Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Similar documents
OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Junos WebApp Secure 5.0 Hardware Guide

OPERATING MANUAL PDUAC3U SERIES AC POWER DISTRIBUTION UNITS

Power Supply Installation

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Replacing the Power Supply

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

16Hi HARDWARE INSTALLATION GUIDE

Power Supply and Fan Module Installation

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

TRC-190 User s Manual

PanelView Plus/VersaView CE Terminals and Display Modules

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Westell. Breaker Panel Technical Practice NPDRP1114

S4112-ON Series. Setup Guide

to 48V DC Power Supply

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Power Supply (48Vdc, 2.5A)

ASCO 920 Remote Control (RC) Switches

Breaker Panel Technical Practice NPDRP1114

QuickSpecs HP BladeSystem Breaker Panel

PV Rapid Shutdown device

VEP4600. Setup Guide

HomeWorks Remote Power Feed-Through Panels

Site Preparation CHAPTER

iconverter 2-Module Power Chassis

Specifications, Installation, and Operating Instructions

920 Remote Control (RC) Switches

Release Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location

Connecting Power and Ground

Cisco ASR 1004 Router Overview and Installation

INSTALLATION MANUAL SLI 50 INVERTER

PowerLogic High Density Metering System 1-Meter Enclosure

LVN5200A-R2, rev. 1, Hardware Installation Guide

Dell Networking S4100-ON Series. Set-Up Guide

Redundancy unit CP-A RU

S66 Series Electronic Fan Speed Control

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

GCI-5K INSTALLATION AND OPERATOR S MANUAL

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

QUICKSTART INSTALLATION INSTRUCTIONS

User Manual. Per Port Monitoring Models

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

ChromaFlex Chassis. Hardware Interface Manual

MINI-PS AC/10-15DC/8

Installation and Maintenance

D-Link Switch User Manual. Table of Contents

S5048F-ON. Set-up Guide

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Instructions

Digital Lighting Systems, Inc.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Follow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation

60103 Circuit Breaker

Quick Start Guide TS A

hp uninterruptible power system r12000 xr models installation instructions

PLC Racks IC697CHS782/783

STEP-PS/1AC/24DC/1.75

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

E-Series Site Preparation Guide

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

TRC-190 User s Manual

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

G5 PDU Installation Guide

R-LB R-LX Series Installation, Operation & Maintenance Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

PowerShield 8. Installation Manual

Installing the Cisco AS5400XM Universal Gateway

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

IPR-150 INSTALLATION GUIDE 150KVA Three-Phase Release 1.0

Auto-Transfer Rack Power Distribution Unit

NI PXIe-1062Q Power Supply Shuttle

HX WCS Indoor DAS Remote Unit Quick Installation Sheet

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

AI130 AIswitch Series 130 Chassis Installation Guide

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

MC 11 EB-2 Power supply cabinet with external bus, AC version

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation Manual Compact C-Shelf System

Transcription:

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 User Manual 1.1 Overview Telect s 80A, -48 Vdc Low-Voltage Disconnect (LVD) panel is a rack-mounted component with coil-operated contactors. These contactors disconnect the power system from the load and return when the system voltage falls below a preset level, protecting batteries and power circuits from damage. A compact 1 RU, dual-circuit panel configuration provides this vital capability in minimal rack space. Panel comes with factory-set disconnect voltages. Separate disconnect and closure voltages prevent rapid cycling of the LVD when the voltage is precisely at one of the control values. Side 1 and Side 2 use a pair of dual-hole lugs for input source and output feeds. Inputs, outputs, and ground are easily accessible on this total front access LVD panel. Features include: Dual-color LVD STATUS LEDs for each side Independent Side 1 and 2 operation Total front access (TFA) Lexan cover protects I/O terminals and lugs Occupies just 1 EIA RU of vertical space Fits 19 or 23 inch racks with either EIA or WECO spacing Output RTNs for Side 1 and Side 2 are diode-isolated from the input RTNs Figure 1-80LVD02 The LVDs are normally connected in series with the load, but may be connected in series with the battery as an option for exclusive battery protection. This protects the batteries from damage due Page 1

to discharge below the minimum recommended cell voltage levels during long-term power losses. See Figure 2. Figure 2 - LVD Connection Series When the voltage falls below the setpoint, the LVD control card interrupts the circuit between the battery or source bus and the loads connected to the power distribution unit (PDU), as shown in Figure 3. Figure 3 - LVD Control Card Interruption Page 2

