SENSOR RESERVOIR. Telemetric Shunt Control - Reading Inner Values. We understand the gravity of the situation. Aesculap Neurosurgery

Similar documents
Aesculap Trocar Solution

3.0 SEE BETTER. AESCULAP 3D EinsteinVision NEXT GENERATION LAPAROSCOPIC SURGERY

Safil Strong, Safe and Soft

Aesculap Sterile Technology Aesculap Universal Storage System. Organisation and protection of surgical instruments

AESCULAP POWER SYSTEMS CATALOGUE 2018 ELAN 4 and Acculan 3Ti

From Eye to Insight Hand-held, contact-free Optical Coherence Tomography for pediatrics ENVISU C2300 OCT Take OCT to your patient FDA 510(k) Cleared

C2 NerveMonitor Intraoperative Neuromonitoring

Aesculap Electrosurgery Nelson deluxe. Innovative electrosurgery

Type Multichannel Transmitter/Controller multicell for Flow and Analytical Sensors

Family of Diagnostic and Therapeutic Catheters

C2 NerveMonitor Intraoperative Neuromonitoring

FlowAnalyser Product Line

Patient Simulator Series

4 AA nickel-etal bybrid cells (min. 2,200 mah) Use only AC Adapter (5 VDC / min. 1 A) supplied for recharging

GamCath Catheters For Hemodialysis. Product Catalogue

ML7421A,B Electric Linear Valve Actuators

Tablet combination tester. EasyCheck. Easy and fully automatic testing for up to 5 parameters

ALL-IN-ONE TMJ Arthroscope

McCULLOCH. Micro-Discectomy Instruments The premium neurospine retractor system / / / / / / / / / /

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Addendum No. 2 Reference: ITB Procurement of Medical Equipment for the Intensive Care Unit at Alia Hospital Hebron

Disposables the Original by B. Braun

ProfiLine Single Parameter Instruments Data-logging Communication Ground Water Wastewater Mobile Lab Measurements Surface waters Measurements Communic

Butterfly Control Valve. DMK/6 Series

The Next Level of Energy Data Management Fast Data Acquisition via Parameterization No Programming

User Manual Data-Logger Software

DOCUMENTATION MADE FAST, EASY, AND NETWORKED

SUCTION FILTERS. PRESSURE (ISO :2002) Collapse, differential for the fi lter element (ISO 2941): 1 MPa (10 bar)

GEN series G070A. Data sheet. Torque/RPM adapter. Special features

WAGO Energy Data Management Efficiency Is That Easy!

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

WELCOME TO A member of

Bio-logic AuDX, AuDX PRO and NavPRO ONE Viewing and printing test results Quick start guide

Precise results in record time.

Series DMHF Heat Meter

Harrier. Controllers. Electronic Chemical Injection Rate Controllers

Precision platforms for hazardous areas

VICI Vision optical profile scanners quickly and easily measure external dimensional profiles on a wide range of cylindrical parts, including shafts,

Full HD Visual System

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. C-Series Core Sensor, Models CS and CM Analog Outputs (Voltage/Current)

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

Measuring static magnetic fields

CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL

NEW. EBI 40 Multi-Channel Data Logger Channels Large colored display Multifunctional ports. Food

ConTeS. Contamination Test Software. Operating Instruction. Valid from software version: English (translation of original instructions)

Tiny sample. Huge insights. Eurolyser Point-of-Care Systems

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. Accessories Catalog

FlowAnalyser TM Product Line. When it comes to precision, I rely on the Swiss legendary devotion to detail.

