Tank terminal demonstrates the electrically operated solution for Emergency Shutdown Valves

Similar documents
ROSoV Actuation Solutions

Skilmatic SI3-3 Electric Fail-Safe Actuators

Skilmatic SI 3 Range. Spring-Return and Double-Acting Self-Contained Electro-Hydraulic Actuators. Keeping the World Flowing

3rd Generation Skilmatic SI Range

Skilmatic SI-1Q. Keeping the World Flowing. Spring-Return Electric Quarter-Turn Actuator (65 to 480 Nm)

Modbus. Serial communication and control of Rotork actuators. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

IQ SIL Option. IQ actuators for use in applications up to SIL 3. sira CERTIFICATION

Modbus Actuator Control

Foundation Fieldbus. Serial communication and control of Rotork actuators. Established Leaders in Valve Actuation

IQT 3 rd Generation Intelligent Part-turn Electric Actuator

Established Leaders in Actuation Technology. In-Vision PC based supervisory control. Publication S210E issue 04/03

IQ Pro SIL option TÜV Certified for use in SIL 2 & 3 applications

DTM Solutions. Setup, parameterisation, monitoring, and asset management information. Redefining Flow Control

FUNCTIONAL SAFETY CERTIFICATE

IQ Range Intelligent Electric Actuator

CVA Range. Control and Monitoring Facilities. Keeping the World Flowing

HART. Actuator Control. Redefining Flow Control

Using smart field devices to improve safety system performance

Linked Ship/Shore Emergency Shutdown Systems for Oil and Chemical Transfers

The TVC Positioner is designed to provide precise position control of rotary or linear hydraulic or pneumatic actuated valve systems.

E.CK Centronik Control and Indication Specification CENTRONIK FUNCTION AND PROTECTION DETAILS. Local Control. Local Indication.

Foundation Fieldbus. actuator control. Established Leaders in Actuation Technology. Foundation Fieldbus. Freedom to Choose, Power to Integrate

DeviceNet. Controller Area Network control of Rotork actuators. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

Electric Actuators and Control Systems. Established Leaders in Valve Actuation. Pakscan P3 Systems. Network Control. Publication S000E Issue 05/07

IQM & IQML RANGE CONTROL AND MONITORING FACILITIES. Publication E420E issue 7/02

Established Leaders in Actuation Technology. Pakscan IIE high integrity master station. Publication S110E issue 09/04

HI HIPS Logic Solver (2oo3)

Removal of Hardware ESD, Independent of Safety Logic Solver

Pipeline Unit/Station Control. Combining Unit and Station Control into Siemens PCS 7. Application Brief

T72 - Process Safety and Safety Instrumented Systems

Safety Instrumented Systems: Can They Be Integrated But Separate?

PRM Integration Guide with. MTL 4840 Series HART Multiplexer

Pakscan P3 Wireless Quick Start Guide

Proximity Positioner. ICoT. Valve Monitoring and Control Products WESTLOCK

Safety Instrumented System (SIS)

Mobrey Hydratect 2462

Level Measurement. Tank Level Instruments TLI

DeviceNet. Controller Area Network control of Rotork actuators. Redefining Flow Control

Pakscan P3 System. Network Control. Established Leaders in Actuation Technology

CVA Range. Control and Monitoring Facilities. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

GE Intelligent Platforms PAC8000 RTU

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Products Solutions Services. Functional Safety. How to determine a Safety integrity Level (SIL 1,2 or 3)

Get to know our positioner! One that masters everything: SIPART PS2. Flexibility for all challenges. siemens.com/positioner

Annual Training plan 2018

SCADA System Specification. Vantage Pipeline Project # May 2013

ELB Detection System. Keeping the World Flowing 1. ELB Product Specification. for Pipeline Monitoring and Valve Control

Oil & Gas. Control Control. every move. Pressure Temperature Level Flow

INITIAL FACE OF AUTOMATION PROGRAMMABLE LOGIC CONTROLLER

The LVS Directional Valve with Digital Pilot Control A New Generation

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

MANUAL Functional Safety

Safe & available...vigilant!

Profibus. Serial communication and control of Rotork actuators. Established Leaders in Actuation Technology

Accord Builder. User Guide

Profibus Actuator Control

Keeping the World Flowing. Wireless Valve Monitoring

T57 - Process Safety and Critical Control What Solution Best Meets Your Needs?

