Network expansion. Economic approach to distribution of synchronisation references to network elements. Introduction

Similar documents
Application Note. Re-timing: Cost-effective Synchronization via Re-timed E1 and DS1 Signals. Precision, Stability, Innovation, Support.

OSA 5548C BITS/TSG Timing Signal Generator

White paper Application note

Synchronisation Supply Unit for PDH & SDH networks

GILLAM-FEi US4G. Synchronisation Supply Unit Network Clock Distributor. for PDH & SDH networks PRODUCT SPECIFICATIONS

The TimeHub 5500 System

Traditional Synchronization Standards Overview

DTS 4160.grandmaster. Swiss Time Systems. High precision time server, grandmaster and PRC

Mandozzi Elettronica Inc.

Modular Master Clock!

RME-V01. Digital Instruments. Time and Reference Measurement System

The Cardax FT Controller 6000 can support up to 16 GBUS devices.

G.823 and G.824. Silvana Rodrigues Phone:

Loop-O 9300 Fiber Optical Mux

Reference Access and Interconnection Offer

Loop-O9330 Fiber Optical Mux

Backbone network technologies. T Jouni Karvo, Timo Kiravuo

4 balanced inputs 1 relay output

Connection Master. Mission critical multiservice access platform for utility, corporate and enterprise customers

DRS/FI. Digital Radio System/Full Indoor (Hybrid) Frequency Range from 4 to 11GHz HIGH CAPACITY MW SYSTEMS. System Features

Packet-Based Primary Reference Source for Synchronizing Next Generation Networks

Kyland Technology Co., Ltd. White Paper KT/ZY-RD Kyland Technology Co., Ltd. White Paper. High Precision Time Synchronization

Synchronization Networks Based on Synchronous Ethernet

WECC Guideline Digital Circuits Synchronization

Final draft ETSI EN V1.2.1 ( )

Main Options. Synchronisation source: Satellite (GPS) Terrestrial Low Frequency (MSF, DCF77, WWVB, etc) Timecode (IRIG, AFNOR, etc)

DTS 4210.timecenter. High precision time server, grandmaster and PRC

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

Product Specification SDH Monitor 3.0

KHUSHI COMMUNICATIONS

LTC 8900 Series Allegiant Video Switcher/Control Systems

A0750 AC-DC POWER MODULE

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

LOOP-O 9100 STM1 ADM/TM

Advanced Test Equipment Rentals ATEC (2832) PSURGE Haefely is a subsidiary of Hubbell Incorporated.

LANTIME M3000: Time and Frequency Synchronization Platform

Gmux Modular TDMoIP Gateway FEATURES

ROCON RPC 116. SUBSTATION AUTOMATION Central unit for substation automation

ITU-T Q13/15activity and its relation with the leap second. Jean-Loup Ferrant, ITU-T Q13/15 Rapporteur Calnex solutions

Status of ITU Q13/15 sync standards ITSF Jean-Loup Ferrant, ITU-T Q13/15 rapporteur

DM16E1 Series II DM4E1 Series II

MODULAR DC POWER SUPPLY MODEL 62000B SERIES MODEL 62000B SERIES. Modular DC Power Supply. Ethernet. Key Features :

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Digital networks Design objectives for digital networks

Connection Master. Mission critical multiservice access platform for utility, corporate and enterprise customers

D9408 Advanced ATM Adapter

WT-380 Automated Switching Solution For 48 Twisted Pairs or 40 Twisted Quad Cables

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Customer Interface Publication: KCH CIP009. Technical Characteristics of the kbit/s (155Mbit/s) digital leased line

LRS-12. "Last Mile" SNMP Modem Rack FEATURES

4 Channel Video Receive Unit for a Singlemode Fibre Link

Options for Mitigating Potential GPS Vulnerabilities

V C ALIANT OMMUNICATIONS. STM-1 Optical to STM-1 Electrical Converter. Data Sheet & Product Brochure U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

Master Time Center. Control Center for Multifunctional Time Distribution Systems and Mains Frequency Supervision

Product Specification E1/T1 Monitor 3.0

FE1&10/100BASE-T Bridge

MLC 9000 Bus Compatible PID

We are securing the past in a fast moving future. FOX605 multiservice platform.

