ICP PANEL-TEC PEX3000 II

Similar documents
MODBUS/TCP TO SIEMENS G110/G120/MM440 APPLICATION

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

Technical Instructions Document No February 25, Modbus RTU Interface Module for SED2. Description. Product Part Number

Select a Data Communication Interface

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

Sender Receiver Sender

using the Data-Linc SRM6000 Spread Spectrum Radio Modem (version 5.39) and Wonderware InTouch 95 (version 7.0.1)

Serial Interfaces Part 1. ECE 153B Sensor & Peripheral Interface Design Winter 2016

Appendix A Cable Pinouts

MUCM ModLon Gateway. Installation and Programming Manual

Cable Pinouts. SRP I/O Module

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651)

Bluetooth TO Serial CONVERTER E-P132-B

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

Automationdirect.com. D i r e c t L o g i c M O D B U S S L A V E F 4 S L V - M B

FAST_EnergyCam-Communication-Interfaces.doc 7/7/2016 Page 1 of 6

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS

USER MANUAL FOR GS100/GS1003G

MGate 4101-MB-PBS Series

Installation and Programming Manual

LM058 Bluetooth v2.0, v2.1 RS232 Serial Adapter - SMA Connector Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

TRP-C37M User s Manual

User Manual A08. User Manual

TRP-C37M User s Manual

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

Connector and Cable Specifications

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

EtherSeries Modbus Gateway EMB-2 User s Guide

Industrial Serial Device Server

DGH A3000 Configuration Guide For use with DGH Modules

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

ISDA/ISDA4 Protocol Driver Manual. Table of Contents

User's Manual PLC09 Modbus Converter for PAL-AT Leak Detection System

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

T1K MODBUS Base Controller Specifications

IntesisBox Modbus Server Fidelio IP

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232C

LM048 Bluetooth v2.0, v2.1 RS232 Serial Adapter Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

ProtoConvert Modbus RTU / Modbus TCP/IP / BACnet MSTP / BACnet IP / SNMP - Telnet (Lighting Controller) PG

MGate 5105-MB-EIP Quick Installation Guide

Unique Micro Design. Advanced Thinking Products. Model 164 Quad Coupler User Manual

Cabling Guide for Console and AUX

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2

BLE232: Manual Copyright 2014 taskit GmbH

Miniature Asynchronous 4-Wire High Speed Modems

Table 8 shows the pin configuration and function of a standard computer-to-printer parallel cable. Table 8 Parallel Cable Pin Configuration

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485)

Active RFID Reader User Manual

1. Overview Technical Specifications Applications Pin Description Connection Diagram of RS 485 / 422 Converter...

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc.

PCI Express 16-Port Serial I/O Cards

Attaching Inputs and Outputs

LM058 Bluetooth Serial Adapter

Overview. Table of contents

IntesisBox Modbus Server Panasonic

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

REL 512 Connectivity With A Harris Westronics RTU Using DNP 3.0

RS-232 to Logic Level Adapter with DB9M Connector and Power LED

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

Manual Fiber Optic Interfaces

-C5RS-LC RS232 EXTENDER

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

Modbus Gateway User's Manual ADM-5850G

DIN Rail Mounted Dial-up Modem Users Manual

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

ABLELink. Modbus Gateway MB5000 Series User s Manual

iopro Mirrored IO System

MGate 5118 Quick Installation Guide

MGate 5105-MB-EIP Series

ICRM SER User s Guide

MGate MB3000 Modbus Gateway User Manual

INSTALLATION GUIDE Maxiflex P3e CPU M1262F

Integrity Instruments

PCIe Card Selection Guide. PCIe-CAN Card. PCIe-COM Card. Taiwan Pulse Motion Co.,Ltd. Bus Interface PCI Express x 1 LPE-C122 PCE-C122D PCE-C122T

User Guide. Date Apr BlueEva+C11/G2. Stollmann. E + V GmbH. User Guide

USB-TTL-5 PRODUCT IS A COMBINATION OF PRODUCTS USB AND TTL-232-5P BOTH DATASHEETS ARE INCLUDED IN THIS PDF FILE

Ethernet Serial Server

Industrial Gateway Solutions

IBOX Modbus Server ESSER 8xxx/IQ8/FlexES fire panels

SST-2450 Wireless Modem User s Manual

Domain 3000 Back Panel

WiFi to RS-232 adapter user manual

Bluetooth RS232 Serial Adapter

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

edbox-100 SmartStack Box for PSTN

WiFi to RS-232 adapter user manual

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

USER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION

International Headquarters. European Headquarters

Transcription:

