HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

Similar documents
QuickSpecs. HPE Rackmountable 3 Phase Uninterruptible Power Systems. Overview. (UPS R8000/3 and R12000/3)

QuickSpecs HP T750 UPS. Overview

R/T2000 G2 HP R/T 2200 UPS INTL HP R/T 2200 UPS JPN/TWN

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models. Overview. Retired

QuickSpecs. HP Parallel 3 Phase Uninterruptible Power Systems. Overview

QuickSpecs. HP Tower UPS T750 G2, T1000 G3, T1500 G3 Overview

QuickSpecs HP R3000 UPS. Overview

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

HP Uninterruptible Power Supplies Overview

QuickSpecs. R7000 Uninterruptible Power System (UPS) Overview

T1000 G2 and T1500 G2 1. Battery Compartment 1. Battery Compartment 2. LED display 2. LED display HP T1500 UPS INTL HP T1500 UPS JPN/TWN

QuickSpecs. HP R1500 G3 Uninterruptible Power Supply (UPS) Overview

QuickSpecs. R5000 Uninterruptible Power System (UPS) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks)

HP UPS R1500 XR. Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

QuickSpecs. HP R1500 G3 Uninterruptible Power Supply (UPS) Overview. Retired

QuickSpecs. Models HP UPS R3000 XR. Overview

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

UPS R12000 XR, N+X. Overview

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

QuickSpecs. HPE Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

QuickSpecs. HP Server Console Switches Overview

QuickSpecs. HPE Basic Power Distribution Units (PDU) Overview

QuickSpecs HP BladeSystem Breaker Panel

HP G4 Line Interactive Single Phase Uninterruptible Power Systems (UPS)

Retired. Is backup power creating cost and space issues in your data center racks?

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview

QuickSpecs. HP IP Console Switch with Virtual Media Overview

QuickSpecs. What's New New USB interface adapter compatible with CAC and virtual media. HP KVM Server Console Switch G2 with Virtual Media & CAC

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

The HP Server Console Switch with Virtual Media is backwards compatible with all HP Cat5 based Server Console Switches and interface adapters.

QuickSpecs. HP TFT7600 G2 KVM Console and Monitor (TFT7600 G2) Overview

16-Port Serial Console Server. 48-Port Serial Console Server

QuickSpecs. Why do you need a KVM Console for your rack? Why HP? HP KVM Console Kit. Overview

Retired. HP TFT7600 Rackmount Keyboard and Monitor (TFT7600 RKM) Overview

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

QuickSpecs HP Rack 5642

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

QuickSpecs. HPE Single Phase Tower UPS. Overview and Models. HPE Single Phase Tower Uninterruptible Power Systems (UPS) Why HPE Tower UPS solutions?

QuickSpecs. HPE Standard Power Supplies. Overview. HPE Standard Power Supplies

HPE Line Interactive Single Phase Uninterruptible Power Systems (UPS) HPE R1500 G4 JP/TWN Uninterruptible Power System

QuickSpecs. HPE Intelligent Power Distribution Unit (PDU) Overview

QuickSpecs. HPE UPS Network Module. Overview. Models HPE UPS Network Module Mini-slot Kit

Powering HP BladeSystem c7000 Enclosures

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

New G2 features allow for greater management of power and environment in IT racks

QuickSpecs. HP IP Console Switch G2 with Virtual Media & CAC. Overview

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Premium Online Series

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

QuickSpecs. HPE KVM IP Console Switch. Overview

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

The HPE Server Console Switch with Virtual Media is backwards compatible with all HPE Cat5 based Server Console Switches and interface adapters.

QuickSpecs. HP Rack Accessories. QuickSpecs. Retired

QuickSpecs. HPE Flexible Slot Power Supplies. Overview

QuickSpecs. HPE G2 Metered Power Distribution Units. Overview HPE G2 Metered Power Distribution Units

QuickSpecs. HP Modular Cooling System. Overview

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

QuickSpecs HP Power Manager 4.2

QuickSpecs. HPE Line Interactive Single Phase Uninterruptible Power System. Overview and Models. Why HPE Tower UPS solutions?

