D20 Status Input Module

Similar documents
GE Grid Solutions. DNP I/O Modules. Installation and Maintenance Guide Version 2.00 Revision 12. GE Information

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

Remote Terminal Unit ER1000 APPLICATION FEATURES

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

VMIVME-1182 Specifications

NTX Series Product Comparison

NovaTech Orion I/O Overview

INSTALLATION INSTRUCTIONS

GE Intelligent Platforms PAC8000 RTU

2 NOVATECH. This page is intentionally left blank.

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

VMIVME-1184 Specifications

Scout-S Station Controller

DSP240-LPI Inverter Controller Card. Technical Brief

SOLUTIONS FOR AN EVOLVING WORLD. GARD Pro. Programmable Single Function PLC Hubbell Incorporated Gard Pro Programmable Single Function

SCADAPack Smart RTU

S-series Mass Connection Solutions

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

PROGRAMMABLE MARQUEE DISPLAYS

PCIEMODBOX232 RS232 to PCI Module Box Introduction

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU TELEM MODULES TELEM-DO8, TELEM-DI24 and TELEM-AI12 (REMOTE TERMINAL UNIT)

Single Phase Systems-North American PC125/PC420 Series

SCADAPack ES. Smart RTU

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SCADAPack ES. Smart RTU

Ovation Compact Controller

MINER-S Station Controller. Substation Automation

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

Multilin EPM 6010 YEAR. GE Grid Solutions. Building Automation Power Meter with BacNET /IP Communications. Monitoring & Metering

Shown with terminal block Supports diagnostic point fault contacts in the logic program

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE

Owner s Hardware Service Manual Frank Control Computer System

S-series Sequence of Events Card

Ovation Ethernet Link Controller Module Data Sheet

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

P3-SCM. General Specifications

MINER-S Station Controller

Digital Lighting Systems, Inc.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

ICN Mini Link/External. User s Guide. 1733N Model A Mini Link/EXT (Version 1) 1732N Model A ICN Interface Board (Version 1)

45SD Series Bus Expansion Cards For use with Q45X Series Photoelectric Sensors on SDS Bus Networks

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

SEL-2414 Transformer Monitor

GE Energy D25 IED. User's Manual Version 3.00 Revision 1. General

Micro-Modular Programmable Controller

Quick Start Installation Guide

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

PM800 series. Applications

SOLUTIONS FOR AN EVOLVING WORLD RFL GARD Programmable Single Function PLC RFL GARD SFPLC 1

Chapter 1. Introduction. Additional Documentation

GFM TIO GFC TIO. GFM with TIO Mounted. GFC with TIO Mounted TOTALIZER INPUT/OUTPUT FLOW MONITOR/CONTROLLER. Design Features

IDM DATA ACQUISITION SYSTEM

Products for DeviceNet

2. Site Planning lists the prerequisites and physical requirements for installing the 289H M LSS monitor.

MODEL SIB-V245 / V453

Technical Requirements for Supply of REMOTE TERMINAL UNIT (RTU)

XE 900: Fastest EPIC board now available with Windows XPe

Bedrock OSA Features and Benefits

T1K MODBUS Base Controller Specifications

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

PAC BI-DP BIM and 8701-CA-BI Carrier

PROGRAMMABLE MESSAGE DISPLAYS

VersaMax Micro and Nano Technical Product Presentation

RADIAN TPCMQ24 SERIES 24VDC Input 1RU Rack-Mount DC-DC Front-Ends 1000W and 1200W 1000W INDUSTRIES & APPLICATIONS

Communications guide. Line Distance Protection System * F1* GE Digital Energy. Title page

Prisma II Platform. Optoelectronics

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

H704-42(H)(E), H704-42/1(H)(E)

D20/D200 TM Substation Controller

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

Carbon Monoxide Sensor - ModBus

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

Type IBS EVA BASIC IBS EVA ADDITION 1 IBS EVA ADDITION 2 IBS SIG PART 2 UM IBS SIG PART 2 UM E. length: 50 mm acc. to RS x 9-pin D-SUB

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1

I/A Series HARDWARE Product Specifications

Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

Three Phase Systems-International PC302-I/MTD

Expanding the Basic GL7000 Configuration

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Overview. The DIN-RS232 has three primary functions: Isolated parallel RS-232 interface Fused power distribution Animatics peripheral expansion bus

