Deployment of VMware Infrastructure 3 on Dell PowerEdge Blade Servers

Similar documents
Deployment of VMware ESX 2.5.x Server Software on Dell PowerEdge Blade Servers

Deployment of VMware ESX 2.5 Server Software on Dell PowerEdge Blade Servers

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

VMware Infrastructure 3.5 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

Microsoft SharePoint Server 2010 on Dell Systems

Dell PowerVault NX1950 configuration guide for VMware ESX Server software

Reference Architecture for Dell VIS Self-Service Creator and VMware vsphere 4

VMware Infrastructure 3.5 Update 2 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage

vstart 50 VMware vsphere Solution Specification

Shared LOM support on Modular

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

VMware ESX Server Software for Dell PowerEdge Servers. Deployment Guide. support.dell.com

Dell TM PowerVault TM Configuration Guide for VMware ESX/ESXi 3.5

A Dell Technical White Paper Dell Virtualization Solutions Engineering

Compatibility Matrix for VMware Infrastructure 3 and Dell PowerEdge Systems

Dell 1741M Converged Network Adapter FCoE Boot from SAN Guide

Four-Socket Server Consolidation Using SQL Server 2008

Minimum Hardware/Software Requirements (For details, see below)

Deploying Solaris 11 with EqualLogic Arrays

A Dell technical white paper By Fabian Salamanca, Javier Jiménez, and Leopoldo Orona

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays

A Performance Characterization of Microsoft SQL Server 2005 Virtual Machines on Dell PowerEdge Servers Running VMware ESX Server 3.

Dell TM with Oracle Database Enterprise Edition Running Windows Server 2008

Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers

Dell PowerEdge with Oracle Database 10g x86-64 and RAC on Enterprise Linux AS 5 U2 version 4.1 Updated 01/30/2009

DELL Reference Configuration Microsoft SQL Server 2008 Fast Track Data Warehouse

SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper

Deployment of Dell M8024-k Blade Switch in Simple Mode with Cisco Nexus 5k Switch

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE

Lifecycle Controller 2 Release 1.0 Version Readme

INFOBrief. Dell PowerEdge Key Points

A Principled Technologies deployment guide commissioned by QLogic Corporation

Active System Manager Release 8.2 Compatibility Matrix

PowerConnect 'HOO_3RZHU&RQQHFW. Key Points. Product Description

vstart 50 VMware vsphere Solution Overview

Using Dell Repository Manager with Dell OpenManage Essentials

Teradici APEX 2800 for VMware Horizon View

A Dell Interoperability Whitepaper Victor Teeter

Configuring Direct-Connect between a DR Series System and Backup Media Server

Proactive maintenance and adaptive power management using Dell OpenManage Systems Management for VMware DRS Clusters

Performance Comparisons of Dell PowerEdge Servers with SQL Server 2000 Service Pack 4 Enterprise Product Group (EPG)

Validated Components List for EqualLogic PS Series SANs

Installing Dell OpenManage 4.5 Software in a VMware ESX Server Software 2.5.x Environment

Lifecycle Controller with Dell Repository Manager

VMware Virtual Infrastructure 3.x Software for Dell PowerEdge Systems. Release Notes. support.dell.com

White Paper. Dell Reference Configuration

EqualLogic Storage and Non-Stacking Switches. Sizing and Configuration

Using Dell Repository Manager to Update Your Local Repository

PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules

Best Practices for Mixed Speed Devices within a 10 Gb EqualLogic Storage Area Network Using PowerConnect 8100 Series Switches

Quadport Capable Hardware for the M1000e Modular Chassis

Dell EMC Networking VxRail Networking Quick Guide

VMware ESX Server 2.1 Software for Dell PowerEdge Servers. Deployment Guide. support.dell.com

Dell Reference Configuration for Large Oracle Database Deployments on Dell EqualLogic Storage

Access Control Policies

Virtual Exchange 2007 within a VMware ESX datastore VMDK file replicated

Dell Wyse Datacenter for VMware Horizon View Cloud Pod Architecture

EMC Virtual Architecture for Microsoft SharePoint Server Reference Architecture

Dell Server Migration Utility (SMU)

Dell EMC Networking vsan vsphere Networking Quick Guide using Dell OS 9

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND ISCSI INFRASTRUCTURE

Microsoft Lync Server 2010 on Dell Systems. Solutions for 500 to 25,000 Users

Running Milestone XProtect with the Dell FS8600 Scale-out File System

Pass-Through Technology

Active System Manager Version 8.0 Compatibility Matrix Guide

Console Redirection on VMware ESX Server Software and Dell PowerEdge Servers

Implementing SharePoint Server 2010 on Dell vstart Solution

Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets

FluidFS Antivirus Integration

Improving Blade Economics with Virtualization

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays

VMware VAAI Integration. VMware vsphere 5.0 VAAI primitive integration and performance validation with Dell Compellent Storage Center 6.

