SIGUARD Safety Systems Safety Integrated

Similar documents
Safety Systems Safety Integrated

SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Mechanical Safety

Safety Systems Safety Integrated

52 x 72 x 30 (2.05 x 2.83 x 1.18) N/C + N/O; N/C + N/C N/C + N/O N/C + N/O; N/C + N/C

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Safety switches for hinged doors

Datasheet - ZR Z

SAFETY SWITCHES. Phone: Fax: Web: S20 Safety Switch

Micro Contactor MA Series

Position switches FD series

Position switches FD series

Datasheet - ZS Z

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

OsiSwitch Limit Switches Innovation through modularity

Datasheet - ZR Z

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

XCKP2110G11 limit switch XCKP - metal end plunger - 1NC+1NO - snap - Pg11

Safety switches with separate actuator

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

SMS 3xxx/SMS 4xxx Safety switch with separate actuator

Position Switches Series 8070

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

Limit switches 3. with solenoid interlocking. Metal, type XCSE and XCSL. Page 6/284. Page 6/296

Safety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2

XCKP2110N12 limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT

More than safety. Precision Multiple Limit Switches

Datasheet - SLB 200-C04-1R

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

Safety Switches with Separate Actuator, Metal Housing

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

GENERAL TECHNICAL DATA Specifications, Directives and Standards

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

Switch Disconnectors, Main and EMERGENCY-STOP Switches

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

QUINT-PS/ 1AC/24DC/ 5

Datasheet - AZ 16-03ZVRK

QUINT-PS AC/24DC/10

Safety switches with manual mechanical delay and separate actuator

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

Datasheet - SRB 301LC/B-24V

Thermal-Magnetic Circuit Breaker 4220-T...

Safety switches with separate actuator

XACA2074 pendant station XAC-A pistol grip - 2 push buttons 1 Emergency stop

Microswitches MS Series

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

ASI QUINT /2.4 EFD

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

Product and functional description

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

Devices raised mounting

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Protection Equipment

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Machine Safety. Products

PSR UC/ESAM4/3X1/1X2/B

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Contact protection relay

Limit Switches and Safety

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

Datasheet - AZ 16-02ZVRK-ST

SAFETY LOCKING DEVICES

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

Datasheet - AZ 15 ZVRK

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications

Datasheet - AZ 16-02ZVK

Product and functional description

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications

ZB5FG09 flush mounted selector switch head key pos stay put

Safety switches with separate actuator

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

Electronic timer CT-ARS.11

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Datasheet SRB301ST 24V (V.2)

Power Supply HARTING pcon

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

Datasheet - AZ 15 ZVRK

General-purpose Limit Switch

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

PSR DC/ESP4/2X1/1X2

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.:

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Introduction Circuit Protection

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Safety switches with manual mechanical delay and separate actuator

Limit Switches and Safety

Transcription:

SE 10 / SE. 00 / SE. 4 / SE. 5 Molded plastic / metal enclosure with separate actuator Application Safety interlock switches (limit switches) with separate actuator are used where the position of doors, covers or safety screens must be monitored for safety reasons. For example, they are used together with TK8 safety combination units, up to safety category 4. Approvals The SE 00 molded plastic enclosed safety position switches and the SE 10 metal-enclosed safety position switches have been given approval test certificates in accordance with German regulations (BIA) as well as Swiss regulations (SUVA). The SE 4 and SE 5 molded plastic enclosed safety position switches have been given an approval test certificate in accordance with German regulations (BIA). Construction These compact SIGUARD position switches are available in three versions: With molded plastic enclosure and fixing dimensions acc. to EN 50 04 With metal enclosure and fixing dimensions acc. to EN 50 041 With molded plastic enclosure outside of the standards that has arisen in this form in accordance with general market requirements. Mounting dimensions when using the switch as a safety position switch are as follows: 0mm(molded plastic enclosure) Technical data 0mm (metal enclosure) and the switch must be fitted with a pin or with a stop. Operation The position switch can only be operated with the matching triple-coded actuator. Simple overruling by hand or auxiliary devices is impossible. Mounting is possible in two positions (180 apart), making it possible to have four different operating directions. The actuator with side can be repositioned every 90 ; it cannot be replaced with actuators of the standard type. A single gland entry protects against ingress of dust and water, preventing misoperation of the switch. Radius actuator SIGUARD position switches with radial actuators are particularly suitable for applications where vibration or movement is a problem. Positive opening The switch can be used in safety circuits due to the positive opening of the NC and positive closing of the NO contacts by pulling the actuator. The position switch must not be used as an end stop. Contact reliability The moving contacts are designed as double break contacts (for SE 00-.XX1, as single break contacts). This increases the contact reliability even when the switch has to be operated with low voltages and currents, e. g. DC 5 V/1 ma. The switching point of the snap action contacts is independent of the switching corrosion. Rated insulation voltage U i Short circuit protection 1 ), DIAZED-fuse links Rated operational voltage U e Conventional free air thermal current I th 1) Without any welding acc. to DIN VDE 0660 Part 00. 500 V Utilization category gl/gg 6 A, quick response characteristic: 10 A AC 500 V, over AC 80 V only for equal potential Rated operational current I e AC to 60 Hz DC Mechanical endurance 10 A U e I e /AC-1 I e /AC-15 U e I e / DC-1 I e / DC-1 V A A V A A 4 10 10 4 10 10 15 10 10 48 6 4 0 10 6 110 4 1 0 10 4 0 1 0.4 500 10 4 0.5 0. >1 10 6 operating cycles Electrical endurance >1 10 6 operating cycles with RH11, RT10 16, RT10 1, RT10 4 to RT10 6 (TH4, TF to TF4) contactors for AC-15 duty 0.5 10 6 operating cycles when interrupting I e /AC-15 at 0 V for DC-1 duty Ambient temperature SE. 0 to +85 C SE. 1 5 to +85 C Degree of protection DIN VDE 040 and IEC 60 59 SE. 00 IP 65 SE. 1, SE 4, SE 5 IP 6 Conductor cross-sections SE. 1, SE -solid -finely stranded with end sleeve SE. 5, SE 4, solid or finely-stranded with end sleeve Mounting position With DC the contact endurance depends not only on the breaking current but also on the voltage, the circuit inductance and the speed of switching. No generally valid information can be given. max..5 mm² max. 1.5 mm² 1 (0.5 to 1.5 mm²), (0.5 to 1 mm²) any 9/5

