ELECTROSTATIC FIELDMETER

Similar documents
MANUAL. Electrostatic Field Meter EFM 022. System Prof. Dr.-Ing. Hans Kleinwächter

Electrostatic Field Meter EFM 022

TEST AND MEASUREMENT SRM 200 SRM 200/EFM 51 STARTERKIT

OPERATIONS MANUAL ACL 350 DIGITAL STATIC LOCATOR

ACL 350 Digital Static Locator

MANUAL. Handgelenksband WST 100. Handgelenksband- und Schuhtester. performance test for Electrostatic Wrist Straps and Conductive Shoes

Charge Analyzer 711. Operating Instructions. August

CHARGED PLATE ANALYZER CHARGED PLATE ANALYZER KIT

Wrist Strap & Shoe Tester WST 100

711 Charge Analyzer Operation and Maintenance

WALKING TEST KIT WT5000

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no

Operating Instructions

Operating Instructions

Electrostatic Fieldmeter Model 775

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

Operating Manual. FSM-2 Field Strength Measuring Gauge Part Number

7032 Digital-Analog Multimeter

ELECTROSTATIC FIELDMETER

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Earth Resistance and Resistivity Tester

3M Static Sensor 718, 3M Air Ionizer Test Kit 718A. User s Guide

Labour standards ESD protection

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Content. Operating manual BAL-EN Date Page 2 of 12

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

New earth resistance and ground resistivity meter - Sonel MRU-30

Complimentary Reference Material

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

TETRIS 2500 High Impedance Active Probe. Instruction Manual

99 Washington Street Melrose, MA Phone Toll Free Visit us at

ACL 380 Resistivity Meter

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

Energy Logger. User's Guide. Model EM Washington Street Melrose, MA Phone Toll Free

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

To connect the AC adapter:

INSTALLATION INSTRUCTIONS

RT-500 Megohmmeter Accurate - Best Value Today

ENGLISH. User manual.

ELECTROSTSTIC FIELDMETER

Model SRV411i Small Animal Floor Scale Service Manual Part No. MANSRV411i_ Page 1 of 16. Small Animal Floor Scale. Operating and Service Manual

AGATE TECHNOLOGY AT-2040

HD Field Meter, TV & SAT, Spectrum analyzer, MPEG HD pictures, SCR & SAT constellation. MPEG4 4.3 TFT 16:10. User s Guide UG-EASYMETER-EN V1,3

LSL250. Laser light! Do not stare into the beam or view directly with magnifiers. Class 2 laser EN :

7561-PSD Manual Portable Battery Powered Indicator

CHAPTER 2: USING MANAGER PREFERENCE. 2.1 Using Manager Mode Using CSAFE Console (back side) Access Layout...

PGT 120. Personnel Grounding Tester. Wrist Strap and Footwear Tester. Users's Manual

FMX-004. User Manual. Call the experts on us

OPERATION MANUAL ESD - GENERATORS

Kolectric Research. MC8022 Covermeter. Document number IM Iss 1 Copyright 2014 Tallix Ltd

BORESCOPE INSTRUCTIONS INSPECTION CAMERA RANGE RBS100 RBS200 RBS300. Retain these instructions for future reference

O P E R A T I O N A L MEGA-CHECK POCKET COATING THICKNESS METER M A N U A L

Platinum RTD Thermometer MODEL NO

Axiomet AXB Safety instructions

MulTI-Touch Projected Capacitive Touch Screen Integration Guide

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

DEFECTOMETER High detection sensitivity to surface flaws (even underneath paint) Simple, microprocessor-controlled operation

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

HI-POT TESTER User Manual

LOW WEIGHT, SMALL SIZE,

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

HI HI N HI HI

ESS-2000 with Discharge gun TC-815P

BC-7000 Field Calibration Procedure 55 AMP

PIECAL 520B & 521B Thermocouple Source Operating Instructions

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

TA330 HAND HELD AUTOMOTIVE SINGLE CHANNEL OSCILLOSCOPE AND MULTIMETER

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

EMOSAFE EN-10 Network Isolators with Protected Connector

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Manual Differential pressure meter PCE-910 / PCE-917