HP BladeSystem c-class Ethernet network adapters

NICs (dedicated for iscsi): NIC Driver version

Brocade 20-port 8Gb SAN Switch Modules for BladeCenter

OpenManage TM Integration for VMware vcenter FAQ

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager

Database Solutions Engineering. Best Practices for running Microsoft SQL Server and Microsoft Hyper-V on Dell PowerEdge Servers and Storage

Virtualization Support in Dell Management Console v1.0

Business-Ready Configuration for Microsoft Hyper-V R2 on Dell PowerEdge R-Series Servers with EqualLogic Storage

VMware VMmark V1.1 Results

12/04/ Dell Inc. All Rights Reserved. 1

Storage Consolidation with the Dell PowerVault MD3000i iscsi Storage

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE VSAN INFRASTRUCTURE

Upgrade to Microsoft SQL Server 2016 with Dell EMC Infrastructure

Competitive Power Savings with VMware Consolidation on the Dell PowerEdge 2950

Using Lifecycle Controller to Configure UEFI Secure Boot and OS Deployment

iscsi Boot from SAN with Dell PS Series

Dell with Oracle Database 11g R2 on RHEL 6.3 & Oracle Linux 6.3 with Compatible Kernel

Cisco UCS Virtual Interface Card 1225

Reference Architecture for Microsoft Hyper-V R2 on Dell PowerEdge M- Series Servers with EqualLogic Storage

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

A Reference Architecture for SAP Solutions on Dell and SUSE

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager

Dell DCPPE-200. Dell PowerEdge Professional. Download Full version :

Setting Up Replication between Dell DR Series Deduplication Appliances with NetVault 9.2 as Backup Software

VMmark 3.0 Results. Number of Hosts: 2 Uniform Hosts [yes/no]: yes Total sockets/cores/threads in test: 4/112/224

EMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange Enabled by MirrorView/S

Transcription:

Deployment of VMware Infrastructure 3 on Dell PowerEdge Blade Servers The purpose of this document is to provide best practices for deploying VMware Infrastructure 3.x on Dell PowerEdge Blade Servers. The document describes various possible configurations when installing VMware Infrastructure 3.x along with the advantages and disadvantages for each configuration. November 2007 1 Dell Inc

Contents 1. Introduction... 3 2. Configuration Options... 3 2.1 Stand-alone and SAN Configurations... 3 2.2 Configuring the NICs... 6 2.3 Boot from SAN... 7 2.4 Embedded Switch vs. Pass-through... 7 2.5 VirtualCenter with PowerEdge 1855/1955... 8 3. Installing ESX Server Software... 8 4. Post Installation... 9 4.1 Setting up VLANs... 9 4.2 Fault tolerance when using an Ethernet switch module... 9 5. References:... 10 November 2007 2 Dell Inc

1. Introduction This document describes various configurations that are possible when installing VMware Infrastructure 3 on Dell PowerEdge 1855 and 1955 Blade Servers. Advantages and disadvantages for each configuration along with the steps to install are detailed. 2. Configuration Options 2.1 Stand-alone and SAN Configurations Dell has qualified VMware Infrastructure 3 software in two basic configurations. Blade servers can be used in a stand-alone mode (Figure 1), or they can be connected to a shared SAN through a fibre channel switch. For stand-alone configurations, in addition to one dual port embedded Gigabit Ethernet controller, an Intel or Broadcom dual port Gigabit Ethernet daughter card can be used to provide more network I/O capacity for virtual machines. Figure 1: VMware ESX Server Software - Stand-Alone Configuration on PowerEdge Blade Servers November 2007 3 Dell Inc

