XRM-HSSDC2A. High Speed Serial Adaptor Module. User Guide. Version 1.1

Similar documents
XRM-FCN. High Speed Serial Adaptor Module. User Guide. Version 1.2

XRM-CLINK-ADV. Full/Medium/Base Camera Link and Dual ADV212 Adaptor. User Guide. Version 1.0

High Speed Serial Adaptor Module plus Dual JPEG 2000 CODEC

ADC-XMC-BREAKOUT User Manual

FMC-IO68 User Manual Document Revision: th October 2015

ADM-XRC-5LX. PCI Mezzanine Card. User Guide. Version 2.0

ADM-XRC-5TZ. PCI Mezzanine Card. User Guide. Version 2.0

ADC-PCIE-XMC3 User Manual

ADC-PCIE-XMC User Manual

Design Guidelines for 100 Gbps - CFP2 Interface

ADM-PCIE-KU3 Support & Development Kit Release: 2.0.0

ADM-XRC-5T*/6T* Cooling Solutions

cpci-lk02 User s Manual cpci-lk02 user s Manual (Rev 1.0)

Cable Length Description

QSFP+ Passive Copper Cable QSFP-40G-0xC

ADC-XMC-II Revision: 1.0 Date: 17th June 2011

QFPQL002400U QSFP+ Dual Fibre ITU CWDM / 2km / 40 Gigabit Ethernet / 40GBASE-LX4

JPEG2000 Video Compression Multi-Gigabit Serial I/O

QSFP+ 40G MPO MMF 850nm 300m Transceiver AQOMSN85ADLN0669. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

ADM-PCIE-9H7 Support & Development Kit Release: 0.1.1

40G QSFP LR4 optical transceiver with DDM function

40Gbps QSFP SR4 Optical Transceiver Module

ADM-XRC-II Pro (ADM-XP) Hardware Manual

Genesys Logic, Inc. GL831A. SATA / PATA Bridge Controller. Datasheet

40Gbps QSFP+ CR4 Optical Transceiver Module. Product Specification

cpci-lk03 User s Manual cpci-lk03 user s Manual (Rev 1.0)

QSFP+ Copper Cable Assembly

40Gbps Parallel Active Optical Cable (AOC) Preliminary Datasheet

40Gb/s QSFP+ Parallel Active Optical Cable (AOC) QSFP-40G-xxAOC. Product Specification

QFPQL010400D QSFP+ Dual Fibre CWDM ITU CWDM / 10km / 40 Gigabit Ethernet / LR-4

QFPQL002400D QSFP+ Dual Fibre CWDM ITU CWDM / 2km / 40 Gigabit Ethernet / IR-4

Voltage (V) QSFP+ AOC 40G MMF 2m AC/AC Y 0 ~ +70 AQOA9N02ADLN0720. QSFP+ AOC 40G MMF 2.5m AC/AC Y 0 ~ +70 AQOA9N2AADLN0720

HSMC SATA RAID board [AB12-HSMCRAID] Manual [Ver1.0E]

QSFP+ 40GBASE-T Copper Transceiver Enhanced Small Form-factor Pluggable (QSFP+), 3.3V 40Gbps Gigabit Ethernet. Features

ewon Flexy 2 Serial Ports Ext. Card FLA 3301

40 Gigabit QSFP CWDM 1310 nm LR4 for 10 km

PROLABS QSFP-H40G-CUxM

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

Supplement to InfiniBand TM Architecture Specification Volume 2 Release Annex A5: Pluggable Interfaces: CATx, Copper and Optical.

Perle MCR200 Installation Guide

T Q S 2 1 L H 8 X 8 1 x x

Perle Cx-10GR-STS Media Converter Modules

Product Specification 100G Quadwire QSFP28 Active Optical Cable FCBN425QE1Cxx

One Technology Way P.O. Box 9106 Norwood, MA Tel: Fax:

Description. Features. Application. Ordering information

Quick Start Guide for TWR-SER2 TOWER SYSTEM. TWR-SER2 Enhanced serial module

Perle SMI Media Converter Installation Guide

XYT-DAC_QSFP+ to QSFP+

To Contact Us. c Copyright , NITGEN Co., Ltd. All rights reserved

ML52x User Guide. Virtex-5 FPGA RocketIO Characterization Platform. UG225 (v2.1) August 4,

Perle 10G Media Converter Modules

InfiniBand FDR 56-Gbps QSFP+ Active Optical Cable PN: WST-QS56-AOC-Cxx

Electromagnetic Interference (EMI) FCC Part 15 Class B Compatible with standards. FDA 21CFR and EN60950, EN (IEC) ,2

Product Specification 100G Quadwire EDR QSFP28 Active Optical Cable FCBN425QB1Cxx

