MiniMux Multiplexer USER S GUIDE

Similar documents
MultiMux Multiplexer

INSTRUCTION MANUAL. RELAY MULTIPLEXER Model : RT-MUX 16/32. Roctest Limited All rights reserved

PT 3-PB-ST. Extract from the online catalog. Order No.:

Directory chapter 05. D-Sub Filter subminiature D connectors, 2.54 mm pitch

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

ELV12 Series. Instruction Manual

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

Using the VWDSP Interface Application Note #11

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

NOVOHALL Rotary Sensor touchless transmissiv. Series RFC4800 SSI, SPI, Incremental

SAMSUNG ELECTRO-MECHANICS CO., LTD

Sensor Mux Wiring Diagrams MultiLogger Application Note #17 Revision March 2008

LGR-5325 Specifications

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

Xitanium. LED Driver. Philips Advance. PHILIPS ADVANCE Xitanium LED Driver XITANIUM 100W 2.30A INT-S XI100C230V042FNS1. Dimensions. Features.

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Programmable Power Supply with DALI

USB-1616FS. Analog Input and Digital I/O. Specifications

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

Data Sheet for Joysticks

Preliminary. LED Driver. Xitanium SR DRIVER 150W V 1.05A SR XI150C105V157VSF1. Specifications. Enclosure. Wiring Diagram

SPST-NO SPDT DPST-NO DPDT

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

Peak/Valley Hold Unit (PVHU) User Manual V3.00

Max. Input Power (W) Input Current (Arms) / 83 <15% Dimming. Enclosure

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

LED Driver. Xitanium DRIVER. 180W A 0-10V Dimming with SimpleSet and Aux. Output XI180C125V200PSF1. Specifications. Enclosure.

Tempco Instruction Manual

LED55WPG Programmable LED Driver

OLU550P102U1U PSOV550102*

LGR-5327 Specifications

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

T M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09.

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

This data sheet is only valid in association with the IL SYS INST UM E user manual.

LED Driver. Xitanium SR 150W V 0.7A SR XI150C070V235VSF1. Specifications. Wiring Diagram. Enclosure. Input and output use lead-wires.

Xitanium. LED Driver. Philips Advance. PHILIPS ADVANCE Xitanium LED Driver. Xitanium 40W 0.70A 0-10V INT-J XI040C070V056CNJ1. Dimensions.

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

em4 Accessories Digital expansions

OPERATION MANUAL MODEL TT-LP

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

AZ420 MINIATURE GENERAL PURPOSE RELAY

Preliminary. LED Driver. Xitanium SR 75W V 0.7A SR XI075C070V118VSY1. Specifications. Enclosure. Wiring Diagram 1.50"

Using Campbell AVW2xx Vibrating Wire Interfaces MultiLogger Application Note #21

CANARY. Acquisition Solutions. What Do We Do? Software Systems. Network Management. Sensors Input. Dataloggers Measure. Communications Transfer

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Model Number Structure

Surge Protective Device

Gas Discharge Tubes GTCX36-XXXM-R10 Series

2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Preliminary Product Overview

Specifications USB-1616FS

ECC Chaining Modules

Model 7705 Control Module

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

BOX TRANSDUCER SMALL SIZED AC TRANSDUCER 90 SERIES

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Telephony Multi-Taps. 9000T-TP Series

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

American Power Design, Inc.

Model Number AC-60CD1.4APPU

Model Datalogger (Micro-6000)

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

16-Way Input 48-Way Output Card

Data Sheet for Joysticks

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Quad-Relay Delay Switch (QRDS) User Manual (v1.0)

PESDALC143T5VU Low Capacitance ESD Protector

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features:

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

Surge Protective Devices. STV100K Series. Instruction Manual

Customer P/N: UDE P/N: RUK-ZZ Description:

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Surge Protective Devices. STV100K Series. Instruction Manual

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Autodaptive Capacitor Control M 2501B

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

Xitanium. LED Driver. Philips Advance. PHILIPS ADVANCE Xitanium LED Driver XITANIUM 75W 1.05A 0-10V HCN-F XH075C105V070CNF1. Dimensions.

