Juniper Virtual Chassis Technology: A Short Tutorial

Similar documents
Unified Access Network Design and Considerations

Virtual Chassis Fabric Best Practices Guide

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

IBM Ethernet Switch J48E

Introduction to Cisco ASR 9000 Series Network Virtualization Technology

Data Center Design IP Network Infrastructure

PrepKing. PrepKing

TECHNICAL BRIEF. 3Com. XRN Technology Brief

IMPLEMENTING A LAYER 2 ENTERPRISE INFRASTRUCTURE WITH VIRTUAL CHASSIS TECHNOLOGY

Cisco Nexus 4000 Series Switches for IBM BladeCenter

Rack-Level I/O Consolidation with Cisco Nexus 5000 Series Switches

Pass-Through Technology

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

BROCADE ICX 6610 SWITCHES FREQUENTLY ASKED QUESTIONS

Dell DCPPE-200. Dell PowerEdge Professional. Download Full version :

OmniSwitch 6850E Stackable LAN Switch

Borderless Campus Design and Deployment Models

BUILD A BUSINESS CASE

Community College LAN Design Considerations

Cisco I/O Accelerator Deployment Guide

BROCADE ICX 6610 SWITCHES FREQUENTLY ASKED QUESTIONS

Top-Down Network Design

WHITE PAPER. Copyright 2010, Juniper Networks, Inc. 1

HP0-Y50. Architecting HP FlexNetwork Solutions.

GUIDE. Optimal Network Designs with Cohesity

LAN design. Chapter 1

Community College LAN Deployment Guide

Introduction. Network Architecture Requirements of Data Centers in the Cloud Computing Era

DATA CENTER FABRIC COOKBOOK

Cisco Etherswitch Service Modules

Virtual Switching System

VIRTUAL CLUSTER SWITCHING SWITCHES AS A CLOUD FOR THE VIRTUAL DATA CENTER. Emil Kacperek Systems Engineer Brocade Communication Systems.

CCNP Switch Questions/Answers Cisco Enterprise Campus Architecture

NETWORK ARCHITECTURES AND CONVERGED CLOUD COMPUTING. Wim van Laarhoven September 2010

Layer 2 Implementation

THE OPEN DATA CENTER FABRIC FOR THE CLOUD

Cisco UCS Virtual Interface Card 1225

Configuring Virtual Port Channels

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE

Configuring Virtual Port Channels

DAY ONE: CONFIGURING EX SERIES ETHERNET SWITCHES

THE EXPONENTIAL DATA CENTER

Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches

SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper

Meraki MX Family. Overview

TITLE. the IT Landscape

Trends in Data Centre

Campus Networking Workshop. Layer 2 engineering Spanning Tree and VLANs

Messaging Overview. Introduction. Gen-Z Messaging

Cisco Nexus 7000 Series Connectivity Solutions for the Cisco Unified Computing System

Configuring StackWise Virtual

Juniper Networks Switching: EX & QFX Series

Deploying Data Center Switching Solutions

SRX Services Gateway Cluster Deployments Across Layer Two Networks. Deployment requirements for SRX cluster connectivity across layer two networks

MC-LAG to VPLS Technology and Solution Overview

Networking solution for consolidated IT infrastructure

Datacenter Class Reliability for High-Performance Business

Technical Document. What You Need to Know About Ethernet Audio

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

Traditional network management methods have typically

IBM Europe Announcement ZG , dated February 13, 2007

PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND ISCSI INFRASTRUCTURE

Solutions Guide. Building distributed network cores with Allied Telesis switches

Vendor: Cisco. Exam Code: Exam Name: Designing Cisco Data Center Unified Fabric (DCUFD) Version: Demo

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Dell PowerEdge M1000e Blade Enclosure and Dell PS Series SAN Design Best Practices Using Dell S-Series and M-Series Networking

Cisco Certdumps Questions & Answers - Testing Engine

Fail safe LAN connectivity

Reference Architecture Microsoft Exchange 2013 on Dell PowerEdge R730xd 2500 Mailboxes

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays

Cisco UCS Virtual Interface Card 1227

Cisco 4000 Series Integrated Services Routers: Architecture for Branch-Office Agility

A Dell Interoperability Whitepaper Victor Teeter

Introduction to OSPF

IBM Ethernet Switch J08E and IBM Ethernet Switch J16E

Evolution with End-to-End Data Center Virtualization

Stacking on Cisco Catalyst 2960-X and 2960-XR: FlexStack-Plus and FlexStack-Extended


