EC700. Pulses concentrator. User instructions

Similar documents
COUNTIS ECi2 ECi3. Operating instructions Multi-utility pulse concentrator F GB D I NL E P

COUNTIS Ci Notice d utilisation GB Operating instructions Bedienungsanleitung NL Gebruiksaanwijzing

SM210 RS485 - JBUS/MODBUS for SM102E. User instructions

Module with RS485 communication option for

COUNTIS E05. Single-phase energy meter Direct - 40 A M-BUS. Instruction manual. en/countis-e0x

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

DIRIS Digiware DC Measurement and monitoring system for DC electrical installations

Programmable Relay ZEN V2 Units

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

MDC-20. Maximum Demand predictive Control. Description

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Operating instructions. Speed monitor D / / 2014

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

Power Meter PowerMonitor 500

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

Multifunction Transducer MT440

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Technical Specificaions. kwh Energy Meter

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

COUNTIS ATv2/ATiv2 GB

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

CDD4 Duct Carbon Dioxide Transmitter

MIC-2 MKII, Multi-instrument DATA SHEET

RS 485 Mini Modbus 1AO

CEM-C6 INSTRUCTION MANUAL (M187B B)

Operating instructions. Switching amplifier DN0210 DN / / 2015

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

MIC-2 Multi-instrument DATA SHEET

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

MPR-4 SERIES NETWORK ANALYSER USER MANUAL

Neon pr. ph/ ORP measurement. Applications. Description

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

Carbon Monoxide Sensor - ModBus

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

BCM2 Series Branch Circuit Monitors Quick Setup Guide

mark150s mark150/485s DDC controllers Summary

Electronic earth leakage protection relay

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Products no longer available

DIRIS D-30 DIRIS Digiware D-40 DIRIS Digiware D-50 Control and power supply interface

Voltage Transducer UMT516 / MT516

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

RS485 MODBUS Module 8I8RO

CDD Carbon Dioxide Transmitter

Technical Specifications. Dual Source kwh Energy Meter

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

DIRIS Digiware D and C Communication and control power interfaces

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

ATS CONTROLLER OPERATING MANUAL

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

CDD4 Series Room CO2 Transmitter Installation Instructions

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

RS485 MODBUS Module 8I8O

EngyVolt RV12 and RV15

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Operating instructions. Standstill monitor A / / 2011

RS485 MODBUS Module 6RO

DIRIS B-10 & B-30. Multifunction meters and associated current sensors INSTRUCTION MANUAL. en/diris-b

Operating Instructions

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Data Collecting Device. ProData. Operating Instructions. Dip Switches. Interface. Mode RS485- PT LON. Interface Analogue Input 0-20mA

PM Series Power Meter

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

RXTP ROOM TEMPERATURE

SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0

LBVR1718. Description. Features channel paperless recorder

02/11/2015

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

RXTH DUAL ROOM SENSOR / SWITCH

PXR Series Advanced Self-Tuning Temperature and Process Controllers

Installing and Configuring Rialto Analytic Appliances

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

DTM Distributed Transmitter Monitor

Transcription:

EC700 Pulses concentrator User instructions

Contents Hazards and warning... 3 Initial checks... 3 Introduction... 4 Jbus/Modbus Communication... 5 Installation... 6 Configuration... 9 Use... 9 Programming... 10 Technical Characteristics... 12 Troubleshootig... 13 2

Hazards and warning Qualified personnel and correct operation The equipment described in this document may only be installed, commissioned and operated by trained, qualified personnel. Failure to follow the procedures given in these instructions does not imply liability on the part of the manufacturer. Standards, directives, legal provisions and local regulations must be complied with. Risk of electrocution, burns or explosion before working on the device, isolate all dangerous live components, always use an appropriate voltage detection device to confirm the absence of voltage replace all components, doors and covers before reconnecting this device to the power supply always use the appropriate specified voltage to supply this device. Failure to comply with these precautions could result in serious injuries. Risk of damage to the device Ensure the correct : voltage across the AUX SUPPLY power supply terminals, 110-400 Vac / 50-60 Hz voltage across the OUTPUT relay, 250 Vac or 30 Vdc. Initial checks For the safety of personnel and equipment, it is essential to read all of these instructions before using the device for the first time. Confirm the following points upon receipt of the package containing the EC700 : the packaging is in good condition the product is in good condition the device part number matches that specified on your order the contents of the package : - 1 product - 1 resistance for line impedance - 1 mini CD - 1 quick start instructions. SM102E 3