Virtex-II Pro FF1152 Development Board User s Guide

Installation Instructions

Perle 10GT Media Converter Modules

Quad Small Form factor Pluggable Plus (QSFP/QSFP+)

SO-QSFP-LR4-20. QSFP, 40GBase-LR, CWDM, SM, DDM, 10dB, 20km OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

CHENBRO. SR30169 Server Chassis 4-Port 6Gb/s SAS/SATA Backplane. User s Manual 80H A0. Revision: 1.1. Dec / 3 / 2013

PMC494 10BaseT to 10Base2 PMC Media Converter

SO-QSFP-40G-PCUxM. QSFP to 4xSFP+, DAC, AWG30, 7m, passive OVERVIEW PRODUCT FEATURES ORDERING INFORMATION DATASHEET 4.1

Voltage (V) QSFP+ to 4xSFP+ 40G MMF 1M AC/AC Y 0 ~ +70 AKOA9N01ADLN0721. QSFP+ to 4xSFP+ 40G MMF 2M AC/AC Y 0 ~ +70 AKOA9N02ADLN0721

by Opal Kelly SYZYGY Specification Version 1.0

Falcon and Raptor Series Application Note: DUT Probing Options

PCI Express Gigabit Ethernet Adapter. User's Guide

T Q S H 8 X 8 2 x x

Perle 10G Media Converter Modules

APCO10-PPCXXX. 100Gb/s QSFP28 Active Optical Cable. Product Features. Applications. Gb/s QSFP28 Active Optical Cable

HSMC Ethernet 2-Port 1588 Precision Timing

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

User s Guide. ivolt. I 2 C Bus/SMBus Voltage Level Translator. For 1.5 V to 5 V Applications.

QSFP+ 4 x 10Gbps Direct Attach Cable OPQSFP-T-xx-xx Datasheet

GSC-PCI TO PMC ADAPTER

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

Accsense Wireless System. Temperature Monitor

Please visit SMSC's website at for the latest updated documentation.

DXF-200 DVI/HDMI Optical Extension System

24-Port Gigabit Ethernet Switches

Micro-Switch/ port 10/100Mbps. Desktop Fast Ethernet Switch. (Auto MDI/MDIX) FEP T- 3 USER S MANUAL

ML631 Virtex-6 HXT FPGA Packet Processor/Traffic Manager Evaluation Board

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number:

MC20902-EVB. MC20902 D-PHY 5-Channel Master Transmitter Evaluation Board User's Guide PRELIMINARY DATASHEET. Version February 2014.

SWITCH RC-415/RC-416 USER S Manual

19. VITA 57.1 FMC HPC Connector

ML630 Virtex-6 HXT FPGA Optical Transmission Network Evaluation Board User Guide. UG828 (v1.0) September 28, 2011

CFP-100G-LR4-C CFP 1310 nm wavelength 100GbE Transceiver

SFP 10/100/1000Mbit Copper RJ45 Transceiver

PCI Express Gigabit Ethernet Adapter. User's Guide

2100 POS System User Guide

ATA2000-PSU PC/104-Plus Power Supply and Storage Controller

DC6688SLP-USB Rev3.0 User Manual

RoHS compliant 40Gb/s QSFP+ SR4 Optical Transceiver 40GBASE-SR4, up to 100m MM Fiber Link. Features

FM486. PMC daughter card specifications

ADM-XRC-7Z2 User Manual

User s Guide. Mixed Signal DSP Solutions SLLU011

QTA1C04L2x000Exx 100G 10km QSFP28 LR4 Transceiver

RPX Series USER S MANUAL

2190 POS System User Guide

Transcription:

XRM-HSSDC2A High Speed Serial Adaptor Module User Guide

Copyright 2008 Alpha Data Parallel Systems Ltd. All rights reserved. This publication is protected by Copyright Law, with all rights reserved. No part of this publication may be reproduced, in any shape or form, without prior written consent from Alpha Data Parallel Systems Limited Alpha Data 4 West SilverMills Lane Edinburgh EH3 5BD Scotland UK Phone: +44 (0) 131 558 2600 Fax: +44 (0) 131 558 2700 Email: support@alpha-data.com Copyright 2008 Alpha Data Parallel Systems Ltd. All rights reserved. This publication is protected by Copyright Law, with all rights reserved. No part of this publication may be reproduced, in any shape or form, without prior written consent from Alpha Data Parallel Systems Limited. EMI This equipment generates, uses and can radiate electromagnetic energy. It may cause or be susceptible to electromagnetic interference if not installed and used with adequate EMI protection for specific applications

Table of Contents 1. Introduction...1 2. Installation...2 2.1. Handling instructions...2 3. Specification...3 3.1. Connector...3 3.2. Cableform...3 4. Related Documents...4 5. Design Examples...5 6. Pinout...6 7. Board Layout...7

