Juniper EX4200 and EX4500 Update Guide for IBM Smart Analytics System 7700 and IBM Smart Analytics System 7710

Similar documents
System Manager Unit (SMU) Hardware Reference

System Management Unit (SMU)

Migrate Cisco Prime Collaboration Assurance

Before Contacting Technical Support

Bitnami MEAN for Huawei Enterprise Cloud

Performing Administrative Tasks

Juniper Secure Analytics Patch Release Notes

Cluster Upgrade. SRX Series Services Gateways for the Branch Upgrade Junos OS with Minimal Traffic Disruption and a Single Command APPLICATION NOTE

Firmware Management. Overview of Firmware. This chapter includes the following sections:

Bitnami Apache Solr for Huawei Enterprise Cloud

Working with Configuration Files

Configuring the JUNOS Software the First Time on a Router with a Single Routing Engine

Release Notes: J-Web Application Package Release 15.1A1 for Juniper Networks EX Series Ethernet Switches

Configuration Export and Import

Zenoss Resource Manager Upgrade Guide

KB How to upload large files to a JTAC Case

Server Utilities. Enabling Or Disabling Smart Access USB. This chapter includes the following sections:

Zenoss Resource Manager Upgrade Guide

Release Notes: J-Web Application Package Release 15.1A4 for Juniper Networks EX Series Ethernet Switches

Zenoss Resource Manager Upgrade Guide

Configuring SME Cluster Management

Deploying Cisco UCS Central

Oracle Enterprise Manager Ops Center

Using the Cisco NX-OS Setup Utility

MediaSense Installation

Bitnami Ruby for Huawei Enterprise Cloud

Bitnami JRuby for Huawei Enterprise Cloud

Troubleshoot Firmware

Configure Dynamic Host Configuration Protocol (DHCP) Image Upgrade Settings on a Switch through the Command Line Interface (CLI)

Managing Software. Upgrading the Controller Software. Considerations for Upgrading Controller Software

Requirements for ALEPH 500 Installation

Telnet/SSH. Connecting to Hosts. Internet Technology 1

Configuring the JUNOS Software to Upgrade the T1600 Router Chassis to LCC0 of a TX Matrix Plus Routing Platform

Performing Software Maintenance Upgrades (SMUs)

Avaya Aura System Manager 5.2 HA and CLI Restore

Web Interface Installation Guide. Version 8.2

Configuring Virtual Blades

File Transfers. Contents

Upgrade Guide for Cisco Digital Media System Release 5.0

Junos Reference Guide. JUNOsReference. 1 P a g e

SysadminSG RHCSA Study Guide

EMC Greenplum Data Computing Appliance to x Software Upgrade Guide. Rev: A02

Maintaining Cisco Unity Connection Server

Managing the Cisco APIC-EM and Applications

Release Notes: J-Web Application Package Release 17.4A1 for EX4300 and EX4600 Switches

Installing Cisco CMX in a VMware Virtual Machine

Using the Cisco NX-OS Setup Utility

Smart Install Concepts

Configuration Import/Export

COMMAND. JTAC support info. request suport information. Restore factory settins

Getting started with Raspberry Pi (and WebIoPi framework)

FTP UPLOADS/DOWNLOADS

LOMBA KETERAMPILAN SISWA

Perform Backup and Restore

Bitnami Piwik for Huawei Enterprise Cloud

Readme for Cisco Prime Collaboration Assurance/Analytics 10.0 Patch 2 (Service Pack 1)

WASABI SYSTEMS INC. Wasabi Storage Builder for NAS Quick Start Guide

Managing RAID. Entering the RAID Management Command Environment CHAPTER

Student Website Setup

TECHNICAL WHITE PAPER

Installing Cisco MSE in a VMware Virtual Machine

DUAL OS INSTALLATION

Upgrade Guide. SonicWALL Aventail E-Class SRA EX-Series v9.0.5

How to Use This Lab Manual

Upgrade Guide. Platform Compatibility. SonicWALL Aventail E-Class SRA EX-Series v Secure Remote Access

Entering the RAID Management Command Environment

Reset the Admin Password with the ExtraHop Rescue CD

STRM Series to JSA Series

Upgrading Firmware through Auto Install

Network Management Card. User Manual

NN Nortel Communication Server 1000 Linux Platform Base and Applications Installation and Commissioning