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

User Guide True RMS Multimeter Extech EX205T

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Portable Conductivity Meter M1410. User Manual 1.002

ISR-S400 ROUGHNESS TESTER OPERATION MANUAL

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

Drop-Off Release Transmitter

Operating Instructions

Platinum RTD Thermometer MODEL NO

EL7060 Series SERVICE MANUAL

Toughbook. CF-C1 MK1 refurbished. Table of Contents:

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

HI HI HI HI Portable Microprocessor Thermistor Thermometers

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Instruction Manual HI 9033 HI Waterproof Multi-Range EC and TDS Meters for Field Applications.

PIECAL 510B/511B RTD Simulator Operating Instructions

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Operating instructions. Speed monitor D / / 2014

PM-204A/B. Power Meter. Operation Guide

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

MANUAL TV-100 TV-100

PRODUCT INSTRUCTIONS MODEL SR-2 SOIL RESISTIVITY METER

REMOTE DISCHARGE PROBE

Transcription:

ELECTROSTATIC FIELDMETER Small hand-held Electro-Fieldmeter with digital display designed to measure electrostatic voltage potentials (with pre-selected distance) according the fieldmill influence principal. Item part numbers : o 61-200-0220 : Eletrofield meter (EU plug) o 61-200-0221 : Charge plate option o 61-200-0222 : Complete set : Electrofield meter+charge plate (EU plug) o 61-300-0220 : Eletrofield meter (UK plug) o 61-300-0222 : Complete set : Electrofield meter+charge plate (UK plug) 1

Contents Technical data 3 Operation instruction 3-5 Supplied accessories 5 Optionnal accessories 5 Charge plate (Kit CPS022) 6 Operation instruction CPS 022 7-8 Maintenance 7 Warning notice 8 Calibration 8 Legend 9 2

Technical data Description The unit is housed into an EMV - plastic enclosure. The Influence Measuring Electrode is star shaped. In front to it in a small distance apart a rotating grounded modulation propeller-wheel with the them shape is located. The Influence Electrode is jacket by a ring electrode system used also as mechanical shield for the propeller wheel and the sensor - plate. The measurement display is located on top of the unit. It is an 2x12 digit alphanumeric LC - display. The unit consists of a built in microprocessor for the following tasks as: it considers automatically the measured field strength (V/m) and the pre-selected distance (cm) to calculate the voltage potential (Volt) single push - button control permanent Battery voltage - control with automatic switch off CPS - mode Dimensions app. 70 x 122 x 26mm (L x l x H) Weight app. 130 gr. Distance between plate condenser 20 mm Adjustment error < 5 % Battery 9V Alkaline battery or NiMH - accu Operating time app. 10 hours with the 9V alk.battery Measure range : Distance 1 cm 0... 8 kv Resolution max 1 V Distance 2 cm 0...16 kv Resolution max 2 max. Distance 5 cm 0...40 kv Resolution max 10 max. Distance 10 cm 0... 80 kv Resolution max 10 max. Distance 20 cm 0...160 kv Resolution max 20 max. Operating instruction Principle of operation The Electro-Fieldmeter is working with a parametric amplifier. The charge caused by electrostatic induction is converted to an alternating current proportional to the field strength. A selective working amplifier measures the current without loss in relation to the field strength. There is no use of any radioactive materials in the unit Applications Detection and control of electrostatic fields or charges. Measuring: electric field strength electric charges, electrostatic charges, extremely high-resistent voltage sources. Function Key 3

