GENESIS64 V10.5 Resolved Issues May 2010
CONTENTS 1 GRAPHWORX64 1 2 ALARMWORX64 3 3 TRENDWORX64 4 4 EARTHWORX 5 5 WORKBENCH64 6 6 FRAMEWORX SERVER 7 7 HYPER HISTORIAN 8 8 INSTALLATION 9 9 LANGUAGE ALIASING AND GLOBAL ALIASING 10 10 LICENSE SERVER AND LICENSE MONITOR 11 11 SECURITY SERVER 12 Copyright 2010, ICONICS, Inc.
1 GraphWorX64 Added the capability to save a username and password in the Web Publishing Wizard. [#6577] Added greater functionality in the GraphWorX3D Camera and the associated views. Users can now indicate which of the saved views they would like to incorporate into their Camera Patrol and alter properties like duration through the Camera Patrol Options dialog. [#7842] Fixed an issue with global aliasing within the Pick Action command in GraphWorX where a load display Pick Action wouldn t send the global alias value correctly. [#5693] The Document Explorer tree can now optionally show Names or Titles of objects. This option can be changed via Preferences\ General Options\ Explorer Text. [#7844] Corrected an issue for elevation bitmaps (used for 3D Terrain primitives) where display corruption could occur if the image was not loaded properly. [#7900] Added a progress bar to GraphWorX Silverlight to indicate when a display is being loaded. [#8899] Resolved an issue with the default GraphWorX Layouts that would cause the subwindows to become fixed in their current positions. Layouts are now functioning properly. [#9022] Resolved an issue with Embedded Windows in GraphWorX where if the Target Name was undefined then GraphWorX would crash. This is no longer the case and does not result in a crash. [#9050] Highlighted potential user confusion when searching for alias values within a display. To search correctly the # (pound) character must be wrapped in square brackets: [#]. The '#' character is a special wildcard character for searches (it means 'any digit'). Therefore, it needs to be wrapped in square brackets in order to be designated as a 'literal' character match instead of a wildcard character match. [#9063] Resolved an issue that prevented local aliasing at the object level. It is now possible to set different local alias values to different instances of the same local alias via objectlevel local aliasing. [#6328] Enabled support for language aliasing within the 3D View s Camera Views so that each Title for each camera view can utilize any data source. [#6396] Enabled an Advanced Mode feature to allow direct editing of a dynamic object s coordinates within the display. This is configurable via the Path > Edit Path Vertex Values in the Dynamic Properties menu. [#6719] Added an angle property to accurately show the angle of any object within GraphWorX64. The property was not previously shown. [#6718] [#6720] [#6828] Fixed an issue where the GraphWorX Configuration Application could hang in memory if the Zoom Enabled property of a display was set to false. The Application no longer hangs in memory due to this issue. [#7098] Resolved a data binding issue when 3D Views with Annotations where copied and pasted in the same display or between layers. Data now remains bound to the Annotations. [#7169] Fixed an issue that prevented the F1 key from being able to perform functions through pick actions. [#7513] [#7583] Fixed the Replace feature in GraphWorX64 so that it will work with data sources in the TrendWorX64 Viewer. [#8764] Resolved an issue in Workbench64 and GraphWorX64 where the quick access toolbar wouldn t save changes. [#8381] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 1
Warning added to alert users that Smart Symbols cannot persist through Save as Silverlight. Smart symbols are changed to groups and a new log file can describe all the changes made in the Save as Silverlight command. [#8316] Fixed issues with the GraphWorX64 Translator to provide a more seamless transition between GraphWorX32 and GraphWorX64. [#3675] Enhanced the display translator to extend to Silverlight Displays. [#6779] Resolved an issue with local aliasing so that when grouped and changed the aliasing works as expected and doesn t overwrite alias values that shouldn t be changed. [#8389] Rewrote the introduction to the GraphWorX64 Help Documentation. [#5383] Rewrote the GraphWorX64 3D topics in online help. [#5382] [#5917] [#5664] Integrated GraphWorX64 Training Manuals into online help. [5384] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 2
2 AlarmWorX64 Resolved a known issue that stopped generation of alarms when a Unified Data Manager (UDM) register was used as the OPC input for an alarm. [#5552] Resolved an issue with the time in the Schedule view that caused the time to render incorrectly. [#7621] Resolved an issue with the sound agents within AlarmWorX Multimedia. [#7641] Fixed an alarm time issue where the time would default to EST. [#7709] AlarmWorX64 OPC DA data is now exposed after being left out of previous versions. [#9008] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 3
3 TrendWorX64 Added a limit to the multiply function: 99 items. [#4631] Resolved an issue with the legend in the TrendWorX64 Viewer that would cause it to behave unexpectedly when set to a Vertical type legend. [#5642] [#5699] [#5897] [#8847] Resolved issues relating to the editing and inserting of pens in the TrendWorX64 Viewer. [#5219] Resolved issues with different plot types that were behaving erratically. [#5698] [#7710] Removed rare overlaps in legend and chart within the TrendWorX64 Viewer. [#5699] Fixed an issue with the TrendWorX64 Viewer in GraphWorX64 that caused it to crash when grouped via GraphWorX64. [#8926] Resolved various rare crashes due to TrendWorX64 running in GraphWorX64 displays. [#5445] Resolved a TrendWorX Viewer issue where historical pens were not visualized correctly with regard to the current time. [#6909] Resolved a missing option to allow a user to select one pen in the detail area of the TrendWorX Viewer and have the range fit the pen that was selected. This option is based on a scenario with multiple pens and just one range showing. [#7502] The TrendWorX Viewer can now show bad or uncertain data with a configurable line style so that a trend will continue to draw and connect good data samples with a specific line. This leaves the trend unbroken and allows a user to see where and when bad data was collected. [#6910] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 4