Simplifying Blade Server Update with Dell Repository Manager

NN Nortel Communication Server 1000 Linux Platform Base and Applications Installation and Commissioning

Lab 2: Setting up secure access

Configuring an IMAP4 or POP3 Journal Account for Microsoft Exchange Server 2003

Service Automation Monitoring and Troubleshooting

Intrusion Detection and Prevention IDP 4.1r4 Release Notes

WLM1200-RMTS User s Guide

Deploying Cisco Nexus Data Broker

The Plasmon UDO Archive Appliance

Dell EMC OpenManage Enterprise-Modular Edition Version for PowerEdge MX7000 Chassis. Release Notes

F5 BIG-IQ Centralized Management: Upgrading Logging Nodes to Version 5.1. Version 5.1

Lenovo Flex System SI Gb System Interconnect Module. Release Notes. for Networking OS 8.2

Perform Backup and Restore

How to Back Up Linux/UNIX Data Using SSHFS

HPE Knowledge Article

Licensing, Upgrading, and Downgrading

Juniper Secure Analytics Virtual Appliance Installation Guide

CDP Data Center Console User Guide CDP Data Center Console User Guide Version

Setting up PuTTY. CTEC1767 Data Communications & Networking CTEC1863 Operating Systems CTEC1906 Internet Computing

Renaming/Moving Parameter Files

IBM Tivoli Storage FlashCopy Manager for Custom Applications Version Installation and User Guide UNIX and Linux IBM

ShadowProtect Bare Metal Restore

Network Configuration Example

Configuring Administrative Operations

Open a browser and download the Apache Tomcat 7 and Oracle JDBC 6 JAR from these locations. The Oracle site may require that you register as a user.

Cluster Server Generic Application Agent Configuration Guide - AIX, Linux, Solaris

Using. Quick Guide. Contents. Connecting to an FTP server. Using the Quick Connect bar. From FileZilla Wiki

Understanding UCS Server Configuration Utility User Interface

Cisco Videoscape Distribution Suite Transparent Caching Troubleshooting Guide

Transcription:

Juniper EX4200 and EX4500 Update Guide for IBM Smart Analytics System 7700 and IBM Smart Analytics System 7710 Document version: v1.1 Introduction Follow this guide to update the Juniper EX4200 and the Juniper EX4500 switches on your system from version 12.3R1.7 to 12.3R3.4. This update fixes the problem with Fan/Blower Removed and Power Supply Removed events occurring in version 12.3R1.7. This guide assumes that you have corporate connection access to each of these switches. Follow the prerequisite steps, procedure, and post-requisite steps to update the switches. Prerequisites 1. Plan for an outage of approximately two hours. 2. Have the JunOS firmware update package readily available. To download the firmware, you must have a Juniper Networks user account. EX4500 Install Package (12.3R3.4): MD5 Checksum: 65df0e8e9e82c729d5ffc12eaaa1b3b0 http://www.juniper.net/support/downloads/?p=ex4500#sw EX4200 Install Package (12.3R3.4): MD5 Checksum: 26b75e12f5694d64c70ae760adb8da8e http://www.juniper.net/support/downloads/?p=ex4200#sw 3. Have the user guide for your system readily available. To download the guide, follow the next steps, according to your system model. IBM Smart Analytics System 7700 You must have an IBM user ID and follow this link: https://www14.software.ibm.com/webapp/iwm/web/reg/pick.do? source=idwbcu&lang=en_us Copyright IBM Corporation 2013 1

