SIPART PS2. Smart Valve Positioner. Venting Gauge Block. Installation Instructions. Answers for industry.

Similar documents
SIPART PS2. Smart Valve Positioner. Integral Volume Booster. Installation Instructions. Answers for industry.

SIPART PS2. Smart Valve Positioner. Integral Volume Booster. Installation Instructions. Answers for industry.

SIPART PS2. Smart Valve Positioner. Integral Volume Booster. Installation Instructions. Answers for industry.

Readme SiVArc V14 SP1 Update 6

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Operating Instructions SIPART. Electropneumatic positioners SIPART PS2 with PROFIBUS PA. Edition 10/2013. Answers for industry.

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

PD PA AP How To Configure Maxum II TimeServer Access

COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

Temperature transmitters SITRANS TF, HART. Operating instructions July 2012 SITRANS. Answers for industry.

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

B63/ NS MS. EtherNet/IP LINK

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

Point Level Transmitters. Pointek CLS200 (Standard) Functional Safety Manual 02/2015. Milltronics

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

SITRANS TF with and without HART SITRANS. Temperature transmitter SITRANS TF with and without HART. Introduction 1. Safety information.

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

Operating Instructions

Converter SINAMICS G150. Type 6SL37102G

Settings. Prior information notice 1. Introduction to "Settings" 2. User rights in "Settings" 3. Settings interface 4.

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

Compact Operating Instructions SIPART PS2 (6DR5...) Electropneumatic positioners.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

Siemens Drives & PLCs

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

COMOS. Operations MRO. Introduction 1. Maintenance objects 2. "General maintenance" plugins 3. "Events" plugin 4. "Resources" plugin 5

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

Siemens Industrial s

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

COMOS. Operations MRO (Maintenance Repair and Overhaul) Introduction 1. Maintenance objects 2. "General maintenance" plugins 3.

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

SIPART PS2 (6DR5...) Electropneumatic positioners. Compact Operating Instructions. Answers for industry.

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

COMOS. Operations Shutdown. Introduction 1. Milestones 2. "Shutdown management" plugin 3. "Quick edit" plugin 4. User interface reference 5

SIPART. Electropneumatic positioners SIPART PS2 with and without HART. Operating Instructions. Answers for industry.

Portable & Direct COMOS. Operations Portable & Direct. Trademarks 1. Introduction. Portable 3. "Direct" plugin 4. User interface reference

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

COMOS. Lifecycle 3D Integration Operation. COMOS PDMS Integration 1. Material management 2. COMOS 3D viewing 3. References 4.

Installation manual plugs and connectors with screw connection (16/32 A)

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

COMOS. Lifecycle Material Management. General information 1. Introduction 2. Definitions 3. Creating material in COMOS 4

COMOS. Lifecycle 3D Integration Operation. Publisher 1. COMOS PDMS Integration 2. Material management 3. COMOS 3D viewing 4.

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Appendix. 9/2 SITRAIN - Training for Industry. PIA Life Cycle Portal. 9/5 Delivery time. 9/6 Pressure Equipment Directive (97/23/EC)

Transcription:

SIPART PS2 Smart Valve Positioner Venting Gauge Block Installation Instructions Edition 12/2014 Answers for industry.

Introduction 1 Safety notes 2 SIPART PS2 Smart Valve Positioner Venting Gauge Block Installation Instructions Installing/mounting 3 Service and maintenance 4 Dimension drawings 5 Hardware Installation Manual 12/2014 A5E34388399-AD

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY Order number: A5E34388399 P 12/2014 Subject to change Copyright Siemens AG 2014. All rights reserved

Table of contents 1 Introduction... 5 1.1 History... 5 1.2 Checking the consignment... 5 1.3 Transportation and storage... 6 1.4 Notes on Warranty... 6 2 Safety notes... 7 2.1 Warning Symbols... 7 2.2 Laws and directives... 8 2.3 Conformity with European directives... 8 2.4 Loss of safety of device with type of protection "Intrinsic safety Ex i"... 9 3 Installing/mounting... 11 3.1 Basic Safety Instructions... 11 3.1.1 Improper Commissioning... 11 3.1.2 Unsuitable Compressed Air... 13 3.1.3 Prior to working on the control valve... 13 3.1.4 Proper Mounting... 14 3.2 Introduction... 15 3.3 Pneumatic Connections... 16 4 Service and maintenance... 19 4.1 Maintenance... 19 5 Dimension drawings... 21 5.1 Installation and Outline Drawings... 21 Index... 23 Tables Table 3-1 Weight... 15 Figures Figure 3-1 SIPART PS2 Venting Gauge Block... 15 Hardware Installation Manual, 12/2014, A5E34388399-AD 3

