Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

Similar documents
EtherN.8 RDM & EtherN.2 RDM

Artistic Licence. Rail-Split RDM. User Guide. Serial nos and upwards. Rail-Split RDM User Guide. Version 5-0

Artistic Licence. Cata-Lynx I/P. User Guide. Cata-Lynx I/P User Guide. Version 1-4

Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7

Artistic Licence. Net-Lynx O/P. User Guide. Net-Lynx O/P User Guide. Version 1-5

Artistic Licence. Rail-Split extreme. User Guide. Serial numbers 151 upwards. Rail-Split extreme User Guide. Version 5-0

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Artistic Licence. Net-Lynx I/P. User Guide. Net-Lynx I/P User Guide. Version 1-5

Artistic Licence. versasplit. User Guide. versasplit User Guide. Version 1-5

Artistic Licence. Ether-Lynx II. User Guide. Ether-Lynx II User Guide. Version 1-5

SCD96 DMX Output Interface. Installation guide

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Artistic Licence. artlynx duo. User Guide. artlynx duo User Guide. Version 1-0

Artistic Licence. Mica. User Guide. Mica User Guide. Version 1-1

CS2 DMX Distribution Splitter

Artistic Licence. Rail-DALI-DMX. User Guide. Rail-DALI-DMX User Guide. Version 1-5

Artistic Licence. matisse d4 dmx. User Guide. matisse d4 dmx User Guide. Version 1-1

Microbar COB System. User Manual. Order code: EQLED137

Crossfire. User Manual. Order code: EQLED061

Blitzer Strobe. User Manual. Order code: EQLED366

RGB Power Batten. User Manual. Order code: EQLED032

UV Power Flood. User Manual. Order code: EQLED029

Chroma-Q Color Web PSU 10-DMX. User Manual

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Gobo Projector XP 80W

Ether-Lynx User s Guide

APT20. User Manual.

ZF LED Zoom Fresnel. User Manual

USER MANUAL Table of Contents

DMX512-A 2.10 HUB. User Guide

PF LED Profile. User Manual

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

USER MANUAL Table of Contents

Artistic Licence. daligate quad. User Guide. daligate quad User Guide. Version 1-0

w w w. p r o l i g h t. c o. u k STAGE PAR 64

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

Slimline CW & WW Series

User Guide. Control Box. RoscoLED TM.

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

Flexoled FTP3HP RGB LED DMX Driver

CDP 405 Digital Dimmer Pack

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

DMX LED Starcloth Systems

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Vector Beam White. User Manual. Order code: LEDJ265

HDMI 1x2 Splitter B-230-HDSPLTR-1x2 INSTALLATION MANUAL HDMI OUT 2 HDMI OUT 1 B-230-HDSPLTR-1X2 POWER HDMI IN

DMX512-A 1.5 HUB. User Guide

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

INSTALLATION MANUAL. HDMI 1x8 Splitter B-230-HDSPLTR-1x8 B-230-HDSPLTR-1X8

UV Spectra Batten 12 x 5W UV LEDs

Intense 9P10 RGBWA LED Slim Par

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Performer 18 RGBWA MKII

Microbar Multi System

Models DMX12DIM ELV Installation and Operations Manual

Endura 1Q120 RGBW COB Exterior Fixture

Vortex. User Manual. Order code: EQLED073

INSTALLATION MANUAL. HDMI 1x4 Splitter B-230-HDSPLTR-1x4. B-230-HDSPLTR-1x4 HDMI OUT 4 HDMI OUT 3 HDMI OUT 2 HDMI OUT 1 HDMI OUT 4 HDMI IN

MICRON DJ Booth Tri-colour Starcloth

Model DMX24DIM Installation and Operations Manual

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

Colour Burst Order code: LEDJ01 USER MANUAL

USERS GUIDE ASP-18H-4K. HDMI 4K2K 1x8 Splitter with EDID Management. Manual Number:

Hypnos. User Manual. Order code: EQLED372

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

Fusion Saber. User Manual. Order code: EQLED070

LIGHT BRICK - 12 X 3W TRI-COLOUR

DMX Tool Splitter 1 to 5 User Manual

iconverter 2-Module Power Chassis

FTP1 Single Channel LED DMX Driver

WLS27 Dual Color LED Strip Light

OPERATING MANUAL. DMX Booster/Splitter 3404C-H RDM Mk6

Order code: EQLED60 USER MANUAL

RDM Splitters Models RDS4 and RDS8

Intense 9HEX10 LED Slim Par

OPERATING MANUAL. DMX Booster/Splitter 3404C-H RDM Mk2

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

DMX Switch Pack. User Manual. EU version shown P/N

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

MICRON DJ Booth System with Overhead Kit & CW Starcloth

OPERATING INSTRUCTIONS

TECHCONNECT TC2-HDMI41 OWNERS MANUAL

Model DMX8DIM Installation and Operations Manual

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

UTAH-100/XHDA SERIES

DS-1H05 Ethernet-over-Coax Extender. User Manual

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

EasiLED 4 DMX Controller

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

CMSA-100 Manual. Cinema Media Server Automation

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

Kramer Electronics, Ltd.