TVC POSITIONER.

PipeMonit Swarm. Real-time corrosion and erosion monitoring system. Non-Intrusive Wall Thickness Monitor

SCADA Software. 3.1 SCADA communication architectures SCADA system

VALVE NETWORKING MONITORING AND CONTROL. Monitoring and Control Products & CApabilities

IQT Pro Range. Intelligent Quarter-turn Electric Valve Actuators. Redefining Flow Control

PD 527 Valve Control Module PD Series 600. Product Data Sheet February 2015 SD E06

Installation and Setting up Instructions for the Type 920 Auto Sequencer

Capabilities & Facilities

CVL Range. Linear Control Valve Actuator (CVL) Installation & Maintenance Instructions. Established Leaders in Valve Actuation

F02 SERIES ELECTRIC ACTUATORS

The new reference class F870S

Type 9160 / Transmitter supply unit / Isolating repeater. Safety manual

SIL Safety Manual DOC.SILM.EF.EN, Rev. 0 March EL-O-Matic F-Series Pneumatic Actuator SIL Safety Manual

ELECTRIC ACTUATORS Compact devices for the automation of globe valves, ball valves and butterfl y valves

SVI II ESD. SIL3 Partial Stroke Test Device October 2007 BW5000-ESD. The only SIL3 Smart ESD device that is live during and after a shutdown.

VALLIAMMAI ENGINEERING COLLEGE DEPARTMENT OF ELECTRONICS AND INSTRUMENTATION ENGINEERING QUESTION BANK

CVQ Range. /4 Turn Control Valve Actuator (CVQ) Installation & Maintenance Instructions. Established Leaders in Valve Actuation

INDUSTRIAL CONTROL SYSTEMS & COMPUTER PROCESS CONTROL

IQ Range. Keeping the World Flowing. Remote Hand Station. Safe Use and Installation Manual

Front End Engineering and Design (FEED)

Industrial Sensors. p 00 24, 44, 53

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Relays SAFETY RELAYS SERIES. High Integrity Safety Relays. Suitable for SIL 3 applications according to IEC and IEC D5000 / D1000 SERIES

SIL certified safety for people, the environment and machinery Overview of PROGNOST -SILver safety analyses... 6

General. Remote I/O A4/1.

SIL Safety Manual DOC.SILM.EF.EN Rev. 0 March EL-O-Matic F-Series Pneumatic Actuator SIL Safety Manual

CK Range. Multi-turn Part-turn Control Systems Modular Design Electric Valve Actuators. Keeping the World Flowing

ED17: Architectures for Process Safety Applications

1. Introduction. 2. Design. Safety and Emergency Stop Circuit Design Standard. Safety and Emergency Stop Circuit Design Standard.

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Process Control and Instrumentation Technology Model: PCT-200

IQ Range. Multi-turn and Part-turn Intelligent Electric Valve Actuators. Keeping the World Flowing

UPGRADE. Oil and gas pipeline companies often need to. Sensing a wireless

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT. Test Code: 5936 Version: 01

Installation and operating instructions

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

Executive summary. by Michel Bonnet, Maximilien Laforge, and Jean-Baptiste Samuel

MTL8000-2/x Series Modular I/O

Exercise 5-1. Electrical Circuit and Panel EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Detailed electrical schematic

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

Gallagher Vapour Recovery Monitoring

Initial Face of Automation Programmable Logic Controller

Transcription:

Case Study Tank terminal demonstrates the electrically operated solution for Emergency Shutdown Valves Botlek Tank Terminal Case Study - 26th April 2013