The disconnect voltage is factory set at -39.0 Vdc and the closure is set for -47.0 Vdc. Separate disconnect and closure voltages prevent rapid cycling of the LVD when the voltage is precisely at one of the control values. Figure 4 - Status LVDs I/O Terminal Blocks are staggered to allow clearance between I/O lugs and conductors. Transparent Cover Top View Figure 5 - I/O Blocks and Clearance Page 3

1.2 Specifications Mechanical: Dimensions (nominal) without brackets Weight Material Finish Mounting Specifications: Width: 17.0 in. (431.8 mm) Height: 1.75 in. (44.5 mm) (1 RU) Depth: 7.5 in. (190.5 mm) ~ 12 lb. (5.4 kg) Cold-rolled steel Telect white powder coat 19 or 23 in. Terminal: Specifications: Input/Output Terminals Dual-hole compression lugs, #1/4-20 studs on 5/8 in. centers, for 4 AWG or larger. Max. lug width is 0.5 in. (12.7 mm) Chassis ground Two #10 screws on 5/8 in. centers for either a single- or dual-hole lug. Environment: Temp (ambient)* Humidity Specifications: 23 C to 131 F (-5 to 55 C) 0% to 90%, non-condensing * This unit is cooled by natural convection. Do not block air vents at top of panel. Electrical Interface: Operating voltage (nominal) Maximum voltage rating Maximum output current capacity (continuous operation) Maximum input interruption device rating Interrupt Rating (IR) Short Circuit Rating (SC) Disconnect setting Re-engage (pull-in) setting Specifications: -48 Vdc -60 Vdc 80A @ 35 C 70A @ 55 C 100A 100A 5000A Factory set at -39.0 V (±.5 V). LVD STATUS LED turns red when the contactor opens. Factory set at -47.0 V (±.5 V). LVD STATUS LED turns green when the contactor closes. Page 4

Electrical Interface: Contactor Specifications: Dual-pole single-throw LVD Control Card Reliability MTBF > 400,000 hrs. per Bellcore Telcordia Technologies SR 332 Issue 1, May 2001. 1.3 Installation! ALERT ALERT! Only qualified personnel may install and maintain this product. Verify that all connections meet requirements specified in local electric codes or operating company guidelines before supplying power. Protect this equipment with a fuse or breaker sufficient to interrupt power levels specified in Section 1.2 Specifications on page 4. For installation in a data center, incorporate a readily accessible disconnect device into the building wiring. Install this product in locations accessible only by qualified personnel. 1.3.1 Important Installation Considerations Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips). Disconnect Device - A readily disconnect device shall be incorporated in the building installation wiring. Over-Current Circuit Protection - Any DC power source, of any nature, feeding the LVD must be properly circuit protected per NEC standards. Telect recommends this power source be protected with an external breaker rated at 60 Vdc, 125 Amperes maximum. Page 5

Intended Location - This unit is intended only for installation in a restricted access location. NOTE: This unit receives power from more than one source. 1.3.2 Inspection Please read these instructions carefully before beginning installation. If you need assistance, call Technical Support at 1-888-821-4856 (domestic calls), or 509-921-6161 (Option 2), or email us at getinfo@telect.com. Inspect equipment after unpacking and compare it to the packing list. Immediately report any shipping damage, defects, or missing parts to Telect at 1-800-551-4567. Keep all documentation that comes with your shipment. Telect is not liable for shipping damage. If the product is damaged, notify the carrier and call Telect s Customer Service Department at 1-800-551-4567 (domestic only) or 1-509-926-6000 for further recourse. NOTE: For service or warranty information, please visit the telect.com website, or email inquiries to getinfo@telect.com and click on the Support tab, or phone us at 800-551-4567 (domestic only) or 509-926-6000. 1.3.3 Installation Procedure Each panel is thoroughly tested and calibrated at the factory. No user testing is necessary. 1. Remove the transparent cover on the front of the panel. 2. Locate an unused rack position as close as possible to the output power distribution unit. 3. Secure the brackets to the sides of the panel, as shown in Figure 6. Figure 6 - Panel Brackets Page 6

