP4) / Windows 000 Advanced Server (SP4) Red Hat Enterprise Linux AS (v. for x86) / Red Hat Enterprise Linux AS (v.4 for x86) Red Hat Enterprise Linux AS (v.4 for EM64T) Attached tool (Standard) ServerStart (Setup Support tool) *0 *. Available memory capacity will change with OS. More details can be found in Notes[ OS Compatibility List]. *. Resolution is determined by functions of the display monitor and OS. *. HDD capacity is calculated based on GB=000 byte and TB=000 4 byte. *4. All internal HDD must be configured as RAID structure. *5. Drivers for Linux are not attached. Please download and use drivers of the following URL. http://www.fujitsu.com/global/services/computing/server/ia/driver/ *6. Where x Expansion Board (PGRB06) are applied. *7. One USBFDD is required as a minimum in multiple servers. It is necessary to procure USBFDD separately. USBFDD can be connected to base unit with USB extension cable attached as standard. *8. Front and rear display connectors cannot be used at the same time. The Front display connector cannot be used with Windows 000 Server or Windows 000 Advanced Server. *9. Keyboard and mouse can be connected to base unit through KVM switch(4/8 ports) with USBKVM cable. *0. ServerStart doesn't support Linux.
PRIMERGY RX600 S Configuration Diagram Expansion Board D ( optional ) DIMM Slot B DIMM Slot A DIMM Slot B DIMM Slot A Power Supply Unit Expansion Board C ( optional ) DIMM Slot B DIMM Slot A DIMM Slot B DIMM Slot A PCI Slots PCI7 PCIX 64bit/00MHz PCI6 PCIX 64bit/00MHz PCI5 PCI Express (x4) PCI4 PCI Express (x4) PCI PCI Express (x4) PCI PCIX 64bit/MHz PCI PCI Express (x8) Power Supply Unit Expansion Board B ( optional ) DIMM Slot B DIMM Slot A DIMM Slot B DIMM Slot A Expansion Board A ( standard ) DIMM Slot B DIMM Slot A DIMM Slot B DIMM Slot A Hard Disk.5inch Bay Standard Drive Cage (HDDxch) Bay Bay 4 Bay Bay 5 Bay CPU Xeon 740M / 70M Xeon 740M / 70M Xeon 740M / 70M Xeon 740M / 70M CDROM Drive 5 inch Bay.5 inch HDD Bay 5.5 inch HDD Bay 4.5 inch HDD Bay.5 inch HDD Bay.5 inch HDD Bay *Components installed as standard configuration marked in grey. Mountable I/O Options PCI Slot Priority Mount Priority High Low Mountable Cards PGFC0 Fibre Channel Controller PGBFC0 PG86 Eth. Ctrl xgbit PCIE 000BASET PGB86 Bus PCI Express (x4) PCI Express (x4) PCI PCIX PCI PCIX Express Express x8 lane x8 socket 64bit/ M Hz Full Height x4.v.v socket 4 5 6 x4 lane 4 4 7 64bit/ 00MHz Max No. of Mount 4 4 PCI Express Card PCI Express Card Remarks PGRSB05 High Remote Service Board PGBRSB05 PG8 Internal/External Connector Ctrl U60 RAID Ctrl Channel 8MB w/bbu PGB8 PG4E PGB4E PCI/64bit PCI/64bit External array PG89 Low Eth. Ctrl 000BASET Cu Eth. Ctrl 000BASESX Fibre LC PGB89 PG88 PCIX/64bit PCIX/64bit Eth. x 000BASET Cu PG86 PCIX/64bit *:cannot be applied
PRIMERGY RX600 S Connection Table CPU CPU Slot Max: 4 CPU Processor Xeon 740M.40GHz/6MB PGFG40 PGBFG40 (for CTO/ for st additional CPU) PGBFG40 (for CTO / for nd additional CPU) *. This option is available when the processors of the base unit are Processor Xeon 740M.40GHz/6MB. Processor Xeon 70M GHz/4MB PGFG40 PGBFG40 (for CTO/ for st additional CPU) PGBFG40 (for CTO / for nd additional CPU) *. This option is available when the processors of the base unit are Processor Xeon 70M GHz/4MB. (Standard) ModuleGB (GB DIMM x ) Board PGRMBD Slot Standard : PGBRMBD (for CTO) GB (GB DIMM x ) Expansion Board Module4GB (GB DIMM x ) PGRB06 PGRM4BD 4 slot / Max: 4 PGBRM4BD (for CTO) Module8GB (4GB DIMM x ) PGRM8BD PGBRM8BD (for CTO) Module Conversion kit4gb (GB DIMM x ) PGBRU4BD (for CTO) Module Conversion kit8gb (4GB DIMM x ) PGBRU8BD (for CTO) (Optional) Max: ModuleGB (GB DIMM x ) PGRMBD Expansion Board Module4GB (GB DIMM x ) PGRB06 PGRM4BD Module8GB (4GB DIMM x ) PGRM8BD Installation. The installation order of Expansion Board is as following. Expansion Board A(standard) > Expansion Board B > Expansion Board C > Expansion Board D. Two same capacity DIMM cards should be installed at a time. Two different capacity DIMM cards shouldn't be installed at a time. Only one DIMM card shouldn't be installed at a time.. The installation order of is as following. () [DIMM slot A,B(Bank)] > [DIMM slot A,B(Bank)] () [ Module8GB(4GBDIMMx, Dual Rank )] > [ ModuleGB(GBDIMMx, Single Rank )] > [ Module4GB(GBDIMMx, Single Rank )] 4. Available Capacity OS Mounted Available Area Windows 000 Server (SP4) Windows 000 Advanced Server (SP4) Other OS ~.0GB 4.0GB ~6.0GB 8.0GB ~64.0GB Same as the size of mounted memory Size of Mounted minus ".0GB" Same as the size of mounted memory Size of Mounted minus ".0GB" Same as the size of mounted memory
PRIMERGY RX600 S 5. Spare Function Spare function assigns Spare by Expansion Board. () capacity of Bank and Bank should be same. () Spare structure should be made on all installed Expansion Board. () If spare function is applied, mirroring function and RAID function cannot be applied. (4) Available memory capacity is as following. When 8GB memory (4GBDIMMx, Dual Rank ) are installed : three quarters of installed memory When 4GB memory (GBDIMMx, Single Rank ) are installed : half of installed memory When GB memory (GBDIMMx, Single Rank ) are installed : half of installed memory The installation for Spare function is as following. Expansion Board A Bank Bank A B A B Expansion Board B Bank Bank A B A B Expansion Board C Bank Bank A B A B Expansion Board D Bank Bank A B A B 0 : is installed. : is not installed. 6. Mirroring Function Mirroring function assigns mirror set by Expansion Board. () capacity of Expansion Board of mirror set should be same. () The structure of mirror set is as following. When Expansion Board are installed : mirror set # ( Expansion Board A + Expansion Board B) When 4 Expansion Board are installed : mirror set # ( Expansion Board A + Expansion Board B) mirror set # ( Expansion Board C + Expansion Board D) () If mirroring function is applied, spare function and RAID function cannot be applied. (4) Available memory capacity is half of installed memory. The installation for Mirroring function is as following. Expansion Board A mirror set # mirror set # Bank Bank Bank Bank Expansion Board B Expansion Board C Expansion Board D A B A B A B A B A B A B A B A B 0 0 0 0 0 0 0 0 0 0 0 0 Bank Bank Bank Bank 0 : is installed. : is not installed. 7. RAID Function RAID function assigns RAID by 4 Expansion Board. () capacity of all Expansion Board should be same. () If RAID function is applied, spare function and mirroring function cannot be applied. () Available memory capacity is three quarters of installed memory. The installation for RAID function is as following. Expansion Board A Expansion Board B Expansion Board C Expansion Board D Bank Bank Bank Bank Bank Bank Bank Bank A B A B A B A B A B A B A B A B 0 0 0 0 0 0 0 0 0 : is installed. : is not installed. 8. Hot Plug Function If mirroring function or RAID function is applied, hot plug function of Expansion Board is available.