SE 10 / SE 10 Metal enclosure with separate actuator Selection and ordering data or 4 contacts Moving double break contacts 1 ) Actuation/Fixing Enclosure width/ length of actuator SE. position switches SE. position switches SE. position switches Wght. with slow-action contacts with slow-action contacts with 4 slow-action contacts ap. acc. to EN 50 01 6 mm stroke 6 mm stroke 6 mm stroke Ident. No. 0 acc. to EN 50 01 Ident. No. acc. to EN 50 01 Order No. Price Order No. Price Order No. Price mm 1 unit 1 unit 1 unit kg Metal enclosure IP 6, EN 50 041 SE 10- Lateral SE@ 10-0XX SE@ 10-6XX SE@ 10-4XX On req. 0. 0XX Order No. suffix with metric connecting thread M0 1.5 with Pg 1.5 connecting thread with 1/ NPT connecting thread SE10-0XX SE10-6XX SE10-4XX 0. Standard 9 SX 19 0. With transverse fixing 9 SX 06 0. Universal radius actuator 90 SX 0 0.. Operation, operating speed and travel Operation by a separate bar Switch blocks Nominal travel and related terminals v max max. operating speed direction of operation Radius : for all approach directions Internal circuit diagram Terminal designation acc. to EN 50 01 contact closed contact open in actuator head; NC is closed Separate actuator Slow-action contacts perpendicular to plunger axis Side operation SE 10.XX / SE-10.XX v max = 1 m/s Ident. No. 0 Minimum force required in operating direction on retraction 10 N Ident. No. Positive opening acc. to IEC 60 94-5-1, Appendix K, and DIN VDE 0660 Part 00. 9/58 1) Supplied without actuator. ) Radius actuator (universal): R min > 0 mm. Discount Code: SIGUARD Safety ) For conduit thread adaptors see page 9/5.

Selection and ordering data contacts Moving double-break contacts 1 ) Actuation/Fixing Enclosure width Length of actuator SE. position switches SE. position switches Wght. with slow-action contacts with slow-action contacts appr ox. acc. to EN 50 01 SE. 00 6 mm stroke 6 mm stroke Ident. No. 0 acc. to EN 50 01 Order No. Price Order No. Price mm 1 unit 1 unit kg Molded plastic enclosure IP 65, EN 50 04 SE 00- Lateral 1 SE@ 00-0XX0 SE@ 00-6XX0 0.18 0XX0 Front-end 1 SE@ 00-0XX04 SE@ 00-6XX04 0.18 Order No. suffix with metric connecting thread M0 1.5 with Pg 1.5 connecting thread SX 196 Standard actuator 50 SX 196 0.18 0 SX 195 0.18 SE 00-0XX1 5 directions of approach ) 1 SE 00-0XX1 SE 00-6XX1 0.18 SX 0 Standard 44 SX 0 0.1 With transverse fixing 6 SX 1 0.1 Radius actuator 44 SX 54 0.1 For operation, operating speed and travel, see Page 9/61. Positive opening acc. to IEC 60 94-5-1, Appendix K, and DIN VDE 0660 Part 00. 1) Supplied without actuator. ) For conduit thread adaptors see page 9/5. Discount Code: SIGUARD Safety 9/59