Protocol/interface converter series

TimeSource Enhanced PRTC Enhanced Primary Reference Time Clock

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

AWG2300. USB Multifunction Arbitrary Waveform Generator SCICORE INSTRUMENTS, INC.

DigiView DV3500 Logic Analyzer

Synchronous Ethernet A RAD White Paper

DESCRIPTION. Features

VCL-TP, Teleprotection Equipment with Trip Counter Display

Reliability, Availability, and Serviceability (RAS)

REGULATED DC POWER SUPPLIES.

Backbone network technologies. T Jouni Karvo, Timo Kiravuo

This specification this document to get an official version of this User Network Interface Specification

Telecom Point to Point Radio

Synchronization Network Migration with focus on coherent network Primary Reference Time Clocks (cnprtc)

UPS Emergency Bed Power Unit

ITU-T G.8262/Y.1362 (08/2007) Timing characteristics of synchronous Ethernet equipment slave clock (EEC)

Gmux-2000 Hub-Site Pseudowire and Voice Trunking Gateway

FMP VDC RECTIFIER 42 Amps 2000 Watts

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Redundancy Concepts. INTRON-D plus. Single System with N+1 Components Duplicated Control System (hot stand-by operation) A+B System (shared operation)

Suppliers' Information Note. BT International MegaStream (2Mbit/s) Service Description

Loop-V4150 DS0 Cross Connect System

Portable Ground Control Station Sentinels portable Ground Control Station (GCS) is designed for controlling unmanned vehicles

16 x E1 G x Ethernet optical multiplexer

VCL-TP, Teleprotection Equipment

5U CWDM Managed Platform SML-5000

OSA 5410 Series. PTP grandmaster, GNSS receiver and sync probe. Your benefits

Improving Mobile Backhaul Network Reliability with Carrier-Class IEEE 1588 (PTP) WHITE PAPER

Synchronization of the Circuit switched network

The Ultimate in Matrix Switching and Control

PSC-AC. PSC AC-series W 1 to 3 Outputs. AC-DC Power supply. Input Voltage ranges. Single output ratings. 2-3 outputs ratings

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

RAIL SIGNALLING SOLUTIONS

8 Channel Video Transmit Unit with 1 Bi-directional Data Channel for a Singlemode Fibre Link

in Berlin (Germany) Sponsored by Motorola Semiconductor NEC Electronics (Europe) Siemens Semiconductors Organized by

Synchronisation Requirements for Wireline and Wireless Convergence. Ghani Abbas ITSF 2006 Prague Nov.,2006

ANT-20SE Advanced Network Tester PDH MUX/DEMUX

The AMG5616A6R is designed to plug into an AMG2005 or AMG2009 subrack, which in turn fits into a 19" rack system.

TECHNICAL SPECIFICATION

CTI CALL INFORMATION INTERFACE

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

Transcription:

Network expansion Economic approach to distribution of synchronisation references to network elements. Introduction The explosion in demand for telecommunications services has resulted in the implementation of complex networks.these often contain a large number of network elements, all of which must be synchronised to ensure that the quality of service meets the international standards and the demands of network users. Very often, extra output capacity is required at the network nodes to synchronise all its elements and it is thus necessary to implement expansion equipment. To meet this requirement, Oscilloquartz has introduced two synchronisation distribution units (SDU), models OSA 5533C and OSA 5530B SDU.