B. Braun Interventional Systems Inc. Balloon Dilatation Catheter Family

Flow simulation system PROline FieldCheck

Hand-Held Thermometer Model CTH 6200

Highlights Edition, Quarter 3. Anesthesiology and Emergency Medicine

LiquiDens. SensoTech. Process density meter for liquids Product description

Level Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog

Highlights Edition, Quarter 4. Anesthesiology and Emergency Medicine

Internal Compressor Controller

AME 658 SU/ SD with safety function Motorized actuators for AB-QM valves

The Latest Technology. Digi-Lite TM Key Features & Benefits

EyeMag Loupes from ZEISS Seeing is believing

EE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical

NO COMPROMISE IN AN EMERGENCY CASE

Powers TM Controls RL 243 MP Multi-Purpose Relay

«The compact and mobile testing device for ventilators.»

Fully Automated Formalin Mixing and Dispensing Station

PRODUCT RANGE MEDICAL TEST EQUIPMENT FROM

Ultra Sonic Flowmeter DATASHEET

EyeMag Medical Loupes from ZEISS Seeing is believing

Model KB 400 Cooling incubators with compressor technology

Endress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

QUICK START GUIDE FIRMWARE UPDATE VIA MIRA SOFTWARE APPLICABLE TO ALL PATH MEDICAL DEVICES

Crane-Boy / Crane-BoyP Load limitation electronics

Type Differential pressure transducer

PS600 series For viscous media or contamination

Process Control and Instrumentation Technology Model: PCT-200

InTouch Knowledge Guide

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 & 300

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

RESS. Manual. Rotary-Ball-Camera Pro. The Producer. Visual Inspection Sweep Instruments Measuring Instruments

Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250

INDUSTRY DIVISION. Leica LED2000 & Leica LED2500. Microscope Stand and Illumination in One

URGENT FIELD SAFETY NOTICE DISTRIBUTORS

DATASHEET cm (54.6 ) POS-LINE MONITOR HIGH BRIGHTNESS. DATA DISPLAY GROUP

Leica EM CPD300. Automated Critical Point Dryer Controlled Specimen Drying for Biological and Industrial Applications

Moisture Analysis Balances

seca analytics Quick Start Installation Guide

Precision pressure indicator 1- or 2-channel version Model CPG2500

POWERFUL - VERSATILE - INTUITIVE

FAST EnergyCam. The Smart Clip-on Meter Reader for Home and Business

Leica M525 C40 Leica M525 CT40. Leica ceiling solutions for multidisciplinary use

Oil & Gas. Control Control. every move. Pressure Temperature Level Flow

Flexible Reliable Reproducible Secure Expandable Efficient

Model 601CM. Metal Sealed. Product Features:

Getting Started with ID ISC.LR(M)U1000/2000 UHF-Reader

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

Internal Compressor Controller

Temperature probes 468 Hans Turck GmbH & Co. KG Tel Fax Edition I/

DVM HPHT ULTRA HIGH ACCURACY SIMULTANEOUS DENSITY AND VISCOSITY MEASUREMENT

Infusion Pumps. Website: Kizlon Medical

FOTEMP1 Handheld. FOTEMP1 Handheld is a compact, user-friendly, and easy to operate instrument for many fields of application, e.g.

Transcription:

Telemetric Shunt Control - Reading Inner Values. We understand the gravity of the situation. Gravitational valves by Miethke Aesculap Neurosurgery

Mode of operation The Miethke is the first long-term implantable measuring cell for the measurement of pressures within a shunt system. It is integrated into a reservoir for a ventricular drainage system and transmits pressure values using telemetric methods, thus non-invasively, via a reader unit. The allows, for the first time, the pressure in a shunt system to be measured and evaluated, and integrated into treatment options. 2

In addition to pressure measurement, the offers the same advantages as any other Aesculap-Miethke reservoir. Every is calibrated. The calibration data are stored on an associated SD card that is included with the reservoir. The reservoir membrane permits: the pressure measurement in the shuntsystem the injection of medication fluid removal valve inspections. The measuring cell is protected from possible penetration by a titanium membrane. Membrane Measuring cell Housing 3