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

ESD4-DFN LOW CAPACITANCE TVS ARRAY PIN CONFIGURATION

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

Avtec, Inc. Lighting Systems

SSI-1016H Specifications and Operation Manual

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

Solid-state Timer H3YN

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

Transcription:

MiniMux Multiplexer USER S GUIDE Disclaimer: The following document is provided to assist users with the installation, operation and training in the use of our products. This document and our products are intended to be used by technically qualified personnel. Contained herein is information that is proprietary to Canary Systems and may not be reproduced or copied in any form, nor disclosed to outside parties by any means whether directly or indirectly, without the written consent of Canary Systems. This document is subject to change without notice and Canary Systems assumes no responsibility for errors, omissions or misinterpretation. Furthermore Canary Systems makes no warranty as to the suitability of this information and/or products for any given application or use. Copyright 1998-2015 Canary Systems, Inc. All Rights Reserved. MiniMux_UsersGuide.doc Revision D 5 Gould Road New London, NH 03257 USA Voice: (603) 526-9800 e-mail: support@canarysystems.com web: www.canarysystems.com

Table of Contents Section 1 Introduction 1.1 Overview... 3 1.2 Specifications... 4 Section 2 MiniMux Operation and Installation 2.1 Operation Details... 5 2.2 Daisy Chaining MiniMux... 5 2.3 Instrument Connection... 6 2.4 Datalogger Connection... 6 2.5 MultiLogger Configuration... 7 2.6 CR1000 Program Example... 8 2.7 Panel Mount Installation... 9 2.8 Field Enclosure Installation... 9 2.9 Lightning Protection... 9 Section 3 Troubleshooting 3.1 Troubleshooting Flowchart... 10

Section 2 MiniMux Operation and Installation 3 1.1 Overview The MiniMux expands the number of instruments that may be read by a datalogger or other measurement device in increments of 16 or 32 channels, depending on the switch setting of the MiniMux and the type of sensor being read. The MiniMux may be purchased installed in a field enclosure complete with cable glands or as a panel mount enclosure for users supplying their own field packaging. The MiniMux utilizes advanced high-reliability components such as terminal blocks from Phoenix Contact (www.phoenixcontact.com), relays from Panasonic, (http://na.industrial.panasonic.com/) and a microcontroller from Microchip Devices (www.microchip.com) to help insure years of reliable and troublefree operation. The use of low contact resistance relays means almost universal instrument support, a high degree of lightning protection and virtually infinite channel isolation. In addition, each instrument channel is equipped with tripolar surge arrestors. Shield connections are protected with bipolar surge arrestors. These spark gap devices provide resettable high-current transient protection for each channel. The Warranty is applicable for 2 years from the date of shipment. The Warranty does not cover failure by misuse or by nature including lightning, flood, or other catastrophe. Should you encounter problems with your MiniMux see the troubleshooting flowchart in Section 3.

Section 2 MiniMux Operation and Installation 4 1.2 Specifications General Power requirements: 11-16 VDC (unregulated), nominal 12 VDC Disabled current: less than 1 µa Channel activated current (2 or 4-wire): ~40 ma Control line input impedance: 100 kω Control line input levels: TTL or CMOS (5V logic) (Maximum Input voltage on any control line: 14 VDC Power input transient protection: 17.1 VDC, 1500W Transzorbs Control signal input transient protection: 5.8 VDC, 1500W Transzorbs Operating temperature: -40 to +70 C (-40 to +160 F) Lightning Protection Sparkover Voltage @ 100 V/s +/- 20% Tolerance: 75 VDC Impulse Sparkover Voltage @ 1kV/μs: 600 VDC Impulse Discharge Current 8x20μs, 10 hits (5 hits each polarity) 1 ka, 8x20us 300 hits (150 hits each polarity) 100A Impulse Withstanding Voltage, 10/700 µs 10 hits (5 times each polarity) 4kV Capacitance @ 1MHz <0.5 pf Insulation Resistance @ 100 VDC 1000 MΩ UL Rating UL497B #E179610 Control Measurements (typical)* Disabled Current: 0.1 μa (single mux) Standby Current ( channels engaged): 4 ma (single mux) Active Current (Channel 1): 40 ma (single mux) Disabled Current: 0.15 μa (two muxes daisy-chained) Standby Current ( channels engaged): 5 ma (two muxes daisy-chained) Active Current (Channel 1): 40 ma (two muxes daisy-chained) Enable Output Voltage: 4.75 VDC Relays Power: 11 ma @ 12 VDC (140 mw) Contact type: Gold-clad silver alloy Electrostatic capacitance: 3 pf On resistance: 50 mω Coil resistance: 1,028 Ω Maximum switching voltage: 125 VAC, 110 VDC Maximum switching power: 30 W (resistive load) Maximum switching current: 2 A Operate time: ~2 ms Release time: ~1 ms Initial contact bounce: ~1 ms Surge withstand (between open contacts): 1,500 V Switching life (mechanical): 100,000,000 operations Dimensions: Overall (L x W x H): 8.5 x 4.25 x 1 (216 x 108 x 25 mm) Mounting Hole Pattern (L x W): 8.0 x 3 (200 x 75 mm) Mounting Hole ID: 0.125 (3.2 mm)