Botlek Tank Terminal Case Study - 26th April 2013 Tank terminal demonstrates the electrically operated solution for Emergency Shutdown Valves Sector: Oil & Gas Category: Electric Actuators, Electro-Hydraulic Actuators, Control Networks, Products: IQ Standard, Skilmatic SI, Pakscan Overview Since the disastrous fire at the Buncefield fuel depot in 2005, much has been done to ensure that such a catastrophic accident should not happen again. Led by COMAH (Competent Authority/Industry Standards Task Group), safeguards have been put in place by the petroleum industry to provide additional safety and environmental protection to tank storage installations. Endorsing the recommendations of the Buncefield Standards Task Group, a key feature of these safeguards is the installation of Remote Operated Shut-off Valves (ROSoV) with failsafe actuation for Emergency Shutdown (ESD) duties. The Reason The majority of ROSoV relevant valves are situated on the inlet and outlet ports of the fuel storage tanks and are designed to isolate individual tanks in the event of a potential emergency. The predominant tank farm actuation technology is electric, which suits the very spacious environments which typify these sites. Within such environments it would be very expensive to install a pneumatic ring main, whilst an electrical source for control and indication is traditionally available on these installations. It therefore makes economic and practical sense to use electricity to power the ESD actuators as well. Designed and built since the Buncefield fire, the Botlek Tank Terminal in Rotterdam is a state-of-theart example of an installation that has adopted an electric solution for all the valve actuation functions associated with routine operations and safety related duties. 2

The Solution The Botlek Tank Terminal (BTT) has 34 storage tanks, providing a combined storage capacity of 200,000 cubic metres, of which 130,000 cubic metres is earmarked for clean fuels and the rest is for edible oils and biodiesel. The terminal has deepwater berths including a 420 metre jetty that can simultaneously accommodate two seagoing vessels and two barges, operating 24 hours-a-day. The terminal utilises Rotork s electric valve actuation technologies for automated flow control and vital safety related duties associated with the import, export and storage of a varied range of liquid bulk products. Over 250 Rotork IQ multi-turn and quarterturn intelligent electric actuators have been installed to operate the valves that control the routine movement of liquids throughout the site. A further 55 Rotork Skilmatic SI self-contained electro-hydraulic actuators have been installed in strategic areas on valves that provide failsafe ESD protection from potential accidents and spillages. The Skilmatic actuators are situated on the inlet and outlet ports of the fuel storage tanks and on the marine and truck loading bays in order to isolate individual tanks and areas in the event of a potential emergency. They are key components in the Safety Instrumented System (SIS) that operates with dedicated level and flow sensors and ESD logic solvers to provide the Botlek site s Safety Instrumented Function (SIF). Skilmatic actuators operate on a pump and bleed principle utilising a motorised vane pump to provide hydraulic pressure in one direction and spring-return in the opposite (bleed) direction. A specialised electric actuator design is necessary to achieve the swift failsafe operation demanded by the ESD duty. Experience has shown that this can be successfully delivered through the electro-hydraulic route. Electro-hydraulic actuators use a simple and therefore very reliable mechanical spring to provide failsafe valve movement, whilst precise and swift valve movement in the opposite direction is achieved hydraulically by means of an integral electrically powered pump. With this design, reliable failsafe performance can be combined with the benefits of the latest electric actuation technologies, facilitating a high level of asset management encompassing accurate control, monitoring and alarm signalling, operational data logging and diagnostics. Further savings in capital and maintenance costs are achieved by the simplification of the overall plant control system that is facilitated by the all-electric solution. All Rotork actuators at BTT feature ATEX explosionproof certification and IP68 double-sealed watertight enclosures designed for harsh and exposed environments. They are monitored and controlled on fully redundant Rotork Pakscan digital bus loops, 3

linked by three Pakscan P3 master stations to the site s central SCADA system. utilisation by identifying potential valve wear problems and facilitating predictive maintenance. Pakscan master stations monitoring and controlling the IQ and Skilmatic SI actuators at BTT on three separate bus networks. Designed specifically for the valve actuation environment, Pakscan incorporates secure field communications with inbuilt network redundancy to maintain control even in the event of equipment or cable failure. The Results A non-intrusive, hand held setting tool is used to programme and commission the Rotork actuators, as well as download diagnostic information stored in dataloggers. All the actuators at BTT share Rotork s IQ nonintrusive setting, commissioning and data communication technologies. A hand held, intrinsically safe, setting tool enables safe and rapid non-intrusive commissioning by means of easy to follow point and shoot menus. The same setting tool also enables actuator configuration and data logger files to be transferred from the field to the office for diagnostics, analysis and storage. In combination with Rotork IQ- Insight software, this data can help to maximise plant IQ intelligent actuator technology is capable of providing a proliferation of data, recording all the activity with an immense amount of detail, including the number of valve operations, alarms, failure to respond events, valve torque profiles, unauthorised operation attempts and many other events. The ability to objectively analyse this information and identify the key areas that are important for each individual site s specific requirements is an essential requirement for effective asset management. For example, there are many different styles of valve and they each have their own unique torque demand curve. Capturing the torque demand curve from a newly installed and calibrated valve actuator assembly provides a reference point against which future curves can be measured. As the valve ages it becomes more difficult to open and close because of internal and external factors. This could be a threaded stem on a rising stem gate valve that has not been lubricated. By identifying issues such as these the software can be used to plan inspection and maintenance without interrupting the plant and improve overall asset management. The incorporation of IQ technology into the Skilmatic SI actuator introduces a high level of control and monitoring functionality, combined with a hardware ESD input for the safety system. Settings such as internal hydraulic pressure, position, limits, control options, alarm and indication functions can be accessed and adjusted. Actuator status, control and alarm icons are viewable on the illuminated LCD display which also provides access to real-time information including pressure, diagnostics and help screens. The Skilmatic control module enables demanding operator requirements to be met, including 4

