Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies

Similar documents
Expert Reference Series of White Papers. Implementing Virtual Routing and Forwarding (VRF) on Cisco Nexus Data Center Switches

Traffic Monitoring. Traffic Monitoring

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

UCS Direct Attached Storage and FC Zoning Configuration Example

Course Description. Boot Camp Date and Hours: The class starts on Saturday 2 nd of April, 2016 Saturdays Only 8:00 AM 4:00 PM Central Standard Time

UCS Uplink Ethernet Connection Configuration Example

Overview. Cisco UCS Manager User Documentation

Fibre Channel Zoning

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

CCIE Data Center Written Exam ( ) version 1.0

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Cisco CCIE Data Center Written (Beta) Download Full Version :

Direct Attached Storage

CCIE Data Center Lab Exam Version 1.0

Cisco UCS Accelerated Accreditation Training

Cisco Cisco Data Center Associate Level Accelerated - v1.0 (DCAA)

CISCO EXAM QUESTIONS & ANSWERS

UCS deployment guide for Nimble Storage

Cisco UCS Local Zoning

Cisco. Exam Questions DCUCI Implementing Cisco Data Center Unified Computing (DCUCI)

Cisco UCS Virtual Interface Card 1225

UCS Technical Deep Dive: Getting to the Heart of the Matter

CCNP DataCenter. Cisco Certified Network Professional. Silver Learning

LAN Ports and Port Channels

Cisco Actualtests Questions & Answers

UCS Engineering Details for the SAN Administrator

You can monitor or use SPAN on port channels only for ingress traffic.

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch

CISCO EXAM QUESTIONS & ANSWERS

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

Exam Questions

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation


Rack-Level I/O Consolidation with Cisco Nexus 5000 Series Switches

Cisco UCS Manager Storage Management Guide, Release 3.1

Nexus 1000v Port-Channel Best Practices

Upgrading Firmware through Auto Install

Overview. Overview. Cisco UCS 6324 Fabric Interconnect with Cisco UCS B-Series Servers and C-Series Servers, which is. Overview 1

Cisco Nexus 4000 Series Switches for IBM BladeCenter

Cisco Unified Computing System for SAP Landscapes

UCS Firmware Management Architecture

Cisco Unified Computing Solutions

Vendor: Cisco. Exam Code: Exam Name: DCID Designing Cisco Data Center Infrastructure. Version: Demo

UCS Management Deep Dive

VersaStack for Data Center Design & Implementation (VDCDI) 1.0

Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches

Cisco UCS Manager Network Management Guide, Release 3.2

Midmarket Data Center Architecture: Cisco Unified Computing System with the Cisco Nexus 1000V Switch

Expert Reference Series of White Papers. How a Spanning Tree Works

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Expert Reference Series of White Papers. Voice Architectures and Deployment Models COURSES.

Maailman paras palvelinjärjestelmä. Tommi Salli Distinguished Engineer

UCS Management Architecture Deep Dive

Veeam Availability Suite on Cisco UCS S3260

This document is an introduction to Unified Computing System (UCS) Mini. UCS Manager software, Release 3.0, which supports only Cisco UCS Mini

V.I.B.E. Virtual. Integrated. Blade. Environment. Harveenpal Singh. System-x PLM

Fabric Failover Scenarios in the Cisco Unified Computing System

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group

Service Profiles. Service Profiles in UCS Manager

Introducing Cisco UCS Central 2.0

Configuring Service Profiles

Configuring Global Service Profiles

Q&As. Troubleshooting Cisco Data Center Unified Computing. Pass Cisco Exam with 100% Guarantee

UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer

Cisco UCS-Mini with B200 M4 Blade Servers High Capacity/High Performance Citrix Virtual Desktop and App Solutions

Implementing Cisco Data Center Unified Computing (DCUCI)


UCS Networking 201 Deep Dive

Implementing Cisco Data Center Unified Computing (DCUCI)

Configuring Cisco Nexus 7000 Series Switches

Overview. Overview. This chapter includes the following sections:

Equipment Policies. Chassis/FEX Discovery Policy

Vendor: Cisco. Exam Code: Exam Name: Designing Cisco Data Center Unified Fabric (DCUFD) Version: Demo

Overview of Cisco UCS Manager GUI

Expert Reference Series of White Papers. Understanding Data Centers and Cloud Computing

Overview. About the Cisco UCS S3260 System

Overview of Cisco UCS Manager GUI

FlashStack Virtual Server Infrastructure Deployment Guide: Cisco PowerTool Addendum

Data Center Certification

Q&As. Troubleshooting Cisco Data Center Infrastructure. Pass Cisco Exam with 100% Guarantee

Introducing Cisco UCS Central 1.4

Cisco Exam Implementing Cisco Data Center Unified Computing Version: 9.0 [ Total Questions: 173 ]