Saturn Spot. User Manual. Order code: EQLED023

MC 11 EB-2 Power supply cabinet with external bus, AC version

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

User Manual TL-TP100-HDC2

Transcription:

Split2.8 RDM 2 input DMX/RDM Splitter User guide

Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be installed by a suitably qualified technician and in accordance with electrical regulations in the country of use. Unless directed in the instructions, there are no user serviceable parts inside the outer case of this Product. Always disconnect from the power supply when not in use. Any specific IP rating, where appropriate, is given in the instructions. Unless otherwise stated this product is designed for Indoor use only. If used outdoors it MUST be installed in an appropriate IP rated cabinet. Do not allow this product to be exposed to rain or moisture. Do not allow liquid to penetrate the product. Please recycle all packaging. Overview Split2.8 RDM is a 2 input, 8 output DMX & RDM Splitter than has individual input selection. Either of the two inputs may be routed to any of the eight outputs, by means of an A/B select switch. Housed in a metal case it is ideal as a desktop unit or, using the supplied Rack Ears, it can be easily mounted in any 19 rack enclosure. Using a standard IEC connector, Split2.8 RDM can be used anywhere in the world due to its universal mains voltage input. Both inputs are opto-isolated offering protection against high voltage accidents and eliminating potential Earth / Ground issues. Split.2 RDM supports all generations of DMX512 and is fully compliant with the Remote Device Management protocol (E1.20-2006 RDM). P2

Connections Ref Type Description 1 LED 2 LED 3 Data Connection 4 Data Connection 5 Data Connection 6 Data Connection Data / RDM & Power - Input A Data / RDM & Power - Input B DMX / RDM Input A Input A Loop Through DMX / RDM Input B Input B Loop Through 7 Data Connection DMX Output 1 8 Data Connection DMX Output 2 9 Data Connection DMX Output 3 10 Data Connection DMX Output 4 11 Data Connection DMX Output 5 12 Data Connection DMX Output 6 13 Data Connection DMX Output 7 14 Data Connection DMX Output 8 Ref Type Description 15 Switch Output 1 A/B Selection 16 Switch Output 2 A/B Selection 17 Switch Output 3 A/B Selection 18 Switch Output 4 A/B Selection 19 Switch Output 5 A/B Selection 20 Switch Output 6 A/B Selection 21 Switch Output 7 A/B Selection 22 Switch Output 8 A/B Selection 23 Fuse Mains Input Fuse 24 Power Connection Mains Input Connection P3

Electrical Wiring Split2.8 RDM has two DMX / RDM Splitters in one box. The outputs are switched to select what input port they are connected to. The Electrical connection is identical to a normal DMX Splitter. DMX Controller DMX Controller UNIVERSE A DMX / RDM Split2.8 RDM DMX / RDM UNIVERSE B UNIVERSE A UNIVERSE B UNIVERSE A DMX RDM RDM DMX Dimmer Packs DMX Fixtures DMX Fixtures P4

Mode of Operation Split2.8 RDM retransmits two DMX / RDM sources on upto eight of the outputs. Each output has an input selection switch that will define which input is connected. All connections use 5pin XLRs. DMX Inputs Both inputs on Split2.8 RDM use a male XLR connector along with a loop through female XLR connector. The loop through connection must be terminated if not being used. Each of the inputs is optically isolated from the outputs and Mains Earth. This isolation offers protection from potentially dangerous high voltage accidents. It can also eliminate potential Earth / Ground Differential issues as the input is not electrically connected to any of the outputs. DMX Outputs The DMX512 / RDM Outputs are provided on eight 5pin XLR female connectors. Each output is independently buffered. The source of the DMX512 / RDM is selected by the switch to the left of the output connector. Each output is capable of driving upto 32 DMX devices. It is not necessary to terminate the unused outputs. DMX512 Wiring XLR Pin RJ45 Pin Convention Function RJ45 Colour 1 7 Black Ground White / Brown 1 8 Black Ground Brown 2 2 Blue Data - Orange 3 1 Red Data + White / Orange 4 6 n/c Aux Data - Green 5 3 n/c Aux Data + White / Green PIN 5 PIN 1 PIN 1 PIN 5 PIN 4 PIN 3 PIN 2 PIN 2 PIN 3 PIN 4 XLR5 Female XLR5 Male P5