Economic approach OSA 5533C SDU The Synchronisation Distribution Unit OSA 5533C SDU provides up to 48 outputs from one or two inputs. It is ideally suited to stand-alone clock distribution requirements in SDH or SONET nodes where a stable reference is available.the unit provides an economic approach to distribution of synchronisation references to network elements, such as switches, cross-connects and multiplexers. The OSA 5533C SDU can also extend the output capacity of Oscilloquartz synchronisation systems such as OSA 5548B SASE or OSA 5542B CTO. The equipment is available with single or dual inputs at 2.048MHz, optionally 2.048 Mbit/s, 1.544Mbit/s, 1, 1.544, 5 or 10 MHz. Should the selected input fail, the unit automatically switches to the secondary synchronisation input. A highly functional Holdover Unit (HOU) ensures that the OSA 5533C SDU continues to deliver output references even when all inputs are lost. The Holdover Unit contains an oven controlled crystal oscillator whose stability is typically better than 5 x 10-10 /day, which exceeds the requirements of ITU-T G.812 Type III SSU. The HOU also ensures that input switchover is hitless and maintains output phase changes to within the limits specified in G.812, Paragraph 11.1 (25ns for 0.001<T<0.003s). The OSA 5533C provides up to 48 synchronisation outputs that are referenced to the selected input or the Holdover Unit. Output protection is available for up to 32 of the outputs. A 64 output version is also available using 1.0/2.3 connectors. Re-timing is also available for up to 24 channels. The equipment communicates with a local terminal or a PC loaded with the Oscilloquartz local management software for alarm reporting and control. Remote management by SyncView, Oscilloquartz's professional Network Management System, will be available as a future upgrade option. Summary of Features Single or dual inputs 16, 32 or 48 outputs SSM on Mbit/s inputs and outputs Wide choice of output interfaces Holdover typically < 5 x 10-10 /day, exceeds ITU-T G.812 Type III SSU Noise generation to ITU-T G.812 Type I SSU (with ideal reference) Re-timing of up to 24 channels SyncView network management Totally maintenance-free

Extended capacity OSA 5530B SDU The Synchronisation Distribution Unit OSA 5530B SDU is designed primarily to extend the output capacity of our synchronisation systems such as OSA 6500B PRC, OSA 5548B SASE or OSA 5542B CTO. It can also be used in stand-alone applications where a stable reference is available.the unit provides distribution of synchronisation references to network elements, e.g. switches, cross-connects and multiplexers. The OSA 5530B SDU's protected front-end accepts two external synchronisation reference inputs at 2.048 MHz and provides up to 96 1+1 protected or unprotected synchronisation outputs, which are referenced to the selected synchronisation input. Should the selected input fail, the unit will automatically switch to the secondary synchronisation input. Output phase coherence after changeover operations is maintained well below 1/8UI (61ns), typically 5ns.This is important for SDH/SONET networks that are more sensitive to phase variations. Switchover is normally made automatically. Manual switching is done via RS232. The OSA 5530B also includes redundant output ports to drive further SDUs. The equipment communicates with a local terminal or a Personal Computer (PC) for alarm reporting and equipment control. When used in conjunction with an OSA 5548B, the unit can be managed by the SyncView synchronisation network management system for alarm reporting and control functions. Summary of Features Two inputs Up to 96 1+1 protected or unprotected outputs Wide choice of output interfaces Modular approach ETSI or 19" rack mount versions SyncView network management Totally maintenance-free

Two choices Specification OSA 5533C OSA 5530B No. of inputs 1 or 2 2 Type of inputs 2.048MHz or 2.048Mbit/s 1.544, 5 and 10MHz also available 2.048MHz Switchover Automatic Automatic Phase after input changeover 25ns for 0.001<T<0.003s <61ns, typically 5ns Number of outputs Up to 48 (or 64 with 1.0/2.3 connectors) Up to 96 Type of outputs 2.048MHz, 2.048Mbit/s, 1.544Mbit/s, 64kbit/s CC, 1.544, 5 or 10MHz 2.048MHz, 2.048Mbit/s, 1.544Mbit/s, 64kbit/s CC, 1.544, 5 or 10MHz Output card protection 32 outputs can be protected 96 outputs can be protected Holdover capability Exceeds ITU-T G.812 Type III SSU No Re-timing function Local alarms display Relay contacts Local RS232 port SyncView management Please refer to factory for availability Via OSA 5548B SSM support When used with OSA 5548B SASE or OSA 6500B PRC ETSI subrack 6U: 266 x 535 x 265 mm 9U: 399 x 535 x 265 mm 19" subrack Please refer to factory for availability 6U: 266 x 483 x 265 mm Table illustrating some of the main differences between the two models.