4 EarthWorX An absolute path issue was resolved that stopped EarthWorX from working on a remote Internet Explorer client of Workbench64 or GraphWorX64. [#4658] [#5677] [#5934] Resolved an issue with web display of EarthWorX where the EarthWorX control would disappear in web clients due to a missing file. [#6593] Added new EarthWorX documentation to the online help. [#5374] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 5
5 Workbench64 Fixed a bug that blocked the Template editor from working correctly. [#9012] Resolved an issue with the region setting of the computer on Workbench start up. [#8298] [#8468] Fixed an issue where the Security Mode would not be reflected in the General tab of the Global Security Settings. [#4251] Resolved an issue in Workbench64 and GraphWorX64 where the quick access toolbar wouldn t save changes. [#8381] In the Unified Data Manager registers the option to Release Tags When Not in Use is by default now checked to avoid slowing performance unnecessarily. [#8497] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 6
6 FrameWorX Server Resolved an issue of improper connection for GraphWorX64 or Workbench Web Clients. [#5723] Resolved an issue that would stop the FrameWorX Server when configuring certain security. [#4864] [#5729] [#5981] A communication issue raised an error when a user tries to write to a Unified Data Manager (UDM) register which has write enabled and has Initial Value Only (Output Tag disabled). This message should not appear as the write action will succeed. This error has been fixed. [#8554] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 7
7 Hyper Historian There is a new SQL Query Engine which solved the known issues in versions v10.02 and v10.5. [#6773] [#4986] [#4988] [#4990] New Hyper Historian archiving solved known issues in the previous versions. [#3448] [#4323] [#9507] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 8
8 Installation Fixed issues with services not being registered correctly within GENESIS64 installation. [#9136] Created Hyper Historian standalone installation. [#8836] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 9
9 Language Aliasing and Global Aliasing Resolved and issue with setting and resetting a global aliasing values at different levels (i.e. machine level and document level). [#9056] Resolved an issue in the code that prevented the Global Aliasing Default Theme Value to be resolved in Silverlight displays. The issue has been fixed. [#7656] [#7657] Resolved an issue that prevented data to be written to a tag that utilized a global alias within the tag name. Users can now use <#alias name#> syntax for writable data sources as well. [#4705] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 10
10 License Server and License Monitor Enhanced licensing experience by providing a new License Utility and a more thorough License Monitor. [#4482] Added Software Licensing. [#8462] [#7333] Resolved a crash issue with the License Monitor when it was minimized to the Windows tray area. [#8311] Fixed an issue where a USB license would sometimes remain undetected. [#4103] [#6402] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 11
11 Security Server Fixed an issue that allowed all actions within AlarmWorX64, EarthWorX, TrendWorX64 and GraphWorX64 after setting restrictions in Workbench64. [#4865] [#5478] Resolved an issue with the automatic login function for the Windows user. [#4437] Resolved missing Application Actions within configuration of security. [#8737] [#4456] Resolved an issue that wouldn t allow replication of a security configuration along with Administrative Domain (AD) replication. This is now possible. [#7655] ICONICS 2010 Resolved Issues Document for GENESIS64 v10.5 12
VISIT US AT WWW.ICONICS.COM ICONICS World Headquarters 100 Foxborough Blvd. Foxborough, MA 02035 Tel: 508 543 8600 Fax: 508 543 1503 Email: info@iconics.com ICONICS Europe Czech Republic Tel: 420 37 718 3420 Fax: 420 37 718 3447 Email: czech@iconics.com ICONICS Asia Australia Tel: 61 297 273 411 Fax: 61 297 273 422 Email: australia@iconics.com ICONICS UK United Kingdom Tel: 44 1384 246 700 Fax: 44 1384 246 701 Email: info@iconics-uk.com France Tel: 33 45 019 1180 Fax: 33 45 001 0870 Email: france@iconics.com China Tel: 86 130 684 86069 Email: china@iconics.com Germany Tel: 49 2241 16 508 0 Fax: 49 2241 16 508 12 Email: germany@iconics.com India Tel: 91 22 67291029 Fax: 91 22 67291001 Email: india@iconics.com Italy Tel: 39 010 46 0626 Fax: 39 010 65 22 187 Email: italy@iconics.com Netherlands Tel: 31 252 228 588 Fax: 31 252 226 240 Email: holland@iconics.com WHY CHOOSE ICONICS? ICONICS, Inc. is a leading provider of award-winning enterprise Manufacturing intelligence and automation software solutions and implementation services. ICONICS solutions deliver real-time visibility into all enterprise operations and systems, helping companies to be more profitable, more agile and more efficient. ICONICS products have delivered value within over 250,000 installations worldwide and have been chosen by more than 70% of the Fortune 1000. 2010 ICONICS, Inc. All rights reserved. Specifications are subject to change without notice. BizViz, GENESIS64, GENESIS32, Hyper Historian and their respective modules, OPC-To-The-Core, OPC-UA-To-The-Core and Visualize Your Enterprise are trademarks of ICONICS Inc. Other product and company names mentioned herein may be trademarks of their respective owners.