Quick Installation Guide

Similar documents
Quick Installation Guide

Quick Installation Guide

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

Quick Installation Guide

NMEA2000 DC MONITOR Part Numbers: 3410 USER MANUAL

Manual# Installation Manual SDU 404. Shutdown Unit

Quick Installation Guide

Manual# Installation Manual SDU 410. Safety Shutdown Unit

User s Manual. Revision 1.0. Copyright 2016 Maretron, LLP All Rights Reserved

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

WIRED REMOTE INSTALLATION GUIDE

Instruction Manual. ICENI/TB-02 Terminal Block Module (Type 2) Pub_ Issue 1

Operating instructions. Switching amplifier DN0210 DN / / 2015

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

WINSTA. Full Line Catalog 2008/2009

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

TSX SCA 64 connection box

Operating instructions. Speed monitor D / / 2014

AF Upgrade Instructions

Manual# Installation Manual. 400E Series. DCU 410E Engine Control Unit RP 410E Remote Panel

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Pro-Flo System Digital Controller EPROM Upgrade

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Operating instructions IO-Link master CabinetLine AL19xx

INSTALLATION INSTRUCTIONS

Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet

12.3 Pro Dash Quick Start Guide

Blue LED Pulsed Light Source LS-475. Installation and Operation Manual Document Number

Model 2380 Rack-Mount Kit

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

GMT INC. EZGO Radio Console Present Section I Installation Preparation. Part Number: EZ40X-X Section I Installation Preparation Kit Contents

RECTANGULAR LED 3060-L L L-8060

EX-RC1 Remote I/O Adapter

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

Vision OPLC V TR6/V350-J-TR6

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

OPLC Installation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Series 3700 Screw Terminal Assemblies Installation Instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

FLEX Ex Spring Clamp Terminal Base

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

TRC-190 User s Manual

UniStream HMI Panel. CPU-for-Panel

This guide provides basic information for Unitronics controller model V T2.

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

MINI MCR-SL-CVS NC

INSTALL INSTRUCTIONS RSXMR-9886-P-48

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

NBT EVO GPS Receiver

RackInjector Hardware Installation Manual

DC Outdoor Power Supply/Chargers

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

USER MANUAL. RC-54DL KNET Auxiliary Control Panel MODEL: P/N: Rev 2

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Operating instructions Evaluation system for flow sensors VS / / 2013

User Manual HMI Linkbox HL01 DP/MPI

Bluetooth Shielding Instructions

FUSION MS-RA70/MS-RA70N Installation Instructions

Installing a Power over Ethernet injector

hp uninterruptible power system r12000 xr models installation instructions

Power Supply, 17-inch

MINI MCR-SL-PT100-UI-200

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN

Procedure to Upgrade from B&W Maintenance Panel to TIB Color Touchscreen Door in a Working Maxum or Maxum II Analyzer Equipped With a SYSCON2

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Rack Installation Instructions

Vision OPLC. V T38 Installation Guide. General Description

High Speed Remote I/O Module

Installation Note. Agilent PSA Series Spectrum Analyzers Secure Memory Erase, Option 117

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

5504 Thermocouple Analog Input Module

Model 2380 Rack-Mount Kit

MINI MCR-SL-MUX-V8-FLK 16

Content. Product Description

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Replacing the Power Supply

Luxline driver. LL-PCB-LUXlinedriver. Lux Lumen bvba Kernenergiestr. 53a 2610 Wilrijk. Luxline driver - page 1 T F

Transcription:

Manual# 1140131 Quick Installation Guide Gateway NMEA2000/J1939

Quick Installation Guide for Gateway NMEA2000/J1939 ~~~ Printed May 2016 Revision Revised www.auto-maskin.com

Copyright 2013-2016 by Auto-Maskin AS. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of Auto-Maskin AS. Page ii Quick Installation Guide

Table of Content DOCUMENT INFORMATION... 1 ABOUT THIS MANUAL... 1 Responsibilities... 1 INTRODUCTION... 2 FIRMWARE REVISIONS... 2 PRODUCT FEATURES... 2 INSTALLATION OF THE GATEWAY... 3 UNPACKING THE BOX... 3 MOUNTING THE UNIT... 3 CONNECTING THE NMEA2000 CABLE... 3 CONNECTING THE J1939 CANBUS CABLE... 3 J1939 CANbus connections... 4 CONFIGURATION... 5 NMEA INSTANCE... 5 GPS INSTANCE... 5 FRONT PANEL INDICATORS... 6 BLUE LED... 6 GREEN LED... 6 MAINTENANCE... 7 Quick Installation Guide Page iii