ICP PANEL-TEC PEX3000 II MODBUS PORT EXPANDER INSTALLATION AND OPERATION GUIDE

REVISION HISTORY Revision Date Author Comments 000 29 Aug 2008 Keira Majors Initial release. 001 16 Sep 2008 David Walker Updated configuration information 002 13 Feb 2009 David Walker Changed pn: 6003-0403 6003-403-100 ICP Panel-Tec 2

TABLE OF CONTENTS Revision History...2 Table of Contents...3 Introduction...4 Port Configuration...4 Power Supply...4 Ordering Information...4 Hardware...5 Serial Ports...5 Local Master Port (LCL)...5 Slave Port (SLV)...5 Remote Master Port (REM)...5 Serial Port Pinouts...5 Serial Cables...6 232 Communications...6 485 Communications...6 PEX3000 II Power Supply...6 Wall Mount Power Supply...7 External Power Supply...7 LED Indicators...8 PEX3000 II Configuration...9 Configuration Cable...9 Default Configuration...9 Changing the Configuration...10 Local Port Configuration Settings...11 Frame Format...11 Gap Time...11 Timeout...11 Slave Port Configuration Settings...12 Frame Format...12 Gap Time...12 Remote Port Configuration Settings...13 Port Mode...13 Frame Format...13 Gap Time...13 Timeout...13 PEX3000 II Operation...14 Port Multiplexer Operation...14 ICP Panel-Tec 3

INTRODUCTION The PEX3000 II is a DIN Rail Mount version of the original PEX3000. It is a 3-Port device that allows two Modbus Masters to communicate with one or more Modbus Slaves. It is most commonly used as a multiplexer to prevent Modbus message collisions from the two masters. Each port on the PEX3000 is individually configured so the Modbus Master(s) and Modbus Slave(s) can have different port configurations. In addition, they can use different Modbus protocol formats (RTU/ASCII) and the PEX3000 will perform the necessary conversions. Port Configuration The PEX3000 II has 3 DB9 ports. All ports can be configured for either RS232 or 2-Wire RS485 communication. The first port is a DB9 female RS232 DCE port for connection of the Local Master. The second port is a DB9 Male RS232 DTE for connection of the Modbus Slave(s). The third port is a DB9 female RS232 DCE port for connection of a Remote (or second local) Master. The RS485 signals are located on the same pins on all three ports regardless of whether they are DTE or DCE. The utility to configure the ports is built into the PEX3000 II. It is activated by connecting the RS-232 pins of any of the ports to the serial port of a PC running a terminal communication program such as HyperTerminal, and entering the correct key sequence within 5 seconds of powering up the PEX3000 II. Power Supply The PEX3000 II is powered by any DC voltage from 7 to 27 volts. A 3-position pluggable terminal block is used to connect the power supply. Please note that the pinout of the 3-position plug is not compatible with the original PEX3000. The terminal block plug must be re-wired if a power supply used with an older PEX3000 is being used to power a PEX3000 II. Ordering Information The part numbers for the PEX3000 II Modbus unit, power supply, and optional cables are shown in the following table. Table 1 - Part Numbers Part Number Description 6003-403-100 PEX3000 II 4000-0202 PEX3000 II Power Supply 6000-RS232 PEX3000 II Configuration Cable Modbus Device Cable for any Port (Straight-Through DB9F to DB9M RS232 Cable) 6000-RS232N Modbus Device Cable for any Port (Null-Modem DB9F to DB9F RS232 Cable) 6000-0003 Modbus Device Cable for Local and Remote Master Ports (DB9M to Stripped Wires, 2-Wire RS485 Cable) 6000-0006 Modbus Device Cable for Slave Port (DB9F to Stripped Wires, 2-Wire RS485 Cable) 6000-0008 Modbus Device Cable for Local and Remote Master Ports (DB9M to Stripped Wires, RS232 Cable) 6000-0009 Modbus Device Cable for Slave Port (DB9F to Stripped Wires, RS232 Cable) ICP Panel-Tec 4

