Density and Concentration Meters Generation M

Similar documents
Density and Concentration Meters Generation M

Laboratory Density and Concentration Meters. DMA Generation M DSA 5000 M

DMA 500. Density/Specific Gravity/ Concentration Meter. ::: Unique Density & Concentration Meters

DMA 35. Portable Density/Specific Gravity/Concentration Meter. ::: Unique Density & Concentration Meters

MCP 300/500 Polarimeter

DMA 500. Density/Specific Gravity/ Concentration Meter. ::: Unique Density & Concentration Meters

DMA 35N. Portable Density, Specific Gravity & Concentration Meter. ::: Unique Density & Concentration Meters

Portable Density and Concentration Meter DMA 35

The DDM 2911 PLUS Automatic Density Meter

The DDM 2911 PLUS Automatic Density Meter

The DDM 2909 Automatic Density Meter

The DDM 2911 Automatic Density Meter

The DDM 2911 Automatic Density Meter

The DDM 2911 Automatic Density Meter

Portable Density/Specific Gravity/Concentration Meter

The DDM Series of Automatic Density Meters

DMA 4200 M. Density Meter for the Petroleum Industry. ::: Unique Density & Concentration Meters

COBRIX 2 On-line Beverage Analyzer. Anton Paar

The DDM Series of Automatic Density Meters

L-Dens 4X7 Series. Process Density Sensors. ::: Process instrumentation at its best

The of Automatic For High Accuracy Applications The DDM Series of Automatic Density Meters

Cosmetics. Density, Refractive Index, ph and Color Multiparameter Analysis

The Autopol VI Automatic Polarimeter

The Perfect Fit for Over 40 Years

Reference Manual. Handheld Density Meter Densito/DensitoPro

Inkjet Printer UX Series

Sulfur-in-Oil Analyzer SLFA-60

Temperature Control and Cooling Technology First Choice in Temperature Control

LMI 4000 Series Melt Flow Indexers

DVM HPHT ULTRA HIGH ACCURACY SIMULTANEOUS DENSITY AND VISCOSITY MEASUREMENT

DISI-A Automatischer Tablet. DISI-A Automatic. high accuracy. Precise measuring reliable results

LMI 4000 Series Melt Flow Indexers

How flowmeters perform self-verification

Contact Angle Instruments For the measurement of surface properties

X2 Series Balances. Innovative Functional Solutions

EKOHEAT Induction Heating Systems

A 2 O Advanced Automated Osmometer

Digital Hydrometer SBS-2500 INSTRUCTION MANUAL. Storage Battery Systems LLC Instruction Manual for SBS-2500 Digital Hydrometer Rev.

Industrial pressure controller Model CPC4000

MultiTest 50 Tablet Hardness Tester

ProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements

Titration Automation. Fully Automate your Titration Processes for Maximum Efficiency and Security. Titration Automation

UPS-HSR. USB High Sample Rate. Pressure Sensor. Applications include, but not limited to: Product Highlights:

Quality Electrochemical Analysis Professional Meters Basic Meters Sensors

G.R.A.S. 40EN 1" Ext. Polarized Pressure Microphone

PROFITEST. Testing Protective Measures MASTER TESTER INSTALLATION

A 2 O Advanced Automated Osmometer

OHD S.A. Equipos y Sistemas de Monitoreo Ambiental

Sartorius DocuClip & Docu-pH Meter. The new standard for reliability in electrochemical analysis

LiquiSonic-Plato. SensoTech. Inline concentration measurement. Lauter tun Wort boiler Filtration Blending Packaging Brix

Difference is in the Details

MultiTest 50 Tablet Hardness Tester

Gloss. micro-gloss. Efficient gloss measurement makes your QC faster. In the lab, in production, at the customer s...

The Next Generation of Milk Analysis

Melt Indexer Series MI. Automated Extrusion Plastometers / Melt Indexers built to meet ISO 1133 and ASTM D 1238 specifications

NANOMETRIC LAB PRINTER. Plug & Play Solution for ultra-precise printing of conductive lines in nano-scale

X2 Series Balances. Innovative Functional Solutions

Multifunction Calibrator

FoamDDI. Foam Digital Detection Imaging

The basis for precision

PHYSICS Digital Measuring Devices

Quality Electrochemical Analysis Professional Meters Basic Meters Sensors

A 2 O Advanced Automated Osmometer

Versatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics

t e s t i n g t o p e r f e c t i o n

Designed to make your job easier MSA 2.0 and MSA 2.1 Electrofusion Units

Benefit from the Joint Competence of Trebing & Himsted

Size and Shape Particle Analyzer. Synchronizing Size & Shape Wet & Dry Measurements.01 to 4000 µm COATINGS