on hold distance off 1 x press shortly function/on 1 x press shortly function/on to activate or deactivate 1 x press and hold function/on until change cm appears 1 x press shortly function/on to select the distance or switching in CPS - Mode wait for app. 2 sec to take over new function 2 x press shortly function/on button Operating Press the function/on -key to switch on the unit. Remove the protection cup from the modulator! Press the function/on -key twice in short intervals to switch the unit off. The unit will switch off automatically when the function/on -key was not used for about 3.5 minutes. Hold The unit has a hold-function keeping the measured value stored on the display. Press the function/on -key once shortly to activate the hold function - hold will appear then in the first row of the display, while the stored value is shown in the second row. To exit the hold-function, press the function/on - key once again shortly and the actual measurement value will appear on the display. Measurement ranges The distance of 2cm always is indicated when switching on the instrument. If this distance is used, the unit has to be positioned in the distance of 2cm monitoring the object. This distance is ideal in most cases, as voltage levels up to 16 kv can be measured (please note Technical Data). The distance should be increased, if the object is high charged or when the object has a rough surface. The lowest measurement distance of 1cm should be selected, when low charges are present and the surface of the object has a smooth surface. Change measurement distance Press and hold the function/on -key (approximately 2 sec.) until change distance will appear in the second line. The pre-selected distance in cm will be displayed in the first line. Press the function/on -key shortly to change the distance. With each short press of the function/on -key the proposed distance will appear as follows: 2cm => 5cm => 10cm => 20cm => cps - mode => 1cm... When the right distance is shown in the display, please wait (do not press the function/on - key) until the actual measurement value will appear in the second line. The new selected distance is now also shown in the first line. Please consider this selected distance for the following measurements. The distance will be measured from the electrode positioned 6.4mm apart from the housing on the modulator side. It is more practical to add 6.4 mm to any selected distance starting from the front - plate of the unit. Please note: the distance will change back to 2cm after each switching off and on again! Distance support 4

With any equipment you will get 2 distance supports. The distance supports can be screwed into the front - plate at the modulator side, which will always provide the right measurement distance for the standard setting of distance = 2 cm Display The alphanumeric Liquid Crystal Display (LCD) consists of 2 lines for 12 digits each. The measurement distance in cm will be shown in the first line, while the voltage reading in volts is displayed in the second line. When the level of 999 volts is reached, the display will switch automatically into the kv-mode. The display of the voltage reading appears always in 3 digits, such as: 578 V 3,85 kv 24.0 kv and 274 kv. Select a greater distance if overflow! appears on the screen! Battery voltage control The EFM 022 has a permanent battery-voltage control. If the battery voltage is less than 7,6 V Low Battery appears in the first line of the LCD and the 9V block-battery (or the accu) has to be replaced! If the battery voltage will become less than 7,1 V, then auto off will appear for approximately 2 sec in the second line and the unit will switch off to avoid a total discharge and acid leakage. Note: Please use Alkaline or rechargeable - NiMH 9V - batteries only! If rechargeable batteries are preferred, please use a suitable battery - charger for recharging the batteries separately. Please note the manufacturer`s advises! Grounding The unit has to be connected to ground for correct measurements of voltage levels and polarity. Use the grounding socket (4) of the unit for the connection to earth potential. The unit consists of a conductive housing, thus allow the use without grounding cable if the operator is on earth potential (e.g. wears conductive shoes, uses a wrist strap or touches grounded parts). Supplied options : The basic shipment contains the following parts: A B C B C D Transport Case with antistatic Foam Interior Electro Fieldmeter 9V Alkaline Battery& Battery Charger Ground Connector cable with clamp Instruction Manual Calibration Certificate Charge Plate Kit CPS 022 part number : 61-200-0222 5

With the Charge Plate Kit becomes from the EFM 022 a charge plate monitor, to the supervision of air ionization appliances after the EN 100015 as well as EOS/ESD S.3.1 The charge electrode corresponds to the norms from the capacity (20pF), but not from the dimensions. For directly measure conform to the norms, use our CPM 374. With the CPS 022, however reproducible measurements can be performed. It becomes the decay-time from + 1.000V. + 100V or.- 1.000V...- 100V with an integrated start - stop - timer. The charge takes place over an external HV- Converter. In the CPS-Mode voltages up to max. 2kV will be displayed. Parts of delivery HV Converter 3 rechargeable batteries Battery charger CPS Socket Plate condenser Grounding cables (1.5m & 1m) Crocodile plug Suitcase Operating instruction CPS022 6