For SAN configurations, a Fibre Channel I/O daughter card and a Fibre Channel switch is required. Direct attached Fibre Channel is not supported. The Fibre Channel switch can either be an embedded Fibre Channel Switch Module or an external Fibre Channel switch which is connected through a Fibre Channel Pass-Through Module. Table 1 lists Dell supported Ethernet/Fibre Channel daughter cards and switch modules. Table 2 describes differences between the Fibre Channel Switch Module and the Pass-Through Fibre Channel Module. Ethernet Daughter Cards Table 1: Dell supported peripherals for blade servers Fibre Channel Daughter Cards Ethernet Switch Modules Fibre Channel Switch Modules Intel Dual Port PCI X Gigabit Ethernet controller Broadcom 5708 Dual Port PCI Express Ethernet controller Qlogic 2342M Qlogic QME 2462 Emulex LPe1105 PowerConnect 5316M Switch Module Cisco Catalyst Blade Switch 3030 Module Brocade Silkworm 3014 switch Brocade Silkworm 4016 4Gb switch McDATA 4314 switch McDATA 4416 FC switch Table 2: Fibre Channel switch module vs. Pass-through module Fibre Channel Switch Module Features four uplinks, that are 1/2/4 Gb/s auto-sensing Oversubscribed 10 to 4 (ten links to the blade server and four external up-links) Saves on rack space and cabling Pass-Through Fibre Channel Module Features ten 1/2/4 Gb/s uplinks, one for each blade server. Provides maximum Fibre Channel bandwidth and the ability to seamlessly utilize existing Fibre Channel investments Requires additional external switches, rack space and cabling The different qualified SAN configurations are shown in Figures 2, 3 and 4. Figure 2 shows blade servers connected to Dell EMC storage via redundant Fibre Channel Pass- Through modules. Pass-Through modules provide one connection for each blade server that is connected to external Fibre Channel switches. Figure 3 illustrates similar configuration but using redundant Fibre Channel Switch Modules available for Dell blade server chassis. Figure 4 shows the configuration when external Fibre Channel switches are used in addition to Fibre Channel switch modules in the chassis. All these configurations provide protection against failure at a storage processor, switch/passthrough or an HBA level. November 2007 4 Dell Inc

Figure 2: VMware Infrastructure Software - SAN Configuration on PowerEdge Blade Servers with Pass-Through Fibre Channel Modules Figure 3: VMware Infrastructure Software - SAN Configuration on PowerEdge Blade Servers with Fibre Channel Switch Modules November 2007 5 Dell Inc

Figure 4: VMware Infrastructure Software - SAN Configuration on PowerEdge Blade Servers with Fibre Channel Switch Modules and external Fibre Channel Switches A minimum of two Inter Switch Links (ISL) between two directly communicating switches is recommended. 2.2 Configuring the NICs In a SAN configuration, each PowerEdge (PE) 1855/1955 blade server configuration contains two embedded Gigabit Ethernet NICs (NIC0 and NIC1) and a dual port Fibre Channel daughter card. Networking can be configured in various ways for traffic isolation or redundancy. In a default installation, Service Console interface is connected to NIC0. A default network for Virtual Machines can be created at installation time that creates a network interface for virtual machines on NIC0. In order to better utilize the network bandwidth and to provide redundancy, the NICs can be configured as shown in Table 2. (this is not required in a stand-alone configuration): November 2007 6 Dell Inc

Table 2: NIC Configuration in a SAN environment Config NIC 0 NIC 1 1 2 Service Console Service Console and VMotion VMs and VMotion Fault Tolerance for VMs No Traffic Isolation? Moderate VM Performance? Acceptable if VMotion events are infrequent VMs No Good Acceptable Security? Moderate - VMotion on production network. Good -service console on private network. 3 4 Service Console and VMs NIC 0 and NIC1 teamed for Service Console, VM and VMotion traffic VMotion No Moderate Yes Moderate and flexible Acceptable if management traffic is infrequent and VMotion events are frequent Acceptable if VMotion events and management traffic are infrequent. Moderate - service console on production network. Good - By default VMotion and Service console share the same network. For improved security, VLANs must be used Service console traffic is encrypted by default. VMotion traffic is not encrypted. In order to help ensure effective and secure VMotion, it is highly recommended to have the VMotion NIC on a separate VLAN or separate physical NIC. For a NIC team all the team members need to be on the same broadcast domain. The two blade chassis switch modules need to be interconnected either using a direct link or an uplink to an external switch. 2.3 Boot from SAN ESX Server 3.x Software can be installed and booted from a LUN that resides in a SAN. This technique, known as Boot from SAN (BFS), enables diskless blade servers while consolidating and simplifying storage management. For more information, refer to the SAN Configuration Guide at www.vmware.com/support/pubs/vi_pubs.html. 2.4 Embedded Switch vs. Pass-through Customers can configure a PE 1855/1955 chassis either with an Ethernet switch module or with a pass-through Ethernet module. There are no special installation steps required for VMware ESX Server software to use the pass-through module. The table below lists the advantages of using either the switch or pass-through configurations. November 2007 7 Dell Inc