Traffic Monitoring and Engineering for UCS

Cisco Real Exam Questions - Guaranteed

UCS Networking Deep Dive

Real4Test. Real IT Certification Exam Study materials/braindumps

Cisco UCS Virtual Interface Card 1227

Cisco - DCNX7K: Configuring Cisco Nexus 7000 Switches

Troubleshooting Cisco Data Center Infrastructure (DCIT) 6.0

Exam Questions

Questions & Answers

SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper

Veritas NetBackup on Cisco UCS S3260 Storage Server

IT092: Implementing CISCO Data Center Unified Fabric

UCS Networking Deep Dive

Overview of Cisco Unified Computing System

Cisco UCS Director Tech Module Cisco UCS Manager (UCSM)

Service Profiles and Templates

Connect array to Cisco UCS and VMware vsphere

Transcription:

Expert Reference Series of White Papers Cisco UCS B Series Uplink Strategies 1-800-COURSES www.globalknowledge.com

Cisco UCS B Series Uplink Strategies Chris Olsen, Global Knowledge Instructor, Author, IT Consultant Overview of the Cisco UCS Infrastructure In 2014, Cisco Unified Computing Solution (UCS) became the number one server in the US in the x86 blade server market with more than 42 percent market share up from 2.4 percent in 2009. One of the main differentiators in Cisco s server solution is the capacity for two totally redundant failover paths for all server Ethernet and Fibre Channel traffic for every server. The other main differentiator is the Service Profile. See my other white paper titled Solving Issues on creating a UCS Service Profile for more info on troubleshooting Service Profiles. To illustrate the hardware options in UCS, log in to UCS Manager and under the Equipment tab and click on the Equipment icon. In the right pane, click on the Main Topology View. Cisco allows an option of either one or two Fabric Interconnects (FI) in a UCS management domain. If you have only one FI, then you will not be able to implement any UCS failover options and the topics in this white paper would not apply. Note that one of the FIs is labeled A, and the other B. These are the official names of the FIs and a maximum of two FIs are supported per a UCS management domain. Note that the above example shows only one chassis, however the concepts in this white paper apply from any of the one through twenty chassis supported by the currently available UCS Manager (UCSM) software versions. The focus of this white paper is on uplink strategies for traffic coming in and out of a UCS chassis. An uplink can be Ethernet, Fibre Channel, or FCoE and is a physical connection on the FI that leaves the UCS domain directed away from the B Chassis. Service Profile Configurations Cisco s implementation of stateless computing allows all the hardware settings of a server to be saved on a location outside the server itself. Stateless computing in UCS is implemented with an XML-based software feature called a Service Profile. In the event of disaster recovery, the amount of time to restore the server to its identical former condition is dramatically reduced with Service Profiles. Service Profiles contain virtually all possible hardware settings of a server, which can be applied, modified, or moved to a different blade. Copyright 2015 Global Knowledge Training LLC. All rights reserved. 2

Service Profile Fundamentals For starters, if a Service Profile is not associated with a blade (individual hardware server), the blade literally can t even be turned on. After you log in to UCS Manager (UCSM), highlight your server under the Equipment tab. Copyright 2015 Global Knowledge Training LLC. All rights reserved. 3

Note in this example under the General tab on the right for a server that the Overall Status is Unassociated and that the Boot Server option is greyed out. The point here is that without a Service Profile association, the server can t even be turned on. In UCSM, click on the Servers tab, and navigate down to your Service Profile. In this example a Service Profile was created with the name Pod8SP1. Copyright 2015 Global Knowledge Training LLC. All rights reserved. 4

The following are the critical requirements in the Service Profile to enable and optimize failover. First, it is mandatory to have a minimum of two vnics for an optimal failover design as well as for optimizing bandwidth in non-failover scenarios. It is very desirable to have more vnics, for sure! Highlight the first vnic. In the right pane, click the General tab. This example shows the WARNING because a vnic template was used, which causes the entries to be greyed out. While vnic templates are very desirable in a large UCS deployment to ease the repetition of configurations on many different blades, vnic templates do not enhance or reduce the failover options. What is important to note is the setting of fabric A or B (A in this example), and the selection of the Enable Failover box. Copyright 2015 Global Knowledge Training LLC. All rights reserved. 5

Now, click the next vnic in the service profile and again in the right pane, click the General tab. It is important to have the other Fabric selected (in this example B) and optimally the Enable Failover box checked as well. The idea is that during a non-failover scenario, half of the Ethernet traffic will leave the server to the A fabric, and the other half will leave the server to the B fabric. In the event of a failure or reboot of the A FI or the IOM in A, all will failover to B. Conversely, in the event of a failure or reboot of the FI or IOM in B, all will failover to A. As more vnics are added to the Service Profile, continue the same pattern, half vnics point to A with failover, and the other half of the vnics point to B with failover. Next, inspect the settings in the Service Profile on the vhba. There should always be a minimum of two vhbas in a Service Profile for proper failover. In this example, note how fabric A is selected. Copyright 2015 Global Knowledge Training LLC. All rights reserved. 6