The EFM 022 from software version V4.0 is prepared for using the Charge Plate - Monitor. Some older versions can be updated by the manufacturer Preparation of the unit Bring the CPS Socket in position and put in the EFM 022 vertically Screw the ground plate on the EFM 022 Press the field-plate onto the bolts in touch to the ground-plate Connect ground between the HV - Converter and the CPS Socket Connect the CPS Socket to ground Switch on the EFM 022 and wait until Dist.= 2cm" and a measure value is displayed Press and hold the function/on -key (approximately 2 sec.) until change cm will appear in the second line. The pre-selected distance in cm will be displayed in the first line. Press the function/on -key shortly to change the measurement distance, until CPS - Mode is displayed. With each short press of the function/on -key the proposed distance will appear as follows: 5cm => 10cm => 20cm => CPS - Mode please wait (do not press the function/on - key) until the cps-mode will appear in the second line. The unit is now ready to work as charge plate CPS - Measurement Through pressing of the button at the HV - Converter, a high voltage > ± 1100V becomes at the two contacts of the appliance generates Through touching of the upper field plate with the corresponding contact (+ or -) the HV-Converter is loaded the plate. ( see picture ) The unit recognizes the correct polarity automatically and now is ready for the measurement The internal timer is started with achievement of ± 1000V on the field plate The internal timer now counts upward in 0,1sec steps, as far as on the field plate ± 100V is reached In the upper line now it will displayed the pos. or neg. discharge time In the lower line, the current voltage is shown on the field plate, until the function/on" button is pressed. Then, the voltage measured at this time on the upper plate is shown as offset voltage in the lower line Pressing the function/on key again will reset the display, and it can be started a new measurement Maintenance Do not touch the modulator system to prevent mechanical damages. Avoid any insulating build up as e.g. dust, paint or varnish dust, condensed water or similar influence. If it is necessary the modulator system may be cleaned with alcohol and a soft fuzzy-free cloth. Replace 9V - battery The 9V block-battery has to be replaced when Low Battery appears at the display. Please switch the unit off before open the battery compartment. Take out the battery and remove the connector clip. Put the connector clip on the new battery and put it into the compartment. Close the compartment. 7

Zero Adjust A zero adjustment is normally not needed. In case, that the unit does not indicate U=00X while the modulator system is shielded (e.g. grounded person covers the modulator system with one hand), use the trimmer (6) for zero adjustment. The last digit can be ignored as the caused measurement failure is much lower than the specified tolerance. Guaranty Performance By correct operation and in accordance to the instruction manual we allow a 24 month warranty. The warranty does not include: The Battery / NiMH accu, damages by electrical discharge, incorrect grounding and mechanical damage of the Field Meter. If you opened the unit, you will lose the Guaranty! Warning notice It is not allowed to open the Electrofieldmeter. If you open it, you lost the guaranty. The Electrofieldmeter is not approved for measurements in explosion hazard areas. In the event of very high electrostatic charges, the Electrofieldmeter must be grounded. Look for an adequate distance to the test object. Avoid spark discharges onto the modulator system. The use of the unit in power plants is not permitted. The Electro-Fieldmeter is not equipped to detect alternating fields > 1Hz. Calibration It is advisable to recalibrate the Electro-Fieldmeter once a year. 8

Legend 1. Modulatorsystem 2. LCD Display (2 x 12) alphanumeric 3. Function Key 4. Grounding Socket 5. Battery Compartment 6. Zero Adjustment Trimmer 7. Protection Cup. remove for measuring!! 8. Distance spacer 2cm (screwed) 9