N EW. Data Logger. 2 GB Internal Memory. ZR-RX Series 32. Easy data recording with all the capacity you need. Best-In-Class.

Similar documents
Portable Multi-lo ZR-RX4 0/ ZR-RX2 0 O P E N. Dear My Buddy,

Portable Multi-logger ZR-RX40 / ZR-RX20 O P E N

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

2D Code Reader V400-F

Switch Mode Power Supplies S8VK-X. IoT Production Site Innovation

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

midi LOGGER GL840 Quick Start Guide GL840-UM-850

DATA LOGGER Series SELECTION GUIDE

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

E5_C-T Programmable Temperature Controller (Digital Controller)

midi LOGGER GL240 Quick Start Guide GL240-UM-852

DATA LOGGER Series SELECTION GUIDE

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151

DIN Track Mounted, Standard 22.5-mm Width Timer Range

Setting New Heights in Data Recording

Switch Mode Power Supplies S8VK-X. IoT Production Site Innovation

8420/8421/ MEMORY HiLOGGER

Durable Space-saving Advanced

Radically Increase the Performance of Multipoint Temperature Control with the EJ1.

Indicator (Square) Ultra Bright LED Type

midi LOGGER GL240 Quick Start Guide GL240-UM-850

Saving a location and and restarting it it on on the the CX-Programmer. Existing the CX-Designer and restarting. Editing a screen on the CX-Designer

Programmable Multi Axis Controller CK3M

MEMORY HiLOGGER LR Featuring USB flash drive support and improved accuracy

NJ/NX-series Machine Automation Controller Database Connection CPU Unit

Practical and Compact!

Indicator (Square) Ultra Bright LED Type

Saved Data playback Saved data in Memory card can be easily called out and played back on display

midi LOGGER HV GL2000 Quick Start Guide GL2000-UM-851

OMRON TM COLLABORATIVE ROBOT

Compact data logger offering best-in-class noise resistance and communication function

, , MEMORY HiLOGGER

CX-Process Monitor Plus Ver. 2.0

6220 Ethernet-Based Voltage Measurement Module

GL500A Application Manual

E5_N/E5_N-H Digital Temperature Controllers

3D Vision Sensor FZD Series

XL112, XL114 ポータブルデータロガ

Your Personal 10-channel Logger. MEMORY HiLOGGER LR8431. Featuring USB flash drive support and improved accuracy

Data Platform GL7000

DC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling

Datum-Y Portable Data Station (XL100)

Long Term Record Data Saving. Saved Data playback. Math and totalization. Communication Ethernet (10Base-T) is available. (option) Screen saver

Paperless Recorder VGR-B100. Series

Digital Temperature Controllers E5 C Series

Programmable Relay ZEN V2 Units

PR Series Paperless Recorders

DISCONTINUED MODEL Replaced with Model MSRPAC-2005

Measure Sounds Reliably

After unpacking, confirm that there are no problems (scratches and dirt) on the exterior before use.

midi LOGGER GL840 Product Introduction (vol. 1, rev. 2) Overseas Sales and Marketing Division

EE-SX95. Meeting Customer Needs with Ultracompact Sensors that Mount with M3 Screws. Ultra-compact Pre-wired Photomicrosensor (Non-modulated) Features

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

Expanding the Basic GL7000 Configuration

Industrial PC for real-time rapid prototyping KEY FEATURES

DISCONTINUED MODEL Replaced with Model MSRPAC-2006

Viper 650/850 eplc. Quick Setup Guide I600-E-01

THE CP1 FAMILY. Compact machine controllers.» Flexible Ethernet connectivity» Easy positioning functionality

ARF200. Paperless Recorder Advanced Recorder

Max. I/O units. consumption

E5CC/E5EC TEMPERATURE CONTROLLER

Specification for temperature sensor calibration setup

DPS SERIES DC POWER SUPPLIES

NX1 Machine Automation Controller Continue to pursue productivity

CPU Units with 20 I/O points

Solid-state timer Compact, Multi-function Timers for G2R Relay Socket. Model Number Structure. Ordering Information. Model Number Legend

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

6220 Ethernet-Based Voltage Measurement Module

SX 6000 Paperless Recorder

CPM1A MICRO PROGRAMMABLE CONTROLLERS

Cobra 350 eplc Robot. Quick Setup Guide I592-E-01

Solder terminals D2FD-2L0-1H D2FD-01L0-1H. PCB terminals D2FD-2L0-1T D2FD-01L0-1T. Hinge lever Solder terminals D2FD-2L1-1H D2FD-01L1-1H

DIGITAL INDICATING CONTROLLER

Measuring and Monitoring Relays K8DT

CJ1W-PTS/PDC/PH41U/AD04U

E2CY-SD. Proximity Sensor with Separate Amplifier Unit for Detection of Non-ferrous Metals with Simple Sensitivity Adjustment

Introducing Hex-shaped Models with Build-in Lenses

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

USER S MANUAL. Data Logger SOUND LEVEL METER.

