Light Control SLS ADRIA

Similar documents
Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

PHOENIX CONTACT - 07/2006

Product and functional description

KNX DALI Gateway Plus - User Manual

QUINT-BUFFER/24DC/24DC/40

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

EX-RC1 Remote I/O Adapter

Operating instructions. Standstill monitor A / / 2011

Operating Instructions Differential Pressure Transducer PS27

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

COMPACT LED CONVERTERS 48 V

TRIO-DIODE/12-24DC/2X10/1X20

Power Supply HARTING pcon

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , ,

Product and functional description

Power Supply HARTING pcon

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Operating Instructions VEGAMET 381

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

CC COMPACT DIP SWITCH

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Product and functional description

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

LinkRay LED Drivers EasyLine With Selectable Current , Typical Applications

Installation instructions Inclination sensor EC2019 EC / / 2013

Product and functional description

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Quick reference guide 3D sensor O3D3xx

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

Model HM-535 Power Supply Installation and Service Instructions

Installation and Operating Manual. VPC Merkur No. 5744

Extension module for lighting control

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

STEP-PS/1AC/24DC/1.75

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Assembly instruction / User manual

MINI-PS AC/10-15DC/8

Installation instructions Ethernet switch EC / / 2011

Operating Instructions. DALI-Gateway

Electrical devices may only be mounted and connected by electrically skilled persons.

Industrial motor controller for brushed DC motors 24 VDC

Operating Instructions

PHOENIX CONTACT - 01/2007

EX-RC1 Remote I/O Adapter

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

DuoFern Multiple Wall Controller

CPCI-PS24 24V-Power Supply

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

5 B&W Rear View System Camera

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EX-RC1 Remote I/O Adapter

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Industrial motor controller for brushed DC motors 24 VDC

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

High Speed Remote I/O Module

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

icore Kiosk system Installation Guide

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Supplementary operating instructions for your air curtain system Controller TMC 500

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

Redundancy Module QUINT-DIODE/40

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Transcription:

Instruction and Mounting Manual Light Control SLS ADRIA 1 Introduction... 2 2 Safety instructions... 2 2.1 Meaning of the safety symbols... 2 2.2 General safety information... 2 3 Brief description... 3 4 Components... 3 5 Mode of operation... 4 5.1 Basic functions... 4 5.2 Operating panels... 4 5.3 External button... 4 5.4 Special functions... 5 5.4.1 Energy-saving mode STANDBY... 5 5.4.2 Reserve connection... 5 6 Mechanical installation... 5 6.1 SLS94H control... 5 6.2 SLS26KT operating panel... 6 6.3 SLS63KT operating panel... 6 7 Electrical connection... 7 7.1 Location of the SLS94H connection points... 7 7.2 Connection to power supply... 7 7.2.1 12VDC (line 1-3)... 7 7.2.2 GND (line 1-3)... 7 7.3 Connection of lamps to channels... 7 7.4 Connection SLS26KT (I) with cable SLS19KT... 8 7.5 Connection SLS26KT (II) with cable SLS29KT... 8 7.6 Connection SLS63KT with cable SLS09KT/SLS39KT... 9 7.7 Connection of external buttons... 9 8 First start-up... 9 8.1 Check before start-up... 9 8.2 Start-up... 9 9 System malfunctions... 10 10 Technical data... 11 10.1 Environmental conditions... 11 10.2 Voltage supply... 11 10.3 Outputs K1-K9... 11 11 Declaration of conformity... 11 Page 1 of 11

1 Introduction This instruction and mounting manual contains important notes regarding the connection and safe operation of the device. You are urgently required to read and observe the safety instructions mentioned herein. The instruction and mounting manual must be carried inside the vehicle at alll times. All safety regulations should also be communicated to other users. 2 Safety instructions 2.1 Meaning of the safety symbols DANGER! Ignoring this sign may threaten life and limb. WARNING! Ignoring this sign may lead to injuries to persons. NOTE! Ignoring this sign may damage the device or connected loads. This sign refers to recommendations or particularities. 2.2 General safety information The device is built according to state-of-the-art technology and the generally recognised technical safety regulations. If the safety instructions contained in this instruction manual are ignored, however, persons may be injured or the device may be damaged. Only use the device in a technically faultless condition. Ensure that any faults affecting the safety or security of persons or the devicee are eliminated by qualified personnel immediately. Danger! The electrical system of the camper or caravan must comply with valid DIN, VDE and ISO standards. Do not manipulate the electrical system in any way. Do not make any changes to the device. The electrical connection must only be carried out according to the instruction manual by qualified personnel trained for that purpose. Do not put the device into operation if the connection or any cables are faulty. Do not carry out any maintenance work on the device if voltage is applied. Implement electrical connections properly. Ensure that the correct electrical fuse is used. NOTE! Risk of overheating! Damage to devices is possible. Maintain a sufficient distance to furniture and fixtures. Do not block ventilation slots. Page 2 of 11