Table of contents 4 Hardware Installation Manual, 12/2014, A5E34388399-AD

Introduction 1 These instructions contain all information required to commission and use the device. Read the instructions carefully prior to installation and commissioning. In order to use the device correctly, first review its principle of operation. The instructions are aimed at persons mechanically installing the device, connecting it electronically, configuring the parameters and commissioning it, as well as service and maintenance engineers. 1.1 History The contents of these instructions are regularly reviewed and corrections are included in subsequent editions. We welcome suggestions for improvement. The following table shows the most important changes in the documentation compared to each previous edition. Edition Remarks 10/2014 First edition of Installation Instructions for the SIPART PS2 Venting Gauge Block. 1.2 Checking the consignment 1. Check the packaging and the delivered items for visible damage. 2. Report any claims for damages immediately to the shipping company. 3. Retain damaged parts for clarification. 4. Check the scope of delivery by comparing your order to the shipping documents for correctness and completeness. WARNING Using a damaged or incomplete device Danger of explosion in hazardous areas. Do not use damaged or incomplete devices. Hardware Installation Manual, 12/2014, A5E34388399-AD 5

Introduction 1.3 Transportation and storage 1.3 Transportation and storage To guarantee sufficient protection during transport and storage, observe the following: Keep the original packaging for subsequent transportation. Devices/replacement parts should be returned in their original packaging. If the original packaging is no longer available, ensure that all shipments are properly packaged to provide sufficient protection during transport. Siemens cannot assume liability for any costs associated with transportation damages. CAUTION Insufficient protection during storage The packaging only provides limited protection against moisture and infiltration. Provide additional packaging as necessary. 1.4 Notes on Warranty The sales contract contains the entire obligation of Siemens. The warranty contained in the contract between the parties is the sole warranty of Siemens. Any statements continued herein do not create new warranties or modify the existing warranty. For warranty and non-warranty service, refer to Customer/Product Support in this publication. All product designations may be trademarks or product names of Siemens Industry, Inc. or other supplier companies whose use by third parties for their own purposes could violate the rights of the owners. Siemens Industry, Inc. assumes no liability for errors or omissions in this document or for the application and use of information in this document. The information herein is subject to change without notice. Procedures in this document have been reviewed for compliance with applicable approval agency requirements and are considered sound practice. Neither Siemens Industry, Inc. nor these agencies are responsible for product uses not included in the approval certification(s) or for repairs or modifications made by the user. 6 Hardware Installation Manual, 12/2014, A5E34388399-AD

Safety notes 2 This device left the factory in good working condition. In order to maintain this status and to ensure safe operation of the device, observe these instructions and all the specifications relevant to safety. Observe the information and symbols on the device. Do not remove any information or symbols from the device. Always keep the information and symbols in a completely legible state. 2.1 Warning Symbols Symbol Explanation Consult operating instructions Hot surface Dangerous electrical voltage Corrosive materials Toxic materials Isolate the device from power using a circuit-breaker Protect the device from impact otherwise loss of degree of protection Protective insulation; device in protection class II Hardware Installation Manual, 12/2014, A5E34388399-AD 7

Safety notes 2.2 Laws and directives 2.2 Laws and directives Observe the test certification, provisions and laws applicable in your country during connection, assembly and operation. These include, for example: National Electrical Code (NEC - NFPA 70) (USA) Canadian Electrical Code (CEC) (Canada) Further provisions for hazardous area applications are for example: IEC 60079-14 (international) EN 60079-14 (EC) 2.3 Conformity with European directives The CE marking on the device shows conformity with the regulations of the following European guidelines: Electromagnetic Compatibility EMC 2004/108/EC Atmosphère explosible ATEX 94/9/EC LVD 2006/95/EC Directive of the European Parliament and of the Council on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC. Directive of the European Parliament and the Council on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres. Directive of the European Parliament and of the Council of the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits. The applied standards can be found in the EC conformity declaration of the device. WARNING Improper device modifications Danger to personnel, system and environment can result from modifications to the device, particularly in hazardous areas. Only carry out modifications that are described in the instructions for the device. Failure to observe this requirement cancels the manufacturer's warranty and the product approvals. 8 Hardware Installation Manual, 12/2014, A5E34388399-AD