Introduction The EC700 is a pulse concentrator equipped with 7 digital inputs (logic or pulse signal) and an RS485 connection to the JBUS/MODBUS protocol. It centralises and memorises pulses or logical signals in the output of electrical, gas, heating oil, water and compressed air meters or measurement units in order to : send them via the RS485 communication output to a remote energy management system (ENERGY REPORTING ) display a large number of these items on its local display screen for direct reading of information generate event alarms (1 dedicated relay output). The EC700 enables advanced customisation of all items, facilitating direct reading of information concentrated in this way: metering unit per input: kwh, m³ currency / input :, K,, $ logical inputs (NO/NF, delay) or pulses (weight, synchronisation source, time intervals for load graphs) logical output: configurable alarm, NO/NF and time delay. It is also possible to display, at any time : the physical status of each of the 7 digital inputs (contact open or closed, pulses present or not), the physical and functional status of the logical output (contact open or closed, output active or inactive), the status of 5 customisable events: date, activation time, duration, type (logical, threshold, or combination of 2 events), severity (4 information levels) the relative value (%) and absolute value (in the chosen unit) of the 2 analog inputs. The communication interface of EC700 is 2-wire RS485 type using JBUS/MODBUS protocol and enables : remote access to all information produced by pulses concentrators units, above and beyond that displayed on its screen (cf. application note or JBUS/MODBUS table), this device to be operated from a PC or programmable logical controller (API/PLC). This product can be configured locally (PROG menu) or by remote communication. The device has the following functionalities, with direct reading on the display and values saved to memory: total and partial metering in the chosen unit with currency equivalent daily, weekly, monthly or annual metering partial metering from the last synchro trigger (in progress) metering on customised trigger (Perso) for each input, it memorises pulses by integrating them over a programmable interval (from 1 to 60 minutes in 1 miniute steps) to reconstitute a load graph. Whatever the chosen integration interval, the load graph is created over a sliding period of 17 days. All information is accessible through JBUS/MODBUS. A: backlight LCD display B and C: keys to scroll through Menu functions (right-left) D: and E: keys to scroll through Menu sub-functions (top-bottom) F: access key for programming functions (PROG) G: LED to indicate communication frame on RS485 port addressed by it MENU B C D E PROG OK F G A 4

Jbus/modbus communication RS485 MEDIA In a standard configuration, one RS485 connection enables 32 UL* to be connected to a PC or PLC over 1200 metres using the JBUS/MODBUS protocol. *1 UL = 1 EC700. Recommendations An LIYCY type shielded twisted pair must be used. In a disturbed environment, we recommend using a shielded twisted pair with general LIYCY-CY shielding. If the distance is greater than 1200 metres and/or there are more than 32 devices, it is necessary to connect a repeater (1 channel) or a spark arrester (2 channels) to enable the connection of additional device (with communication interface over more than 1200 metres). JBUS/MODBUS PROTOCOL The JBUS/MODBUS protocol operates on a master/slave structure: Reading (Function 3), Writing (Function 6 or 16), broadcast option at address 0. The communication method is RTU (Remote Terminal Unit) with hexadecimal characters comprising a minimum of 8 bits. JBUS/MODBUS TABLE The communication tables are available on the CD-Rom supplied with the EC700. Important It is essential to connect a resistance of 120 ohms to the 2 ends of the connection; this can be found in the product packaging. Other solutions are available (modem, fibre optic, etc.); please ask for details. 5

Installation The EC700 meter can be mounted on a 35 mm rail. It must be used inside electrical cabinets. 1 1 Aux. 110 400 Vac 120 300 Vdc 2 Fus. 0.5 A gg / BS 88 2A gg 3 250 Vac 3A Relais 30 Vdc/1A 3 2 7 14 16 20 22 In7 Output Aux supply MENU PROG OK Vout In1 In2 In3 In4 In5 In6 + _ 1 2 3 4 5 6 9 8 RS485 + _ 13 15 17 R=120Ω RS485 0.14 / 2.5 mm 2 0.14 / 2.5 mm 2 5 mm 0.6 Nm 0.2 / 6 mm 2 0.2 / 4 mm 2 8 mm 6

Connecting logical inputs Internal polarisation, cable length 1000 m. max, 1.5 mm² min. 7 14 16 20 22 In7 Output Aux supply MENU PROG OK Vout In1 In2 In3 In4 In5 In6 + _ 1 2 3 4 5 6 9 8 RS485 + _ 13 15 17 External polarisation, cable length 1000 m. max, 1.5 mm² min. 7 14 16 20 22 In7 Output Aux supply + - DC AC Stabilized power supply 10-30 Vdc MENU PROG OK Vout In1 In2 In3 In4 In5 In6 + _ 1 2 3 4 5 6 9 8 RS485 + _ 13 15 17 7

Notes 8

Configuration To enter configuration mode, press the PROG key for 3 seconds. You are asked for a code: - Normal user: code 1000 (default value, configurable number): all parameters can be modified EXCEPT those locked by the code 6825. - Advanced user: code 6825 (not configurable): allows access to all parameters accessible with the code 1000, as well as sensitive "maintenance" parameters: factory settings and Input Reset. After 1 minute if a key is not pressed = automatic exit from programming mode. The configuration is not saved. To save and quit programming mode, press and hold PROG. Use The screens presented in the USAGE / PROGRAMMING charts are not all visible: their display depends on the version of your EC700 and their configuration. Total / Partial Log. Input Input / State / Pulse Alarm 1 Type / Sever / State Date / Time Total and partial metering Digital input: logical input, physical status and presence of pulses Event 1 information: type, seriousness and status Date and time setting Day / Week Daily and weekly metering Dig. Stat / Phys/ Func Inputs 1 to 7 if logical programming Alarm 1 Date / Duration Date and time of start of event 1 and duration if completed Top Synchro Last Top Date and time of last sync signal Month / Year Monthly and yearly metering Output Dig. Stat / Phys / Func Logical output and functional status idem Alarm 2 to Alarm 5 Information Name / Ver / SN Name, software version and product serial no. OnGoing / Custom Metering since the last sync signal and personal metering Tot / Part Cost Equivalent in currency of Total and Partial metering Idem Input 2 to Input 7 9