3 Brief description Your vehicle is equipped with a central light system designed for both the switching and dimming of individual light circuits (channels). It also has three scene functions that make it possible to save a preferred illumination situation of the vehicle as a scene or recall it. The system features a power-save mode and switches to STANDBY mode if not used for a long time. An automatically operated K9 channel operates additional light circuits with an own switch e.g. wet rooms, wardrobe lights or even reading lights. The K9 channel is only deactivated if the system is in STANDBY mode. 4 Components The SLS ADRIA light control is only used to control the 12V living space lighting of the camper or the caravan. The scope of the SLS ADRIA light control includes: a) One operating panel featuring 7 buttons with associated SLS43KT mounting frame b) One or two operating panels featuring 3 buttons with associated SLS44KT mounting frame c) SLS94H control d) The required connecting cables between the control and the operating panel Schema Button (optional) 12VDC Voltage supply SLS94H K1-K9 The SLS ADRIA light control is only intended to be connected to a 12V voltage supply (DC). At the voltage supply, supply lines 1 to 3 must be fused at the maximum permissible current of the voltage supply but not at more than 15A respectively. The supply lines must furthermore not be fused in a combined way on only one cable together with the total current! The voltage supply must definitely be configured for the required current. A 12V accumulator to buffer and balance short-term current peaks (e.g. when switching on) is advantageous for stable supply; however, please follow the instruction manual of the voltage supply also in this case. The SLS ADRIA light control is protected against pole reversal of the supply connections. The outputs K1 to K8 are protected against excess temperatures, overload and short circuits, K9 against short circuits because of the fusing of the line 3 voltage supply. Ongoing faulty operating states, such as pole reversal, short circuits or overload, should nevertheless be avoided to avoid damage to the light control. Page 3 of 11

5 Mode of operation 5.1 Basic functions Function K1 K8 Button S1 S2 System is SWITCHED ON/ACTIVE System in STANDBY Short actuation Long actuation Actuation for approx. 0.5s Switching on or off channel Dimming 2)5) Channel K1 K8 Switching on channel K1 K8 4) K1 K8; when switching on, the last brightness level prior to switching off is assumed Like function K7 Like function K7 Like function K7 4) Switching on SCENE 1 Programs 3) current setting as SCENE 1 Switching on SCENE 1 4) Switching on SCENE 2 Programs 3) current setting as SCENE 2 Switching on SCENE 2 4) Standby 1) Programs 3) current setting as Switching on SCENE Coming COMING HOME home 3) Note: 1) Channel K9 is switched off as well 2) Button must be actuated for at least 1 second. After switching on the channel, the intensity is first reduced, then the intensity is increased or reduced alternately when the button is actuated again 3) Button must be actuated for at least 10 seconds; programming is acknowledged by the channels K1-K8 being switched off temporarily 4) Channel K9 is always switched on as well 5) May be deactivated for individual channels, depending on the equipment 5.2 Operating panels SLS26KT (I) SLS26KT (II) SLS63KT S1 S2 K5 K6 K7 K8 K3 K4 K1 K2 The actual keyboard configuration may differ in individual cases. 5.3 External button The external button "coming home" corresponds to the function K7 of the panel. Page 4 of 11