PLC-5 Programmable Controllers Comparison

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

Raising the standard Upgrading the Series 90-30

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

Measurement Systems Datascan Installation and User Guide

Meridian 1 Fiber Remote Multi-IPE Interface Description, installation, and maintenance

SEL-2411 Programmable Automation Controller

Automationdirect.com. D i r e c t L o g i c S D S N e t w o r k M a s t e r. S m a r t D i s t r i b u t e d. S y s t e m M o d u l e

Control Indicator Module (CIM) - DNP3 Communications Protocol - TECHNICAL MANUAL

Transcription:

GE Digital Energy D20 Status Input Module Overview The D20 Status module is composed of two detachable modules, WESTERM D20 S and WESDAC D20 S. The bottom module, WESTERM D20 S, is where all field wirings are terminated. The top module, WESDAC D20 S, processes the data acquired and communicates this to the main D20 processor, see Figure 2. The WESTERM D20 S module is the termination for the WESDAC D20 S status input module. All field, I/O, and power terminations for the WESDAC D20 S are made on the WESTERM D20 S. Up to 64 digital inputs can be accommodated on the compression type terminations. Through the use of voltage dropping resistors, inputs in the range of 12 VDC to 130 VDC can be handled. Capacitors and varistors are equipped to provide Surge Withstand Capability (SWC) as well as impulse protection on all field inputs. The inputs are separated into 8 groups of 8 status inputs each. Each group has its own common return and is electrically isolated from the other groups. Inputs are provided with two compression type terminals for field connections. All inputs are bipolar, thus accommodating positive and negative ground systems. Each group can be configured with a group common or for contact wetting. The contact wetting can be supplied either from the input to the WESDAC D20S or from an external supply. The wetting supply is fused. Two DB 9 connectors are provided to allow daisy chaining of the D.20 links. The link provides the communication channel over which the main D20 CPU processor, the WESDAC D20 M, can communicate with the WESDAC D20 S. Power for the WESDAC D20 S is also provided over the same cable assembly. The power is fused and filtered by passive components on the WESTERM D20S. A single DB 9 connector is provided for the WESMAINT D20 maintenance port. This port allows communications between a VT 100 terminal or emulator, and the WESDAC D20 S. Module input data as well as diagnostic information can be passed over the maintenance port. The address jumper block for the WESDAC D20 S is located on the WESTERM D20 S. The address on the jumper block corresponds to the module s slave address on the D.20 link. The WESDAC D20 S is physically mounted on and electrically connected to the WESTERM D20 S through three 40 pin connectors. The two modules are mounted on a 19 inch rack and all field terminations are wired into the WESTERM D20 S. Only passive components are mounted on the WESTERM D20 S leaving all the active components on the WESDAC D20 S. This arrangement simplifies in field repair of the unit since the WESDAC D20 S can be replaced without disturbing any of the field wiring. Efficient, Cost Effective I/O Solutions The I/O modularity allows for efficient distributed I/O installations - minimizing wiring and enclosure requirements; this eliminates panel and reduces cost The active/passive design of the WESDAC/ WESTERM I/O modules allows users to quickly test, commission, and troubleshoot via hot swappable WESDAC modules, without disturbing wiring connections; this significantly speeds up and simplifies maintenance activities Ease of Use To first time users, both the software configuration setup and hardware installations are trivial; this makes it simple to install and maintain the I/O modules Flexible and Reliable Operations The digital I/O module can be easily configured to accommodate different system point types such as single, double, transition or Form C counters D20S supports up to 64 discrete digital inputs that are bipolar and optically isolated I/O modules are available to be ordered with either a DNP3 communication protocol option or a Standard/ Redundant D.20 link option the D.20 link is a GE proprietary protocol g imagination at work

Distributed I/O Architecture The D20 Remote Terminal Unit (RTU) design is based on a distributedprocessing architecture including real-time data acquisition and control software. These I/O modules can be located close to the primary equipment being monitored and controlled as they receive and send data back to the master D20 main processor. SCADA Masters The I/O modules are intelligent modules that contain on-board microprocessors and are configured as slave devices to the D20 main processor. In the Figure 1 pictorial setup, specific I/O processing is distributed throughout the D20 RTU to the appropriate I/O modules. The I/O modules support two communication protocols: (1) DNP 3 protocol, and (2) high speed, high-level data link controller (D.20 Link, HDLC) protocol. The peripheral modules have serial communication ports and various types of field connections. The hardware construction of each remote I/O module type is similar (see Figure 2.) Figure 1: Simple architecture of I/O modules communicating to the D20 RTU Figure 2: Architecture of I/O logic and termination panels Acrylic Display Cover WESDAC Logic Panel WESTERM Terminal Panel Terminal Blocks Metal Mounting Plate 2 GEDigitalEnergy.com