Programmation Hold down for 3 seconds. The screens presented in the USAGE/PROGRAMMING charts are not all visible : their display depends on the version of your EC700 and their configuration Mode Inputs Cost Currency Output Src / Type / Delay Alarm 1 Mode / Sever Pulse meter, logical status or deactivated Currency setting Logical output setting: source of control, NO/NC type and time Mode: logical, analog, combination or deactivated Type / Delay Enable / Cost Alarm 1 Src / Type NO/NC type and time Currency conversion activation Logical alarm setting: source and type Unit / Weight Pulse weight and unit Idem Input 2 to Input 7 Alarm 1 Src 1 / Src 2 / Type Setting of combination alarm: source 1, source 2 and type Synchro / Integ Alarm 1 Src / Type / Hyst Sync source and integration time Setting of analog alarm: source, type and hysteresis Reset/ Partial/ Custom Alarm 1 Low / High Pulse metering reset Setting of analog alarm: low or high limit Idem Input 2 to Input7 Idem Alarm 2 to Alarm 5 MANUAL mode This mode enables manual configuration of all communication parameters JBUS/MODBUS: address, speed, parity, stop bit. AUTO mode This mode enables automatic configuration of most of the communication parameters (speed, parity, stop bit). Only the communication address for the EC700 has to be entered. The mode only functions under the following conditions: Communication speed between 9600 and 38400 baud. JBUS/MODBUS frame format: - 8 bits + 2 stop + no parity - 8 bits + 1 stop + parity. 10

Modification with code 1000 Modification with code 6825 Com Modbus Adress / Mode Mode and address setting Date Day / Month / Year Day, month, year setting Language English Language selection Maintenance Factory Cfg / Action Reset to factory settings Com Modbus Baudrate / Stop / Parity Speed, stop and parity setting Hour Hour / Minute / Second Hours, minutes, seconds setting Lock Code 1000 Password selection, used for modifying the config. Maintenance Input Reset / Src / Act Input reset Display Contr./ Backl./ Timeout Contrast, brightness, standby setting 11

Technical characteristics Descriptions Min Max Units Comments Auxiliary power supply AC voltage 110 400 Vac +/-10%, 45/65 Hz, DC voltage 120 300 Vdc +/-10%, 5 VA Climate Ambient temperature -10 55 C IEC 60068-2-1/ -2-2 Storage temperature -20 70 C IEC 60068-2-1/ -2-2 Ambient humidity 95 % RH IEC 60068-2-30 Vibration Vibration 2 G IEC 60068-2-6 10 to 100 Hz Case Dimensions 73x90x67 mm LxWxH Weight 215 g Protection index of enclosure IP51 / IP20 Front/Case Electrical safety Cat. Install. /degree of pollution III / 2 IEC 61010-1 ed. 3 (300 Vac Ph/N) Updating period Display 1 Sec RS 485 communication 0,5 Sec Digital inputs Direct voltage 10 30 Vdc Terminal 8 reference Current 2 15 ma According to IEC 62053-31 Class B Line length 1000 m Min. section 1.5 mm² (#16AWG) Pulse duration 30 ms max. 16 Hz Power consumption per input 0,4 VA Internal digital input polarisation power supply Voltage 10 15 Vdc Max. 35 ma Relay output Set-up (contact setting) Mechanical strength AC breaking 1 contact (NO, NF) 10 5 cycles 250 Vac / 3A DC breaking 30 Vdc /1A RS485 bus communication (JBUS/MODBUS protocol) Line length 1200 m Number of equipment 32 2 shielded wires + half duplex Modulation speed 9.6 K, 19.2 K, 38.4 Kbds 14

Troubleshooting Device not switched on Check the power supply cable 110 400 Vac or 120 300 Vdc between terminals 20 and 22, if there is voltage present and the device does not switch on, please return the device to us. Faulty communication Check configuration in MANUAL mode: address, speed, parity, stop bit (p.10) and cabling (p. 5). The meter does not advance incrementally Poor connection Go to the to 7 (p. 9) Connect the input to be tested to terminal + 51 (p. 7) to verify that the "pulse detected" pictogram changes state correctly. EC700 complies with the following european directives: - Electromagnetic compatibility directive, no. 2004/108/EC (2004/12/15) - Low voltage directive, no. 2006/95/EC (2006/12/12) Device fully protected with double insulation. 15

Hager 01.2012 OCOM 112132 540304A_GB www.hager.com 6S5093-01a