E5_C TEMPERATURE CONTROLLER

EDX-10 Series Compact Recording System

Web-enabled DAQ System

Wireless Data Logger System

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

ARF100 Paperless Recorder

AUDIN - 8, avenue de la malle Saint Brice Courcelles - Tel : Fax : Web : http:

Sysmac Library Omron's control expertise changes programming

TDS-630. High Performance Easy Handling

Keysight U2751A USB Modular Switch Matrix

Temperature/Process Meter

MEASURING AND MONITORING RELAYS

Attach up to 10 input/output modules in a mixed condition environment. Corresponds to various measurement types (physical, mechanical, and electrical)

Temperature Controllers E5CSL/E5CWL

DIN Track Terminal Blocks XW5T

LE ELECTRONICS Pvt. Ltd.

Transcription:

External Dimensions (Unit: mm) ZR-RX70 N EW ZR-RX45 Data Logger 3 ZR-RX Series 3 0 4.6 3.5 48 3 75 5 ZR-RX70 Mounting Screw Holes -M4 Depth 6 ZR-RX45 Mounting Screw Holes -M4 Depth 6 Easy data recording with all the capacity you need. Internal Memory 69 85 Best-In-Class 3.5 ZR-RX5 9.6 6 6. 67 0 5 6.5 -M4 L5 Insert Screw 40 94 This document provides information mainly for selecting suitable models. Please read the document User's Manual carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. Microsoft, Windows, and Windows 7 are registered trademarks of Microsoft Corporation in the United States and/or other countries. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit Carl-Benz-Str. 4, D-754 Nufringen, Germany Tel: (49) 703-8-0/Fax: (49) 703-8-99 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 6073-530 U.S.A. Tel: () 847-843-7900/Fax: () 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby ), Alexandra Technopark, Singapore 9967 Tel: (65) 6835-30/Fax: (65) 6835-7 OMRON (CHINA) CO., LTD. Room, Bank of China Tower, 00 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 000, China Tel: (86) -5037-/Fax: (86) -5037-00 OMRON Corporation 00-0 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM 0 Printed in Japan Cat. No. E40-E-03 07 (03) (TA) All Multi-input Budget prices

Anyone-Anytime-Anyplace Improved performance and operability for multiple recording needs From the manufacturing floor to the research facility, meeting every need at prices so affordable that every employee can have one. Flash Memory Long-Term Data Capture Best-In-Class Flash Memory Makes long-term capture possible even in workplaces where a cannot be brought in for security reasons. High Data Reliability All Channels Isolated Each channel is supplied with its own circuit eliminating inter-channel noise interference. Versatile Expandability Multi Function Input Simultaneous measurement of temperature, humidity, voltage and other factors can be performed. Ring Memory Capture This function overwrites captured data so that only recent data is saved at all times. Delta-Sigma A/D Converter A new delta-sigma A/D conversion system boosts anti-noise performance. Expandability Expandable up to 00 (ZR-RX45) Calibration services (changed option) Based on our traceability system, we calibrate using gauges that conform to international standards. See our website for additional details. For more information on calibration services, please consult your OMRON sales representatives. All Models All Channels Isolated Improvements Multi-function input Wider range of features PC compatibility Compliant Model High-speed, wide-range voltage measurement model High speed Wide range Pulse Logic Maximum Highspeed Memory () (Resistance capacity thermometer) sampling Max. ±500 V 8 CH 0 µs 56 MB Isolation A/D Resolution Ring LCD LAN conversion memory monitor connection system capture All Sequential comparison 6-bit 5.7-inch (QVGA) CEE -E CCC -CHRO PSE internal flash memory 00-channel expandable temperature measurement model GB Flash memory Channel expansion Windows 7 -compatible Max. ±50 V Standard 0 CH, Max. 00 CH 0 ms All Deltasigma 6-bit 5.7-inch (VGA) -E -CHRO internal flash memory Easy-to-use and compact 0-channel model GB Flash memory Windows 7-compatible Max. ±50 V 0 CH 0 ms All Deltasigma 6-bit 4.3-inch (WQVGA) -E -CHRO Blank after the last hyphen Models compatible with power supply and voltage specifications for each country, as well as conforming to Chinese RoHS are also available. For details, please consult your dealer.