Micro calibration bath Models CTB , CTB

CI-150 Series. Airborne Particle Counters

Versatile. Innovative. Customizable M CVAF Mercury Analyzer

SWISS MADE EXECUTIVE. Precisa 360 ES

CoriolisMaster mass flowmeter Automation solution for mixing applications

Directory chapter 30

831 KF Coulometer. Never before has coulometric Karl Fischer water determination been so economical!

AR2008 Digital Abbe Refractometer

GX/GF Series. SHS Sensor Series Precision Balances. Unrivalled in capacity and resolution: 210g / 0.001g ~ 8100g / 0.1g TYPE APPROVED PRODUCT (GX)

Product Guide. Repeatable RH and temperature measurement for precise humidity control and validation

KRAL Electronics BEM 300 and BEM 500.

i-hydro 7900 Water Vapor Transmission Rate Testing System

Pneumatic High-Speed Pressure Controller Model CPC3000

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

SWISS MADE EXECUTIVE. Series 360 ES

Perfect Cycling Thermocycler

G.R.A.S. 40AP 1/2" Ext. Polarized Pressure Microphone, High Sensitivity

i-gastra 7200 Gas Permeability Tester

novo AlphaTack Plus accurate tack measurements made simple

Sophisticated in Detail, Versatile and Proven Worldwide. Your benefits include:

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Level gauges for your purposes

Transmitter Series M400 / M300 transmitters Extended ISM functions Easy handling Intuitive user interface Multi-parameter

PREPARE FOR THE G-STORM

40 years ago we invented the touchscreen. Today we're reinventing how people interact with their world.

High-end pressure controller Model CPC8000

CS2. Advanced Force Test System. 225 lbf (1kN) & 1100 lbf (5kN)

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

SWISS MADE. Series 320 XT PREMIUM. Analytical. Precision

Mass Flow Meters, Controllers and Manifolds

Plasma Low Temperature Sterilization. With vaporized hydrogen peroxide. PlazMax Line

Product Catalog. EasySampler EasySampler Unattended, Representative Sampling

Transcription:

Density and Concentration Meters Generation M DMA 4100/4500/5000 M ::: Unique Density & Concentration Meters

Vibrant Leadership since 1967 It all started in 1967: Anton Paar launched the first digital density meter with an oscillating U-tube sensor, marking a turning point for density measurement by replacing old-fashioned hydrometers and pycnometers. Hans Stabinger and Hans Leopold, two renowned Austrian scientists, invented the principle and developed the prototypes, and Ulrich Santner, then head of Anton Paar, took over production: The first DMA density meter was born. Since then Anton Paar has gained the reputation of being a first-rate partner for industry and research. The company s continuous focus on the development of innovative products famous for their high precision and efficiency has made Anton Paar the world leader in density and concentration measurement. At the same time an outstanding sales, service and application support network has been established. Continuously advanced generations of the famously robust DMA density meters became available, developed in cooperation with Labor für Messtechnik Dr. Hans Stabinger GmbH. The current models provide a patented reference oscillator (AT 399051), a built-in high-precision platinum thermometer and full-range viscosity correction. The new Generation M density meters combine the DMAs known excellent measuring capabilities with unparalleled levels of user confidence and comfort. A host of new features provides complete confidence in the sample filling and measurement process and therefore in the quality of the measurement results. From groundbreaking innovation in 1967 to the latest Generation M, Anton Paar always exercises vibrant leadership in digital density measurement. Be sure to go with the leader.

