REGAL Series RH40. Handheld Ultrasonic Flow & BTU Meter. Applications. Features and Benefits

Similar documents
Applications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement

Applications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement

DMTFP Portable Ultrasonic Flow Meters

Clamp-On Transit Time Ultrasonic Flow Meters

ThermoPro TM Series TP10

Ultrasonic Heat Flow Meters

Series DMHF Heat Meter

EQUITY SERVICES & SOLUTIONS CO.,LTD. cono Flow

Applications. Features And Benefits. Ultrasonic Transit-Time Flowmeter For Permanent Installation

Ultra Sonic Flowmeter DATASHEET

Technical Specifications

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

Regd.off: # Venkateshwara Nagar Colony Meerpet Moulali Hyderabad A.P.India Tel: / /

DCT7088 Portable Digital Correlation Transit Time Flowmeter

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

Ultrasonic Flow Meter Brochure

ULTRASONIC FLOW METERS (Series MU) MAXIFLO TM. Seil Enterprise Co.

TransPort PT878. Panametrics Portable Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

TransPort PT878 Panametrics Portable Ultrasonic Liquid Flowmeter. GE Sensing. Applications. Features

OPERATING INSTRUCTIONS

OPTISONIC 6400 Technical Datasheet

Handheld ultrasonic flowmeters

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Applications. Features & Benefits ULTRASONIC WATER METER

THE TECHNOLOGY BEHIND THE MEASUREMENT

DIN-Rail Mounted Ultrasonic Flow Meter

Data sheet deltwavec-f

KATflow 200 Hand-Held Clamp-On Ultrasonic Flowmeter

Aysix 200 Hand-Held Flow Meter

Smart flow meter. Smart phone. Smart idea.

Series TFXP PORTABLE TRANSIT TIME FLOW METER FEATURES

Flow Measurement Applications

Specialists in Ultrasonic Flow Measurement

Model Sono-Trak General Specification

TransPort. PT900 Portable Ultrasonic Flow Meter for Liquids. GE Oil & Gas

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER. User s Manual FOR LIQUID FLOW. Industrial & Military Instruments. January 2016

SOLUTIONS ONICON. Innovative HVAC Flow and Energy Measurement Solutions PRECISE, RELIABLE, TRUSTED

Portable Dual Frequency Doppler Flowmeter

Advanced Test Equipment Rentals ATEC (2832)

TransPort. PT900 Portable Ultrasonic Flow Meter

Purpose of Today s Presentation

Swarm. Real-time corrosion and erosion monitoring system. Non-Intrusive Wall Thickness Monitor

Flow measurement in open channel. Portable Area-Velocity Mainstream EH7000 P. Ultrasonic Area-Velocity Flow meter MAINSTREAM 7000

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

NF770 Temperature Compensation Liquid Flow Computer

U L T R A S O N I C F L O W M E T E R

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter

SITRANS F flowmeters SITRANS F US

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

CONVERTER MC406. Electromagnetic flowmeter. The battery powered electronic converter DS400-1-USA

TITAN S8. Transportable Data Acquisition Device. Product Brochure EN

Intelligent sonic online flow measurement. Pouriya Niknam Piramoon System Qeshm, Iran

Flow Measurement SITRANS F US Clamp-on

PipeMonit Swarm. Real-time corrosion and erosion monitoring system. Non-Intrusive Wall Thickness Monitor

2 CLASS AMR READY INVONIC H DATA APPLICATION HEAT METERING. approved ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50

PanaFlow Gas Meter System

Track fluid flow from outside the pipe

UTM10 Series Ultrasonic Transit-time Flowmeters

Switch on / off. For switching off please press button for approx. 5 sec.

Level and Flow Measurement. Flow Pulse

General Specifications

The Micronics U-100 U-100 GPRS. At the heart of your modular clamp-on flow and energy monitoring solution. Local Displays. CalecST Heat Meter

Flow Measurement SITRANS F US Clamp-on

Purpose of Today s Presentation

Non-intrusive Flow and Energy Metering With Wireless Solution

uniquely Clear view NEW Wohler VIS 350 Video inspection, position indicator, home function and locator The Measure of Technology

RHE26. Rack/Panel/DIN Rail Mount Multifunction Coriolis Flow Transmitter

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

Spectrum 50DL. Warranty 5 Yr. Materials & Workmanship 5 Yr. OER Register. Standards AWWA C NSF-61/372. Spectrum 50DL (1 )

Precision hand-held pressure indicator Model CPH6400

Flow Meter. The most flexible flow meter

Series TFXD FIXED LOCATION TRANSIT TIME FLOW METER FEATURES

Spectrum 175D. meter performance with no maintenance.