High-speed, wide-range voltage measurement model Simultaneous sampling with external devices Data capture can be timed in response to external device. Capture necessary data only. X-Y Recorder Function The analog X-Y recorder function of the product enables users to view correlations between different pieces of data. The product can also be used as a 4-pen recorder. Digital data captured with this function can be used for reports and other post-measurement work. Smart operability with cursor key Useful Trigger and Timer Functions Multi-function input ±0 mv to ±500 V 8 CH Pulse Logic (Rpm/Count /Inst.) (K, J, E, T, R, S, B, N, W) Sensor (optional ZR-XRH required) 4 in addition to the analog 8 (optional ZR-XRL) 56 MB internal memory 6 bit resolution Wider range of features Max. recording time 0 µs 5.7 inch (QVGA) Easy-tonavigate menus All -hour battery External sampling PC compatibility (High speed) 00BASE-TX Web server FTP server NTP client Intuitive operation using a set of cursor keys allows users to view enlarged and reduced images of high-speed waveforms. A 5.7-inch large-screen color LCD (QVGA) enables easy observation of waveforms and measurements even in a dark place. Easy-to-see big screen 5.7 inch color LCD TIME/DIV key for enlarging or reducing the time axis Time axis Enlarge 0 ms/div to min/div Different combinations of the trigger and timer functions They enable users to eliminate superfluous data and capture the data truly necessary for each situation. Timer Setting Timer mode Off, Date/Time, Daily Cycle, Hourly Cycle Start source setting Off, Level Value, External Input, Scheduled Time Stop source setting Off, Level Value, External Input, Scheduled Time Trigger settings Pre-trigger Only when data is stored in internal RAM Repeat capture 0% to 00% On, Off Setting example Timer Setting Trigger settings Measurement of abnormal signals while a certain device is at work Timer mode Start source setting Stop source setting Repeat capture Daily Cycle Start setting: 09 hrs 00 sec Stop setting: 8 hrs 00 sec Level CH (3V rising) Level CH (V falling) On Highest speed and widest input range in its class Easy control with cursor keys Time axis Reduce Start Key On Finishing data capturing in priority to timer setting Start trigger 3 V Stop trigger V 0:00 6:00 :00 8:00 0:00 6:00 :00 8:00 0:00 Timer period Trigger activation points Data capturing Meeting Versatile Requirements PC Compatibility Isolated multi-function input on all Each channel is supplied with its own circuit preventing inter-channel noise interference. Multi-function input enables simultaneous logging of voltage, temperature, humidity (optional), pulse, and logic. A wide variety of inputs can be logged. BNC / screw hybrid input terminal Each analog input terminal features hybrid BNC terminal / screw terminal specifications. Use either one for voltage input connection. Full Array of Features Super-wide Input Range Current : Clamp meter AC power supply Use in combination with logic input and clamp meter for simultaneous measurement for equipment power supply voltage/current of equipment and sequence control of each component. Sequence: Logic : Wide input range from ±0 mv to ±500 V. It allows the measurement of 00 to 40 VAC power supply waveforms. M3 screw terminals for thermocouple connection BNC terminals for voltage input Ultra high-speed sampling Pulse selectable from Rpm, Count, or Inst. mode for each channel High-speed sampling at speeds up to 0 µs is possible. Thus it is suitable for applications such as drop tests and oscillation tests that require high-speed sampling. Data for lengthy applications, such as endurance tests and environmental tests, can be continuously logged to the flash memory (at a sampling interval of ms or over). Potential recording time (with 8 analog ) 0 µs 00 µs 500 µs ms 0 ms 00 ms s Internal RAM Internal flash memory (Example: 5 MB) 0 s min 40 s 8 min 0 s 6 min 40 s h h Please use a without security function. h 40 s h h day 3 h 4 days 9 days days 3 h 46 days 93 days Versatile PC linkup via LAN,, etc. 3 ways to link to a PC are available through a, a connection, or a LAN connection. No initial setup is required. Supports all kinds of data applications. Remote control / Monitoring function You can remote control the logger from the web browser installed in your PC by connecting the logger with an IP address to the PC through a LAN network. Files stored on the unit (or on the ) can be copied to your PC via the web browser as well. PC viewer function Special software allows you to display captured data easily in waveform format. Search, printout, and CSV conversion can also be performed. Simply start up the software and select a file. For multi-channel measurement and advanced waveform display, we recommend special PC software (Wave Inspire RX). (See p. 8) LAN Logger display and buttons are completely replicated on the web browser! Extract data even while logging is in progress With the pre-installed FTP server function, data stored on the logger can be transferred to your PC even while logging is in progress. Logging in progress FTP transfer LAN Automatic clock-time correction Clock-time of the unit is automatically corrected by the NTP client function. Real-time data gathering in a PC The special software enables real-time data saving in a PC. The logger can be connected to a PC via or LAN connection. Captured data can be simultaneously saved on the logger and on a PC, or on the PC only. You can also save and convert logging data directly to Excel format. 3 4