SE. 4 / SE. 5 Selection and ordering data contacts Moving double-break contacts 1 ) Actuation/Fixing Enclosure width Length of actuator SE. position switches SE. position switches Wght. with slow-action contacts with 1 slow-action contact appr ox. 6 mm stroke 6 mm stroke Ident. No. 1 Wght. Ident. No. 01 acc. to EN 50 01 appro acc. to EN 50 01 Order No. Price x. Order No. Price mm mm 1 unit kg 1 unit kg Molded plastic enclosure IP 6 SE. 4-0XX Lateral and front-end Extraction force 5 N 5 SE@ 4-0XX 0.14 SE@ 5-6XX 0.10 Extraction force 0 N 5 SE@ 4-0XX 0.14 SE@ 5-6XX 0.10 With automatic ejection 5 SE@ 4-0XX0 0.14 SE@ 5-6XX0 0.10 Order No. suffix with metric connecting thread M 16 with connecting thread Pg 11 Standard actuator (r min. = 150 mm) SX 18 Radius actuator (universal) (r min. = 45 mm) SX 8 Ball catch (up to 100 N) SX 1 Accessories Slit cover (1 set = units) Dust protector and slit cover (1 set) SX SX 4 For operation, operating speed and travel, see Page 9/6. 1) See section 16 for AS-Interface connection. Positive opening acc. to IEC 60 94-5-1, Appendix K, and DIN VDE 0660 Part 00. 1) Supplied without actuator. ) For conduit thread adaptors see page 9/5. 9/60 Discount Code: SIGUARD Safety

Operation, operating speed and travel Operation by a separate bar Switch blocks Nominal travel and related terminals v max max. operating speed direction of operation Radius : for all approach directions Internal circuit diagram Terminal designation acc. to EN 50 01 contact closed contact open in actuator head; NC is closed Separate actuator Slow-action contacts perpendicular to plunger axis for front-end operation SE 00.XX0 SE 00.XX04 Lateral v max = 1.5 m/s Axial and front-end v max = 1 m/s Identification number 11 Ident. No. 0 SE 00 / SE. 4 / SE. 5 Minimum force required in operating direction on retraction 10 N a b Short 4 to 45 66.5 to 69 Long 6 to 65 86.5 to 89 Axial and lateral (4 90 ) SE 00.XX1 Vertical 10... 1,5 14... 16,5 10 N NSC 00a R min. 00 Horizontal R min. 00 Ident. No. 0 R min.00 NSC 0061 1... 1 14... 16,5 R min.50 Lateral and front-end SE 4.XX.., SE 5.XX.. Ident. No. 1 0 N or 5 N Ident. No. 01 1) Radius actuator: R min > 8 mm. 9/61

ø4, 56 ø8, SE. 00 Dimension drawings Molded plastic enclosure SE. 00-.XX0, lateral SE. 00-.XX04, front-end Permissible center offset of actuator to position switch: vertical and horizontal ±1 mm a b Short 4 to 45 66.5 to 69 Long 6 to 65 86.5 to 89 Radius : for all radii 50 mm, lateral and front-end Short actuator SX 196 Long actuator SX 195 SE. 00-.XX1, 5 approach directions 0,5 0,9 41,5 5 99 ø4, 0/ NSC006a 0,5 Radius : for all radii 50 mm, lateral and front-end Standard actuator SX 0 for transverse fixing SX 1 Radius actuator SX 54 4,4 0 1 0 1 9,5 11,5 4,4 4, 4, 1, 44,4 N SC00 0,6 6, NSC009 1 16 0,4 44,4 NSC008 9/6

50 5, 14 SE 10 / SE. 4 / SE. 5 Metal / molded plastic enclosure with separate actuator Dimension drawings Metal enclosure SE. 10-.XX / SE-10-.XX lateral SX 19 for lengthwise fixing SX 06 for transverse fixing Universal radius actuator SX 0,5 5 NSC000 Molded plastic enclosure SE. 4, lateral and front-end, with standard actuator SX 18 56 for M 5 countersunk screw 0,5,8 8,5 6,5 16 SE. 5, lateral and front-end Universal radius actuator SX 8 56 8 16 5 8 9 18 1 4 NSC008 Æ Ball catch SX 1 11 NSC0081 4,8 90 9 8 18 14 8 1 4 5 4 NSC0_0080 a 9 1 0 5 Pg 11 8,5 0,5 0,5 15,8,5 6,5 56 NSC0_008 10 15, for M 5 countersunk screw 9/6