Data Processing D20 status modules provide specialized processing and storing/buffering functions for digital inputs and pulse accumulator inputs by gathering data from field sources. This processing provides flexible, reliable, robust operation and is configurable on a per-point or per-system basis. Table 1: Input Processing TYPE Digital Input DESCRIPTION Software debouncing Chatter filtering Report limiting The D20S can accept up to 64 digital inputs, each of which can be configured from a downloaded database to be processed as one of the following: Status and alarm inputs Status inputs with change of state detection (COS) Sequence of events (SOE) using time-tagged COS Binary-Coded Decimal or parallel inputs Pulse accumulator or counter inputs Pulse duration inputs The 64 digital inputs are organized in eight groups of eight electrically isolated inputs, each group with a common return. Each input is photo-coupled. For the D.20 modules, communicating via HDLC, the microprocessor scans each input at one millisecond intervals and provides selectable debounce of 4 to 255 ms. Changes are time-tagged to a resolution of one millisecond and placed in a first in - first out (FIFO) buffer for transmission to the D20 main processor. Time-tagged changes are reported in chronological order. Non-time-tagged changes are placed in a separate FIFO buffer and reported upon request. Termination Types D20 Status module can be ordered with the following field termination options: Technical Specifications Table 3: D20S Specifications ITEM Processor Clock Memory DESCRIPTION 8 bit Freescale 68HC11 MPU 2 MHz MPU clock 32 KB EPROM 24 KB static RAM 512 bytes EEPROM Inputs 64 bipolar inputs in 8 groups of 8 Point Types Current Burden Scan Rate Debounce SOE Time Resolution Contact Wetting Overload Rating Status/alarm with COS detection SOE Form A or Form C pulse accumulator (16 bit binary counter) Binary coded decimal Pulse duration ±3 to ±6 ma per input 1.0 ms Selectable 0 to 255 ms 1.0 ms ±12, ±24, ±48, ±125 V Component Isolation Rating 1500 Vrms Dielectric Rating D.20 Link Ports 2 Maintenance Port Power Requirements 500 VDC (common mode to ground) 1000 VDC 9600 baud, RS-232 20-60 VDC, 3 W typical Size 19" x 5.25" x 2.5" LED Indicators Common LEDs For each input point, a RED LED to indicate the ON/OFF state of the point Table 2: D20 Status Input Termination Types PERIPHERAL I/O SUPPORT TERMINATION D20S 64 digital inputs, standard version Compression D20SD 64 digital inputs, standard version DB25 D20SX 64 digital inputs, standard version Disconnect D20SB 64 digital inputs, standard version Barrier D20SZ 64 digital inputs, high-voltage version HV Compression GEDigitalEnergy.com 3