00-Channel Expandable NEW Measurement Logger with Internal Flash Memory Internal Large-Capacity Flash Memory Best-In-Class The unit features a internal flash memory. Long-term data capture is possible without a. With flash memory, data will not be lost even if power is turned off. Of course direct data capture to a is also possible, and data will be stored even if the is replaced while measurement is in progress. Please use a without security function. 0 ms High-Speed Sampling Higher voltage measurement sampling speeds achieved. Data can be captured at intervals as short as 0 ms. Potential recording time (with 0 analog only) Sampling speed Number of operating 0 ms 0 ms 50 ms 5 00 ms 00 ms 500 ms 0 0 50 s 00 s 00 Multi-function input Wider range of features PC compatibility Potential recording time (with 0 analog ) Length of data capture (sampling speed) Internal flash memory GB 0 ms 50 ms 00 ms 00 ms 500 ms s 0 s 9 days 5 days 7 days 38 days 89 days 47 days 0 days 53 days 506 days 54 days 35 days 70 days : Number of that can be added is limited: at 0 ms, channel; at 50 ms, 5 ; at 00 ms, 0. : Please use a without security function. 5,068 days,70 days Type of measurement: Sampling speed for temperature is equivalent to that of voltage, as it is scaled to 0- V. Pulse ±0 mv to ±50 V (Rpm/Count /Inst.) Resistance thermometer Logic Sensor (optional ZR-XRH) (K, J, E, T, R, S, B, N, W) Resistance thermometer (Pt00, JPt00, Pt000) Select 4 of logic input or 4 of pulse input (optional ZR-XRL) Standard 0CH Max. 00 CH internal memory 6 bit resolution Max. recording time 0 ms 5.7 inch (VGA) Easy-tonavigate menus All 7-hour battery insertion or removal during data gathering (High speed) 00BASE-TX Web server FTP server NTP client Easily readable 5.7 inch VGA LCD Comes with bright, easily readable 5.7-inch large-screen color LCD panel with VGA (640 x 480 dot) high resolution. Measured values and waveform can be vividly displayed in addition to set values. Secure Ring Memory Capture This function deletes unneeded past data so that only recent data is saved to the internal memory or at all times. It conveniently allows the data logger to be set up and continually capturing data, and also prevents data capture failure when trouble occurs. (The length of time data is saved can be preset.) Max. 00 Channels, Additional Expandability via PC Connection Meeting Versatile Requirements PC Compatibility Isolated Multi-Function Inputs Each circuit is electrically so that the different do not affect each other. Built-in delta-sigma A/D converter boosts anti-noise performance as well. The temperature input supports thermocouples and resistance thermometer. Furthermore, in addition to temperature, an array of measurements including humidity and voltage can be taken at once. It also supports logic or pulse input, input from external triggers, as well as alarm signals output. Full Array of Features Resistance Thermometer Input The logger is also compatible with resistance thermometer input, allowing measurement with higher accuracy and greater stability than thermocouples. What s more, the logger measures up to Pt000, enabling temperature measurement with precision previously only found in high-cost measurement devices. External input terminal Logic alarm Logic/ pulse input Alarm output Trigger input GND Switches between logic and pulse Analog signal input terminal Max. in its class Expandable up to 00 Each detachable terminal block has a standard 0 per unit. Up to 0 units can be connected making it possible to extend up to as much as 00. It can also be used in car data logging where multi-measurements of temperature, voltage, etc. on many is needed. Maximum 0 unit connection Versatile PC linkup via LAN,, etc. 3 ways to link to a PC are available through a, a connection or a LAN connection. No initial setup is required. Supports all kinds of data applications. Remote control / Monitoring function You can remote control the logger from the web browser installed in your PC by connecting the logger with an IP address to the PC through a LAN network. Files stored on the unit (or on the ) can be copied to your PC via the web browser as well. PC viewer function memory LAN Logger display and buttons are completely replicated on the web browser! Automatic Backup of Captured Data Select either a or FTP server to save captured data. If FTP server is selected, data will automatically be backed up on the server, allowing you to establish an automatic data-gathering system without the need for troublesome programs. Ethernet Automatic backup Automatic clock-time correction CLock-time of the unit is automatically corrected by the NTP client function. Real-time data gathering in a PC FTP server Automatic backup memory device The special software enables real-time data saving in a PC. The logger can be connected to a PC via or LAN connection. Captured data can be simultaneously saved on the logger and on a PC, or on the PC only. Photo shows an Omron platinum temperature resistance thermometer, 5 series. The seismic resistance corresponds to Class -A car parts (JIS standards), which means that it can be used stably even when there are vibrations and jolts during data-gathering. Base unit (Approx. 0.5 m) MAX 00 CH Special software allows you to display captured data easily in waveform format. Search, printout, and CSV conversion can also be performed. Simply start up the software and select a file. For multi-channel measurement and advanced waveform display, we recommend special PC software (Wave Inspire RX). (See p. 8) You can also save and convert logging data directly to Excel format. 5 6