compatibility with the site s Pakscan digital network control system. Certified to the requirements of IEC61508-2:2010 for use in safety systems performing safety functions up to SIL2 and SIL3, the actuators are also capable of partial stroke testing, enabling isolating valves to be tested without interrupting the process. This is of particular importance to minimise process shut downs when testing safety critical valves. All key components within the actuator including the hydraulic pressure and movement are tested to confirm availability for shutdown on demand. The test can be initiated either remotely or locally with the setting tool. The partial stroke position against stroke time is measured and compared to the original position to stroke time recorded at the commissioning stage. A pass or fail is displayed and, if enabled, a failure alarm will be activated. The alarm is one of three that can be configured to customer specific alarm and status requirements or for general group alarms. A monitor relay is also provided to monitor the power supply and any hardware errors. Electro-hydraulic ESD valve operation Schematic of internal operation of Skilmatic SI actuator When the actuator is commanded to open from the closed limit, the bleed solenoid valves are energised. The motorised vane pump is started under no-load condition as a result of the delay in energising the bypass solenoid valve. With the by-pass solenoid energised, the system pressure acts against a spring opposed piston to drive the actuator in the open direction. When the actuator is commanded to stop or reaches the open limit, the by-pass solenoid valve is de-energised, followed by the motorised vane pump after a preset time unless a new command is given. The bleed solenoid valves remain energised and the system pressure is maintained to hold the actuator position. When the actuator is commanded to close or receives the ESD signal, the by-pass solenoid valve, bleed solenoid valves and motorised vane pump are deenergised. Pressure is released; the hydraulic fluid returns to the reservoir and the spring returns the drive shaft to the closed or safe position. Skilmatic SI actuators are equipped with integral circuitry designed to receive a separately hardwired discrete ESD alarm signal that will override any other input and move the actuator to the pre-determined safe position, even in the event of electrical power failure. The ESD signal can be configured to control the shutdown through a hardwired circuit by-passing the internal processor. This processor circuit monitors the position and internal hydraulic pressure and provides alarm monitoring but the ESD circuit is independent, thereby providing priority to an ESD command. In the ESD scenario the actuator will immediately return to the predetermined safe position and will be ready to operate on the next command when the ESD signal is reinstated. As an added safeguard, an optional ESD manual reset can be enabled to restrict the actuator from operating until locally reset at the actuator or with an externally mounted switch. Closing speeds can be adjusted to meet the specific requirements of the application. 5

ESD separately hardwired PLC control station at BTT Safety Instrumented System to prevent tank over-filling This schematic illustrates the Safety Instrumented System (SIS) as applied to prevent over filling of a tank, which is one of the Skilmatic functions at BTT. The tank and pump are controlled by the DCS (Distributed Control System) and the installation is physically contained within a bund. The signal from the gauge system is feeding back to the PLC in the DCS which controls the pump and the IQ and Skilmatic actuators via the Pakscan network. A fault with the gauge system leaves the tank vulnerable to overfilling. To account for this, the SIS is added, consisting of separate level sensors and an ESD logic solver to control the Skilmatic actuators, which are the final elements under the control of the SIS. The ESD signal is independent to other control signals and ensures the valve in the safe position, providing a Safety Instrumented Function (SIF) for the ESD duty. 6

Rotork plc Brassmill Lane, Bath, UK tel +44 (0)1225 733200 fax +44 (0)1225 333467 email mail@rotork.com