PRIMERGY RX600 S Connecting Internal HDD and Internal Backup Devices Onboard Ultra0 A Ultra0 B HDD HDD Type of HDD connection PRIMERGY RX600 S Internal Backup Devices PRIMERGY SX0 Internal Backup Devices Connection Interface USB ('') / Backup Devices Connection Wide ('') / Backup Devices Connection Wide ('') / Backup Devices Connection (''4) RAID Onboard (ChA/B) USB Cable (PGCBLU00) Card (PG8/PGB8) Cable (PGCBLS06) Card (PG8/PGB8) Cable (PGCBLS00/PGCBLS00) ('') USB Backup Devices: PGDT504 ('') Wide Backup Devices: PGLT0/PGLT0 ('') Wide Backup Devices: PGDT50/PGLT0/PGLT0/PGLT0 (''4) Backup Devices which occupies bays: PGLT0 Internal HDD RAID Configuration on board RAID controller Max: 5 HDDs HDD U0 0k 7GB hot plug " PGHDH7W PGBHDH7W (for CTO) HDD U0 0k 47GB hot plug " PGHDH4W PGBHDH4W (for CTO) *. On board RAID controller supports RAID 0//5/0+(0). *. More than two HDDs, which are same capacities and same revolutions, are required. HDD U0 0k 00GB hot plug " PGHDHW PGBHDHW (for CTO) HDD U0 5k 7GB hot plug " PGHDH75W PGBHDH75W (for CTO) HDD U0 5k 47GB hot plug " PGHDH45W PGBHDH45W (for CTO) Internal backup device () PCI Bus Tape Drv LTO Ultrium 00GB PGLT0 PGBLT0 (for CTO) Ctrl U60 Cable.0m PG8 PGCBLS06 PGB8 (for CTO) PGBCBLS06 (for CTO) Tape Drv LTO Ultrium 00GB PGLT0 Internal backup device (USB) slot / Max: USB Interface (internal) USB Cable PGCBLU00 PGBCBLU00 (for CTO) Tape Drv DAT7 6GB internal PGDT504 PGBDT504 (for CTO)
PRIMERGY RX600 S Internal DVDRAM On Board IDE Controller DVDRAM Conversion kit PGBDVAU0 (for CTO) Internal backup device (PRIMERGY SX0) PCI Bus Ctrl U60 Cable HDCI.5m PRIMERGY SX0 PG8 PGCBLS00 PGRBC4 PGB8 (for CTO) Cable HDCI 5m PGCBLS00 *Please find more information on the internal backup devices for PRIMERGY SX0 in Rackmount[Internal Backup Devices with PRIMERGY SX0 ] LAN Card Onboard LAN PCI Express Eth. Ctrl xgbit PCIE 000BASET PG86 PGB86 (for CTO) *Dual port Twist Pair Cable PCI Bus Eth. Ctrl x 000BASET Cu PG86 *Dual port Eth. Ctrl 000BASET Cu PG89 PGB89 (for CTO) Eth. Ctrl 000BASESX Fibre LC PG88 Multi Mode Fibre Channel Cable Server Management Card PCI Slot Remote Service Board PGRSB05 PGBRSB05 (for CTO) Twist Pair Cable Specifications are subject to change without notice. For the latest detailed information, contact your local representative. All brand names and product names are trademarks and registered trademarks of their respective holders. 006 Fujitsu Limited. All rights reserved. Printed in Japan. Global Business Development & Marketing Business Strategy & Planning System Products URL http://primergy.fujitsu.com