Reader Mode of operation The Reader is used to read and display the pressure in the reservoir using telemetric methods. The readings are automatically stored on an SD card and can be evaluated later. The relative behavior of the CSF pressure in the shunt system can provide information about its function. This permits the non-invasive detection, localization, and evaluation of occlusion in the shunt as well as mechanical loss of function of the shunt values. The measured pressure values can also be used to improve the configured opening pressure of adjustable shunt valves. Display Antenna connector Function keys SD card slot Connector for the power supply Antenna 4

There are three measurement types that can be selected in the reader: Individual measurement, continuous measurement and quick measurement. The data are stored by date and time on the SD card and can be evaluated on the reader or on a computer using Excel. The pressure curve is shown in a diagram both on the reader and in the Excel file. Individual measurement Continuous measurement Quick measurement The individual measurement is a static measurement of the current pressure value and is displayed as a digital value averaged from 8 to 10 measurements. The unit of measurement can be selected in the settings. In continuous measurement, the measured values are displayed sequentially as individual measurements in a curve over a configured measurement interval. The quick measurement is a sequence of non-averaged individual measured values at the maximum measurement rate available (about 40 measurements per second*) that can be shown sequentially as a curve. 5

23.8 mm SD card Art. no. FV911X Product with SD card 6

with distal catheter 23.8 mm 600 mm Distal catheter SD card Art. no. FV912X Product with 600mm distal catheter and its SD card 7

Reader Reader Art. no. FV905X Product Reader for the 8

SD card for the Art. no. FV906X Product SD memory card for telemetric shunt sensor, memory for calibration data, patient data and readings 9

Our shunt systems your choice Shunt system Description Indication Patient Property 3-Tesla MR Conditional Feedback Mechanism Gravitational unit lying active LP NPH Pediatric HC Adult HC prosa Adjustable gravitational unit with differential pressure valve progav Adjustable differential pressure valve with gravitational unit progav 2.0 Adjustable differential pressure valve with gravitational unit GAV Gravitational valve for the treatment of adult hydrocephalus paedigav Gravitational valve for the treatment of pediatric hydrocephalus SHUNTASSISTANT DUALSWITCH VALVE Gravitational unit for integration into shunt systems to avoid overdrainage Gravitational valve with high flow volume for CSF mininav Accessories Differential pressure valve specifically for premature infants and newborns or non-mobile patients who are confined to bed * * in combination with SHUNTASSISTANT or prosa 10

We understand the gravity of the situation. Miethke Gravitational Valves Aesculap AG Am Aesculap-Platz 78532 Tuttlingen Germany Tel. +49 7461 95-0 Fax +49 7461 95-26 00 www.aesculap.de 11

Manufacturer acc. MDD 93/42/EEC Christoph Miethke GmbH & Co. KG Ulanenweg 2 14469 Potsdam Germany Tel. +49 331 62 083-0 Fax +49 331 62 083-40 www.miethke.com Sales Austria B. Braun Austria GmbH Aesculap Division Otto Braun-Strasse 3-5 2344 Maria Enzersdorf Tel. +43 2236 4 65 41-0 Fax +43 2236 4 65 41-177 www.bbraun.at Sales Switzerland B. Braun Medical AG Aesculap Division Seesatz 17 6204 Sempach Tel. +41 58 258 50 00 Fax +41 58 258 60 00 www.bbraun.ch Aesculap AG Am Aesculap-Platz 78532 Tuttlingen Germany Tel. +49 7461 95-0 Fax +49 7461 95-26 00 www.aesculap.com Aesculap a B. Braun company The product brands "DUALSWITCH VENTIL", "GAV, "mininav, "paedigav, "progav, "progav 2.0, "prosa, "SHUNTASSISTANT and "" are registered trademarks of Christoph Miethke GmbH & Co. KG. The main product mark 'Aesculap' is a registered trademark of Aesculap AG. Subject to technical changes. This brochure may only be used for the exclusive purpose of obtaining information about our products. Reproduction in any form partial or otherwise is not permitted Brochure no. C27501 0615/0.5/2