Results of Worldwide Value Industry Statement Use Beverages DMA has been established in our industry for years. 4 Determination of sugar content (g/l, Brix), alcohol content (%v/v, Proof) 4 Determination of extract content ( Plato, Balling) 4 Beer quality control 4 Quality control of soft drinks ( Brix) Pharma & Cosmetics DMA complies with our quality guidelines. 4 Quality control of raw materials and final products 4 Determination of specific gravity and density (g/cm 3, g/ml) of medicinal formulations 4 Filling volume determination Petroleum DMA is absolutely ideal for our highly viscous samples. 4 Quality control of raw materials and final products (API, kg/m 3 ) 4 Quality control of additives 4 Blending checks Flavors & Fragrances Small sample volume requirements are ideal for us, of course. 4 Quality control of raw materials and final products (g/cm 3 ) 4 Specification checks 4 Filling volume determination Chemicals Research and Development DMA is astoundingly resistant - an absolute must for our industry. The temperature scan saves us a lot of time. 4 Quality control of raw materials ( Baumé, g/cm 3, kg/m 3 ) and final products 4 Concentration determination of acids and bases (%w/w, %m/m, mol/l) 4 Solids content determination of dispersions 4 Reaction process control 4 Determination of partial specific volume 4 Determination of density gradient for ultracentrifuging 4 Density/temperature profile 4 Determination of molarity (mol/l) and normality (N) Calibration Offices, Testing Agencies We have been using DMA for more than twenty years. 4 Determination of alcohol content (%v/v, Proof) for fiscal reasons 4 Filling volume determination 4 Stability monitoring of density standards Biofuels In short: optimal quality control for an optimal product. 4 Quality control of raw materials and final products 4 Production control (%v/v, Proof, g/cm 3 ) 4 Blending checks DMA is also used in the food industry, semiconductor industry, biotechnology, plastics industry, automotive industr

Countless analytical methods prevail in today s quality and production control: One of the easiest, fastest and most significant is density measurement. It requires very little sample, does not change the sample s composition and consumes no chemicals. Density measurement determines concentrations from 0 % to 100 % with the utmost precision and allows you to always offer first-rate product quality. Description Standards Anton Paar s long standing experience as a measuring specialist for the beverage industry (soft drinks, beer, spirits, etc.) and the highly precise results DMA delivers in next to no time have established it as the benchmark for this field. 4 AOAC, international 4 OIV, international 4 ASBC, TTB (USA) 4 MEBAK, EBC international DMA meets the strict regulations in the pharmaceutical and cosmetic industries with electronic signatures, various user levels and internal write protection. 4 European and US Pharmacopoeia 4 21CFR part 11 4 cglp/gmp A thorough, fast viscosity correction and a measuring range up to 90 C make DMA the perfect density meter for highly viscous samples such as bitumen, heavy fuel oil, or crude oil. 4 DIN 51757, ISO 12185 4 ASTM D 1250, ASTM D 4052, ASTM D 5002, ASTM D 5931 Since DMA only requires a minimal amount of expensive sample for its density measurement in order to deliver highly precise results after very short measuring times, the instrument is highly valued in the flavors & fragrances industry. DMA is renowned worldwide for its robustness. The chemical industry relies on it. Apart from this, all common density/concentration tables are stored in the instrument, and new substances are easily programmed as a table or a polynomial. The use of DMA has considerably reduced the workload in the chemical industry. 4 ISO 2811-3, ISO 15212 The main reasons for R&D departments to choose DMA are the great accuracy, the small sample volume requirement and the temperature scan by means of the reference oscillator: The automatic temperature change right down to one-hundredth-steps guarantees easy, time-saving work. 4 ISO 15212 With density measurement results as accurate as up to 0.000005 g/cm 3, a temperature accuracy of 0.01 C and a sample volume requirement of only 1 ml, DMA is the high-precision reference instrument with the least sample consumption for calibration offices. 4 AOAC, international 4 OIV, international 4 ASBC, TTB (USA) 4 HM Customs and Excise (GB) Bioethanol producers use DMA because its unprecedented accuracy assures considerable savings. The biodiesel industry chooses the instrument for its robustness and thorough, fast viscosity correction. 4 EN 14214, ISO 12185 4 ASTM D 4806, ASTM D 4052 y, battery production.

Generation M A Step Ahead Imagine a density meter that you can be sure about. Be sure that the sample is filled correctly, the measurement is performed to the highest standards and the results leave no room for doubt. With Generation M, Anton Paar continues its leadership in providing the most accurate digital density meters on the market. Generation M density meters embody decades of experience. They build on the robust design and renowned features of past DMA generations: the integrated reference oscillator, built-in high precision platinum thermometer, and full-range viscosity correction. Generation M features all of this and more. These new features of Generation M provide complete confidence in the sample filling and measurement process and therefore in the outstanding quality of the measurement results: FillingCheck : Your density meter automatically detects filling errors or bubbles in the sample, alerts you and documents the incident. You can be sure of correct sample filling, whatever the conditions. U-View : Check the sample filling process on screen or recall stored images of the entire filled-in sample any time later. The stored images allow you to later verify correct sample filling and measurements, particularly when using automatic sampling systems. So you can safely walk away and let the instrument do the work. ThermoBalance eliminates the need for multi-temperature calibrations and allows you to quickly perform accurate measurements at very different temperatures. It compensates for drifts due to temperature stress, even when filling samples at temperatures very different from the measuring temperature, and provides stable readings over extended periods of time. Generation M density meters are the only instruments to provide you with all of these capabilities. Compliance: Generation M fully complies with 21 CFR Part 11 and cglp/gmp requirements. All adjustments, measurement results and reports are completely protected and passwords are verified based on specific password rules. Reports can be electronically signed. You can export measuring and adjustment data including date and time, serial number, user name, sample identification and other vital information.