Select IBM Smart Analytics System 7700: User Guide and continue. Select the file IBM_Smart_Analytics_System_7700_User_04.pdf and download. IBM Smart Analytics System 7710 You must have an IBM user ID and follow this link: https://www14.software.ibm.com/webapp/iwm/web/reg/pick.do? source=idwbcu&lang=en_us Select IBM Smart Analytics System 7710: User Guide and continue. Select the file IBM_Smart_Analytics_System_7710_User_03.pdf and download. Procedure 1. Stop all the resources on the system in the specified order, according to your system model: IBM Smart Analytics System 7700 Stop the system resources in the following order: a) Warehouse applications module resources b) InfoSphere Optim Performance Manager resources c) Core warehouse resources, which include the core warehouse instance, the core warehouse database, and GPFS resources. If high availability is configured for the core warehouse, the DB2 database partition resources are stopped during this step. For detailed steps, see steps 1-4 in the "Stopping the IBM Smart Analytics System" section of Chapter 5 of IBM Smart Analytics System 7700 User Guide. IBM Smart Analytics System 7710 Stop the system resources in the following order: a) InfoSphere Optim Performance Manager resources b) Core warehouse resources, which include the core warehouse instance, the core warehouse database, and GPFS resources. If high availability is configured for the core warehouse, the DB2 database partition resources are stopped during this step. For detailed steps, see steps 1-3 in the Stopping the IBM Smart Analytics System section of Chapter 4 of IBM Smart Analytics System 7710 User Guide. 2. Unmount all NFS file systems in AIX. 3. Follow Section A1 to update the Juniper EX4200 switch. If you have multiple Juniper EX4200 members in Virtual Chassis follow Section A2. Make sure you have all the Copyright IBM Corporation 2013 2

information required to access the Juniper EX4200 switch: IP address, root access, and password. For each additional member in a Virtual Chassis, this step takes an additional 10 minutes. For example, two members in a Virtual Chassis requires 50 minutes, and three members in a Virtual Chassis requires 60 minutes. While the EX4200 switch is updating and rebooting, you can start steps 4 and 5. 4. Follow Section B to update the first Juniper EX4500 switch. Make sure you have all the information required to access the first Juniper EX4500 switch: IP address, root access, and password. 5. Follow Section B to update the second Juniper EX4500 switch. Make sure you have all the information required to access the second Juniper EX4500 switch: IP address, root access, and password. 6. After updating the switches, start all the resources on the system in the specified order, according to your system model: IBM Smart Analytics System 7700 1. Start GPFS and mount the GPFS file systems. a) Log in to the administration node as the root user. b) Issue the following command to start GPFS: /usr/lpp/mmfs/bin/mmstartup a c) Issue the following command to mount the GPFS-shared directories on all nodes: /usr/lpp/mmfs/bin/mmmount all -a 2. Mount all NFS file systems in AIX. 3. Start the resources on the system in the following order: a) Core warehouse resources, which include the core warehouse instance and the core warehouse database. If high availability is configured for the core warehouse, the DB2 partition resources are started during this step. b) InfoSphere Optim Performance Manager resources. c) Warehouse applications module resources. For detailed steps, see steps 4-7 in the "Starting the IBM Smart Analytics System" section of Chapter 5 of IBM Smart Analytics System 7700 User Guide. IBM Smart Analytics System 7710 1. Start GPFS and mount the GPFS file systems. Copyright IBM Corporation 2013 3

a) Log in to the administration node as the root user. b) Issue the following command to start GPFS: /usr/lpp/mmfs/bin/mmstartup a c) Issue the following command to mount the GPFS-shared directories on all nodes: /usr/lpp/mmfs/bin/mmmount all -a 2. Mount all NFS file systems in AIX. 3. Start all the resources on the system in the following order: a) Core warehouse resources, which include the core warehouse instance and the core warehouse database. If high availability is configured for the core warehouse, the DB2 partition resources are started during this step. b) InfoSphere Optim Performance Manager resources. For detailed steps, see steps 4-6 in the Starting the IBM Smart Analytics System section of Chapter 4 of IBM Smart Analytics System 7710 User Guide. Copyright IBM Corporation 2013 4