Ordering D20S System Components Please note 1. For the rules regarding the combination of various options to build an order code, visit the online web: http://store.gedigitalenergy.com/viewprod.asp?model=d20s 2. This ordering guide should ONLY be used with reference to the product documentation and it is assumed the user has read those documents. The ordering guide is for the use of experienced users who have extensive knowledge in the area and the products. 3. The order defined in the ordering guide may not be final and can only be accepted once GE has reviewed and accepted the order. This document is only meant as a guide and by no means will portray the final order. 4. GE reserves the rights to change or modify the document without notice. The user is responsible to contact GE before placing an order to ensure the accuracy of the order code built. D20S - * * * * * * * Description Equivalent Legacy # D20S Termination 1 D20S LV (20-60VDC or D.20 Power) Compression Termination 517-0165 B D20S LV (20-60VDC or D.20 Power) Compression Termination (Conformal Coated) 517-0165-CC 2 D20SD LV (20-60VDC or D.20 Power) DB25 Termination 517-0179 C D20SD LV (20-60VDC or D.20 Power) DB25 TERMINATION (Conformal Coated) 517-0179-CC 3 D20SX LV (20-60VDC or D.20 Power) Compression/Disconnect Termination 517-0219 D D20SX LV (20-60VDC or D.20 Power) Compression/Disconnect Termination (Conformal Coated) 517-0219-CC 4 D20SB LV (20-60VDC or D.20 Power) Barrier Termination 517-0327 E D20SB LV (20-60VDC or D.20 Power) Barrier Termination (Conformal Coated) 517-0327-CC 5 D20SDI LV (20-60VDC or D.20 Power) 24V Isolated Inputs, DB25 Termination 517-0330 6 D20SDI LV (20-60VDC or D.20 Power) 48V Isolated Inputs, DB25 Termination 517-0331 7 D20SDI LV (20-60VDC or D.20 Power) 125V Isolated Inputs, DB25 Termination 517-0262 M WESTERM D20 OSD LV (20-60VDC or D.20 Power) 517-0252 8 D20SZ HV (40-150VDC Power) 48V Wetting Compression Termination 517-0241 G D20SZ HV (40-150VDC Power) 48V Wetting Compression Termination (Conformal Coated) 517-0241-CC 9 D20SZ HV (40-150VDC Power) 110V Wetting Compression Termination 517-0249 H D20SZ HV (40-150VDC Power) 110V Wetting Compression Termination (Conformal Coated) 517-0249-CC A D20SZ HV (40-150VDC Power) 220V Wetting Compression Termination 517-0266 I D20SZ HV (40-150VDC Power) 220V Wetting Compression/Disconnect Termination 517-0366 K D20SZ HV (40-150VDC Power) 24V Wetting Compression Termination 517-0377 D20S Status Wetting U Status Wetting Not Required 1 12V Status Wetting 2 24V Status Wetting 3 48V Status Wetting 4 130V Status Wetting D20 PCommon U PCommon Chip Not Required 1 PCommon 212 2 PCommon 213 3 PCommon 220 4 PCommon 221 5 PCommon 300 6 PCommon 301 7 PCommon 305 8 PCOMMON 306 (D20A, D20S and D20K) D.20 Cable U Cable Not Required 1 D.20 Cable 12 Inches Long 2 D.20 Cable 18 Inches Long 3 D.20 Cable 24 Inches Long 4 D.20 Cable 36 Inches Long 5 D.20 Cable 48 Inches Long 6 D.20 Cable 72 Inches Long 7 D.20 Cable 96 Inches Long 8 D.20 Cable 120 Inches Long D.20 Terminator U D.20 Terminator Not Required 1 D.20 Terminator (One Required per D.20 Link) D.20 Duct Panel U Duct Panel Not Required 1 Cable Duct Panel, Tie Wrap Connections 2 Two Cable Duct Panels, Tie Wrap Connections 3 Cable Duct Panel, No Through Holes 4 Two Cable Duct Panels, No Through Holes 5 Cable Duct Panel, Through Holes at Each End 6 Two Cable Duct Panels, Through Holes at Each End Second D.20 LAN U Second D.20 LAN Port Not Required A WESDAC D20 ASK D.20 I/F 4 GEDigitalEnergy.com

D20S Spare Components Please note 1. For the rules regarding the combination of various options to build an order code, visit the online web: http://store.gedigitalenergy.com/viewprod.asp?model=d20s+spare+parts 2. This ordering guide should ONLY be used with reference to the product documentation and it is assumed the user has read those documents. The ordering guide is for the use of experienced users who have extensive knowledge in the area and the products. 3. The order defined in the ordering guide may not be final and can only be accepted once GE has reviewed and accepted the order. This document is only meant as a guide and by no means will portray the final order. 4. GE reserves the rights to change or modify the document without notice. The user is responsible to contact GE before placing an order to ensure the accuracy of the order code built. D20S - * * * * * * * * * Description Module Type U None (Need ONLY RNET Voltage Adapter Packs) 3 DNP 3 I/O Module D WESDAC Module T WESTERM Module Input Voltage to Module U None (Need ONLY RNET Voltage Adapter Packs) H High Voltage (40-150VDC) L Low Voltage (20-60 VDC or D.20 Link Power) Termination Type U None B Barrier Termination Type D DB25 Termination Type P Compression Termination Type X Compression/Disconnect Terminatiion Type Environmental Protection U None C Conformal Coat E Epoxy-Conformal Coat D20S RNET Type U None G Built-in RNETS I Isolated Built-in RNETS S Selectable RNETS D20S RNET Voltage U None 012 12V Adapter Packs 024 24V Adapter Packs 048 48V Adapter Packs 110 110V Adapter Packs 125 125V Adapter Packs 220 220V Adapter Packs D.20 Link U None R WESTERM Redundant D.20 Link & Dual Power Supply Option (540-0313) L WESDAC Redundant D.20 Link & Dual Power Supply Option (540-0207) S Standard D.20 Link [ For Module type T, or D] PCOMMON U None 1 PCommon 212 (SBA0001/00) 2 PCommon 213 (SBA0003/00) 3 PCommon 220 (SBA0004/00) 4 PCommon 221 (SBA0007/00) 5 PCommon 300 (SBA0005/00) 6 PCommon 301 (SBA0006/00) 7 PCommon 305 (SBA0009/00) 8 PCOMMON 306 (P010-0 VER.306) DNP3 DI Input Points U None A Single Point B Double Point C Transition Counter D Form C Counter GEDigitalEnergy.com 5