NEW Easy-to-use and Compact 0-Channel Logger with Internal Flash Memory Option Special PC software Multi-function input Wider range of features PC compatibility ±0 mv to ±50 V Pulse Logic (Rpm/Count /Inst.) (K, J, E, T, R, S, B, N, W) Sensor (optional ZR-XRH required) Select 4 of logic input or 4 of pulse input (optional ZR-XRL) 0 CH internal memory 6 bit resolution Max. recording time 0 ms 4.3 inch (WQVGA) insertion or removal during data gathering All 6-hour battery (Full speed) Easy-to-use and Affordable, Yet Capable of 0 ms Sampling Speeds! Major functions Easy-to-use operation plus processing capabilities beyond previous logger software! Wave Inspire RX, a special PC software program, offers intuitive operability and data processing capabilities beyond all previous logger software. Featuring a number of functions not available in standard logging software programs, it allows you to directly grab and drag waveforms and scales with the mouse cursor, as well as to group freely and operate multiple windows. Different categories of data can be compared, and the waveform of each input signal can be observed with ease, making it particularly useful when handling a large number of multi-channel measurements. Free Adjustment Function Quick call-up of the cursor Special search function Screen-save function / CSV-save function Report-printing function Free adjustment function Intuitive Control Display side by side Display superimposed Meeting Versatile Requirements 0 Isolated Channels + Multi-Input Though the unit is light and compact, each channel is supplied with its own circuit giving zero inter-channel noise interference. A delta-sigma A/D converter boosts anti-noise performance as well. With inputs not only for temperature but also voltage, humidity, pulse, and logic, this model is suitable for any field. Full Array of Features 0 ms High-Speed Sampling Higher voltage measurement sampling speeds achieved. Data can be captured at intervals as short as 0 ms. Sampling speed Number of operating Type of measurement: 0 ms 0 ms Sampling speed for temperature is equivalent to that of voltage, as it is scaled to 0- V. Secure Ring Memory Capture This function overwrites unneeded past data so that only recent data is saved to the internal memory or device at all times. It conveniently allows the data logger to be set up and continually capturing data, and also prevents data capture failure when trouble occurs. PC Compatibility Handy PC linkup via connection 50 ms 5 First in its class Fastest in its class 00 ms Internal Large-Capacity Flash Memory The logger is equipped with a for direct data capture. With PC connection, data in the can be displayed in Excel format. Connection to a PC is easy with a, and logger settings can be determined and data transferred in real time using special PC software. PC connection also allows the logger to be used as a. 0 s 0 External input terminal Logic alarm Logic/ pulse input Alarm output Trigger input GND Switches between logic and pulse The unit features a internal flash memory. Long-term data capture is possible without a. With flash memory, data will not be lost even if power is turned off. Of course, direct data capture to a is also possible, and data will be stored even if the is replaced while measurement is in progress. Please use a without security function Potential recording time (with 0 analog ) 0 ms 50 ms 00 ms 00 ms 500 ms s 0 s Internal flash memory GB 38 days 0 days 83 days 44 days 97 days 5 days 94 days 03 days Analog signal input terminal 485 days 97 days 58 days 57 days : Number of that can be added is limited: at 0 ms, channel; at 50 ms, 5. : Please use a without security function. connection Max. in its class 9,74 days 5,78 days Smart search If you connect ZR-RX70 and ZR-RX45 via LAN connection, you can view temperature data measured by ZR-RX45 and voltage data measured by ZR-RX70 simultaneously, and save the data from the different loggers as one file. You can handle data from the two loggers without any data-combining processes. When sampling speed is ms or faster. Drag and drop into the IC Chip group 7 8 Move scale left or right Move waveform up or down Insert comment at an arbitrary position on the waveform Click on waveform, scale, or cursor, and move Easy Comparison and Quick Decision Search all the Search selected in one operation! After the search the have selected status. Viewing Data from Two Data Loggers Simultaneously Change the position of the waveform with a single click of an icon Sophisticated Data Processing Grouping Grouping is simple by dragging and dropping into the created groups. Multiple display Display for each input signal Compare multiple boards (target) For each group a waveform screen can be displayed, so observation of comparisons between groups is possible. Multi-Connection of Different Types of Loggers