Cisco Meraki MS400 Series Cloud-Managed Aggregation Switches

Table of Contents 1 MSTP Configuration 1-1

Configuring EtherChannels and Link-State Tracking

IDENTIFICATION OF VOLATILE AND NON-VOLATILE STORAGE AND SANITIZATION OF SYSTEM COMPONENTS. JUNIPER NETWORKS EX2200 and EX2200-C Switches

Cisco CISCO Data Center Networking Infrastructure Design Specialist. Practice Test. Version

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

IT Agility Delivered: Cisco Unified Computing System

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems

Cisco FirePOWER 8000 Series Appliances

How to Build a Data Center Network With QFabric Products Acting as a Layer 3 switch

Introducing Avaya SDN Fx with FatPipe Networks Next Generation SD-WAN

SAP High-Performance Analytic Appliance on the Cisco Unified Computing System

Mellanox Virtual Modular Switch

16GFC Sets The Pace For Storage Networks

DriveScale-DellEMC Reference Architecture

Switching for Intent-Based Networking-Campus, Branch, and Data Center

CAMPUS AND BRANCH RECAP. Ralph Wanders Consulting Systems Engineer

Chapter 5. Enterprise Data Center Design

UM DIA NA VIDA DE UM PACOTE CEE

Configuring Rapid PVST+

Transcription:

Juniper Virtual Chassis Technology: A Short Tutorial Victor Lama Fabric Specialist LE Northeast Region August 2010 What if? What if your company could drastically minimize the complexity of managing your data center network by being able to take multiple network appliances and manage them as if they were just one device? What if there was a modular network switching solution that offered dual routing and switching engines with graceful failover in the event of an outage, as well as in-service hardware replacement and code upgrades? What a tremendous impact that would make toward providing high availability to mission critical applications and services! What if network architects could finally do away with the design complexities of deploying the Spanning Tree Protocol by virtualizing multiple layers in the data center? No more worries about interoperability of STP, MSTP, RSTP, PVRSTP, CST, across vendor platforms, and no more blocking and wasting half your data center s cross-sectional bandwidth! What if those who hold your company s purse strings could scale your network CAPex as the business need arises, instead of just having to make large capital investments up front? With Juniper s Virtual Chassis technology, all the above, and more, are possible. What is Virtual Chassis Technology? Virtual Chassis (VC) is a network virtualization technology offered in several models of Juniper Ethernet switches, such as the EX4200. With VC, between 2 and 10 physical Ethernet switches can be stacked to form a single logical form factor with a unified control plane and configuration file, as well as a single OS instance that operates across the entire stack. Route and switch engine redundancy are provided by the VC master and the backup through the creation and maintenance of synchronized forwarding tables and the exchange of stateful protocol information. The VC can span anywhere from 5 meters in height and breadth to 50 km across an entire campus or regional area! Using the EX4200 as an example, between 24 and 480 10/100/1000 Mbps ports can be managed as if they belong to one VC that supports multiple VLANs, a non-blocking architecture and full cross-sectional bandwidth utilization. Connecting the members of a Virtual Chassis in a ring topology results in a total virtual backplane speed of 128Gbps 64Gbps in each direction. A key factor to understand is that Virtual Chassis technology deploys a direct path algorithm known as the Virtual Chassis Control Protocol (VCCP) for optimal traffic flow. Forwarding tables are built with the aggregate

intelligence of all the members of the VC, thereby ensuring that traffic takes the shortest path to its destination. VC is one of the core enabling technologies of Juniper s vision for the data center of the future, otherwise known as Stratus. The foundational concept behind Stratus is to replicate the simplicity of a single fabric in a single switch chassis across the data center or between data centers! The result is a resilient low-latency data center fabric that has the built in flexibility to support converged networks and virtualized workloads in a variety of different topologies. Building a Virtual Chassis As noted above, the physical members of a VC can be collocated in a configuration that spans no more than 5 meters between stack elements. A VC configuration consisting of adjacent switches interconnected with special 0.5 meter, 1.5 meter, 3 meter, or 5 meter VC port cables is called a dedicated configuration. A VC configuration interconnected via Gigabit Ethernet or 10-Gigabit Ethernet uplink ports across distances up to 50 km is called an extended configuration. Figure 2 shows a rear view of a Juniper EX4200 Ethernet switch and the VC Ports (VCP) that interconnect the different VC elements. Each VCP offers 64Gbs of throughput for data traffic as well as protocol state information to maintain synchronized control and data planes between the Master and the Backup Route- Switch Engines (RSE).