B.M LIMENA (PD)

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Flow Measurement SITRANS F US Clamp-on

Level and Flow Measurement. Flow Pulse

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Conductivity Transmitters

>> Ultrasonic Flow meter User Manual

Remote Asset- Integrity Monitoring

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

ENERGY METER AND DATA MANAGEMENT

Technical specification FLUXUS F501. Ultrasonic measurement of water flow

S 551 COMPRESSED AIR ANALYZER

Spectrum 500D 3/4 gpm Functional Specifications Physical Specifications Standards Spectrum 500D (3 or 4 )

Entering a Whole New Dimension The ULTRAHEAT XS Heat Meter

MID approval no. DE-08-MI004-PTB004 Date of release

LEVIFLOW Ultrasonic Technology Clamp-On Flowmeter D-Series for Flexible Tubing

CALEC energy master The benchmark in energy measurement

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

Explosion-Proof Gauge Pressure Transmitter

Transcription:

Applications The RH40 handheld unit is the most compact yet powerful flow / BTU meter on the market. The utilization of our proprietary technologies, such as ultrasonic signal processing, signal quality tracking, and self-adaptation as well as high-density electronic design, allows the device to measure liquid flow, temperature and thermal energy from outside of a pipe reliably and accurately. Examples of the applications include: Energy consumption supervision and water conservation management Cooling system and air conditioning/glycol solutions Water, including hot water, chilled water, city water, sea water, and more Sewage and drainage water with small particle quantity Oil, including crude oil, lubricating oil, diesel oil, fuel oil, and more Chemicals, including alcohol, acids, and more Solvents Beverage and food processors Water and waste treatment Power plants (nuclear, thermal & hydropower) heat energy boiler feed water Metallurgy and mining applications (e.g., acid recovery) Marine operation and maintenance Pulp and paper Pipeline leak detection, inspection, tracking and collection Water distribution network monitoring Features and Benefits Accurately measures energy and flow using non-intrusive technology. Capability of measuring bi-directional flow/energy Ease of use and fast installation Able to measure on a very wide pipe size range, from 3/4 up to 120 Ergonomic design, allowing the main unit to be held and operated with one hand Signal quality tracking and self-adaptation for robust performance Suitable for pure liquids and liquids with some particles. No dependency on conductivity Suitable for all commonly used pipes Rechargeable battery for 8 hours of operation Self-explanatory user interface. Step-by-step Quick Start guidance Built-in large data logger PC software for data download and real-time data acquisition Serial interfaces for PC link DS-RH40-1501-Rev.6 Spire Metering Technology LLC,249 Cedar Hill Street, Marlborough,MA 01752,USA Tel +1-978 263-7100 / 1-888 738-0188(toll-free) Fax +1 978 418-9170 sales@spiremt.com www.spiremt.com

Applications self-explanatory and simple to follow. The unique strap-on fixtures for both the ultrasonic transducers and the temperature sensors make the installation hassle free. No special skills or tools are required. The RH40 handheld unit has a rechargeable battery allowing the user to measure flow and energy for more than 8 hours. A built-in data logger memory of up to 2GB gives the user the flexibility of using the meter for data-logging and data-analysis. Our innovation never stops! This Handheld Ultrasonic flow and BTU meter, RH40, is a revolutionary portable meter with numerous features and powerful functions. It is the most compact and mobile flow/btu meter on the market. The meter is completely portable and utilizes clamp-on sensors to effectively perform non-invasive flow and thermal energy measurements. This yields major advantages. For example,there are no pipeline disturbance, no pressure loss, and most importantly no process interruption. RH40 is the best choice for flow survey, meter verification, pump checking, HVAC and energy balancing, energy auditing, facility management and other demanding flow and energy monitoring applications. Using the patented signal processing technology that has demonstrated its robustness and data measurement repeatability, the portable meter offers a highly accurate and reliable measurements. The meter user interface is 02