Standard Specifications Main Unit ZR-RX70A- ZR-RX45A- ZR-RX5A- Input method All input, Simultaneous sampling of all All input Input terminal shape BNC terminal: For voltage measurement M3 screw type terminal: For voltage/temperature measurement M3 screw type terminal Number of analog input 8 ch Standard: 0 ch Max.: 00 ch (When the terminal unit is connected) 0 ch Sampling speeds 0 µs to min 0 ms (when ch is used) to h 0 ms (when ch is used) to h A/D resolution 6 bit A/D conversion system Sequential comparison Delta-sigma 0, 50, 00, 00, 500 mv,,, 5, 0, 0, 50, 00, 00, 500 V, -5 V F.S. 0, 50, 00, 00, 500 mv,,, 5, 0, 0, 50 V, -5 V F.S. Thermocouple Measurement K, J, E, T, R, S, B, N, W (WRe5-6) temperature Pt00, JPt00, Pt000 (IEC75) Resistance ranges detector 0% to 00% ( 0 to V scaling conversion) 3 External Digital input Logic input (4 ch) or Pulse input (4 ch) 4 5 input/output sections Alarm output 4 ch (Open collector output) Trigger functions Functions Filter functions Calculation function Type PCI/F Function Memory Internal devices External Display Operating environment Vibration resistance Power supply Power consumption Weight External dimensions Accessories : Resistance temperature detector is non-. : BNC terminal and M3 screw type terminal of the same channel cannnot be used simultaneously. 3: A humidity sensor ZR-XRH is necessary. Measurement Accuracy ZR-RX70A- ZR-RX45A- /ZR-RX5A- ±0.5% of F.S. ±0.% of F.S. Measurement Measurement Measurement Measurement Thermocouple temperature range ( C) accuracy temperature range ( C) accuracy R/S 0 TS 00 ±7.0 C 0 TS 00 ±5. C 00 < TS 300 ±5.0 C 00 < TS 300 ±3.0 C R : 300 < TS 600 ±(0.05% of rdg + 3.0 C) R: 300 < TS 600 ±(0.05% of rdg +.0 C) S : 300 < TS 760 ±(0.05% of rdg + 3.0 C) S: 300 < TS 760 ±(0.05% of rdg +.0 C) B 400 TS 600 ±5.5 C 400 TS 600 ±3.5 C 600 < TS 80 ±(0.05% of rdg + 3.0 C) 600 < TS 80 ±(0.05% of rdg +.0 C) K 00 TS 00 ±(0.05% of rdg + 3.0 C) 00 TS 00 ±(0.05% of rdg +.0 C) 00 < TS 370 ±(0.05% of rdg +.0 C) 00 < TS 370 ±(0.05% of rdg +.0 C) E 00 TS 00 ±(0.05% of rdg + 3.0 C) 00 TS 00 ±(0.05% of rdg +.0 C) 00 < TS 00 ±(0.05% of rdg +.0 C) 00 < TS 00 ±(0.05% of rdg +.0 C) T 00 TS 00 ±(0.% of rdg +.5 C) 00 TS 00 ±(0.% of rdg +.5 C) 00 < TS 400 ±(0.% of rdg +.5 C) 00 < TS 400 ±(0.% of rdg + 0.5 C) J 00 TS 00 ±3.7 C 00 TS 00 ±.7 C 00 < TS 00 ±.7 C 00 < TS 00 ±.7 C 00 < TS 00 ±(0.05% of rdg +.0 C) 00 < TS 00 ±(0.05% of rdg +.0 C) N 0 TS 300 ±(0.% of rdg +.0 C) 0 TS 300 ±(0.% of rdg +.0 C) W 0 TS 000 ±(0.% of rdg +.5 C) 0 TS 000 ±(0.% of rdg +.5 C) PC Software Ethernet functions External trigger input ( ch), input signal level, time In combination with timer mode, date and time can be set, and a wide variety of trigger settings such as Every Day Cycle and Every Hour Cycle can be made External trigger input ( ch), Input signal level, time, duration, alarm Off, Line, 5 Hz, 50 Hz, 500 Hz Off,, 5, 0, 0, 40 (moving average) Statistical calculation 6 : Average, peak, maximum, minimum, RMS (maximum of can be set simultaneously) LAN (00BASE-TX),.0 (HIGH SPEED). (FULL SPEED) Realtime data transfer to the PC RAM: 64 MB Flash memory: 56 MB Flash memory: memory 7 5.7-inch color LCD (QVGA: 30 40 dots) 5.7-inch color LCD (VGA: 640 480 dots) 4.3-inch color LCD ( QVGA: 480 7 dots) 0 to 40 C, 