Table 3: Switch vs. Pass-through module Ethernet Switch Module Features six 10/100/1000BaseT Ethernet uplinks, providing full Layer 2 functionality Ethernet Pass-Through Module Features ten 1000BaseT Ethernet uplinks. Oversubscribed 10 to 6 (ten links to the blade server and six external up-links) VMotion traffic between blade server in the same chassis is enclosed within the switch Saves on rack space and cabling Provides maximum network bandwidth and the ability to seamlessly utilize existing network investments VMotion traffic affects external switches connected to the chassis Requires additional external switches, rack space and cabling 2.5 VirtualCenter with PowerEdge 1855/1955 The Dell PowerEdge 1855/1955 chassis can be configured with up to 10 blade servers. One of the blade servers can be installed with VirtualCenter and used as a management console to manage VMs running on other blade servers. For more information on VirtualCenter 2.0.x installation or upgrade, refer to Installation and Upgrade Guide at www.vmware.com/support/pubs/vi_pubs.html 3. Installing ESX Server Software For more detailed step by step instructions refer to Installation and Upgrade guide at www.vmware.com/support/pubs/vi_pubs.html and Deployment Guide - VMware Infrastructure 3.0.x for Dell PowerEdge Servers under Support Documents at www.dell.com/vmware. November 2007 8 Dell Inc

4. Post Installation Once the ESX Server software is installed using the above methods, the following post installation steps need to be executed. These steps are required only in a SAN configuration. 4.1 Setting up VLANs In all four NIC configurations, it is highly recommended to have the VMotion traffic in a separate VLAN. Deploying the VMotion interface to reside in a separate VLAN helps ensure that the VMotion traffic is secure. To set up VLANs in the Virtual Switches of the ESX Server 3.x software, refer to Server Configuration Guide at www.vmware.com/support/pubs/vi_pubs.html. To set up VLANs in a PowerConnect 5316M switch module, refer to the Dell PowerConnect 5316M System User Guide at http://support.dell.com. 4.2 Fault tolerance when using an Ethernet switch module This section describes NIC failover when using an Ethernet switch module in Configuration 4, or when using a Gigabit Ethernet daughter card for the stand-alone configuration. The ESX Server can be configured for network redundancy when the embedded Ethernet switch fails or when the external link(s) connected to the embedded switch fails. Ensure that the Ethernet switch has the latest firmware. For the PowerConnect 5316M Switch Module, use firmware version 1.0.0.38 or above. Network failure detection can be achieved either by using Link status or by using Beacon Probing. Link Status option relies on the connectivity status provided by the network adapter for failover. In the case of PowerConnect Ethernet 5316M switch module, the network adapter will report status as down, when the external switch has failed or when there is no external link (provide the firmware version is 1.0.0.38 or above and the NIC redundancy in the switch is configured appropriately). Beacon Probing option sends out and listens for beacon probes on all NICs in the team and uses this information to determine link failure. For more information on NIC Teaming and Beacon Monitoring refer to the Networking section in Server configuration Guide at www.vmware.com/support/pubs/vi_pubs.html. November 2007 9 Dell Inc

5. References 1. Deployment Guide VMware Infrastructure 3.0.x for Dell PowerEdge Servers at www.dell.com/vmware 2. Virtual Infrastructure 3 Installation and Upgrade Guide at www.vmware.com/support/pubs/vi_pubs.html 3. Dell PowerConnect 5316M System User Guide at http://support.dell.com 4. VMware ESX Server 3: 802.1Q VLAN Solutions at http://www.vmware.com/vmtn/resources/ 5. VMware Knowledgebase at http://kb.vmware.com THIS PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. Dell, the DELL logo, PowerEdge, and PowerConnect are trademarks of Dell Inc. VMware is a registered trademark of VMware, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own. 2006 Dell Inc. All rights reserved. Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. For more information, contact Dell Inc. November 2007 10 Dell Inc