Section 2 MiniMux Operation and Installation 5 2.1 Operation Details The MiniMux is controlled by a digital controller using two digital control signals. The operation of the MiniMux is simple enough so that virtually any device capable of controlling two digital TTL/CMOS type signals can be used to control the multiplexer. Generally speaking the timing diagram depicted below describes how the two digital signals are used to control the MiniMux. 10 ms Min. 50 ms Min. 50 μs Min. 50 μs Min. ENABLE CLOCK 1 2 15 16 Channel Channel 1 Channel 2 Channel 15 Channel 16 Channel In the 32 channel mode, the maximum number of pulses to advance through all the channels would be 32. 2.2 Daisy Chaining MiniMux Daisy Chaining allows for a single set of digital control signals (and single cable) to control multiple multiplexers. The number of multiplexers that may be connected is technically unlimited as the control signals are re-generated at each multiplexer. Generally, however, no more than 20 multiplexers should be connected as power losses due to lead wire resistance and control signal latencies will potentially cause problems. To utilize the Daisy Mux operation, simply connect the ENO (Enable Out) to the EN (Enable) on the next mux. The CKO (Clock Out) is connected to the CK (Clock) of the next mux. When the MiniMux reaches the maximum channel (either 16 or 32, depending on the switch configuration) and more clocks are received, the ENO becomes logic high. The CK outputs to CKO. The first mux switches to a low current standby mode. This continues until the next mux is at the maximum channel (either 16 or 32 depending on the switch configuration). To reset the entire string of multiplexers simply set EN low on the first multiplexer.

Section 2 MiniMux Operation and Installation 6 2.3 Instrument Connection The way instruments are connected to the MiniMux will vary depending on whether it is configured for 16 or 32-channel operation. Use the DIP switch on the front panel to configure the operation. Default configuration is 16-channel. The following table illustrates typical connection techniques for each of the operating modes. Mode Description Example 16 Channel (4-wire) (Default) 32 Channel (2-wire) 2.4 Datalogger Connection The MiniMux is connected to a digital controller using the screw terminals on the terminal board. Functions are described in the following table. MiniMux Terminal Description 10-Pin Souriau 1 Mux Cable (n-twisted) 2 Mux Cable (5 Twisted Pair) 1H High side of CH1 A Brown White 1L Low side of CH1 B Red White s Black 2H High side of CH2 C Orange Red 2L Low side of CH2 D Yellow Red s Black AG Instrument shield E Green White & Red Pair Drain Wire 12V Power F Blue Yellow 3 GND Ground G Purple Yellow s Black 3 EN Enable H Grey Green 3 ENO Enable Out N/A N/A Blue 3 CLK Clock J White Green s Black 3 CLKO Clock Out N/A N/A Blue s Black 3 SHIELD Cable Shield K Cable Shield Overall Shield EARTH Earth Ground tes: 1 The 10-Pin Souriau is an optional mil-spec connector available for the MiniMux Field Enclosure. 2 t suitable for Daisy Mux configurations or long cable lengths. 3 Shield drain wires for Yellow, Green and Blue pairs can be cut off.