HARDWARE Serial Ports The PEX3000 II has three serial ports with DB9 connectors. All ports can be configured for either RS232 or 2-Wire RS485 communication. Local Master Port (LCL) The Local Master port can be used to connect a local Modbus master device to the PEX3000 II. A DB9-Female connector is used for this port which requires the mating cable to have a DB9-Male connector on it. Slave Port (SLV) The Slave Port is used to connect one or more Modbus slave devices to the PEX3000 II. A DB9-Male connector is used for this port which requires the mating cable to have a DB9-Female connector on it. Remote Master Port (REM) The Remote Master port can be used to connect either a second local master or a remote master through an RF link. A DB9-Female connector is used for this port which requires the mating cable to have a DB9-Male connector on it. Serial Port Pinouts The pinouts for the serial ports are shown in the table below. Table 2 - Serial Port Pinouts Local & Remote Master Ports DB9-Female Slave Port DB9-Male Pin Label Description Pin Label Description 1 D+ RS485 D+ 1 D+ RS485 D+ 2 TXD RS232 TxD 2 RXD RS232 RxD 3 RXD RS232 RxD 3 TXD RS232 TxD 4 DTR RS232 DTR 4 No Connect 5 GND Signal Ground 5 GND Signal Ground 6 D- RS485 D- 6 D- RS485 D- 7 CTS RS232 CTS 7 RTS RS232 RTS 8 RTS RS232 RTS 8 CTS RS232 CTS 9 No Connect 9 - No Connect ICP Panel-Tec 5

Serial Cables 232 Communications When a port is configured for RS232 communications, an off-the-shelf straight-through or null-modem is generally used to connect to other Modbus devices. The type of cable required and optional cable that can be purchased from ICP -Panel-Tec are shown in the following table. Table 3 RS232 Cables PEX3000 II Port Modbus Device Type Recommended Cable Local or Remote Master RS232 DTE with DB9 connector 6000-RS232 (Straight-Through DB9/DB9) Local or Remote Master RS232 DCE with DB9 connector 6000-RS232N (Null-Modem DB9/DB9) Local or Remote Master RS232 DTE/DCE with terminal block 6000-0008 (DB9M to Stripped Wires) Slave RS232 DTE with DB9 connector 6000-RS232N (Null-Modem DB9/DB9) Slave RS232 DCE with DB9 connector 6000-RS232 (Straight-Through DB9/DB9) Slave RS232 DTE/DCE with terminal block 6000-0009 (DB9F to Stripped Wires) 485 Communications When a port is configured for RS485 communications, the connector on the Modbus device(s) being connected to the PEX3000 II can vary significantly. Because of this, all optional RS485 cables offered by ICP Panel-Tec end in stripped wires to provide maximum flexibility. The cables available for both master ports and the slave port are shown in the following table. Table 4 RS485 Cables PEX3000 II Port Modbus Device Type Recommended Cable Local or Remote Master 2-Wire RS485 with any connector 6000-0003 (DB9 Male to Stripped Wires) Slave 2-Wire RS485 with any connector 6000-0006 (DB9 Female to Stripped Wires) PEX3000 II Power Supply The PEX3000 II requires a 500 ma DC power supply with any voltage from 7 27 Volts DC. A pluggable terminal block is used for connection of the power supply. The format of the terminal socket on the PEX3000 II is shown in the following figure. Figure 1 Power Supply Connector ICP Panel-Tec 6

Wall Mount Power Supply The following figure shows how to connect a wall-mount power supply to the PEX3000 II. Figure 2 Connecting a Wall-Mount Power Supply External Power Supply The following figure shows how to connect an external power supply to the PEX3000 II. The V- and V+ connections are mandatory but the Earth Ground Reference is optional. Figure 3 Connecting an External Power Supply ICP Panel-Tec 7