Once again, inspect the other vhba, and ensure the other Fabric is selected, in this example, B. Also note that there is not a failover checkbox in the vhbas like there is for the vnics. End Host Mode vs. Switching Mode In the 1990s, the Spanning Tree Protocol did its job well blocking Layer 2 loops in an Ethernet network. However, in today s refined Cisco UCS datacenter design approach, losing bandwidth due to a blocked Spanning Tree port on even one 10 Gbps link is very inefficient, not to mention totally unacceptable. While there are several technologies in the data center to improve upon Spanning Tree, the default Cisco UCS method to eliminate Spanning Tree blocked ports on a UCS Ethernet uplink port is called pinning. Pinning is a logical path of connectivity that starts from the vnic to the Ethernet Uplink Port and from the vhba to the Fibre Channel Uplink port. Study the following drawing. For illustration purposes only, generation I hardware is shown on the left and generation II on the right. Pinning is illustrated with the blue arrows for Ethernet and orange for FC. Copyright 2015 Global Knowledge Training LLC. All rights reserved. 7

Pinning can be either static or dynamic. Static pinning was the only option in generation I hardware and always uses a single physical connection. Dynamic pinning is available only in generation II hardware and later and is far more desirable as it pins to port channels, which optimizes bandwidth and failover. Pinning is the default in UCS and is also called End Host mode. In UCS Manager navigate to Equipment > Fabric Interconnects and highlight one of your FIs. Under the General tab, note the four settings. In this example Set Ethernet End-Host Mode is greyed out as that is the current setting. Being foolish and turning on Set Ethernet Switching Mode turns pinning off and turns Spanning Tree on the uplink ports. Copyright 2015 Global Knowledge Training LLC. All rights reserved. 8

Uplink Port Channels and Virtual Port Channels (vpc) It is always desirable to have at the minimum basic port channels configured for both Ethernet and FC uplink ports. First, all individual uplink ports must be manually configured. In UCS Manager navigate to Equipment > Fabric Interconnects and highlight one of your FIs. Click on the valid cabled uplink port and click Reconfigure. After all links are configured as Uplink Ports, navigate under the LAN tab right click Port Channels and click Create Port Channel. Add the uplinks for both the A and the B path. The similar steps can be repeated for the FC connections under the SAN tab. Note there are no configuration options in UCS Manager for Virtual Port Channels (vpc) and none are needed. However, the Ethernet Uplink Port Channels can be enhanced upon even still by configuring vpc on the directly connected upstream Ethernet switches. The previous topology drawing shows the upstream device to be the Nexus 5xxx switch, but vpc works great on the Nexus 7xxx switches as well. The UCS Manager Port Channel configuration steps just described remain identical if vpc is properly configured on the upstream ports. Copyright 2015 Global Knowledge Training LLC. All rights reserved. 9

LAN and SAN Pin Groups In most UCS topologies, the only uplinks leaving the FI are those just discussed. However, in some unique design requirements, the uplink ports may need to go to different uplink switches. The ability to have some UCS server vnics send traffic to some uplinks and other server vnics to different uplinks requires the use of manually created pin groups. Under the LAN tab as show below, navigate to LAN Pin Groups, right click, and then click Create LAN Pin Group. Note that the only Port Channels or Uplinks that can be selected are those already created from the previous steps. Be very careful to select the correct ports. Copyright 2015 Global Knowledge Training LLC. All rights reserved. 10

For the Pin Group to be functional, it must be applied to each Service Profile. Under the Servers tab, navigate under your Service Profile, highlight the vnic, and in the General tab on the right select the Pin Group. Note that any one vnic may be configured for no Pin Groups (default) or just one manually configured Pin Group. The similar configuration can be done under the SAN tab in large FC data centers if different FC uplinks are required. Copyright 2015 Global Knowledge Training LLC. All rights reserved. 11

Conclusion UCS is a very popular and powerful solution driven by the flexibility and agility of the hardware failover options and the flexibility of Service Profiles combined with the power of path selection with the uplink ports. Learn More Learn more about how you can improve productivity, enhance efficiency, and sharpen your competitive edge through training. DCUCI - Data Center Unified Computing Implementation v5.0 DCUCS - Configuring Data Center Unified Computing v3.0 UCSTSBC - UCS Troubleshooting Boot Camp Visit www.globalknowledge.com or call 1-800-COURSES (1-800-268-7737) to speak with a Global Knowledge training advisor. About the Author Chris Olsen has been an IT trainer since 1993 and an independent consultant and technical writer since 1996. He has taught over 60 different IT, datacenter, and telephony classes to over 15,000 students. He is a technical editor for Global Knowledge s lab manuals and he has published two books with Cisco Press, CIPT2 and CCNA Voice Flash Cards. He is an author and technical editor on both Microsoft OCS 2007 and 2007 R2 certification exams, as well as a technical author for Cisco certified courses. Copyright 2015 Global Knowledge Training LLC. All rights reserved. 12