5.4 Special functions 5.4.1 Energy-saving mode STANDBY Light control switches to STANDBY mode (switching off of the light circuits) if, in the ACTIVE mode, 1. The button is actuated 2. No button is actuated within 24 hours. The maximum operating current of the light control in STANDBY is 2mA 5.4.2 Reserve connection Should the light control fail, it is still possible to provisionally connect a lamp to the X15 position. Since X15 is directly connected to the line 3 supply line, it must be observed that the maximum current of line 3 on the supply side must not be exceeded (see chapter 4). 6 Mechanical installation 6.1 SLS94H control Mounting Wall mounting vertically in all 4 directions Floor mounting lying horizontally Distances At least 50mm to all sides except for the mounting surface Air exchange via convection necessary Fixing Fixing is done using four tapping screws Ø3.5 in the designated mounting holes on a solid and plane surface For mounting, the cover must be removed and snapped in again afterwards. Page 5 of 11

6.2 SLS26KT operating panel Mounting Wall mounting vertically in all 4 directions Ceiling mounting horizontally overhead Distances At least 20mm to all sides except for the mounting surface Fixing The SLS44KT frame is fixed on a solid and plane surface using four screws Ø2.9 in the designated mounting holes (Mounting holes) (SLS26KT) After mounting the frame, the cable is attached and the operating panel snapped into the frame 6.3 SLS63KT operating panel Mounting Wall mounting vertically in all 4 directions Ceiling mounting horizontally overhead Distances At least 20mm to all sides except for the mounting surface Fixing The SLS 43KT frame is fixed on a solid and plane surface using four screws Ø2.9 in the designated mounting holes (Mounting holes) (SLS63KT) After mounting the frame, the cable is attached and the operating panel snapped into the frame Page 6 of 11

7 Electrical connection 7.1 Location of the SLS94H connection points The location of the SLS94H connection points can be seen from the nameplate: 7.2 Connectionn to power supply The power supply is connected to the terminals. 12VDC (line 1-3) for 12V (maximum recommended cable length 2.5m) GND (line 1-3) for ground (maximum recommended cable length 2.5m) 7.2.1 12VDC (line 1-3) Power supply 12VDC 12VDC 1 Mind. 2.5mm² SLS94H 12VDC Push-on receptacle 6.3 x 0.8 Pin Fct 1 12VDC 7.2.2 GND (line 1-3) Power supply ground SLS94H GND Push-on receptacle 6.3 x 0.8 angled Pin Fct Ground 1 2.5mm² 2.5mm² *) 1 GND Ground 2 2.5mm² 6mm² 2.5mm² *) 2 GND Ground 3 2.5mm² 2.5mm² *) 3 GND The length of the cable sections marked with *) should not exceed 50mm. 7.3 Connectionn of lamps to channels The lamps are connected to the individual channels using push-on receptacles 6.3x0.8 at the terminals marked with K1-K9 The cable cross section of the connection lines must be at least 1mm² Distribution channels maximum power loss per channel: K1 K2 K3 K4 K5 K6 K7 K8 K9 Line 1 X X X X Line 2 X X X Line 3 P maxchannel 90W 90W 90W 90W 90W 90W 90W X 90W X 180W P maxline 180W 180W 180W The maximum power loss of line 1-3 (per 180W or max. power of power supply) must not be exceeded The max. cable length is 15m Not suitable for LED lamps with ballast Page 7 of 11

7.4 Connectionn SLS26KT (I) with cable SLS19KT SLS94H SUB LUMBERG 3823 14 GND 1 Wire 1 n.c. 2 Wire 2 I/O 3 Wire 3 GND 4 Wire 4 S2 5 S1 6 K8 7 K7 8 K6 9 Wire 5 K5 10 Wire 6 K4 11 K3 12 K2 13 K1 14 Ribbon cable 6xAWG26 SLS26KT LUMBERG MICA 06 Pin Fct Wire 1 1 GND Wire 2 2 n.c. Wire 3 3 I/O Wire 4 4 GND Wire 5 5 SW2 Wire 6 6 SW1 The cable length is 15m SW1 SW2 7.5 Connectionn SLS26KT (II) with cable SLS29KT SLS94H SUB LUMBERG 3823 14 GND 1 Wire 1 n.c. 2 Wire 2 I/O 3 Wire 3 GND 4 Wire 4 S2 5 S1 6 K8 7 Wire 5 K7 8 Wire 6 K6 9 K5 10 K4 11 K3 12 K2 13 K1 14 Ribbon cable 6xAWG26 SLS26KT LUMBERG MICA 06 Pin Fct Wire 1 1 GND Wire 2 2 n.c. Wire 3 3 I/O Wire 4 4 GND Wire 5 5 SW2 Wire 6 6 SW1 The cable length is 15m SW1 SW2 Page 8 of 11