Section A1: Update Juniper EX4200 You must know the IP address of the switch you are updating and have root access to the switch. To apply the update to the switch: 1. Transfer the EX4200 update package (jinstall-ex-4200-12.3r3.4-domesticsigned.tgz) to the /var/tmp directory on the Juniper EX4200 switch via SCP or SFTP on port 22. You can use a program like FileZilla to complete the transfer. See Appendix C for sample FileZilla instructions. The file transfer takes approximately 5 minutes. 2. Log on to the switch via SSH as root. You can use a program like PuTTy for access. 3. Confirm that the update package was transferred correctly by confirming the checksum value of the package: a) Generate the checksum by running the following command: cli file checksum md5 /var/tmp/jinstall-ex-4200-12.3r3.4- domestic-signed.tgz b) Confirm that the command output matches the following output: MD5 (/var/tmp/jinstall-ex-4200-12.3r3.4-domestic-signed.tgz) = 26b75e12f5694d64c70ae760adb8da8e If the output does not match, the file did not transfer correctly. If the file did not transfer correctly, try repeating step 1. If the checksum test repeatedly fails, try downloading the file from Juniper again. Important: Do not continue until you confirm that the update package transferred correctly. If you continue with an incorrect update package, you will break your system. 4. Install the update package by running the following command: cli request system software add /var/tmp/jinstall-ex-4200-12.3r3.4-domestic-signed.tgz This step takes approximately 2 minutes. The command produces output similar to the following example: Checking pending install on fpc0 Validating on fpc0 Done with validate on all virtual chassis members WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Copyright IBM Corporation 2013 5

5. If you need to abort the installation: Run the following command and do not follow any further steps in this procedure: cli request system software delete /var/tmp/jinstall-ex-4200-12.3r3.4-domestic-signed.tgz This is your last chance to stop the installation of the update. 6. Reboot the switch with the following command to finalize the installation of the update: cli request system reboot You will lose your connection to the switch during this step. The switch takes approximately 15 minutes to reboot. The command produced output similar to the following example output: *** System shutdown message from root@swg-en1 *** System going down in 1 minute Shutdown at Sat Jan 26 09:31:01 2013. [pid 26661] 7. After the switch reboots, log on to the switch via SSH as root. You can use a program like PuTTy for access. 8. Verify that the new version of software is installed by running the following command: cli show version The command produces output similar to the following example output: ----------------------------------------------------------------- Hostname: swg-en1 Model: IBM 427348E J48E JUNOS Base OS boot [12.3R3.4] JUNOS Base OS Software Suite [12.3R3.4] JUNOS Kernel Software Suite [12.3R3.4] JUNOS Crypto Software Suite [12.3R3.4] JUNOS Online Documentation [12.3R3.4] JUNOS Enterprise Software Suite [12.3R3.4] JUNOS Packet Forwarding Engine Enterprise Software Suite [12.3R3.4] JUNOS Routing Software Suite [12.3R3.4] JUNOS Web Management [12.3R3.4] JUNOS FIPS mode utilities [12.3R3.4] Copyright IBM Corporation 2013 6

9. Copy the version to the alternate slice to ensure that if the system automatically boots from the backup partition, it uses the same Junos OS version by running the following command: cli request system snapshot slice alternate This step takes approximately 10 minutes. This command produces output similar to the following example output: ----------------------------------------------------------------- Formatting alternate root (/dev/da0s2a)... Copying '/dev/da0s1a' to '/dev/da0s2a'.. (this may take a few minutes) The following filesystems were archived: / Copyright IBM Corporation 2013 7

Section A2: Update Juniper EX4200 in Virtual Chassis You must know the IP address of one of the switches in virtual chassis you are updating and have root access to the switch. To apply the update to the switches in virtual chassis: 1. Transfer the EX4200 update package (jinstall-ex-4200-12.3r3.4-domesticsigned.tgz) to the /var/tmp directory on one of the Juniper EX4200 switches via SCP or SFTP on port 22. You can use a program like FileZilla to complete the transfer. See Appendix C for sample FileZilla instructions. The file transfer takes approximately 5 minutes. 2. Log on to the switch via SSH as root. You can use a program like PuTTy for access. 3. Confirm that the update package was transferred correctly by confirming the checksum value of the package: a) Generate the checksum by running the following command: cli file checksum md5 /var/tmp/jinstall-ex-4200-12.3r3.4- domestic-signed.tgz b) Confirm that the command output matches the following output: MD5 (/var/tmp/jinstall-ex-4200-12.3r3.4-domestic-signed.tgz) = 26b75e12f5694d64c70ae760adb8da8e If the output does not match, the file did not transfer correctly. If the file did not transfer correctly, try repeating step 1. If the checksum test repeatedly fails, try downloading the file from Juniper again. Important: Do not continue until you confirm that the update package transferred correctly. If you continue with an incorrect update package, you will break your system. 4. Install the update package by running the following command: cli request system software add /var/tmp/jinstall-ex-4200-12.3r3.4-domestic-signed.tgz This command updates all members of the Virtual Chassis. This step takes approximately 3-5 minutes per member. The command produces output similar to the following example: Checking pending install on fpc1 Checking pending install on fpc0 Pushing bundle to fpc1 Validating on fpc1 Copyright IBM Corporation 2013 8