Front Panel Indicators Each input has its own set of LED indicators that report on the status of that input port. Data Green - Indicates that DMX512 data is flowing from input to all outputs (normal operation). Red: Indicates that RDM data received by the outputs is being returned to the controller. Power Red - Indicates good power and normal operation. Flashing - Indicates that a connected RDM device is jabbering (returning unwanted data continuously). RDM RDM (Remote Device Management) is a PLASA Standards protocol from the Technical Standard Program that allows Bi-Directional communication over standard DMX cable. This enables a controller to have access to a DMX / RDM fixtures configuration and to alter this configuration remotely. The most obvious use is to be able to remotely set the start address of the fixture. However there are many other benefits to RDM such as sensor feedback, firmware uploads and automatic patching. Split2.8 RDM fully supports the RDM protocol (E1.20-2006) but can also be used within networks where there is no RDM present. Power Supply The internal power supply provides a universal input in the range of 90 to 250V AC via a 3 pin IEC C13 Connector. The mains fuse should only be replaced with a 3.15A Slow Blow Fuse. Earthing The following table summarises the internal Earth interconnection and isolation: Please note that we use the term Earth-Ground to avoid international confusions. In Europe Earth-Ground is called Earth, in the USA Earth-Ground is called Ground. Circuit Chassis DMX512 Input (including Loop Through) Description Bonded to Earth-Ground Type: Pin 1: Shell: Isolated Connects to internal isolated circuit. No connection to Earth-Ground The connector shell is connected to chassis DMX512 Outputs Type: Grounded Pin 1: Shell: Connected to Earth-Ground The connector shell is connected to chassis Internal Logic Ground Connects to Earth-Ground P6

Mechanical Housing: 19" 1U Rack Enclosure Dimensions: 1RU (H) x 19" Rack (W) x 257mm (D) Mass: 2.8kg Mounting: Desktop or 19" Rack Mounting (with supplied Rack Ears) Electrical Input Voltage: 90-250V AC Input Connector: IEC C13 Male Input Power (max): 250W Duty Cycle: 80% @ 25 C Mains Earthing: Case connected to Mains Earth Mains Fuse: 3.15A Slow Blow Environmental Operating Temperature: 0 C to 40 C Storage Temperature: -10 C to +50 C Operating Relative Humidity (max): 80% Non-Condensing IP Rating: IP20 Indoor Use Only Certification: CE FCC, WEEE, RoHS Warranty: 3 Year (Return to Base) Package Contents Split2.8 RDM User Guide IEC Mains Lead Mounting Diagram User Interface / Indication Connections: 2 x 5pin Male XLR DMX Input 2 x 5pin Female XLR DMX Loop 8 x 5pin Female XLR DMX Outputs 1 x IEC C13 Male Mains Input Indication: Power / Data / RDM (for both inputs) Control 2 input / 8 Output DMX / RDM Splitter Input Protocols: DMX512, DMX512(1990), DMX512-A RDM V1.0 (E1.20-2006 PLASA Standard) Input Connector: 5pin Male XLR Output Protocols: Same as input Output Connector: 5pin Female XLR Configuration: Input selection switch (x8) Isolation DMX Input Opto-Isolated to 1kV DMX Output - Ground Referenced Protection Mains 3.15A Slow Blow Fuse Internal Resettable Fuse - Control Electronics +15kV ESD DMX Driver Protection Ordering Info Catalogue Number: Split2.8 RDM P7

Warranty All products manufactured by Cooper Controls are warranted to be free from defects in material and workmanship and shall conform to and perform in accordance with Seller s written specifications. For detailed warranty information, visit our website at www.coopercontrol.com This warranty will be limited to the repair or replacement, at Seller s discretion, of any such goods found to be defective, upon their authorized return to Seller. This limited warranty does not apply if the goods have been damaged by accident, abuse, misuse, modification or misapplication, by damage during shipment or by improper service. There are no warranties, which extend beyond the hereinabove-limited warranty, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS. No employee, agent, dealer, or other person is authorized to give any warranties on behalf of the Seller or to assume for the Seller any other liability in connection with any of its goods except in writing and signed by the Seller. The Seller makes no representation that the goods comply with any present or future federal, state or local regulation or ordinance. Compliance is the Buyer s responsibility. The use of the Seller s goods should be in accordance with the provision of the National Electrical Code, UL and/or other industry or military standards that are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous. Cooper Controls Ltd International Usk House, Lakeside, Cwmbran Gwent, NP44 3HD, UK Tel: +44 (0)1633 838088 Fax: +44 (0)1633 867880 Email: enquiries@coopercontrols.co.uk North America 203 Cooper Circle Peachtree City GA, 30269, USA Tel: +1-800-553-3879 Fax: +1-800-954-7016 Email: controls@cooperindustries.com www.coopercontrol.com Issue 1.0