FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING)

Similar documents
FIBER OPTIC A/B/C/D SWITCH (LATCHING)

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

RS-232/RS-422 Optical Isolator

DRD-4 DRD-4 JULY 1992 FX140A CUSTOMER SUPPORT INFORMATION

PC Media Converter, Switching (TP-TX/FX)

T1 Fold (2KM) SEPTEMBER 1995 MT612A-ST MT612AE-ST. T1 - Fold CUSTOMER SUPPORT INFORMATION

3174/3274 I-Mux FEBRUARY 1993 MX330A-C MX330A-D CUSTOMER SUPPORT INFORMATION

USB USB Data Transfer

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

10/100 Autosensing PC Media Converter

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION

Four Port RS-232 Serial Interface

3270 Repeater Fiber 3270 Repeater UTP 3270 Repeater Fiber RJ Repeater UTP RJ45

Computertop TV-I. Computertop TV-I SEPTEMBER 1993 AC451A CUSTOMER SUPPORT INFORMATION

Dual Port RS-232 Serial Interface

Express Ethernet Switch: LB8422A-US LB8421A-US LB8424A-US

Personal MiniHub. Personal MiniHub RX LINKPORT #AUI PORT 5 UP LINK PWR JUNE 2001 LE2650A LE2650AE CUSTOMER SUPPORT INFORMATION

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

DB9 Microdriver CUSTOMER SUPPORT INFORMATION JULY 1994 ME792A ME793A ME794A

Connects 1000BASE-T twisted-pair to 1000BASE-SX/LX fiber.

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

Giga-MiniMc TX & RX USER MANUAL

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

SCSI Fiber Optic Extender

FiberLinX Modules Hardware Installation Manual

Allworx Tx 92/24 Telephone Expander Installation Guide

Copyright Black Box Corporation. All rights reserved.

Rack Input Module Installation Instructions

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

1.0 Description. 2.0 Unpacking. 3.0 Installation

Installer/User Guide

INSTALLATION AND OPERATIONS MANUAL

Infosystem Remote Touchscreen Installation Instructions

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

About PoE Compact Media Converters

7800 SERIES S7810B Multi-Drop Switch Module

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

CrystalLink USB 2.0 CAT5 INSTALLATION AND OPERATIONS MANUAL. Part Number CLK-1U4TP-100M/PE Stancliff Road Phone: (281)

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

Model Bulk Sampling Scale. User s Manual

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

McPC/Giga-MediaLinX. (PCI and Low Profile PCI Version) 10/100/1000 Mbps. Operation Manual

Giga-MiniMc TX/FX Giga-MiniMc TX/SFP. Operation Manual

ADL-100 Operator s Manual

These tiny media converters are perfect for bringing fiber to the desktop.

Monarch 9414 Printer. TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved.

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

Connectivity Peripherals User s Guide. Point 510 Point 1600

Choose from four different ways to power these hardened media converters.

Multi-Power Miniature Media Converter 10/100/1000

MiniMc TP-TX/FX MiniMc TP-TX/SFP. Operation Manual

NSD/M1 Installation Instructions

TELink FLASH. Model 700a. Installation and Operation Instructions. Magic On Hold is a Registered Service Mark and Trademark of Avaya Communications

Quick Start Installation Guide

Cat. No KT/B. Installation Data

Operator s Handbook. Monarch FreshMarx 9417 Food Freshness System. TC9417OH Rev. AE 1/ Avery Dennison Corp. All rights reserved.

Modular Media Converter Installation Guide (includes 10 Mbps Ethernet, 100 Mbps Fast Ethernet and Protocol-Independent Fiber Mode Conversion Modules)

Industrial SFP/SFP Multi-Power Mode Converter

International Headquarters

BEETLE /Fusion Compact. Installation Guide

IE-MediaChassis/1. Operation Manual

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules

INSTALLATION INSTRUCTIONS

NCH-1000 (Multiple Breaker Types) Installation Instructions

AdderLink X50 USB. User.Guide. contents ADDER LOCAL POWER OUT LINK TO REMOTE

Mini Wireless Barcode Reader Quick Guide

CHS 7Ci. Bluetooth Cordless Barcode Scanner. Quick Start Guide

TELink 700 FLASH INSTALLATION AND OPERATION MANUAL

Buffered Data Broadcast

User s Guide CPSMM Dual-Slot Master Management Module CPSMM Single-Slot Expansion Management Module

Verify Package Contents

2DScan TM Barcode Scanner

CANADIAN D.O.C. WARNING

SYSNet QS7700A Network Interface ControlBus Module for BCS7700

Mobile UHF Reader. Quick Guide. For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N:

Add 10/100 copper ports to a High Density Media Converter Chassis.

BEETLE MSR Module. Swipe Card Reader. for BA7x. User Guide

PETROL (P-SERIES), TTL, INSERTION READER TECHNICAL REFERENCE MANUAL

Converts any fiber optics type interface to any other fiber optics type interface.