Validating on fpc0 Done with validate on all virtual chassis members fpc1: WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately 5. If you need to abort the installation: Run the following command and do not follow any further steps in this procedure: cli request system software delete /var/tmp/jinstall-ex-4200-12.3r3.4-domestic-signed.tgz This is your last chance to stop the installation of the update. 6. Reboot the switches with the following command to finalize the installation of the update: cli request system reboot You will lose your connection to the switches and internal network during this step. This will reboot all switches in virtual chassis. The switches take approximately 15 minutes to reboot. The command produced output similar to the following example output: Rebooting fpc1 *** FINAL System shutdown message from root@swg-en0 *** System going down IMMEDIATELY Shutdown NOW! 7. After the switches reboot, log on to the switch via SSH as root. You can use a program like PuTTy for access. 8. Verify that the new version of software is installed on all switches by running the following command: cli show version Copyright IBM Corporation 2013 9

The command produces output similar to the following example output: ----------------------------------------------------------------- Hostname: swg-en1 Model: IBM 427348E J48E JUNOS Base OS boot [12.3R3.4] JUNOS Base OS Software Suite [12.3R3.4] JUNOS Kernel Software Suite [12.3R3.4] JUNOS Crypto Software Suite [12.3R3.4] JUNOS Online Documentation [12.3R3.4] JUNOS Enterprise Software Suite [12.3R3.4] JUNOS Packet Forwarding Engine Enterprise Software Suite [12.3R3.4] JUNOS Routing Software Suite [12.3R3.4] JUNOS Web Management [12.3R3.4] JUNOS FIPS mode utilities [12.3R3.4] fpc1: ----------------------------------------------------------------- Hostname: swg-en1 Model: IBM 427348E J48E JUNOS Base OS boot [12.3R3.4] JUNOS Base OS Software Suite [12.3R3.4] JUNOS Kernel Software Suite [12.3R3.4] JUNOS Crypto Software Suite [12.3R3.4] JUNOS Online Documentation [12.3R3.4] JUNOS Enterprise Software Suite [12.3R3.4] JUNOS Packet Forwarding Engine Enterprise Software Suite [12.3R3.4] JUNOS Routing Software Suite [12.3R3.4] JUNOS Web Management [12.3R3.4] JUNOS FIPS mode utilities [12.3R3.4] 9. Copy the version to the alternate slice to ensure that if the system automatically boots from the backup partition, it uses the same Junos OS version by running the following command: cli request system snapshot slice alternate all-members This will apply to all members in virtual chassis. This step takes approximately 8 minutes per member. This command produces output similar to the following example output: Copyright IBM Corporation 2013 10

----------------------------------------------------------------- Formatting alternate root (/dev/da0s1a)... Copying '/dev/da0s2a' to '/dev/da0s1a'.. (this may take a few minutes) The following filesystems were archived: / fpc1: ----------------------------------------------------------------- Formatting alternate root (/dev/da0s2a)... Copying '/dev/da0s1a' to '/dev/da0s2a'.. (this may take a few minutes) The following filesystems were archived: / Copyright IBM Corporation 2013 11