The following features of Generation M density meters provide you with the highest levels of comfort and ease of use: User-friendliness: The easy-to-use touchscreen allows you to perform your tasks quickly and efficiently. Save time with the favorites button to access your most frequently needed menu functions. Assign different user levels to prevent any accidental changes. Symbols on the screen show you vital information, such as measurements in progress, FillingCheck alerts and the current status of an automatic sample changer/measuring module. Adaptable configurations: Use the soft keys below the touchscreen, a mouse or an external keyboard if you are working in a harsh environment. Enter sample identifications through a keyboard, a bar code reader, or via other means. Connect a large PC monitor or touchscreen to read the results or operate the instrument from afar. Choose from common density units such as g/cm 3, kg/m 3, pound/gallon and employ customer tables to calculate concentrations in units such as % w/w, % v/v. Automatic air adjustments: Rest assured that the local air pressure for air adjustments is correctly accounted for. Convenient data handling: Store your results in the instrument for as long as you want, and use the various interfaces for data export via memory stick, printer or Ethernet services. Reports are provided in popular formats such as PDF, TXT and XLS. Plug and Play sample changers: Space-saving automatic sample changers manage sample viscosities up to 35,000 mpa.s. Select an automatic sample changer according to the characteristics of your samples, plug it in and the density meter automatically recognizes it. Measure large numbers of samples automatically and perform your other important tasks while the instrument works for you. FillingCheck will alert you if any problem has occurred, while U-View allows you to verify results at a later time.

Five Steps to Success (1) Select method: Select the desired measuring method. There are ten industry-specific methods provided which can be adapted to your specific needs. When selecting a different method leads to a change in measuring temperature, ThermoBalance achieves stable readings in minimal time. (2) Enter sample identification: Enter a sample name or number via touchscreen or a connected keyboard or bar code reader. You can pre-configure the sample list before carrying out measurement series, particularly when using an automatic sample changer. (3) Fill sample: Fill the sample into the measuring cell. FillingCheck automatically detects filling errors or air bubbles in the filled-in sample and alerts you. With the models DMA 4500 M and DMA 5000 M, U-View displays live images of the sensor with the filled-in sample and stores images in the memory for later verification. (4) Start measurement: Start the measurement with the push of a button the results are ready in next to no time. You can observe the readings throughout the measurement on the screen. Errors related to sample viscosity are continuously corrected. (5) Read the results: Read the results directly from the display, the printout or a connected PC monitor. The results can also be transferred to a PC, LIMS or data storage device.

Measuring Density and Concentration Anton Paar s DMA density meters combine the groundbreaking oscillating U-tube principle, the integrated reference oscillator, highly accurate platinum thermometers and a full-range viscosity correction to provide exceptional measurement performance. The new features of DMA Generation M add an outstanding level of user confidence and comfort. This is how the density measurement works: The oscillating U-tube sensor is filled with 1 ml of sample. The instrument electronically excites the U-tube sensor to simultaneously oscillate at the fundamental resonant frequency and its harmonics. The oscillation characteristics are measured, with the integrated reference oscillator providing the pace. The reference oscillator is positioned in close thermal contact with the oscillating U-tube. This unique positioning enables the reference oscillator to compensate for all drifts arising from temperature stress applied to the U-tube sensor. From these measurements the density is determined with utmost accuracy and the viscosity influence is corrected. The following DMA models are available: DMA 4100 M 4 Accuracy of density measurement: 0.0001 g/cm 3 4 FillingCheck 4 ThermoBalance 4 Temperature scan DMA 4500 M 4 Accuracy of density measurement: 0.00005 g/cm 3 4 FillingCheck 4 U-View 4 ThermoBalance 4 Temperature scan DMA 5000 M 4 Accuracy of density measurement: 0.000005 g/cm 3 4 FillingCheck 4 U-View 4 ThermoBalance 4 Temperature scan