Panel brackets provide flush or extended EIA or WECO mounting in a 19- or 23-inch rack. The front of the panel can be extended by ½ inch increments up to 3 inches. 4. Mount the panel using the four 12-24 thread-cutting screws, washers, and lockwashers provided. 5. Tighten the screws to 35 in-lb. (4.29 N m). 6. DO NOT CONNECT POWER before properly grounding the panel, as follows:! WARNING WARNING! Failure to properly ground this equipment can create hazardous conditions to installation personnel and to the equipment.! a. Use a listed (approved) crimping tool to attach an approved, single- or dual-hole lug (#10 holes on 5/8 in. center) to a suitable conductor. b. Connect the ground lug using one or both SEMS screws and the washers provided. c. Tighten the 10-32 grounding screw(s) to 25 in-lb. (~2.8 N m), max. d. Connect the opposite end of the ground conductor to a suitable ground bar. WARNING WARNING! Before connecting input power cables, make sure the input power to the panel is turned off. 7. For output wiring, crimp dual-hole compression lugs for 1/4-in. studs on 5/8-in. (15.9 mm) centers onto suitable copper wires (#4 AWG or larger) for Sides 1 and 2. (Lug width must not exceed 0.5 in. [12.7 mm].) 8. Use heat-shrink tubing to cover the ends. 9. Use a coarse, nonmetallic cleaning pad to clean the terminals. 10. Telect recommends lightly coating lugs and LVD output terminals (NEG and POS RTN, nearest the front corners) with antioxidant. 11. Connect the lugs to the terminals on both Sides 1 and 2, using the 1/4-20 hardware provided. Figure 7 - Conductor Installation Page 7

12. Tighten the lugs to ~50 in-lb. (~5.65 N m), max. 13. Connect the output conductors to the output device, such as a secondary power distribution unit. 14. Similarly, for input wiring, prepare and install lugged LVD input conductors on both Sides 1 and 2. 15. Confirm that power is disabled at the power source (battery or power supply), then connect this panel s input cables to the source. 16. Enable the battery or power supply source bus to provide power to the LVD panel. 17. Ensure correct voltage and polarity at all terminals. Figure 8 - Conductor Installation 1.4 Compression Lugs The panel s four, -48 Vdc input and output studs require dual-hole compression lugs suitable for 1/4-in. studs on 5/8-in. centers. The ground terminal requires a single- or dual-hole lug suitable for #10 screws on 5/8-in. centers. The following tables show the suggested lugs. Table 1 - Input & Output Power Lugs (1/4-in. Dual Holes on 5/8-in. Centers) 4 AWG 2 AWG Straight Tongue 45 Tongue Straight Tongue 45 Tongue Burndy YA4C-2L (Burndy Die 8 YA4C-2L-45 (Burndy Die 8) YA2CL2NT14 (Burndy Die 10) YA2CL2NT1445 (Burndy Die 10) Panduit LCDN2-14A-Q (Panduit Die 33) (Burndy Die 10) LCDN2-14AH-Q (Panduit Die 33) (Burndy Die 10) Table 2 - Ground Lugs (#10 Dual Holes on 5/8-in. Centers) 8 AWG 6 AWG (Preferred Burndy Panduit YA8CL2TC10 (Burndy Die Code 49) LCD8-10A-L (Panduit Die Code 21) (Burndy Die Code 49) YA6CL2TC10 (Burndy Die Code 7) LCD6-10A-L (Panduit Die Code 24) (Burndy Die Code 7) 1.5 Maintenance This panel does not require any preventative maintenance. NEVER use this panel to support any weight except its own. Page 8

1.6 Certifications UL listed; NEBS Level III pending. 1.7 Dimensions Page 9

This page intentionally left blank. Page 10