HPE T1500 Gen5 NA/JP UPS with Management Card Slot HPE T1500 Gen5 INTL UPS with Management Card Slot

HPE recommended options have best performance, value and availability.

NOTE: Beginning LATE May 2005, the HP R5500 XR UPS is qualified for use on HP9000 and Integrity Servers. Description

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

QuickSpecs. HP Rack G2 Series Overview

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

Smart-UPS RT APC SMART-UPS RT 2000VA 120V

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

QuickSpecs. HP Rack G2 Series. Overview

UPS R3000 XR Maintenance and Service Guide

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

Setting new standards for reliable power distribution and metering

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

QuickSpecs. HPE Apollo 6000 Power Shelf. Overview

Rack-mountable 14 drive enclosure with single bus, single power supply. Tower 14-bay drive enclosure, single bus, single power supply, LCD monitor

UPS Series. features: uninterruptible power supply. what great systems are built on.

QuickSpecs. Models. HP StorageWorks Modular Smart Array 30 Multi-Initiator (MSA30 MI) Enclosure. Overview

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus

QuickSpecs. HPE Serial Console Server. Overview

QuickSpecs. HP 1x4 USB/PS2 KVM Switch. HP 1x4 USB/PS2 KVM Switch. Models HP 1x4 USB/PS2 KVM Switch

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

AIS 3000 APC AIS kVA 400V w/3 Batt. Modules Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

HP PDU Best Practices

SmartOnline Hot-Swappable Modular UPS System On-line, double-conversion protection for mission critical applications

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

Powerstar PS3204rm2u True online 2KVA /1800W (19.7 deep)

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

Hardwired Uninterruptible Power Supply

SmartOnline 120V 2.2kVA 1.6kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets

Transcription:

Overview Crowded data centers and racks filled to capacity with storage devices, monitors, servers communications devices, and other equipment are driving the need for uninterruptible power with increased power density and power efficiency. The HP 3 Phase Uninterruptible Power provide just that. These rack-mountable Uninterruptible Power provide up to 12,000 watts (W) of power in a 6-U rack form factor. This equates to 2 KW per U space, which leads the industry in power density. The UPS R8000/3 and the R12000/3 use digital signal processing and a new On-line On Demand hybrid technology to answer the demands for increased power density and power efficiency. On-line On Demand combines the efficiency of a line interactive UPS, up to 97%, with the stability of a double conversion on-line UPS when power fluctuates beyond acceptable limits. Hot swappable batteries and electronics modules and an automatic bypass reduce MTTR (mean time to repair) down time in the event service is needed. UPS R8000/3 and R12000/3 front view UPS R8000/3 and R12000/3 rear view 1. Battery compartment (behind bezel) 1. Communications terminal block 2. Menu navigation buttons 2. Output circuit breaker 3. Status and alarm LED display 3. Input circuit breaker 4. Electronics module compartment (behind bezel) 4. Battery circuit breaker 5. Input/output location R8000/3, input location R12000/3 1 6. ERM connector 7. Option card slots 8. Output connector R12000/3 9. Ground bonding screw 10. DB9 Service port 11. REPO port DA - 12857 Worldwide Version 8 June 20, 2011 Page 1

Overview Models HP R8000/3 HP R8000/3 8000kVA Three Phase NA 6U Rackmount Uninterruptible Power System AF431A HP R8000/3 8000kVA Three Phase INTL 6U Rackmount Uninterruptible Power System AF432A HP R12000/3 HP R12000/3 12000VA Three Phase NA 6U Rackmount Uninterruptible Power System HP R12000/3 12000VA Three Phase INTL 6U Rackmount Uninterruptible Power System AF429A AF430A DA - 12857 Worldwide Version 8 June 20, 2011 Page 2