7.6 Connectionn SLS63KT with cable SLS09KT/SLS39KT SLS94H SUB LUMBERG 3823 14 GND 1 Wire 1 n.c. 2 Wire 2 I/O 3 Wire 3 GND 4 Wire 4 S2 5 Wire 5 S1 6 Wire 6 K8 7 K7 8 K6 9 K5 10 K4 11 Wire 7 K3 12 Wire 8 K2 13 Wire 9 K1 14 Wire 10 Ribbon cable 10xAWG26 SLS63KT LUMBERG MICA 10 Pin Fct Wire 1 1 GND Wire 2 2 n.c. Wire 3 3 I/O Wire 4 4 GND Wire 5 5 SW2 Wire 6 6 SW1 Wire 7 7 SW4 Wire 8 8 SW3 Wire 9 9 SW6 Wire 10 10 SW5 The cable length is 5m (SLS09KT) or 15m (SLS39KT) SW1 SW2 SW3 SW4 SW5 SW6 7.7 Connectionn of external buttons SLS94H BUTTON LUMBERG 3114 04 n.c. 1 n.c. 2 BUTTON 3 GND 4 The max. cable length is 15m Ribbon cable 2xAWG26 or LiYY 2x0.14mm² Button Pin Fct BUTTON GND 8 First start-up 8.1 Check before start-up 1. Checking all cable connections (proper connection, damage, short circuits) 2. Checking correct polarity of the connecting lines to the power supply 3. Checking of the line 1 to 3 fusing on the power supply 8.2 Start-up 1. Switching on power supply unit 2. Actuation of button on the panel to activate the system 3. Checking all key functions 4. Actuation of button on the panel to deactivate the system ("STANDBY")) Page 9 of 11

9 System malfunctions In most cases, a malfunction of the light control can be traced back to faulty lamps or fuses; these should therefore be checked first. If you cannot eliminate specialist dealer. malfunctions on your own by means of the subsequent table, please contact your If this is not possible, e.g. due to a stay abroad, a specialist workshop can also carry out the repair work. In this case, it must be noted that the warranty is forfeited if the repair work has been carried out improperly and ABL SURSUM is not liable for any consequential damage. Malfunction No lamp can be switched Individual lamps cannot be switched Operating panel without function External button without function All lamps are always on Possible cause No supply voltage SLS94H faulty Lamp faulty Faulty cable to lamp No supply voltage of the corresponding Line Faulty cable Faulty operating panel Faulty cable Faulty button Faulty external button Polarity of supply lines is reversed Remedy Check fuses of the voltage supply Check supply lines for cable break Check if the plug at SLS94H and the voltage supply are in their correct places Contact customer service Temporary solution acc. to 5.4.2 Check illuminant Check cable for short circuit or cable break Check if the plug at SLS94H is in its correct place Check the voltage supply fuse of the corresponding line Check supply line of the corresponding line Check if the plug at SLS94H and the voltage supply are in their correct places Check cable for short circuit or cable break Check if the plug at the operating panel and SLS94H are in their correct places Contact customer service Check cable for short circuit or cable break Check if the plug at the button and SLS94H are in their correct places Check button for function Contact customer service Check connection supply lines at voltage supply Page 10 of 11

10 Technical data 10.1 Environmental conditions Ambient temperature (storage) -30 C 85 C Ambient temperature (operation) -20 C 50 C Humidity 10% 90% rh (not condensing) 10.2 Voltage supply Line 1 Line 2 Line 3 10V 15V, max. 15A 10V 15V, max. 15A 10V 15V, max. 15A 10.3 Outputs K1-K9 Max. individual power K1-K8 90W or 7.5A Max. individual power K9 180W or 15A Max. total power K1-K3 180W or 15A Max. total power K4-K7 180W or 15A Max. total power K8-K9 180W or 15A 11 Declaration of conformity hereby confirms that the components of the SLS ADRIA light control meet the requirements of the guidelines and standards mentioned above: Directive on the radio interference (electromagnetic compatibility) of vehicles 72/245/EEC in the version 2006/28/EC Page 11 of 11