DS Type: MAXIM III Controller

Similar documents
DS October MAXIM 1010 Controller

DS December Omni BEMS Controller

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II

Installing and Configuring Rialto Analytic Appliances

BACnet. b3810 Series Local Controllers

TALON Network Manager- 2 & 6 Express

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Documentation on all Paxton products can be found on our web site -

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

NA502 Multiple RF Home Gateway

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Specification Sheet For electronically commutated motors

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

mark150s mark150/485s DDC controllers Summary

Andover ContinuumTM Infinet II

Andover ContinuumTM. b3850 Series Terminal Controllers

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Multi-Point Gas Detection and Control System

Power supply module, bus connection module

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

IMIO100 IMIO105. DDC controllers. Summary

Carbon Monoxide (CO) Gas Detection and Control System

NA502S Multiple RF Home Gateway

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

FX Input/Output (I/O) Modules XM07 and XM14

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

Millenium II +: general characteristics

Multi-Point Gas Detection and Control System

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

110 SERIES COMPACT NETWORK SWITCHES Quick Start Guide AN-110-SW-C-5P AN-110-SW-C-8P AN-110-SW-C-16P

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

BACnet. b3867 Terminal Controllers

Web interface BACnet/IP

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

DS A MN LCD I/A SERIES MICRONET LCD APPLICATION SPECIFICATION

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Windows-Based Terminal. TK-3550 H.W. Manual

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

TX-I/O Product Range. Description. Technical Specification Sheet Document No February 20, 2018

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

DS BAS 08/99 UNC 532

Super universal modules

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Multi-Point Gas Detection and Control System

LX Series Remote Input/Output (I/O) Controller

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Digital input modules

LN Series Remote Input/Output (I/O) Modules

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Operating instructions. Switching amplifier DN0210 DN / / 2015

Programmable controller MCX06C

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

BACnet/IP Web Interface

INSTALLATION INSTRUCTIONS

rcc.1081 Installation Instructions

Displays Transducers. Displays and transducers

DX-9100 Digital Controller, Version 2

Webdom Datalogger 1.5

Programmable controller Type MCX06C

IQ21x Series Controllers

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Network Control Engine Catalog Page

Installation instructions Inclination sensor EC2019 EC / / 2013

LBVR1718. Description. Features channel paperless recorder

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

ST-POEAF-S16-RM. 16 port PoE switch. User Guide

02/11/2015

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Neon pr. ph/ ORP measurement. Applications. Description

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

LX Series Free Programmable Controllers

PanelView Plus/VersaView CE Terminals and Display Modules

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

MC 11 EB-2 Power supply cabinet with external bus, AC version

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

HARDWARE GUIDE. Boiler Controller M2000 Series. Specifications and Operational Guide

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

MicroTech Modem Kit. Installation & Maintenance Data IM 682. Group: Controls Part Number: Date: October, 1996.

Eycon 10 and Eycon 20 Visual Supervisors Specification Sheet

4170 POS System Installation Guide

PXC Modular Series. Features. Description. Technical Specification Sheet Document No July 24, 2012

310 SERIES LAYER 2 MANAGED NETWORK SWITCHES Quick Start Guide

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Transcription:

DS 10.03 Models: MAX3ELD MAX3ELN MAX3NLD MAX3NLN Overview The Innotech MAXIM III Controller is a state of the art digital processing system that has the capability of controlling various types of industrial, commercial and domestic systems. The MAXIM III Controller can operate as a standalone device, using its own universal inputs and analogue and digital outputs to receive information and control external equipment, or as part of a network of Innotech devices that support Global Net Comms. The MAXIM III Controller's configuration program is developed on a computer using Windows based software. This allows the user to configure the internal processes of the MAXIM III Controller by using a graphical programming tool. The user places various process blocks and interconnecting lines to design the required control algorithm for the system. The configuration program can be downloaded to the MAXIM III Controller with an RS485 serial link, using the connector on the right side of the case to link to the computer via a 485/232 converter, or with an optional Ethernet link, using the RJ45 connector on the bottom right side of the case. These links may also be used to upload logged data or the program back out of the controller for modification or debugging purposes. Features 500 millisecond cycle/scan time 20 configurable universal inputs 12 digital relay outputs 8 analogue outputs Optional Human Machine Interface (HMI) on a 4 line, 20 character backlit LCD ** Optional Ethernet connection for Net Comms Status of I/O points displayed on LCD 80 user defined watches (up to eight pages of up to 10 watches) Data logging of 2MB, up to 300,000 readings 1 x RS485 serial communications port for Net Comms 1 x RS485 serial communications port for Global Comms User Selectable Baud Rates: (a) Net 9600 Global 4800 OR (b) Net 57600 Global 38400 All wire connections by 2.5mm plug-in screw terminals Program resides in non-volatile flash RAM Real Time Clock, battery backed for approximately 5 years Type: MAXIM III Controller Applications Innotech MAXIM III Controllers are designed for mounting inside a control cubicle and offer a variety of inputs and outputs enabling it to monitor and control all types of external plants and equipment. Although the MAXIM III Controller is flexible, it is primarily designed for the air conditioning and building automation industry. Within the MAXIM Series Digital Controllers family, the MAXIM III Controller provides the highest number of I/O points and the highest memory resources. The creation of control strategies is made simple by the use of the MAXIM Configuration Utility called MAXCon. With it's powerful Graphical User Interface, MAXCon allows the user to create an entire control strategy in block-diagram form. Typical applications include: Air conditioning and heating systems Lighting control Time clock controller Monitoring device Distributed I/O points controller Cold/Freezer Rooms Approvals The Innotech MAXIM III Controller conforms to: EN 61326:1998 for CE Marking and C-Tick Labelling Title 47 CFR, Part 15 Class A for FCC Marking UL listed to UL916, File Number E242628 ** Backlit LCD is only available on units manufactured after 2