Automatic Sample Filling The Plug and Play sample changers of Generation M are designed to fit into the density meter, which saves you space on the lab bench. Measure large numbers of samples automatically and perform your other important tasks while the instrument works for you. FillingCheck will alert you if any problem has occurred, while U-View allows you to verify results any time later. Use the sample list to assign a separate method to each sample, if required. Interrupt the pre-configured sequence to insert a priority sample whenever you want, thus providing you with unprecedented flexibility and efficiency. These Xsample filling equipments from Anton Paar will meet your specific requirements: Xsample 22 Sample Filling Unit With peristaltic pump. For low-viscous samples and non-corrosive samples. Xsample 122 Sample Changer With peristaltic pump. For low-viscous samples and non-corrosive samples. Magazine for 24, 48 or 96 sample vials. Xsample 52 Sample Handling Unit With piston pump for measuring samples with completely diverse features in direct succession. Xsample 352 Filling and Rinsing Unit With piston pump and overpressure for precise filling of highly viscous or highly volatile samples. Xsample 452 Sample Changer With piston pump and overpressure for precise filling of highly viscous or highly volatile samples. Magazine for 24, 48 or 96 sample vials.

Anton Paar for You Combined forces Substantiated expertise The density meters and sample changers are produced by Anton Paar and advanced in close cooperation with Dr. Hans Stabinger, the inventor of the oscillating U-tube. The research and development team is geared to state-ofthe-art science and practice. Over 40 years of experience, powerful instruments and a contemporary operational concept made by Anton Paar. Regular training - in which both application topics as well as technical questions are covered - ensures that the service personnel and sales staff of Anton Paar are always up-to-date, valuable partners to Anton Paar customers. Custom-tailored after-sales service for you Vast application knowledge Anton Paar customers benefit from the vast and profound application knowledge of Anton Paar s specialists. New applications are continuously developed. A sales and service network of trained technicians is dedicated to customer support. The Anton Paar service team is always available, simply place your call. Company Structure Company headquarters Anton Paar GmbH Austria Countries with individual subsidiary, sales office or joint venture Sales operated by sales partners Direct sales by Anton Paar www.anton-paar.com

Specifications DMA 4100 M DMA 4500 M DMA 5000 M Measuring range Density Temperature Pressure 0 to 3 g/cm 3 0 to 90 C (32 to 194 F) 0 to 10 bar (0 to 145 psi) 0 to 3 g/cm 3 0 to 90 C (32 to 194 F) 0 to 10 bar (0 to 145 psi) 0 to 3 g/cm 3 0 to 90 C (32 to 194 F) 0 to 10 bar (0 to 145 psi) Accuracy Density Temperature 0.0001 g/cm 3 0.05 C (0.09 F) 0.00005 g/cm 3 0.03 C (0.05 F) 0.000005 g/cm 3 0.01 C (0.02 F) Repeatability std. dev. Density Temperature 0.00005 g/cm 3 0.02 C (0.04 F) 0.00001 g/cm 3 0.01 C (0.02 F) 0.000001 g/cm 3 0.001 C (0.002 F) Typical measuring time/sample* 30 s 30 s 40 s U-View No Yes Yes FillingCheck Yes Yes Yes ThermoBalance Yes Yes Yes Full range viscosity correction Yes Yes Yes Minimal sample volume Approx. 1 ml Wetted materials PTFE, borosilicate glass Dimensions (L x W x H) 482 x 340 x 231 mm (19 x 13.4 x 9.1 inches) Weight 22.5 kg (49.6 lbs) Power supply AC 100 to 240 V; 50 to 60 Hz; 50 to 80 VA Display 6.5 inches, TFT Touchscreen 640 x 480 Px Controls Touchscreen, softkeys, optional keyboard, mouse and bar code reader Communication interfaces 4 x USB, Ethernet, VGA, CAN, 2 x S-Bus, RS-232 Internal storage Up to 2 GB Special functions Temperature scan Temperature scan Adjustment at high density/ viscosity, temperature scan * After temperature equilibration

Photos: Croce & Wir Anton Paar GmbH Anton-Paar-Str. 20 A-8054 Graz Austria - Europe Tel: +43 (0)316 257-0 Fax: +43 (0)316 257-257 E-mail: info@anton-paar.com Web: www.anton-paar.com Instruments for: Density & concentration measurement Rheometry & viscometry Sample preparation Microwave synthesis Colloid science X-ray structure analysis Refractometry Polarimetry High-precision temperature measurement Specifications subject to change without notice. 09/09 C76IP01-D