D20S Spare Cross-Reference LEGACY PART NUMBER AND DESCRIPTION SMART CATALOG NUMBER PREFIX AND DESCRIPTION WESTERM MODULES - LEGACY PART NUMBER WESTERM MODULES - NEW PART NUMBER PREFIX (517-0165) - WESTERM D20S TYPE 1 VERSION 1 (D20S-TL-P-U-S)- D20S LV (20-60VDC or D.20 Power) Compression Termination (517-0165-CC) - WESTERM D20S TYPE 1 VERSION 1 - Conformal Coated (D20S-TL-P-C-S)- D20S LV (20-60VDC or D.20 Power) Compression Termination, Conformal Coated (517-0165-ECC) - WESTERM D20S TYPE 1 VERSION 1 - Epoxy Conformal Coated (D20S-TL-P-E-S)- D20S LV (20-60VDC or D.20 Power) Compression Termination, Epoxy Conformal Coated (517-0179) - WESTERM D20 SD (D20S-TL-D-U-S)- D20SD LV (20-60VDC or D.20 Power) DB25 Termination (517-0179-CC) - WESTERM D20 SD - Conformal Coated (D20S-TL-D-C-S)- D20SD LV (20-60VDC or D.20 Power) DB25 Termination, Conformal Coated (517-0179-ECC) - WESTERM D20 SD - Epoxy Conformal Coated (D20S-TL-D-E-S)- D20SD LV (20-60VDC or D.20 Power) DB25 Termination, Epoxy Conformal Coated (517-0179-ECC) (517-0219) - WESTERM D20SX W/TB PLUGS (D20S-TL-X-U-S)- D20SX LV (20-60VDC or D.20 Power) Compression/Disconnect Termination (517-0219-CC) - WESTERM D20SX W/TB PLUGS - Conformal Coated (D20S-TL-X-C-S)- D20SX LV (20-60VDC or D.20 Power) Compresison/Disconnect Termination Conformal Coated (517-0219-ECC) - WESTERM D20SX W/TB PLUGS - Epoxy Conformal Coated (D20S-TL-X-E-S)- D20SX LV (20-60VDC or D.20 Power) Compresison/Disconnect Termination Epoxy Conformal Coated (517-0219-ECC) (517-0327) - WESTERM D20SB (D20S-TL-B-U-S)- D20SB LV (20-60VDC or D.20 Power) Barrier Termination (517-0327-CC) - WESTERM D20SB - Conformal Coated (D20S-TL-B-C-S)- D20SB LV (20-60VDC or D.20 Power) Barrier Termination, Conformal Coated (517-0327-ECC) - WESTERM D20SB - Epoxy Conformal Coated (D20S-TL-B-E-S)- D20SB LV (20-60VDC or D.20 Power) Barrier Termination, Epoxy Conformal Coated (517-0330) - WESTERM D20 SDI, 24V (D20S-TL-D-U-I-024)- D20SDI-24 LV (20-60VDC or D.20 Power) DB25 Termination (517-0331) - WESTERM D20 SDI, 48V (D20S-TL-D-U-I-048)- D20SDI-48 LV (20-60VDC or D.20 Power) DB25 Termination (517-0262) - WESTERM D20 SDI, 125V (D20S-TL-D-U-I-125)- D20SDI-125 LV (20-60VDC or D.20 Power) DB25 Termination (517-0252) - WESTERM D20 OSD (D20S-TM-D-U-G-048)- D20 OSD LV (20-60VDC or D.20 Power), DB25 Termination, Redundant D.20 and PS Input (517-0241) - WESTERM D20 SZ 48V (D20S-TH-P-U-G-048)- D20SZ HV (40-150 VDC Power) Compression Termination (517-0241-CC) - WESTERM D20 SZ 48V - Conformal Coated (D20S-TH-P-C-G-048)- D20SZ HV (40-150 VDC Power) Compression Termination, Conformal Coated (517-0249) - WESTERM D20 SZ 110V (D20S-TH-P-U-G-110)- D20SZ HV (40-150 VDC Power) Compression Termination (517-0249-ECC) - WESTERM D20 SZ 110V - Epoxy Conformal Coated (D20S-TH-P-E-G-110)- D20SZ HV (40-150 VDC Power) Compression