LED Indicators There are a total of 4 Bi-color LED indicators on the PEX3000 II. The APP LED displays the overall status of the PEX3000 II. The LCL LED displays communications activity on the Local Master port. The SLV LED displays communications activity on the Slave port. The REM LED displays communications activity on the Remote Master port. Table 5 APP LED Indications For this state: LED is: To indicate: No Power Off There is no power applied to the device. Startup Solid Green The PEX3000 II is checking the ports for a valid configuration startup sequence prior to entering RUN Mode. Run Mode Flashing Green (250ms On, 250ms Off) The PEX3000 II is operating normally in RUN Mode. Configuration Mode Flashing Green (1.5 sec On, 1.5 sec Off) The PEX3000 II is in Configuration Mode. Fatal Error Flashing Yellow The PEX3000 II has experienced a fatal error and has (any rate) halted communications. Table 6 LCL LED Indications For this state: LED is: To indicate: Receive Data Red The PEX3000 is receiving data from the Local Modbus Master. Transmit Data Green The PEX3000 is transmitting data to the Local Modbus Master. Table 7 SLV LED Indications For this state: LED is: To indicate: Receive Data Red The PEX3000 is receiving data from a Modbus Slave. Transmit Data Green The PEX3000 is transmitting data to a Modbus Slave Table 8 REM LED Indications For this state: LED is: To indicate: Receive Data Red The PEX3000 is receiving data from the Remote Modbus Master. Transmit Data Green The PEX3000 is transmitting data to the Remote Modbus Master. ICP Panel-Tec 8

PEX3000 II CONFIGURATION Configuration Cable Any of the ports on the PEX3000 II may be used for configuration via the RS-232 signals on the port. A straightthrough DB9 cable (Order Number 6000-RS232) can be used to connect the LCL or REM port on the PEX300 II to a serial port on a PC for configuration. A null modem cable (Order Number 6000-RS232N) is necessary to configure the PEX3000 II via the SLV port. The minimum pin connections for the standard configuration cable are shown in the following figure. PEX3000 II LCL or REM Port DB9-Male PC Serial Port DB9-Female TXD 2 RXD 3 GND 5 2 RXD 3 TXD 5 GND Default Configuration Figure 4 Minimum Configuration Cable Pinout for LCL or REM port The default configuration is shown on the following configuration screen. ICP Panel-Tec 9

Changing the Configuration The configuration stored in the PEX3000 II may be changed from the default configuration by entering Configuration Mode. 1. Power off the PEX3000 II. 2. Attach a configuration cable between any port on the PEX3000 II and a serial port on a PC. 3. Start a terminal program, such as HyperTerminal on the PC, and connect using the following settings: o Baud = 19200 bps o Data bits = 8 o Parity = None o Stop Bits = 1 o Flow Control = None 4. Apply power to the PEX3000 II, and send the configuration start sequence ( +++ ) by pressing the plus key three times within 5 seconds of startup. Once the PEX3000 II is in Configuration Mode, it will send its current configuration information to the terminal program, as follows: Figure 2 PEX3000 II Configuration Display Use the up and down arrows on your keyboard to navigate to the field you want to change, then use the left and right arrows to change the value in that field. When you are finished, navigate to Save Configuration and press the Enter key to save the configuration information to the PEX3000 II. If the configuration is invalid, a message will be displayed indicating the reason. If the configuration was successfully saved, a Configuration Saved message will be displayed. Once the configuration has been saved, remove power from the PEX3000 and remove the configuration cable. ICP Panel-Tec 10

Local Port Configuration Settings The Local port, labeled LCL on the front panel of the PEX3000 II, may be connected to a local Modbus master device. Any device that will initiate Modbus requests is considered to be a Modbus master device. The following configuration settings may be changed for the Local port: Frame Format Setting Values Default Protocol Modbus RTU Modbus ASCII Modbus RTU Port Mode RS-232 RS-485 RS-232 Baud Rate 9600 bps 19200 bps 38400 bps 9600 bps 57600 bps 115200 bps Frame Format 7E1 * 7O1 * 7N2 * 8N1 8E1 8E1 8O1 8N2 Gap Time 5 ms 500 ms 50 ms Timeout 250 ms 10 sec 2 sec * 7 data bits not supported for Modbus RTU Frame Format is listed by data bits (7 or 8), parity (Even, Odd or None), and stop bits (1 or 2) - i.e. 8E1 indicates 8 data bits, even parity, and 1 stop bit. Note: Because Modbus RTU is encoded as 8-bit binary data, frame formats utilizing 7 data bits are not supported for Modbus RTU. Gap Time Gap Time is the maximum time allowed between received characters in a Modbus RTU message before giving up on that message. It is there to handle sudden loss of communications (power loss, cable unplugged or severed, etc.) smoothly. The default value of 50ms should be sufficient for most networks. Timeout Timeout is the maximum time that the Local port will wait for a response to be received on the Slave port before timing out on the current request and listening for a new request. The timer starts when the original request message is received on the Local port. For proper timeout handling, it MUST be set to a value lower than the timeout programmed into the Modbus master device. For situations where two masters are polling the same slave, the timeout value for the Local port should be set to about ½ the timeout value programmed into the master. ICP Panel-Tec 11