LH1350C-xx-R3. Part Number. Port One - Duplex Fiber-Optic 100Base-FX LH1350C-ST-R3 LH1350C-SC-R3

Keyboard-Line Power Adapter for ServSwitch Family

imediachassis Series imediachassis/20 imediachassis/6 imediachassis/3 Operation Manual

TMS-3000 Controller. Release Notes, Version GTS V2.2.0, Year 2000 Enhancement GDC 036R , Issue 1, November General DataComm, Inc.

Basler ace QUICK INSTALLATION GUIDE

2U AUTO-BYPASS SWITCH

Black Box Tech Support: FREE! Live. 24/7.

User s Guide CPSMC Single-Slot Point System Chassis with Internal Power Supply

High Density Media Converter System II 20-Slot Rackmount Chassis

Keyboard Display Unit

IE-Giga-MiniMc. Operation Manual. FCC Radio Frequency Interference Statement. Limited Lifetime Warranty

Copyright Black Box Corporation. All rights reserved.

Model Bulk Sampling Scale. Setup, Configuration and Calibration Manual

10/100/1000 Auto Bypass Switch

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A

adynamo Technical Reference Manual PART NUMBER October 2014

Item No.: 4SK108. User Manual. Thank you for choosing The Original Dash Cam. This manual offers detailed information on how to operate TODC (The

NETGEAR, Inc Great America Parkway Santa Clara, CA USA. April 2004

LongView Wireless. Installer/User Guide

CANADIAN D.O.C. WARNING

Transcription:

JANUARY 2008 Model# SW1006A FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING) CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724- INFORMATION 746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com

FCC STATEMENT FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada. Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le Industrie Canada. Page 2

Contents CONTENTS Chapter Page 1. Specifications... 4 2. Introduction. 5 3. Installation.. 6 4. Troubleshooting.. 6 Page 3

Chapter 1: Specifications Specifications Connectors (5 pairs) ST, (1) 3.5-mm power input Also available with SC connectors Please call! Data Rates Transparent to signal rates, wavelengths, & formats Switching Speed less than 1 sec typical Sensitivity 750 to 1450 nanometers Optical Loss less than 3.0 db typical per FOTP-171 method B1 Compatibility 62.5/125 µm multimode fiber Crosstalk less than -45 db typical per FOTP-42 Grounding None required Approvals UL, CE, and PSE (power supply) Operating Temperature 14 to 149ºF (-10 to +65ºC) Relative Humidity Tolerance 10 to 95%, non-condensing Page 4

Mean Time Between Failures 100,000 hours or 1,000,000 cycles Power 100-240 VAC, 50/60 Hz wall-mount power supply, 5 VDC out Size 2.5 H x 8 W x 6.3 D (6.4 x 20.3 x 16 cm) Weight 4 lb. (1.8 kg) Chapter 2: Introduction Introduction The non-latching Fiber Optic A/B/C/D Switch is a fullduplex, optical 4 port switch. It can be used to connect one workstation to four different networks (one at a time) or to other remote devices. A front panel rotary style knob allows the user to select which of four ports (A, B, C or D) is connected to the COMMON port on the switch. The switch operates using a unique all-optical micro-mirror movement. When you turn the rotary knob on the front of the switch to select a network, the internal micro-mirror movement redirects the optical beam from one network port to another network port by rotating a miniature mirror. This technique eliminates the need to convert optical signals to electronic signals to for switching and it is therefore transparent to data rates and protocols. This switch is perfectly suited for use as a fall-back switch when a pre-determined connection is desired in the event of a power failure. You should use a latching fiber optic switch like Model # SW1005A for applications requiring a switch that maintains the selected connection during the loss of AC power. Latching switches use power only for switching to the selected connection. No power is required to pass data through the switches. Page 5

Chapter 3: Installation Installation Place the switch in a convenient stable location and connect the power supply unit to a reliable source of AC power that meets the requirements shown in the Specifications section of this manual. This switch is ideal for use in fall-back applications where a pre-determined connection is desirable in the event of a power failure. Connect the two fiber leads from the device to be shared to the switch port labeled COMMON. Connect the A port to the network or device to which you want to be connected if power is lost. Connect the remaining networks or devices to the ports labeled B, C, and D. Your installation of this switch is now complete. Chapter 4: Troubleshooting Troubleshooting If the Fiber Optic A/B/C/D Switch fails to operate, check the following before calling for technical support. 1. Ensure that the power supply connected to a power source and to the switch. 2. Check the fiber optic connectors for proper connections to the correct ports of the switch. 3. Operate the switch knob to verify that it s tightly secured to the switch shaft and does not spin loosely. 4. Verify the integrity of the fiber optic leads by replacing a suspect lead with a spare. Page 6

Notes: Fiber Optic A/B/C/D Switch (non-latching) Page 7

Copyright 2007 Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746