Safety notes 2.4 Loss of safety of device with type of protection "Intrinsic safety Ex i" Qualified personnel for hazardous area applications Persons who install, connect, commission, operate, and service the device in a hazardous area must have the following specific qualifications: They are authorized, trained or instructed in operating and maintaining devices and systems according to the safety regulations for electrical circuits, high pressures, aggressive, and hazardous media. They are authorized, trained, or instructed in carrying out work on electrical circuits for hazardous systems. They are trained or instructed in maintenance and use of appropriate safety equipment according to the pertinent safety regulations. WARNING Unsuitable device for the hazardous area Danger of explosion. Only use equipment that is approved for use in the intended hazardous area and labelled accordingly. 2.4 Loss of safety of device with type of protection "Intrinsic safety Ex i" WARNING Loss of safety of device with type of protection "Intrinsic safety Ex i" If the device has already been operated in non-intrinsically safe circuits or the electrical specifications have not been observed, the safety of the device is no longer ensured for use in hazardous areas. There is a danger of explosion. Connect the device with type of protection "Intrinsic safety" solely to an intrinsically safe circuit. Observe the specifications for the electrical data on the certificate and/or in Chapter "Technical data". Hardware Installation Manual, 12/2014, A5E34388399-AD 9

Safety notes 2.4 Loss of safety of device with type of protection "Intrinsic safety Ex i" 10 Hardware Installation Manual, 12/2014, A5E34388399-AD

Installing/mounting 3 3.1 Basic Safety Instructions 3.1.1 Improper Commissioning WARNING Improper commissioning These instructions are valid solely for the installation and commissioning of the Booster. It is absolutely necessary that you follow the safety rules, notes and requirements of the compact operating instructions before assembly, commissioning and also during operation of the positioner. You can find the compact operating instructions on the supplied CD or on the Internet under: http://www.siemens.com/processinstrumentation/documentation (http://www.siemens.com/processinstrumentation/documentation) WARNING High operating force with pneumatic actuators Risk of injury when working on control valves due to the high operating force of the pneumatic actuator. Please observe the corresponding safety instructions for the pneumatic actuator in use. WARNING Lever for position detection Danger of crushing and shearing with mounting kits which use a lever for position detection. During commissioning and ongoing operation, severing or squeezing of limbs could occur as a result of the lever. Risk of injury when working on control valves due to the high operating force of the pneumatic actuator. Do not reach into the range of motion of the lever following mounting of the positioner and mounting kit. Hardware Installation Manual, 12/2014, A5E34388399-AD 11

Installing/mounting 3.1 Basic Safety Instructions WARNING Impermissible accessories and spare parts Danger of explosion in areas subject to explosion hazard. Only use original accessories or original spare parts. Observe all relevant installation and safety instructions described in the instructions for the device or enclosed with the accessory or spare part. WARNING It is possible to damage the cover gasket If the cover gasket is not positioned correctly in the groove of the base plate, it could be damaged when the cover is mounted and screwed tight. Therefore make sure that the gasket is seated correctly. WARNING Open cable inlet or incorrect cable gland Danger of explosion in hazardous areas. Close the cable inlets for the electrical connections. Only use cable glands or plugs which are approved for the relevant type of protection. WARNING Exceeded maximum ambient or process media temperature Danger of explosion in hazardous areas. Device damage. 12 Hardware Installation Manual, 12/2014, A5E34388399-AD

Installing/mounting 3.1 Basic Safety Instructions 3.1.2 Unsuitable Compressed Air NOTICE Caution Use of process fluids other than instrument air is not recommended. No claim is made as to the suitability of this product for use with other process fluids. 3.1.3 Prior to working on the control valve CAUTION Please note the following before working on the control valve and when attaching the positioner Danger of injury. Prior to working on the control valve, you must move the control valve into a completely unpressurized. Proceed as follows: Depressurize the actuator chambers. Switch off the supply air PZ. Lock the valve in its position. Make sure that the valve has reached the unpressurized state. If you interrupt the pneumatic auxiliary power to the positioner, the unpressurized position may only be reached after a certain waiting time. When mounting, observe the following sequence imperatively to avoid injuries or mechanical damage to the positioner/mounting kit: Mount the positioner mechanically. Connect the electrical auxiliary power supply. Connect the pneumatic auxiliary power supply. Commission the positioner. WARNING Mechanical impact energy In order to ensure the degree of protection of the housing (IP66), protect the housing versions of the positioners listed here from mechanical impact energy: 6DR5..3; not greater than 2 Joule 6DR5..0; not greater than 1 Joule 6DR5..1 with inspection window; not greater than 1 Joule Hardware Installation Manual, 12/2014, A5E34388399-AD 13