Section 2 MiniMux Operation and Installation 7 2.5 MultiLogger Configuration To configure MultiLogger to use the MiniMux select CAN MiniMux as your multiplexer Model on the Configure Multiplexers form. Before the individual channels may be edited you must select a Gage Type of the type of gage connected. Select either 16 Channel (default) or 32 Channel to match the DIP switch settings of the MiniMux. Once the multiplexer is configured press the Edit Channels button to configure the channels. If the MiniMux is being used in Daisy Chain mode then select the same Enable and Clock for all MiniMuxes in the string. For example, multiplexer #2 (using the same configuration shown above for multiplexer #1) would be configured as follows: te the Enable and Clock settings match multiplexer #1.

Section 2 MiniMux Operation and Installation 8 2.6 CR1000 Program Example The following example illustrates how to write custom programs for the CR1000 to read instruments connected to the MiniMux. The example assumes a 16 Channel Mode MiniMux reading 16 vibrating wire gages and their respective thermistors. The MiniMux Enable is connected to C1, the Clock is connected to C8. The AVW200 to read the Vibrating Wire instruments is controlled via SDI-12 connected to C7. 'Define Public Variables Public Mux1CH(16) as Float Public Mux1TempCH(16) as Float 'Define Other Variables Dim Channel as FLOAT Dim ScratchLoc(32) as FLOAT 'Define Data Tables DataTable(FSDATA,1,-1) Sample(16,Mux1CH(),IEEE4) Sample(16,Mux1TempCH(),IEEE4) ENDTABLE 'Main Program BeginProg Scan(60,SEC,1,0) Read Instruments on Multiplexer Use C1 to Enable MiniMux PortSet(1,1) Delay(0,50,MSEC) Loop 16 times for entire MiniMux For Channel = 1 TO 16 'Use C8 to Send Clocking Pulse PulsePort(8,10000) Configure vibrating wire Gage measurement SDI12Recorder (sinbuf,7,0,"xvw400,4000,2!",1.0,0) w take vibrating wire measurements SDI12Recorder (ScratchLoc(2),7,0,"M1!",1.0,0) Convert frequency result to digits Mux1CH(Channel) = ScratchLoc(2)^2 * 0.001 Convert thermistor resistance to temperature Mux1TempCH(Channel) = 1/(.0014051 + (.0002369*Log(ScratchLoc(7))) + (.0000001019*(Log(ScratchLoc(7))^3))) - 273.2 Next 'Disable MiniMux PortSet(1,0) 'Data Output Programming CALLTABLE(FSDATA) NextScan EndProg

Section 2 MiniMux Operation and Installation 9 2.7 Panel Mount Installation The MiniMux enclosure may be installed on a vertical or horizontal surface. Holes should be drilled and tapped with machine screws used for installation. Self-tapping panel mount screws may also be used. Dimensions are shown in the illustration. ø=.188 (5mm) 8.5 (216mm) 8.0 (200mm) 4.25 (108mm) 3.00 (75mm) 2.8 Field Enclosure Installation The standard field enclosure is a fiberglass/polyester composite type; the mounting dimensions are shown below. Mounting Hole (4 places) 8.00" (203 mm) 12.5" (318 mm) 12.94" (329 mm) Earth Ground Lug 10.5" (267 mm) 2.9 Lightning Protection The MiniMux is equipped with lightning protection components. As a result, care must be exercised in installation to maximize their effectiveness. Specifically, an effective earth ground must be attached to the MiniMux or to the Field Enclosure earth ground lug for proper protection. Copper earth ground stakes and connecting wire are also available from Canary Systems.

Section 3 Troubleshooting 10 3.1 Troubleshooting Flowchart If you cannot obtain readings using the MiniMux, or the readings are unstable, then see the troubleshooting flowchart below for help in troubleshooting. If unsuccessful, contact Canary Systems by phone, fax, or email for further assistance. Contact information is found on the front cover. Start Does the MiniMux advance through the channels? Is 12V and G connected to the MiniMux? Attach 12V and G Are the switched leads connected? Connect the leads Are the Enable and Clock lines connected to the control ports? Attach Enable & Clock lines Is the wiring correct for the sensor leads? Adjust the wiring for the type of sensor used te: See the MultiSensor User s Guide or MultiLogger User s Guide for diagrams. Do the software settings for the Enable and Clock lines match the connections? Match software and digital I/O connections Do the software settings match the sensor type and wiring? Adjust the software settings Is there a source of electrical noise nearby? Remove the noise source or move MiniMux Do the circuit boards show water or other contamination? Clean the circuit boards Call Canary Systems for further assistance