Common features Well-proven design The OSA 5533C and OSA 5530B SDUs use the well proven modular approach from Oscilloquartz and are totally maintenance-free. Partially equipped configurations are also available with upgrade capability to the full configuration.all plug-in cards can be replaced in a hot condition. Output Flexibility Various output interface modules are available each with 16 outputs.interface types include 2.048 Mbit/s, 2.048 MHz,1.544 Mbit/s,64 kbit/s CC,1,5,10 MHz and many more. The units offer a highly versatile choice of output connectors that can be configured in groups of four at the factory or in the field. The choice of connectors includes D type for 100,120 or 133 Ohm ports and BNC,1.6/5.6,1.0/2.3 or type 43 for 75 Ohm ports. Several hundreds of outputs can be achieved by adding more OSA 5530B expansion subracks. Alarms and Monitoring Both models include a Monitoring and Alarms Controller (MAC2) card.the card concentrates all shelf alarms,provides visual indicators,relay contacts for in-station monitoring and a local RS232 port.it also features Urgent and Non- Urgent indications as well as a Receiving Attention function to acknowledge active alarms and an audible alarm.with OSA's easy-touse local management software,the user can configure the system,receive spontaneous events and view the alarm list. Output Interface 1 Input 1 Input Interface 1 Holdover Unit Output Interface 2 + + Splitter Input 2 Input Interface 2 By-pass Switch Output Interface 3 Power Supply 1 Power Supply 2 Output Interface 4 Management Module (MAC2-R or RMU) Schematic of OSA 5533C illustrating functional blocks To Local or Remote Management System

Upgrade options Choice of Subracks The 5530B subrack is available in ETSI or 19" rack mount formats.the 5533C is housed in an ETSI,6U high subrack.both models are equipped with redundant power supply modules.these can be DC,AC or a combination of the two. As with all our solutions,the units have been certified to European EMC and Safety standards and thus carry the CE mark. Upgrade Options In accordance with the company's policy with regard to continuous improvement of its solutions,oscilloquartz plans to introduce new features for both models to provide added functionality. Upgrades will include: Re-timing Unit (RTU) to re-time up to eight 2.048 Mbit/s channels Remote Management Unit to enable management by SyncView,Oscilloquartz s professional Network Management System Please contact factory for release dates of these and other upgrade options. We have a very detailed Product Booklet for both the 5533C & 5530B. Call your local representative to obtain your free copy. 2.048MHz Input 1 2.048MHz Input 2 Phase Stepper Switch Channel 1 Phase Stepper Switch Channel 2 Passive Combiner Splitters OIU 1 OIU 2 OIU 11 OIU 12 Outputs to SDU 16 Protected Sync Outputs 16 Protected Sync Outputs Monitoring & Alarms Controller Alarm & Control Power 1 Power Supply Unit 1 Power Feed to Units SSM Interface Unit 1 SSM 1 SSM In 1 SSM Out 1 Power 2 Power Supply Unit 2 SSM Interface Unit 1 SSM 1 SSM In 2 SSM Out 2 Schematic of OSA 5530B illustrating functional blocks

Oscilloquartz SA CH-2002 Neuchâtel 2 Switzerland Telephone: +41 32 722 5555 Facsimile: +41 32 722 5556 email: osa@oscilloquartz.com www.oscilloquartz.com Ed 02/15/9/99 FECH