Processor ATP1. Product Sheet

Similar documents
DIN-Rail Mounted Ultrasonic Flow Meter

USER MANUAL. V1.0.2, Rev A

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Uncompromising performance...

Welcome to the NMEA Gateway session. San Diego. Wednesday Sept 25 8:00am Thursday Sept 26 1:30pm

NF770 Temperature Compensation Liquid Flow Computer

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

NF760 Batch Controller

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Neon pr. ph/ ORP measurement. Applications. Description

Technical specification Marine Master Clock

Advanced Wind Turbine Concept. Mita-Teknik. Data Sheets. Condition Monitoring Mita-Teknik. All rights reserved

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

EMTRON AUSTRALIA EMTRON ECU OVERVIEW

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

SAILMON SYSTEM NEXUS FDX INTERCONNECT MANUAL. Sailmon to Nexus interconnect Manual V1.0 Page 1

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Contents. Temperature & Process Measurement Indicators Setup Guide

Innovative hardware...

Introduction to latest innovation in advanced industrial instrumentation UNIT 6 BASIC INSTRUMENTATION

Vibrating Wire Instrument Assembly Guide

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

Data Sheet. QFBR-S01IN001Z Optical Phase Interrogator. Description. Features. Applications

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

Interface Adapter Card. Part Number

Product Brochure PMA KS Multi-function Controller.

An Open Platform for Collecting Data for OpenSeaMap Ulrich Langenbach, Joachim Langenbach

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Hotel Room Controller

Environdata FA ma Converter Guide

HCS1 Three-Axis Helmholtz Coil System

Albatross Control System Installation

world class water monitoring series 42

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

iworx RA-834 Recorder

MODEL ELECTRONIC COMPASS

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz

General information. Display. Supply voltage. Input current. Encoder supply. Output current

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System

Andover ContinuumTM Infinet II

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.4 UK

MAX Modular Analogue Expandable System

Specification for temperature sensor calibration setup

I/O module (Expansion module)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

QFBR-S01IN001Z. Optical Phase Interrogator. Data Sheet. Description. Features. Applications

LAUREL ELECTRONICS, INC.

MFD USER & INSTALLATION MANUAL. (Please check the Downloads section of our website for the latest manual)

Product Specifications

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

OCEAN 7T. Technical presentation (ENGLISH) FURUNO ELECTRIC CO., LTD. All Rights Reserved.

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

BACnet. b3810 Series Local Controllers

Displays Transducers. Displays and transducers

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

Programmable Position Indicators

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner

EDX-10 Series. Compact Recording System

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MODULAR PROCESS AND QUALITY CONTROL SYSTEM FOR MACHINE TOOLS

high performance signal conditioner cards

General information. Display. Supply voltage

General Specifications

GC2000 Generator Controller Power Management and Protection

IQ3/XNC M-Bus Master

TALON Network Manager- 2 & 6 Express

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TM221M16R controller M IO relay

TM258LD42DT4L compact base M I/O - 24 V DC

Tachometer Panel, PE3

User Guide. for TAHOE 8718

TSM1 Infrared Data Logger

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

A New Approach to Tank Level Measurement Using Absolute Pressure Sensors

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

SERIES E L I T - -J. Authorized distributor in Australia:

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

ATV1200A kv kva

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

TM258LD42DT4L compact base M I/O - 24 V DC

CALEC energy master The benchmark in energy measurement

Barracuda NG Firewall F400 Revision B

Transcription:

Processor ATP1 Product Sheet Overview A whole step forward in instrument performance Use any mixture of existing (B&G) and new (A+T) displays Can use existing Fatnet wiring to keep upgrade costs down Ethernet for new cabling, simple and powerful Duel Fuel bus approach allows gradual upgrade 24/7 telephone support Architecture The heart of the system is the ATP1 Processor and motherboard Based on Intel Atom CPU running at 1.46 GHz with 4GB of flash drive and GB RAM Navigation computation cycle 50 Hz (upgradeable to 100Hz) Inputs/outputs:- 3 Serial/NMEA0183 input and 2 output (selectable baud rates) 4 Analogue channels with 5V & 12V reference supply 2 separate alarm relays (e.g instruments and MOB) 1 NMEA 2000 compatible for sensor input and data output 1 Fastnet connection to support existing B&G displays and sensors 1 Ethernet connection for external computer 1 Ethernet connection for A+T BUS All configuration and viewing of internal calculations by websocket on connected computer Then separate interface boards are added:- Speed & Depth Wind Analogue Loadcell These communicate on a dedicated proprietary Ethernet backbone which runs at up to 100Mbps (note this is 400 times faster than NMEA2000) Integral heel sensor and barometric pressure 2017

Performance ATP1 Performance The initial release outlined below is aimed at the upgrade market from B&G H2000 and H3000 systems and for new yachts for which this level of performance is appropriate. A higher specification system will be released in the course of 2018 which will be a significant step beyond existing performance systems such as WTP2 and WTP3. Fast boot time, less than 15 seconds from power on to full function Websocket connection to any computer for all settings, configuration and monitoring of internal computations No limit to number of displays that can be connected on system and no practical length limitation on cabling Supports any number of external channels from Expedition & Adrena Functions in both True and Magnetic references; internal variation model Integral heel measurement allows for heel compensation of wind and leeway model Enhanced wind calibration tables & well documented computation schema Enhanced current calculations Unlimited Loadcell and analogue channels may be added and individually labelled and configured Integral Barometric pressure sensor; decimal output of pressure and barograph page Custom additions and suggestions welcome Example of Websocket settings and computation page 2017

ATP1 Interfacing & Configuration Speed/Depth Board Supply voltage and input for a pulse log and sea temperature sensor Depth board to drive existing 170 khz transducers. This has settings for minimum depth and gain. Wind Board Supply voltage and input for B&G wind sensors Loadcell Amplifier (DLA2) 1 x Loadcell Amplifier 1 x Analogue Channel with 5v or 12v supply Analogue 4 x additional analogue channels with 5V and 12V supply (each can be configured separately) 1 x 0-20mA isolated current loop (so also 4-20mA industry standard) Configuration A+T provide the Processor in two principal configurations:- A. Stand alone, existing system upgrade ATP1 processor, Speed/Depth board and Wind board in a single enclosure. This is the simplest and tidiest solution when a straight replacement for an existing B&G H2000 or H3000 processor. The sensor cables are already led back to the processor so installation is straightforward. B. Distributed. for new-build or major refit The processor is mounted separately from the interface boards which are in turn mounted close to associated sensors to keep cable runs minimised. The interface boards and displays are linked with the proprietary A+T Ethernet protocol using Power over Ethernet C. Hybrid configurations for large or specialist installations Example configuration drawings are shown on the following pages. 2017

ATP1 Example Upgrade 2017

ATP1 Example New Build 2017