5% to 85% (5 to 35 C when operated on batteries) 0 to 45 C, 5% to 85% (0 to 40 C when operated on batteries) Equivalent to automobile parts Type Category A classification AC adaptor; AC00 to 40 V/50 to 60 Hz 8, DC drive: 8.5 V to 4 V, Battery: DC7.4 V ( packs) AC adaptor: AC00 to 40 V/50 to 60 Hz 8, DC drive: 8.5 V to 4 V, Battery: DC7.4 V 4 VA (When the AC adaptor is used) 3 VA (When the AC adaptor is used) 9 VA (When the AC adaptor is used). kg (Excluding batteries and AC adaptor) 900 g (Including one terminal unit, excluding batteries and AC adaptor) 50 g (Excluding battery and AC adaptor) 3 50 80 mm 3 5 50 mm 94 7 4 mm User's Manual, Utility disk (CD-ROM), AC Adaptor/AC 4: A logic alarm ZR-XRL is necessary. 5: Pulse input: Revolutions mode/counts mode/ Inst. mode switch method Measurement Accuracy (ZR-RX45 only) Resistance temperature detector Pt00 JPt00 Pt000 6: Designate real-time or between-cursors mode (during playback) 7: file max. GB (depending on memory device used) 8: Be sure to use only the AC and AC adaptor provided as accessories. Measurement temperature range ( C) 00 to 850 C (FS = 050 C) 00 to 500 C (FS = 700 C) 00 to 500 C (FS = 700 C) Sensor ZR-XRH (Option) Applied current ma ma 0. ma Measurement accuracy ±.0 C ±0.8 C ±0.8 C ZR-RX70 ZR-RX5/RX45 Operating environment 3 C±5 C Operating environment 3 C±5 C; When 30 minutes or more have elapsed after power was switched on Filter Line/GND connected; Thermocouple used is T: 0.3 dia., others: 0.65 dia. External trigger input ( ch), Input signal level, time, duration When 30 minutes or more have elapsed after power was switched on Sampling s/filter ON (0 times) GND connected Thermocouple used is T: 0.3 dia., others: 0.65 dia. Resistance temperature detector is available only for ZR-RX45. Description Allowable temperature range 5 to 80 C Allowable humidity range 0% to 00% Relative humidity measurement accuracy ±3% (5% to 98% at 5 C) Response time 5 sec (90% response when membrane filter installed) Sensor output 0 to VDC External dimensions dia. 4 mm 80 mm (excluding ) Cable length 3 m Special PC software ZR-SX0 Standard PC software Wave Inspire RX (Since Ver..4) (Option Specifications) Smart Viewer RXW (Since Ver..0) (Standard accessories) Smart Viewer RX70 (Since Ver..0) (Standard accessories) Compatible logger ZR-RX5/RX45/RX70/RX0/RX40 ZR-RX5/RX45/RX0/RX40 ZR-RX70 Compatible operating system Windows XP / Windows Vista / Windows 7 Windows 000 / Windows XP / Windows Vista CPU Intel-compatible, GHz or faster processor recommended, Intel Atom CPU not supported Pentium 4:.0 GHz or faster processor recommended, Intel Atom CPU not supported Memory Windows XP: 5 MB or more Windows Vista / Windows 7:GB or more 5 MB or more (recommended: GB or more) Display 04 768 or higher, screen resolution, 65,535 color (6-bit color) or higher screen display 04 768 or higher screen resolution Compatible interface, LAN Standard functions Review saved data, real-time capture of PC data, main unit setup, CSV file conversion Waveform operation Direct operation of waveform by mouse or icons, Batch processing of selected waveform Change CH scales individually by icons Waveform display Web server function, FTP server function, NTP client function Realtime data transfer to the PC, Unit control from