Page 2 Specifications Power Supply 24VAC ± 10% @ 50/60 Hz 24V DC ± 10% Transformer nominal rating of 10VA. The operating voltage must meet the requirements of Safe Extra Low Voltage (SELV) to EN60730. The transformer used must be a Class 2 safety transformer in compliance with EN60742 and be designed for 100% duty. It must also be sized and fused in compliance with local safety regulations. Temperature Ratings Storage: 0 to 50 C non-condensing Operating: 0 to 40 C non-condensing Battery Contains a Lithium Battery requiring proper disposal Type CR-2032 Lithium Battery Nominal voltage 3 Volts Shelf life ~5 Years dependant on ambient temperature Caution: Risk of explosion if battery is replaced by an incorrect type. Enclosure/Mounting The MAXIM III Controller is housed in a rectangular case suitable for DIN rail mounting. The housing is moulded from flame retardant plastics recognized by UL as UL 94-V0. Colour: Grey. Dimensions (max): 224 mm(w) x 115 mm(h) x 74 mm(d). Inputs 20 Universal Inputs configurable via software to either: Dry Digital Inputs Voltage Digital Inputs 10k Thermistor Inputs 0-10 V DC LUX sensor input (Light sensor ORP12 LDR) Dry Duty Cycle Inputs Voltage Duty Cycle Inputs Dry Pulse Counter Inputs Voltage Pulse Counter Inputs Notes: Input combinations may be limited by the device and need to be set in pairs Input accuracy is ±0.1 volts Error is less than 0.2% with 15Hz Square Wave input LUX Sensor Input mode is useful for switching based on ambient light levels, but is not suitable for any operation which requires the accurate measurement or recording of light levels Input Type Input Range Output Range Analog 0-10 V DC 0-10 V DC Dry Digital Open or Closed OFF or ON Voltage Digital 0-10 V DC OFF or ON High Thermistor 100k to 680 ohms -20 C to 100 C LUX Sensor 1 Meg ohm to 0 ohms 3 to 2500 LUX Low Thermistor 662k - 12k ohms -50 C to 20 C Dry Duty Cycle Voltage Duty Cycle Dry Pulse Counter Voltage Pulse Counter Open or Closed 1 to 13 Hz 0-10 V Square Wave 1 to 13Hz Open or Closed 20ms Min. ON Time 20ms Min. OFF Time 0-10 V Square Wave 20ms Min. ON Time 20ms Min. OFF Time Communications RS485: 5-way plug in connector for local/remote computer access for the purpose of uploading, downloading and monitoring configuration programs, and the extraction of logged data via a 485/232 converter Ethernet: An optional RJ45 Ethernet port for PC and internet access to the MAXIM III Controller and other devices connected to it in an Innotech Net Comms network. This has the same functionality as an external RS485 to Ethernet Converter MAXIM III Model Number Designations RJ45 Logging Display MAX3 E L D MAX3 E L N MAX3 N L D MAX3 N L N 0 to 100% ±10% accuracy 0 to 100% ±10% accuracy 0 to 25 pulse/sec ±1 pulse accuracy 0 to 25 pulse/sec ±1 pulse accuracy Outputs 12 Digital Outputs: 12 x normally open relays (2 amp @24VAC supplied by a Class 2 Transformer Recommended use of pilot relays when switching high voltage/inductive loads 8 Analogue Outputs: Can be configured individually as either linear 0-10V DC or PWM outputs Output Load >2k Ohms Note: Up to 3 solid state relays can be connected in series to the analogue outputs when configured as PWM.