Once the VCP ports are cabled, they are automatically enabled to provide the switching backplane for the dedicated chassis configuration. To extend the VC configuration across a campus or regional area, the EX-UM-2X4SFP 10Gbps module, with dual 10G ports, can be deployed and configured to carry VC control information over an aggregated link that provides up to 40Gbps of throughput 20Gbps in each direction. Virtual Chassis Member Roles Dedicated Chassis Each member in a Virtual Chassis configuration is assigned a specific role. A role determines the functions the member performs in the configuration. One member is assigned the master role and is responsible for managing other members in the Virtual Chassis configuration. Another member is assigned the backup role and takes over the master role if the master switch fails. All other members are assigned the line card role. The system executes a mastership election algorithm to determine member roles.

Virtual Chassis Roles Extended Configuration In an extended configuration, the master and the backup should be in different locations as part of dedicated chassis configurations. Moreover, the extended VCP connections can consist of gigabit, ten gigabit or aggregated Ethernet port connections for higher bandwidth requirements. Cabling Options There are three different methods for connecting members of a Virtual Chassis. These are the daisy-chained ring, the braided-ring and the extended configuration. The daisy-chained and braided ring methods are deployed in dedicated chassis configurations, with the braided-ring offering a greater maximum distance between the first and last member of the stack.

See figure 6a and 6b below. As noted earlier, an extended chassis consists of smaller dedicated virtual chassis interconnected by Ethernet ports in a singular or bundled fashion. This capability provides the flexibility to manage an entire campus LAN as one management plane with one IP address and a singular control plane that allows for automatic configuration and code upgrades upon introduction of a new member to the VC. This is known as dynamic installation. See figure 6C below.

Virtual Chassis Deployment Options Data Center Top of Rack (ToR) The data center top of rack deployment is suitable for environments in which members of the Virtual Chassis configuration are collocated with servers in the same rack. A single Virtual Chassis configuration consisting of multiple switches in the same rack simplifies management by reducing the number of managed devices. This deployment also provides servers with the capability of configuring NIC teaming (LAG) to multiple members of the same Virtual Chassis configuration, increasing the total server network bandwidth while providing server link redundancy. See figure 7 below.

As figure 8 shows, in a Dell m1000e blade server deployment that includes M-series stackable blade switches, virtualization of the edge and access layer can be achieved, thereby removing the need for the deployment of the Spanning Tree Protocol. Multiple physical connections between the blade switches and the ToR VC will be seen as one logical link by each virtual layer. This allows for a non-blocking rack architecture and full utilization of available cross-sectional bandwidth.

Single Virtual Chassis Spanning Entire Row Depending on server density and spacing the ToR solution can be extended to support an entire row of cabinets 10 cabinets if one switch is placed at the top of the rack or 5 if the design calls for a self-contained modular cabinet that can be removed or deployed at will. In the latter, all the server-to-tor cables will be confined to the cabinet. The ToR switches shown below all belong to the same Virtual Chassis.

End of Row (EoR) Because the EX4200 Virtual Chassis can support layer 2 and layer 3 deployments, it can also play the role of an end of row solution. Typically, the EoR is a layer 3 aggregation/distribution layer that includes the deployment of transparent data center services, such as load balancing, firewalls, SSL offloads, etc. Campus LAN Wiring Closet(s) and Campus Aggregation Hopefully by now, the concept should be clear: the Virtual Chassis technology allows the network architect to be extremely flexible and creative in deploying design solutions. A VC can be deployed in many different topological scenarios and in different network roles. In a campus environment, a VC can be formed in a single wiring closet or in several closets across a user-floor(s). The access layer and the campus distribution layer can both exist as VC instances. Wiring closets that are more than 5 meters apart can be connected via gigabit, 10- gigabit and aggregated Ethernet connections, just as they were in our data center examples. The campus aggregation layer can consist of a single Virtual Chassis instance or multiple instances, depending on the traffic requirements. The thing to keep in mind is that deploying separate VC instances in the aggregation layer will require the deployment of STP between VCs and the access layer, thereby mitigating the benefit of virtualizing network layers. See figure 11 below.

Summary Deploying a Virtual Chassis solution in a high performance data center reduces the complexity of switch hardware installations, OS upgrades, configuration tasks, and management of the switched fabric. Moreover, virtualizing multiple layers is one of the necessary steps toward the creation of a flat data center network in which all L2 links are utilized and multiple layers of packet processing are eliminated. This will minimize latency, remove the need to deploy L2 loop mitigation technology, and create a non-blocking fabric with an average x2 increase in available cross-sectional bandwidth across the data center.