Document Information For updated information, please contact your local distributor. About this manual This manual has been published primarily for professionals and qualified personnel. The user of this material is assumed to have basic knowledge in marine systems, and must be able to carry out related electrical work. Work on the low-voltage circuit should only be carried out by qualified and experienced personnel. Installation or work on the shore power equipment must only be carried out by electricians authorized to work with such installations. Responsibilities It is the sole responsibility of the installer to ensure that the installation work is carried out in a satisfactorily manner, that it is operationally in good order, that the approved material and accessories are used and that the installation meet all applicable rules and regulations. Note! Auto-Maskin continuously upgrades its products and reserves the right to make changes and improvements without prior notice. All information in this manual is based upon information at the time of printing. Quick Installation Guide Page 1

Introduction The Auto-Maskin NMEA2000 to J1939 CANbus Gateway is designed to convert Latitude, Longitude, Compass Direction and Vehicle Speed messages on the NMEA2000 network onto the J1939 network. This unit is designed to operate in a protected marine environment such as an engine room. It is very important that it is installed and set up correctly according to this manual. Please read the entire manual before starting the installation, and follow the setup instructions carefully to achieve the best results. User settable NMEA GPS Device Instance using rotary switch Blue LED confirming NMEA GPS data reception NMEA2000 interface optically isolated from the J1939 CANbus Power drawn only from the NMEA2000 interface Panel or DIN-rail mounting option Firmware Revisions The information in this manual corresponds to the gateways firmware revision 1.0.0. Note! The Auto-Maskin Marine Pro engine panels require firmware 2.11 and above to support this gateway. Product Features Connection to J1939 CANbus network using a 3-pole Wago cage clamp connector Green LED confirming valid J1939 CANbus message transmission NMEA2000 micro C interface plug User settable NMEA Device Instance using rotary switch Page 2 Quick Installation Guide

Installation of the Gateway This chapter covers installation of the Gateway. Unpacking the box The box shall contain the following material: 1x p/n 1121416 Gateway 1x DIN-rail mounting kit, with two rail mounts and four countersunk M3 screws for rails This manual Mounting the unit The unit can either be mounted to a flat surface using four mounting screws, or to a DIN-rail using the DINrail mounting kit that comes in the box. The unit dimensions and mounting hole locations are shown on the following drawing. Connecting the NMEA2000 cable The unit shall be connected to the NMEA2000 network by the 5-way micro C socket on the front. Carefully attach the network dropcable to this plug and hand-tighten until it is fully seated. Take care to match the orientation of the pip inside the socket to the recess inside the drop-cable plug. The other end of the drop-cable shall be connected to a suitable T- connector on the NMEA2000 network backbone cable. Note! The NMEA2000 bus shall be a 12V, and not a 24V, powered bus! Connecting the J1939 CANbus cable The cables connecting the device to the J1939 CANbus network shall be connected to the Wago Cage Clamp terminal block. Quick Installation Guide Page 3

The wire shall be stripped 8 mm and then the cage clamp shall be opened with a small screwdriver in the slot above the wire connection. Then, simply insert the wire into its connection slot and release the cage clamp by removing the small screwdriver. This will produce a secure gas-tight connection on wire sizes ranging from 0.08-1.5 mm 2. J1939 CANbus connections The terminal connections are numbered as follows: Terminal Signal 1 CAN H 2 Ground 3 CAN L These are labeled on the unit case. Page 4 Quick Installation Guide

Configuration The following two items can be configured directly on the Gateway using the two small rotary switches. There are no other menu setups to worry about. Valid GPS Instances range from 0 through to F. If the Gateway does not receive any data from a GPS device with the selected GPS Device Instance for more than 30 seconds, then it will automatically start transferring all valid GPS data and ignoring the GPS Device Instance. NMEA Instance Each Gateway connected to the NMEA2000 network needs to have a small unique Device NMEA Instance Address. If two or more units are connected on the same NMEA2000 network, then make sure each Gateways NMEA Instance is unique, eg. 0 and 1. The NMEA Instance of each unit is set by turning the small rotary switch with a small screwdriver. Valid Device NMEA Instances range from 0 through to F. GPS Instance The Gateway connects to the NMEA2000 network and translates messages into the J1939 CANbus network. To ensure that only the data from one GPS device on the NMEA2000 network is forwarded to the J1939 CANbus network, the GPS Instance switch has to be set to the same Instance as the Device Instance of the GPS device. Quick Installation Guide Page 5

Front Panel Indicators Blue LED The left-hand side blue LED flashes on NMEA2000 transmits, and every 2.5 seconds while receiving valid GPS data. Green LED The right-hand side green LED flashes only on transmission of J1939 CANbus messages, which is every second. Page 6 Quick Installation Guide

Maintenance Clean the unit with a soft cloth. Do not use chemicals cleaners as they may remove paint or markings, or may corrode the enclosure or seals. Ensure that the unit is mounted securely and cannot be moved relative to the mounting surface. If the unit is loose, tighten the mounting screws. Check the security of the cables connected to the NMEA2000 connector and the J1939 CANbus connector, and tighten as necessary. Quick Installation Guide Page 7