Standard Features Key Features Unity Rated, volt amperage out equals wattage out Highest wattage per U space. Up to 12000 VA/12KW in only 6U Industry leading efficiency with On-line On Demand hybrid technology Attached line cords for easier and faster connection to your facility power Hot-swappable battery and electronics modules provide ease of maintenance and faster time to repair (MTTR) Industry leading efficiency with On-line On Demand hybrid technology Attached line cords for easier and faster connection to your facility power Extra long battery life with Enhanced Battery Management (EBM) Extended battery run time with optional Extended Runtime Modules (ERMs) Easy configuration through enhanced front panel display or HP UPS Management Module (included) Backed by a limited three-year warranty, HP's pre-failure warranty and a load protection guarantee in North America Superior Battery Management HP UPS HP 3 Phase UPS incorporates Enhanced Battery Management: an exclusive, patented technology that doubles battery service life, optimizes battery recharge time, and provides advance notice of pending battery failure. With Enhanced Battery Management, you have a lower total cost of ownership and receive the best in the industry protection for your critical equipment. Ease of serviceability through hot-swappable batteries and electronics modules. The HP 3 Phase UPSs have a modular design architecture, consisting of separate, hot swappable battery and electronics modules. Further, a built-in intelligent automatic bypass feature ensures continuous power to your connected load even while the modules are being replaced. Ease of maintenance and serviceability Faster time to repair (MTTR) Automatic and manual bypass Increased flexibility through modular design Increase battery back-up time with up to four Extended Runtime Modules HP 3 Phase UPS supports a maximum of four Extended Runtime Modules (ERM), to further increase your battery back-up time, should you have a sudden brief power outage. Each ERM is 3U high and can be automatically detected and configure when attached to the UPS. For more information on battery back up times, please refer to the Back-up Times Chart. Multiple management options increase flexibility The HP 3 Phase UPS systems can bee fully configured and monitored from the front management LCD. For remote management the HP UPS Management Module is included at no charge and provides additional features such as out of band communications with up to 5 servers and UPS clustering for redundancy. Remote Emergency Power Off Feature The HP 3 Phase UPS includes an isolated REPO (Remote Emergency Power Off) port. The REPO feature allows the power to the UPS outlets to be switched off from a remote location. For more information, refer the HP 3 Phase UPS users manual. DA - 12857 Worldwide Version 8 June 20, 2011 Page 3

Standard Features UPS Management Module The HP UPS Management Module enables you to monitor and manage power environments through comprehensive control of HP UPSs. The HP UPS Management Module can support either a single UPS configuration or provides additional power protection with support for dual redundant UPS configuration for no-single-point-of-failure. The additional serial ports will provide greater power management control and flexible monitoring. The management module can be configured to send alert traps to HP Insight Manager and other SNMP management programs or used as a standalone management system. This flexibility enables you to monitor and manage UPSs through the network. To facilitate day-to-day maintenance tasks, the embedded management software provides detailed system logs. The HP UPS Management Module provides remote management of a UPS by connecting the UPS directly to the network. Configuration & Management of the UPS from anywhere and at anytime via a standard web browser. NOTE: For more information on the UPS Management Module please see: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/software/module/ups/ index.html Warranty Standard three year warranty with first year including parts and labor. HP UPSs are backed by a standard three year limited warranty; 3 year parts, 1 year Labor, 1 year onsite. Optional UPS HP Care Pack and packaged services are also available for purchase. You can choose the precise level of support based on your needs, from basic to business critical. Pre-Failure Battery Warning and its associated Warranty. The Pre-Failure Battery Warning is proactively detected and notified by a LED indicator light, showing that the battery needs to be replaced. This notice is given 30 days prior to the battery failure. This indicator provides ample time to order a spare battery (1-800-HP-INVENT). Avoid storing battery spares as a back up because of short shelf life of the battery. The battery warranty coverage is 3 years for parts. The warranty for the first year of ownership includes parts and labor. Warranty, standard on all HP Uninterruptible Power System (UPS) units, extends the advantage of a HP three-year limited warranty by applying it to the battery before it actually fails. Specifically, the Pre-Failure Battery Warranty ensures that when customers receive the notification from their HP UPS that the battery may fail, the battery is replaced free of charge under the warranty. HP maintains the highest standards in the industry, as evidenced by the HP Pre-Failure Battery Warranty. In addition, HP UPSs are covered by a $250,000 equipment protection guarantee. Should your connected equipment get damaged due to a UPS failure, then your damaged equipment is covered to up to $250,000. NOTE: The $250,000 Equipment Protection Guarantee is offered only in North America. DA - 12857 Worldwide Version 8 June 20, 2011 Page 4