Installing/mounting 3.1 Basic Safety Instructions 3.1.4 Proper Mounting NOTICE Incorrect mounting The device can be damaged, destroyed, or its functionality impaired through improper mounting. Before installing ensure there is no visible damage to the device. Make sure that process connectors are clean, and suitable gaskets and glands are used. CAUTION Loss of degree of protection Damage to device if the enclosure is open or not properly closed. The degree of protection specified on the nameplate is no longer guaranteed. Make sure that the device is securely closed. 14 Hardware Installation Manual, 12/2014, A5E34388399-AD

Installing/mounting 3.2 Introduction 3.2 Introduction In that condition where you are using a Double Acting SIPART PS2 with a Single Acting actuator, the following must be considered: With loss of supply air the Double Acting SIPART PS2 will lock in the last position. This prevents the actuator spring from returning the valve to its fail-safe position. By using the "venting" gauge block and properly piping the positioner to the actuator the air on the side opposite the spring can be exhausted back through the air supply line. Figure 3-1 SIPART PS2 Venting Gauge Block Specifications Supply Pressure = 7 BAR (101.5 PSI) Table 3-1 Venting Gauge Block Weight Makrolon Explosion Proof With PS2 Kit only With PS2 Kit only 1.7 kg (3.8 lbs) 680.39 g (1.5 lbs) 5.3 kg (11.6 680.39 g (1.5 lbs) lbs) Ordering Information The booster can be ordered as a kit to add to an existing positioner in the field, or can ordered as an option on a new unit. Kit Numbers 6DR4004-2RF Venting Gauge Block, Double Acting, ¼ NPT connections 6DR4004-2RE Venting Gauge Block, Double Acting, G 1/4 connections Hardware Installation Manual, 12/2014, A5E34388399-AD 15

Installing/mounting 3.3 Pneumatic Connections Model Option Codes R2F Venting Gauge Block, Double Acting, ¼ NPT connections R2E Venting Gauge Block, Double Acting, G 1/4 connections 3.3 Pneumatic Connections Refer to Installation drawings for the locations of the pneumatic connections. The supply and output connections are 1/4" NPT. Ideally the SIPART PS2 Venting Gauge Block assembly should be close coupled to the actuator. Tubing of 1/4" O.D. or larger is recommended for piping. Blow out all piping before connections are made to prevent the possibility of dirt or chips entering the relay. Use pipe sealant sparingly, and then only on the male threads. A nonhardening sealant is strongly recommended. Connect the relay to a source of clean, dry, oilfree instrument air. See Instrument Air Requirements. NOTICE Caution Pressure in excess of 7 BAR (101.5 PSI) to any connection may cause damage to the relay. In any event, maximum actuator pressure should never be exceeded. Instrument Air Requirements NOTICE Caution Use of process fluids other than instrument air is not recommended. No claim is made as to the suitability of this product for use with other process fluids. NOTICE Caution Synthetic compressor lubricants in the air system at the instrument may cause the instrument to fail. There are many types of synthetic compressor lubricants. Some may not be compatible with materials used in construction of the relay. Wetting of these materials with such an oil mist or oil vapor, etc., may cause deterioration and may ultimately result in the failure of the instrument. Refer to Specifications for a list of materials. The requirements for a quality air supply can be found in the Instrument Society of America s Quality Standard for Instrument Air (ISA-S7.3). Basically this standard calls for the following: Particle Size The particle size in the air stream at the instrument shall be no larger than 3 microns. Dew Point The dew point, at line pressure, should be at least 10 C (18 F) below the minimum temperature to which any part of the instrument air system is exposed at any 16 Hardware Installation Manual, 12/2014, A5E34388399-AD

Installing/mounting 3.3 Pneumatic Connections season of the year. Under no circumstances should the dew point, at line pressure, exceed 2 C (35.6 F). Oil Content The maximum total oil or hydrocarbon content, exclusive of non-condensable, should not exceed 1 ppm under normal operating conditions. Hardware Installation Manual, 12/2014, A5E34388399-AD 17