Page 3 Data Logging The MAXIM III Controller comes with a powerful Data Logging facility. Data Logging can be assigned to hardware and software points. Up to 300,000 time stamped readings can be stored on the MAXIM III Controller. All data is stored in a 2MB non-volatile flash RAM. When the memory becomes full, new readings replace the oldest readings. All logged data points can be extracted through the use of the MAXTract Software tool. User Interface For ease of use the MAXIM III Controller is provided with an option of a 4-line, 20 character backlit Liquid Crystal Display and keypad. The keypad consists of six navigational push buttons which provide input into the system. These buttons are Up, Down, Left, Right, Enter and Escape. By using these buttons, the user can gain access to the menu structure as shown below. The display has up to 8 programmable watch pages, each with it's own user defined description. Each page displays 10 points of information and allows access to the status of all I/O values and system information. The user can set clock/schedule variables and calibrate inputs. All information is displayed in English with standard engineering units. Initial Ethernet Port Setup The Ethernet port requires some initial setup according to the network configuration on site. EtherMate is capable of configuring the Ethernet via several options using the Ethernet RS485 interface. Note that an Innotech RS485 Converter will be required to configure the device if using the RS485 interface and connecting direct to a computer. 1. The Ethernet Port will require an IP address. The factory settings will enable the device to acquire an IP address from a DHCP server. If there is no DHCP server on the network the device will need a static IP address assigned. EtherMate can configure the IP address using the Ethernet interface or the RS485 interface. See EtherMate online help for more information on IP address assignment. 2. The Serial Port will need to be configured to match the RS485 network settings. The default is 57600bps, No Parity, 8 data bits and 1 stop bit. 3. The Port number used for the Ethernet connection will need to be configured to match the setting used in icomm. The default is 20000. See EtherMate online help for more information. FCC Class A Notice This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Modifications to this device, may void the authority granted to the user by the FCC to operate this equipment.

Page 4 Associated Software MAXCon - Innotech MAXIM Controller Configuration Utility. It allows the user to internally configure a MAXIM III by a simple point-and-click approach on a PC running Windows. MAXMon - The Innotech MAXIM Monitor is a monitoring and debugging utility designed to help with commissioning and troubleshooting a MAXIM III Controller. It displays the configuration from the MAXIM III Controller and allows the user to inspect, trend or modify the value at any of the points in the configuration while the controller is running. MAXIM III Simulator - The Innotech MAXIM III Simulator utility is Windows based software which simulates a MAXIM III Controller. The virtual MAXIM III Controller can be powered on, configured and interrogated in the same way as a physical MAXIM III Controller. Configurations can be downloaded and checked without requiring any hardware installation. icomm - A communications server used by application software to communicate with Innotech digital controllers. It supports multiple concurrent applications communicating to multiple device networks and serves as the communications hub of any HMI integrated device network. MAXTract - The data log extraction utility for a range of Innotech digital controllers. It allows extraction of all or part of the history log data residing on the MAXIM III Controller into a specified data format. InnoGraph - Innotech s data log graphing and analysis tool. While it has been designed to specifically cater for the data log graphing capabilities of the Innotech range, it has the flexibility to display data log graphing information from other sources. InnoGraph allows multiple graphs to be displayed in multiple windows simultaneously. Complete with a host of configurable display options, statistical analysis of data points, analogue and digital value support, active cursors, colour printing capability and comprehensive zooming and panning features, InnoGraph is your complete graphing package. Supervisor - A specialised dynamic monitoring utility for the GENESIS II and MAXIM Series Digital Controllers. It provides all the functionality that is available from the GENESIS II and MAXIM Series Digital Controller display panels with greater ease of use and flexibility. It is aimed at those users who require some feedback or control of the GENESIS II and MAXIM systems, but have no desire to be immersed in the technical details of a GENESIS II and MAXIM configurations. EtherMate - A specialised configuration tool for Ethernet enabled Innotech devices. It provides the functionality to set the RS485 baud rate, serial format and TCP/IP settings. Although the device is setup using the Ethernet interface it is possible to configure using the serial port from Terminal function. Magellan - An event-driven, object oriented real-time Supervisory Control and Data Acquisition package. It provides a simple, intuitive mechanism to effortlessly design either trivial or sophisticated supervisory or control programs using a dragand-drop approach.

Page 5 This page intentionally left blank.

Page 6 MAXIM III Controller: Dimensions and Connection Diagram