Slave Port Configuration Settings The Slave port, labeled SLV on the front panel of the PEX3000 II (or NET for the first run of products), may be connected to a Modbus slave device. Any device that will only respond to Modbus requests addressed to itself is considered to be a Modbus slave device. The following configuration settings may be changed for the Slave port: Frame Format Setting Values Default Protocol Modbus RTU Modbus ASCII Modbus RTU Port Mode RS-232 RS-485 RS-232 Baud Rate 9600 bps 19200 bps 38400 bps 9600 bps 57600 bps 115200 bps Frame Format 7E1 * 7O1 * 7N2 * 8N1 8E1 8E1 8O1 8N2 Gap Time 5 ms 500 ms 50 ms * 7 data bits not supported for Modbus RTU Frame Format is listed by data bits (7 or 8), parity (Even, Odd or None), and stop bits (1 or 2) - i.e. 8E1 indicates 8 data bits, even parity, and 1 stop bit. Note: Because Modbus RTU is encoded as 8-bit binary data, frame formats utilizing 7 data bits are not supported for Modbus RTU. Gap Time Gap Time is the maximum time allowed between received characters in a Modbus RTU message before giving up on that message. It is there to handle sudden loss of communications (power loss, cable unplugged or severed, etc.) smoothly. The default value of 50ms should be sufficient for most networks. ICP Panel-Tec 12

Remote Port Configuration Settings The Remote port, labeled REM on the front panel of the PEX3000 II (or USR for the first run of products), may be connected to another local Modbus master device, or to a remote Modbus master device via a radio modem or other gateway. Any device that will initiate Modbus requests is considered to be a Modbus master device. The following configuration settings may be changed for the Remote port: Port Mode Setting Values Default Protocol Modbus RTU Modbus ASCII Modbus RTU Port Mode RS-232 RS-485 RS-232 RS-232 RTS/CTS Baud Rate 9600 bps 19200 bps 38400 bps 9600 bps 57600 bps 115200 bps Frame Format 7E1 * 7O1 * 7N2 * 8N1 8E1 8E1 8O1 8N2 Gap Time 5 ms 500 ms 50 ms Timeout 250 ms 10 sec 2 sec * 7 data bits not supported for Modbus RTU In addition to RS-232 and RS-485, the Remote port also supports RS-232 with hardware flow control (RTS/CTS). In this mode, the Remote port will raise the RTS signal and wait for an aswering CTS signal prior to transmitting a message. Frame Format Frame Format is listed by data bits (7 or 8), parity (Even, Odd or None), and stop bits (1 or 2) - i.e. 8E1 indicates 8 data bits, even parity, and 1 stop bit. Note: Because Modbus RTU is encoded as 8-bit binary data, frame formats utilizing 7 data bits are not supported for Modbus RTU. Gap Time Gap Time is the maximum time allowed between received characters in a Modbus RTU message before giving up on that message. It is there to handle sudden loss of communications (power loss, cable unplugged or severed, etc.) smoothly. The default value of 50ms should be sufficient for most networks. Timeout Timeout is the maximum time that the Local port will wait for a response to be received on the Slave port before timing out on the current request and listening for a new request. The timer starts when the original request message is received on the Local port. For proper timeout handling, it MUST be set to a value lower than the timeout programmed into the Modbus master device. For situations where two masters are polling the same slave, the timeout value for the Local port should be set to about ½ the timeout value programmed into the master. ICP Panel-Tec 13

PEX3000 II OPERATION Port Multiplexer Operation The PEX3000 II waits until a complete Modbus message has been received on the Local or Remote port.. If the message is valid, it will buffer the message until the Slave port is free. At this point it will forward the message out the Slave port, converting between Modbus ASCII and RTU if necessary. It then waits for a response to be received from the addressed slave on the Slave port. If a response is received before the configured timeout value, the Slave port will forward the response to the originating port, once again converting between Modbus ASCII and RTU if necessary, and the originating port will transmit the response back to the originating Modbus master device. Because the PEX3000 II actively buffers and converts messages on the fly, all of the ports can be configured for different protocols, port modes, baud rates and frame formats without affecting throughput. ICP Panel-Tec 14