Service and maintenance 4 4.1 Maintenance These instruments do not normally require any routine maintenance. NOTICE Caution Before disassembling the unit, make sure all air pressure to the unit is turned off. Customer/Product Support This section provides the Internet site addresses, e-mail addresses, telephone numbers, and related information for customers to access Siemens product support. When contacting Siemens for support: Please have complete product information at hand: For hardware, this information is provided on the product nameplate (part number or model number, serial number, and/or version). For most software, this information is given in the Help > About screen. If there is a problem with product operation: Is the problem intermittent or repeatable? What symptoms have been observed? What steps, configuration changes, loop modifications, etc. were performed before the problem occurred? What status messages, error messages, or LED indications are displayed? What troubleshooting steps have been performed? Is the installation environment (e.g. temperature, humidity) within the product s specified operating parameters? For software, does the PC meet or exceed the minimum requirements (e.g. processor, memory, operating system)? A copy of the product Service Instruction, User s Manual, or other technical literature should be at hand. The Siemens public Internet site (see the table) has current revisions of technical literature, in Portable Document Format, for downloading. To send an instrument to Siemens for repair, request a Return Material Authorization (RMA). NOTICE Important An instrument must be thoroughly cleaned (decontaminated) to remove any process materials, hazardous materials, or blood born pathogens prior to return for repair. Read and complete the Siemens RMA form(s). Support is available through an online Support Request service; a link is provided in the table below. Hardware Installation Manual, 12/2014, A5E34388399-AD 19

Service and maintenance 4.1 Maintenance For support and the location of your local Siemens representative, refer to the table below for the URL of the Process Instrumentation (PI) portion of the Siemens public Internet site. Once at the site, click Support in the right column and then Product Support. Next select the type of support desired: sales, technical (see the table below), documentation, or software. Online Support Request Technical Support Customer Service & Returns Public Internet Site Technical Publications in PDF http://www.siemens.com/automation/supportrequest (http://www.siemens.com/automation/supportrequest) 1-800-333-7421; 8 a.m. to 4:45 p.m. eastern time, Monday through Friday (except holidays) 1-800-365-8766 (warranty and non-warranty) http://www.usa.siemens.com/pi (http://www.usa.siemens.com\pi) Click the above link to go to the Siemens Internet site and then click Process Instrumentation. In the column to the right, click Support > Manuals. In the column to the left, select the product line (e.g. Pressure or Temperature or Controllers) to open navigation and search panes. Note: Navigation may change as the site evolves. 20 Hardware Installation Manual, 12/2014, A5E34388399-AD

Dimension drawings 5 5.1 Installation and Outline Drawings The following installation and outline drawings are used with this device: A5E34493121A Rev AB - Installation Drawing, Venting Gauge Block, PS2, FP (16152-1431) A5E34493121B Rev AB - Installation Drawing, Venting Gauge Block, PS2 (16152-1432) Hardware Installation Manual, 12/2014, A5E34388399-AD 21

Dimension drawings 5.1 Installation and Outline Drawings 22 Hardware Installation Manual, 12/2014, A5E34388399-AD

Index C Certificates, 8 Correct usage, (See improper device modifications) Customer Support, 19 D Drawings Installation and Outline, 21 H Hazardous area Laws and directives, 8 History, 5 S Scope of delivery, 5 SIPART PS2 Venting Gauge Block, 15 Specifications Weight, 15 Symbols, (Refer to warning symbols) T Test certificates, 8 W Warning symbols, 7 Warranty, 6 I Improper device modifications, 8 Installation, 15 Instrument Air Requirements, 16 K Kit Numbers, 15 M Maintenance, 19 Model Option Codes, 16 O Ordering Information, 15 P Pneumatic Connections, 16 Q Qualified personnel, 9 Hardware Installation Manual, 12/2014, A5E34388399-AD 23

Index 24 Hardware Installation Manual, 12/2014, A5E34388399-AD

For more information www.siemens.de\sipartps2 Siemens Industry, Inc. Industry Automation Division Valve Positioner Spring House, PA 19477 USA Subject to change without prior notice Order No.: A5E34388399 Lit. No.: A5E34388399-AD 12.2014 All rights reserved Printed in USA 2014 Siemens Industry, Inc. www.siemens.com/processautomation