Measurement Principle The Regal Series flow and energy meters are based on the transit-time measurement principle, where the system utilizes a pair of sensors (A and B in figure below) that function as both ultrasonic transmitter and receiver. The sensors are installed on the pipe wall, either clamped on the outside of the pipe or inserted into the pipe at a specific distance from each other. The flow meter operates by alternately transmitting and receiving a coded burst of sound energy between the two sensors and measuring the transit time it takes for sound to travel between the two sensors. The difference in the transit time is directly related to the velocity of the liquid in the pipe. The flowrate is then calculated based on the transit-time difference, the geometry of the pipe and the fluid dynamics formula. The sensors are commonly mounted with the Z-method or the V-method. With the Z-method, the two sensors are installed on opposite sides of a pipe. This method offers a shorter sound path, thus, better signal strength. It is often used for large size pipes where signal strength is more important. With the V-method, the two sensors are installed on the same side of a pipe. The sound path is doubled, thus, the measurement accuracy is better. This method is often used for small and medium size pipes. (a)z-method (b)v-method 03

Typical Transducer Installation There are several types of transducers you may choose for your application.rs,rm and RL transducers have mounting rail,thus,are easy to install(figure(a)).you may need to use clamping strap to tie the mounting rail to the pipe if the magnet on the rail does not work with the pipe.all the other types of transducers do not feature mounting rails. Again,the supplied clamping strap can be used to mount the transducers(b). (a) (b) The site of the transducer installation is very important. Here are some recommendations for selecting the right site: In order to achieve good accuracy, it is recommended to have 15D straight-pipe run: upstream 10D and downstream 5D, where D is pipe diameter If there is a valve upstream and the valve is not fully open, it could generate flow disturbance. A longer upstream straight pipe run is recommended If there is a pump upstream, we recommend to have 25D straight pipe run If pipe is vertical, make sure the flow is going upward, not downward. Downward flow could have air gaps if the flow is free fall If pipe is horizontal, make sure the pipe is FULL and ensure the transducer is installed on the side of the pipe, not on the top or bottom of the pipe 04

Specifications: flow/energy transmitter (main unit) Design Energy Measurement Flow Velocity Range Flow Accuracy Temperature Accuracy Repeatability 0.5% Portable Measure Energy rate and energy total. Optional dual RTD is required. ± 32 ft/s, bi-directional. For pipe 6 : ±1% of reading ±0.03ft/s in velocity* For pipe <6 : ±2% of reading ±0.03ft/s in velocity* Temp: ±1.8 o F Delta Temp: ±0.18 o F with matched RTD sensors Response Time 0.5s. Configurable between 0.5s and 99s. Display/Keypad Units Physical Quantity Totalizers Output Recording Data Logger Communication Interface Software Pipe Size Range Pipe Material Liquid Type battery Liquid Temperature Enclosure Protection Dimensions Weight Power source LCD with backlight. 4 x 16 letters. 5 x 4 tactile-feedback membrane keypad plus utility 4 keys. Displays instantaneous Energy rate/total, flow rate/total (positive, negative and net), velocity. English (U.S.) or Metric Volumetric flow rate, total flow, velocity, temperature, BTU Positive totalizer, negative totalizer, net totalizer, manual totalizer. 4-20mA Optically isolated Open Collector Transistor output (OCT) for frequency and pulse. Automatically records the daily total of the last 128 days, the monthly total of the last 64 months and the yearly total of the last 5years. Built-in data logger (2GB space) for recording Energy, velocity, flow, status, and more >150,000 measured values. RS232. Supports the MODBUS protocol. PC software for data logger download and real-time data acquisition. 3/4" - 120", depending on transducer. All metals, most plastics, some lined pipes. Most liquids with fewer than 1% suspended particles < 75um in a full pipe. Ion-Li up type to 8 hours 32 o F - 176 o F or 32 o F - 312 o F, depending on transducer type Handset: Plastic with anti-shock protection 1.2 lbs with batteries IP54 For handset: 8 x4 x1.5 For carrying case: 21 x17 x6.5 Weight Handset: 1.2 lbs with batteries Carrying case: Aluminum alloy protective case. Suitable for normal and harsh environment Carrying case: 15 lbs approximate 3 AAA Ni-H built-in batteries. When fully recharged, it will last over 8 hours of operation. *Note: Under reference condition and velocity should be above 1ft/s. Flowrate is calculated by multiplying velocity with the inner cross-section area of the pipe. 05