PHOTO REQUIRED

1. Introduction The XRM-HSSDC2A is a front-panel adapter card designed for use with Alpha Data s ADM-XP, ADM-XRC-4FX, ADM-XRC-5T1 and ADM-XRC-5T2 PMC cards. Industry standard HSSDC2 connectors are used to provide external connectivity to a number of the Multi-Gigabit Transceivers ( MGTs) on the FPGA. The XRM-HSSDC2A allows easy connection of Alpha-Data FPGA cards to devices with compatible transceivers by means of simple, point-to-point cabling schemes implemented using off-the-shelf cables. Cableform HSSDC2 Serial Tx Serial Rx Cableform Cableform HSSDC2 HSSDC2 Serial Tx Serial Rx Serial Tx Serial Rx FPGA Application Cableform HSSDC2 Serial Tx Serial Rx Module Connector Clock Control Shading represents ADM-XRP components

2. Installation The XRM-HSSDC2A is designed to plug in to the front panel connector (SAMTEC QSH series) on Alpha-Data PMC cards. The retaining screws should be tightened to secure the XRM-HSSDC2A. Note: This operation should not be performed while the PMC card is powered up. 2.1. Handling instructions Observe precautions for preventing damage to components by electrostatic discharge. Personnel handling the board should take SSD precautions. Avoid flexing the board.

3. Specification 3.1. Connector AMP part number 1761069-3 ( replaces 1364532-3), keyed for Infiniband polarity. Pin Number Function 1 Gnd 2 RX + 3 RX - 4 Gnd 5 TX - 6 TX + 7 Gnd 3.2. Cableform Typical cableform ( 1 metre length) - Amp1364561-2

4. Related Documents ADM-XP User Manual ADM-XRC-4FX User Manual ADM-XRC-5T1 User Manual ADM-XRC-5T2 User Manual Infiniband Architecture Specification( Infiniband Trade Organisation, www.infinibandta.org)

5. Design Examples Example UCF, HDL files and Application software are available from Alpha Data for purchasers of this card.

6. Pinout UCF Name XP 4FX 5T1 5T2 Direction Function txp<0> a40 a36 u2 aa2 Out J1 6 txn<0> a41 a37 t2 y2 Out J1 5 rxp<0> a39 c39 t1 y1 In J1 2 rxn<0> a38 d39 r1 w1 In J1 3 txp<1> a36 a34 m2 t2 Out J2 6 txn<1> a37 a35 n2 u2 Out J2 5 rxp<1> a35 a31 n1 u1 In J2 2 rxn<1> a37 a32 p1 v1 In J2 3 txp<2> a8 p39 l2 j2 Out J3 6 txn<2> a9 r39 k2 h2 Out J3 5 rxp<2> a7 u39 f2 h1 In J3 2 rxn<2> a6 v39 g2 g1 In J3 3 txp<3> a4 m39 f2 d2 Out J4 6 txn<3> a5 ne9 g2 e2 Out J4 5 rxp<3> a3 j39 g1 e1 In J4 2 rxn<3> a2 k39 h1 f1 In J4 3 txp<4> bb4 at39 e2 r2 Out Loopback to Tx5 txn<4> bb5 au39 d2 p2 Out Loopback to Tx5 rxp<4> bb3 aw37 d1 p1 In Loopback from Tx5 rxn<4> bb2 aw36 c1 n1 In Loopback from Tx5 txp<5> bb8 ap39 b4 k2 Out Loopback to Tx4 txn<5> bb9 ar39 b3 l2 Out Loopback to Tx4 rxp<5> bb7 al39 a3 l1 In Loopback from Tx4 rxn<5> bb6 am39 a2 m1 In Loopback from Tx4 txp<6> bb36 aw25 b4 b1 Out Loopback to Tx7 txn<6> bb37 aw24 b6 b2 Out Loopback to Tx7 rxp<6> bb35 aw22 a7 a2 In Loopback from Tx7 rxn<6> bb34 aw21 a7 a3 In Loopback from Tx7 txp<7> bb40 aw28 b10 b6 Out Loopback totx6 txn<7> bb41 aw27 b9 b5 Out Loopback to Tx6 rxp<7> bb39 aw31 a9 a5 In Loopback from Tx6 rxn<7> bb38 aw30 a8 a4 In Loopback from Tx6 brefck_enab l27 ac25 h20 l30 ah39 on rev3 (link configured) brefck_in_p g22 f19 h14 l16 Link configured for XP brefck_in_n f22 f18 h15 l15 Link configured for XP Note that only TX0 to TX3 are accessible externally via J1-J4.

7. Board Layout

Revision History Date Revision Nature of Change Nov-2006 1.0 Initial draft Dec-2008 1.1 Added 4FX,5T1 and 5T2 documentation