a PC Display graphs in multi-window, X-Y View, FFT View, Handy function of switching waveform, Display function of grouping channel, Scrolling for all directions (up, down, right, left) Web server function, FTP server function, FTP client function, NTP client function, Realtime data transfer to the PC, Unit control from a PC Display in single window, X-Y View between Cursors (only during replay), Display function of grouping channel Configuration function External control of sampling Advanced channel grouping function, Advanced Listview setup function, Main unit setup Channel grouping fuction, Main unit setup Available (can set and display) Captured data Others Binary file (original format): Captured data and the information of graph window are saved. CSV file: Captured data is saved in comma-separated value format: Binary files can be converted to CSV files all at once Cursor function, Comment Input function, Excel transfer function *: Even when using a PC with adequate specifications, capture errors occur at times because the PC is in bad condition. (For example, when other applications are open, or recording medium has no free area.) When you capture data using this software, please close all the other applications and save captured data to the hard disk. *: Don t start up other applications while this software is operating, and don t perform multiple operations. (For example, screen saver, virus scan program, copying and moving files, searching files, etc.) System Configuration Standard set ZR-RX70A- Main unit AC adaptor/ac User s manual Utility disk [ZR-RX common] Special PC Software ZR-SX0 [ZR-RX45 common] Base Set ZR-XRE [For ZR-RX70] BNC-Crocodile Cable ( m) ZR-XRC Model Standard set Data Logger Content of utility disk Standard PC software: Smart Viewer RX70 Special PC software: Wave Inspire RX (Trial version) Manual PDF file DC Cable ( m) ZR-XRD Cable (Accessory, 0.5 m) NEW ZR-RX45A- Main unit AC adaptor/ac User s manual Utility disk Battery Pack ZR-XRB Extension Terminal Set ZR-XRT Model ZR-RX70A- ZR-RX45A- ZR-RX5A- Models compatible with power supply and voltage specifications for each country, as well as conforming to Chinese RoHS are also available. For details, please consult your dealer. Content of utility disk Standard PC software: Smart Viewer RXW Special PC software: Wave Inspire RX (Trial version) Manual PDF file NEW Sensor (3 m) ZR-XRH ZR-RX45 Main unit Base Set (ZR-XRE) Extension Terminal Set (ZR-XRT) ZR-RX5A- Main unit AC adaptor/ac User s manual Utility disk ZR-RX45 Necessary option when channel is enhanced Option Battery Pack Sensor (3 m) DC Cable ( m) Logic Alarm Cable ( m) Base Set (For ZR-RX45) Extension Terminal Set (For ZR-RX45) BNC-Crocodile Cable ( m) (For ZR-RX70) Special PC Software Wave Inspire RX 0 CH 0 0 40 CH Content of utility disk Standard PC software: Smart Viewer RXW Special PC software: Wave Inspire RX (Trial version) Manual PDF file Logic Alarm Cable ( m) ZR-XRL 00 CH 4 00 CH 9 Model ZR-XRB ZR-XRH ZR-XRD ZR-XRL ZR-XRE ZR-XRT ZR-XRC ZR-SX0 Please visit the Omron web site for details on calibration service formats and prices. http://www.fa.omron.co.jp/logger Extensive lineup of temperature detectors also available. For details, please visit the Omron web site. http://www.sokuon.jp 9 0