Termination, Epoxy Conformal Coated (517-0266) - WESTERM D20 SZ2 (110/220V) (D20S-TH-P-U-S)- D20SZ HV (40-150 VDC Power) Compression Termination (517-0366) - WESTERM D20 SZ WITH PLUGS(48V) (D20S-TH-X-U-G-048)- D20SZ HV (40-150 VDC Power) Compression/Disconnect Termination (517-0377) - WESTERM D20 SZ WITH PLUGS (24V) (D20S-TH-X-U-G-024)- D20SZ HV (40-150 VDC Power) Compression Termination WESDAC MODULES - LEGACY PART NUMBER WESDAC MODULES - NEW PART NUMBER PREFIX (507-0101) - WESDAC D20S TY1 VER 1 (D20S-DL-U-U-U)- WESDAC D20S LV (507-0101-CC) - WESDAC D20S TY1 VER1 - Conformal Coated (D20S-DL-U-U-C)- WESDAC D20S LV Conformal Coated (507-0103) - WESDAC D20S HV2 (D20S-DH-U-U-U)- WESDAC D20S HV (507-0103-CC) - WESDAC D20S HV2 - Conformal Coated (D20S-DH-U-U-C)- WESDAC D20S HV Conformal Coated (507-0103-ECC) - WESDAC D20S HV2 - Epoxy Conformal Coated (D20S-DH-U-U-E)- WESDAC D20S HV Epoxy Conformal Coated DNP I/O MODULE SPARES - LEGACY PART NUMBER DNP I/O MODULE SPARES - NEW PART NUMBER PREFIX (507-0301) - DNP I/O MODULE - DIGITAL INPUT (D20S-3L-U-U-U)- WESDAC D20S LV, DNP3 Communications (507-0301-CC) - DNP I/O MODULE - DIGITAL INPUT - Conformal Coated (D20S-3L-U-U-C)- WESDAC D20S LV, DNP3 Communications, Conformal Coated (507-0303) - DNP I/O MODULE - DIGITAL INPUT HV (D20S-3H-U-U-U)- WESDAC D20S HV, DNP3 Communications (507-0303-CC) - DNP I/O MODULE - DIGITAL INPUT HV - Conformal Coated (D20S-3H-U-U-C)- WESDAC D20S HV, DNP3 Communications, Conformal Coated D20S RNET ADAPTER PACKS D20 RNET OPTIONS - NEW PART NUMBER (245-0009) - 12V Digital Input Adapter (D20S-U-U-U-U-U-012-U-U-U) - 12 V Digital Input Adapter - Set of 25 (245-0030) - 24V Digital Input Adapter (D20S-U-U-U-U-U-024-U-U-U) - 24 V Digital Input Adapter - Set of 17 (245-0029) - 24V Digital Input Adapter (D20S-U-U-U-U-U-024-U-U-U) - 24 V Digital Input Adapter - Set of 8 (245-0004) - 48V Digital Input Adapter (D20S-U-U-U-U-U-048-U-U-U) - 48 V Digital Input Adapter - Set of 25 (245-0012) - 110V Digital Input Adapter (D20S-U-U-U-U-U-110-U-U-U) - 110 V Digital Input Adapter - Set of 24 (530-0133) - 125V Digital Input Adapter (D20S-U-U-U-U-U-125-U-U-U) - 125 V Digital Input Adapter - Set of 25 (530-0133) - 220V Digital Input Adapter (D20S-U-U-U-U-U-220-U-U-U) - 220 V Digital Input Adapter - Set of 24 GE Digital Energy 650 Markland St. Markham, ON Canada L6C 0M1 +1 877-605-6777 (toll free in North America) +1 678-844-6777 (direct number) gedigitalenergy@ge.com GEDigitalEnergy.com g imagination at work Copyright 2014, General Electric Company. GE and the GE monogram are trademarks of the General Electric Company. GE Digital Energy reserves the right to make changes to specifications of products described at any time without notice and without obligation to notify any person of such changes. GEA-12793(E) English 140627