Service and Support HP Care Pack Services HP Care Pack Services include HP branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the enclosure, as well as 22" and smaller external monitors and rack mounted UPS options. HP Uninterruptible Power will be covered at the same service level and coverage period as the server. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or resellers or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html NOTE: The information contained herein is subject to change without notice and is provided "as is" without warranty of any kind. NOTE: The warranties for HP products and services are set forth in the express limited warranty statements accompanying such products and services. DA - 12857 Worldwide Version 8 June 20, 2011 Page 5

Related Options Extended Runtime Module HP UPS R8000/3 R12000/3 Extended Runtime Module NOTE: HP 3 PHASE UPS supports a maximum of four Extended Runtime Modules (ERM), to further increase your battery back-up time. Each ERM is 3U high and can be automatically detected and configure when attached to the UPS. For more information on battery back up times, please refer to the Back-up Times Chart. AF434A Serial Adapters for UPS Management Module HP RJ45-DB89 DCE Female 5 Pack Serial Adapter NOTE: The serial adapters allow direct (serial) connections to up to 5 servers with the UPS Management Module for out of band communications in the event of a power failure. AF402A Rackmount Power Distribution Units (PDUs) and PDU options North America/Japan HP 24A 3PH Modular Power Distribution Unit HP Single Input 3 Phase 24A Monitored Power Distribution Unit HP Dual Input 3 Phase 24A Monitored Power Distribution Unit NOTE: The HP R8000/3 UPS can support one AF512A or AF504A. The HP R12000/3 UPS can support two AF512A or AF504A or one AF503A. International HP 16A 3PH Modular Power Distribution Unit HP Single Input 3 Phase 16A Monitored Power Distribution Unit HP Dual Input 3 Phase 16A Monitored Power Distribution Unit NOTE: The HP R8000/3 UPS can support one AF513A or AF508A. The HP R12000/3 UPS can support two AF513A or AF508A or one AF507A. HP PDU Management Module NOTE: For more information on the PDU Management Module please see http://h18004.www1.hp.com/products/servers/proliantstorage/ powerprotection/pdu.html AF512A AF504A AF503A AF513A AF508A AF507A AF400A PDU Extension Bars (PDU options) HP Two C13 PDU Extension Bars NOTE: Each extension bar has a C-20 input cord and 7 x C-13 receptacles. HP Fixed Cord Extension Bars NOTE: Each extension bar has a C-20 input cord and 7 attached 13 inch C-13 power cords for use with 1U servers NOTE: Extension bars may be used with any HP PDU that has C-19 outlets AF500A 351655-B21 DA - 12857 Worldwide Version 8 June 20, 2011 Page 6

Related Options HP Power Cables HP IEC320-C14 to C13 10A/4.5ft/1.37m/ 15 PDU Cable 142257-007 HP IEC320-C14 to C13 (10A/4.5ft/1.37m) PDU Cable 142257-006 HP IEC C13-C14 Cable Option Kit 142257-B28 HP 1xC19-C120 16A 2.5m Cable 295633-B22 HP 2m 16A C19-C20 Redundant Jumper Cord AF574A HP 1.2m 16A C19-C20 Redundant Jumper Cord AF575A HP IEC320-C20 Power Cord E7798A NOTE: For more information on HP power cords please go to: ftp://ftp.compaq.com/pub/products/servers/proliantstorage/power-protection/powercord-option-kits.pdf HP Care Pack Services HP Install Universal Power Supply 6KVA or Greater Service U4696E DA - 12857 Worldwide Version 8 June 20, 2011 Page 7