Price List Ffor RH40: R H 4 0 BTU Measurement: N) No Y) Yes Flow Transducer: 0) No flow transducer (You must order flow transducer separately to make a complete system) 1) For pipe size ¾ - 3 standard temperature (THC-RS2 transducer) 2) For pipe size 3 28 standard temperature (THC-RM transducer) 3) For pipe size ¾ 28 standard temperature (THC-RS2 and THC-RM transducers) (Value package) 4) For pipe size ¾ 120 standard temperature (THC-RS2, THC-RM and THC-RL transducers) 5) For pipe size ¾ - 3 high temperature (THC-RS2HT transducer) 6) For pipe size 3 28 high temperature (THC-RMHT transducer) 7) Other, please specify Example: RH40-Y-3. Standard handheld ultrasonic BTU meter package for pipe sizes from ¾ (DN20) to 28 Features include: Main unit (handset) THC-RS2 2MHz clamp-on transducer with mounting rack (magnetic) THC-RM 1MHZ clamp-on transducer with mounting rail (magnetic) Transducer cable 15ft (5m) RTD temperature sensors in pair surface mount type Acoustic couplant Battery charger Terminal cable Carrying case PC software 3-point calibration certificate User s manual Clamping stretcher 06

Optional and Replacement Parts Model Picture Description PN#: THC-RS2 Small size transducer ( mounting rack with magnetic) For pipe size: ¾ - 3 Temperature: 32 F - 176 F PN#: THC-RM PN#: THC-RS2HT PN#: THC-RMHT PN#: THC-RL PN#: TH-CBL PN#: TH-CBLEX PN#: PT100CL PN#: UT850 PN#: HA-BP PN#: HA-BC Medium size transducer (mounting rack with magnetic) Pipe size: 3-28 Temperature: 32 F - 176 F Small size, high temperature transducer Pipe size: ¾ - 3 Temperature: 32 F - 312 F Medium size, high temperature transducer Pipe size: 3-28 Temperature: 32 F - 312 F Large size transducer Pipe size: 12-120 Temperature: 32 F - 176 F Transducer cable Standard 15 cable for flow transducer Transducer cable extension Extension cable, 15, for handheld flow transducer Clamp-on Temperature Sensor RTD pair PT100 Thickness gauge Ultrasonic thickness gauge for measuring pipe wall thickness on plastic and metal pipes, ranging from pipe size 1 120 Battery pack For replacement only Battery charger For replacement only PN#: HA-CC Hard Plastic carrying case PN#: TH-CPLT-G PN#: TH-CLP2 Acoustic couplant Lithium grease acoustic couplant for transducer installatio Clamp Clamping Stretcher for transducer mounting 07

PC Software: StufManagerTM is a Windows-based PC software aimed to facilitate the use of and to explore the full potential of the RH40 handheld flowmeter. StufManagerTM software makes it very easy to connect a RH40 device to a PC USB connection. For those users with limited technical expertise, this software is essential as its ease of use saves both time and money. With StufManagerTM software, you can download data from the data logger inside the flowmeter directly to your computer. You can format the downloaded raw data into standard formats with a simple click of the mouse. You may then save the data to your computer hard drive and use Excel or other spreadsheet software to manipulate the data at a later point. StufManagerTM software allows you to acquire the flowmeter data in real-time and display the data on a graphical interface. You can save the real-time data to your computer easily. Link the RH40 Btu and flowmeter to the computer using Stufmanager. About Spire Metering Technology Spire Metering is a global leader in flow and energy management solutions.through continuous innovation, we transform cutting-edge technologies into affordable, reliable solutions for accurate flow and energy measurement. Spire Metering offers water, heat, electricity and gas meters as well as AMR/AMI solutions. To find out how we can help today, please tell us about your application. 08