Section B: Update Juniper EX4500 You must know the IP address of the switch you are updating and have root access to the switch. To apply the update to the switch: 1. Transfer the EX4500 update package (jinstall-ex-4500-12.3r3.4-domesticsigned.tgz) to the /var/tmp directory on the Juniper EX4500 switch via SCP or SFTP on port 22. You can use a program like FileZilla to complete the transfer. See Appendix C for sample FileZilla instructions. The file transfer takes approximately 5 minutes. 2. Log on to the switch via SSH as root. You can use a program like PuTTy for access. 3. Confirm that the update package was transferred correctly by confirming the checksum value of the package: a) Generate the checksum by running the following command: cli file checksum md5 /var/tmp/jinstall-ex-4500-12.3r3.4- domestic-signed.tgz b) Confirm that the command output matches the following output: MD5 (/var/tmp/jinstall-ex-4500-12.3r3.4-domestic-signed.tgz) = 65df0e8e9e82c729d5ffc12eaaa1b3b0 If the output does not match, the file did not transfer correctly. If the file did not transfer correctly, try repeating step 1. If the checksum test repeatedly fails, try downloading the file from Juniper again. Important: Do not continue until you confirm that the update package transferred correctly. If you continue with an incorrect update package, you will break your system. 4. Install the update package by running the following command: cli request system software add /var/tmp/jinstall-ex-4500-12.3r3.4-domestic-signed.tgz This step takes approximately 2 minutes. The command produces output similar to the following example: Checking pending install on fpc0 Validating on fpc0 Done with validate on all virtual chassis members WARNING: A reboot is required to install the software WARNING: Use the 'request system reboot' command immediately Copyright IBM Corporation 2013 12

5. If you need to abort the installation: Run the following command and do not follow any further steps in this procedure: cli request system software delete /var/tmp/jinstall-ex-4500-12.3r3.4-domestic-signed.tgz This is your last chance to stop the installation of the update. 6. Reboot the switch with the following command to finalize the installation of the update: cli request system reboot You will lose your connection to the switch during this step. The switch takes approximately 15 minutes to reboot. The command produced output similar to the following example output: *** System shutdown message from root@swg-en2 *** System going down in 1 minute Shutdown at Wed Aug 28 18:46:15 2013. [pid 69624] 7. After the switch reboots, log on to the switch via SSH as root. You can use a program like PuTTy for access. 8. Verify that the new version of software is installed by running the following command: cli show version The command produces output similar to the following example output: ----------------------------------------------------------------- Hostname: swg-en2 Model: ex4500-40f JUNOS Base OS boot [12.3R3.4] JUNOS Base OS Software Suite [12.3R3.4] JUNOS Kernel Software Suite [12.3R3.4] JUNOS Crypto Software Suite [12.3R3.4] JUNOS Online Documentation [12.3R3.4] JUNOS Enterprise Software Suite [12.3R3.4] JUNOS Packet Forwarding Engine Enterprise Software Suite [12.3R3.4] JUNOS Routing Software Suite [12.3R3.4] JUNOS Web Management [12.3R3.4] Copyright IBM Corporation 2013 13

JUNOS FIPS mode utilities [12.3R3.4] 9. Copy the version to the alternate slice to ensure that if the system automatically boots from the backup partition, it uses the same Junos OS version by running the following command: cli request system snapshot slice alternate This step takes approximately 10 minutes. This command produces output similar to the following example output: ----------------------------------------------------------------- Formatting alternate root (/dev/da0s2a)... Copying '/dev/da0s1a' to '/dev/da0s2a'.. (this may take a few minutes) The following filesystems were archived: / Copyright IBM Corporation 2013 14

Appendix C: Transferring the Juniper Update Package The instructions below are an example of transferring a Juniper update package (jinstallex-4200-12.3r3.4-domestic-signed.tgz) to a Juniper switch using FileZilla and SFTP connection. The values entered in FileZilla in these instructions are shown in the diagram on the following page. Note: FileZilla will automatically transfer the file on port 22 when you specify an SFTP connection. 1. Fill in the following fields: a) Host: sftp://corpip where corpip represents the corporate IP address of the Juniper switch b) Username: root c) Password: password where password represents the password for the root user 2. Click Quickconnect. When you are connected to the Juniper switch, the file system will be displayed in the Remote site pane. 3. In the Local site pane, navigate to where the Juniper update package is located on your local system. In this example, the Juniper update package is located in the C:\Users\IBM_ADMIN\Downloads\ directory. 4. In the Remote site pane, enter /var/tmp as the target directory on the Juniper switch. 5. Drag the package (jinstall-ex-4200-12.3r3.4-domestic-signed.tgz) from the Local site pane to the Remote site pane. Copyright IBM Corporation 2013 15

Copyright IBM Corporation 2013 16