Technical Specifications Electrical Output Power Output R8000/3 NA R8000/3 INTL R12000/3 NA R12000/3 INTL 8kVA/8KW @ 208v 3F Delta 8kVA/8KW @ 400v 3F Wye Nominal output frequency 50-60 Hz auto-detection (Normal mode) 50 or 60 Hz (Battery mode) Output Frequency Variation Output overload Voltage wave form Surge suppression Noise filtering 12kVA/12KW @ 208v 3F Delta Synchronized (Normal mode) ±0.1 when not synchronized with source (Battery mode) 100 110%: load transfers to Bypass mode after 10 minutes 110 125%: load transfers to Bypass mode after 1 minute 125 150%: load transfers to Bypass mode after 5 seconds >150%: load transfers to Bypass mode after 300 ms Sine wave; 2% THD with typical PFC load High-energy 6500 A peak MOVs and line filter Output Connections One NEMA L15-30R One IEC309 516C6 (16A) Two NEMA L15-30R 12kVA/12KW @ 400v 3F Wye Two IEC309 516C6 (16A) Electrical Input Voltage Range 200-240 v 3F Wye 380-415v 3F Wye 208v 3F Wye 380-415v 3F Wye Nominal voltage 208v 3F Wye 400v 3F Wye 208v 3F Wye 400v 3F Wye Nominal frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Frequency range 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz Efficiency 97% @ 40-100% load Input connector NEMA L21-30 (30A) 97% @ 40-100% load IEC309 516P6 (16A) 97% @ 40-100% load IEC309 560P9 (60A) 97% @ 40-100% load IEC309 532P6 (32A) Operating Temperature Non-operating Temperature Relative Humidity Operating Altitude Transit Altitude Heat Dissipation Audible Noise Leakage Current Surge suppression Operating Temperature Optimal battery performance -13 F to 131 F (-25 C to 55 C) Operating 50 F to 104 F (10 C to 40 C) 41 F to 77 F (5 C to 25 C) 5% to 95% non-condensing Up to 3300 ft (1,000 meters) above sea level; up to 6600 ft (2,000 meters) with 1% derating per +330 ft (100 meters) Up to 49,212 ft (15,000 meters) above sea level 1266 BTU/hr maximum at 100% rated load (High Efficiency mode) Less than 50 dba at 1 meter (Normal mode) Less than 55 dba at 1 meter (Battery mode) < 3.5 ma ANSI C62.41 Category B3 Safety Conformance UL 1778 4th edition; CSA C22.2, No. 107.3 EN and IEC 62040-1-1 UL 1778 4th EN and IEC edition; CSA 62040-1-1 C22.2, No. 107.3 DA - 12857 Worldwide Version 8 June 20, 2011 Page 8

Technical Specifications EMC (Class A) FCC Part 15 EN 62040-2 FCC Part EN 62040-2 Unit Dimensions (WxDxH) 14.4 x 26 x 10.3 in (441 x 660 x 261 mm) 6U Shipping Dimensions 25 x 38 x 46 in (635 x 965 x 1169 mm) (WxDxH) Unit Weight Without batteries 135 lb (61 kg) With batteries installed 307 lb (140 kg) Shipping Weight 400 lbs (182 kg) Extended Runtime Module Unit Dimensions (WxDxH) 17.2 x 26 x 5.2 in (438 x 660 x 131 mm) 3U (ERM) Shipping Dimensions 47.25 x 31.5 x 37 in (1207 x 800 x 940 mm) (WxDxH) Unit Weight 170 lbs (77 kg) Shipping Weight 185 lb (84 kg) Estimated Backup Times Chart (Minutes) R8000/3 Load % With Internal Battery With 1 ERM With 2 ERMs With 3 ERMs With 4 ERMs 20% 55 118 183 253 329 50% 23 46 69 94 120 80% 12 27 41 55 70 100% 9 21 32 43 54 Estimated Backup Times Chart (Minutes) R12000/3 20% 37 78 119 163 211 50% 13 30 44 59 76 80% 6 17 26 34 44 100% 5 12 20 27 34 NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions. Environment-friendly Products and Approach End-of-life Management and Recycling Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. DA - 12857 Worldwide Version 8 June 20, 2011 Page 9

Technical Specifications Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. DA - 12857 Worldwide Version 8 June 20, 2011 Page 10