Passive Infrastructure Technical Specification. Version 1 / March 14

Similar documents
Version 1.0 July LHR Airports Limited see photolibrary.heathrow.com. Managed LAN. Technical specification

Category 5e Solutions

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification

Tarleton State University. Specifications

ISO/IEC 11801: (E)

The six major components of a structured wiring system are:

UTP Cat 5e cable (200 MHz) (PVC sheath)

[0.057] 5.8 [0.23]

Cat 6 (500 MHz) UTP solid cable (PVC sheath)

TECHNICAL SPECIFICATION WIDE AREA MOBILE DATA (WAMD)

TECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5

ANSI/TIA/EIA-568-B Cabling Standard

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

Mosaic TM LCS2 Cat. 6 RJ 45 socket

ANSI/TIA/EIA-568-B Cabling Standard

Mosaic TM LCS2 Cat. 6 RJ 45 socket

UNIVERSITY OF CALICUT (Purchase Division)

Cabling Infrastructure

Appendix 1 to the R&Mfreenet Warranty Program

Siemon PON Fiber Cabling Solutions

The Cabling Partnership

Compact Module. Category 6 UTP Cabling System

9/27/04 cci Cablecom Inc. 1

[0.057] 5.8 [0.23]

CONTENT PAGE. Giganet Company Overview... Giganet Category 5e UTP System... Giganet Category 5e UTP Patch Panel... Giganet Category 5e UTP Cable...

AMP-TWIST* 6S Series SL Jack

The Quality Connection. LEONI QuickLine Class E Cabling Solution

LACCD IT Design Standards

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

Volition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.

Chapter 3 Certifying Twisted Pair Cabling

How You Can Optimize Passive Optical LAN Through Structured Cabling

The AMP NETCONNECT Category 6 Cabling System

SNAP Compact Fiber Optic Patch Panel

Contents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06

Role of Copper Cabling in Datacentres

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

SHALLOW FLOOR BOXES.

CSRJ456K. White CSC624PP CSRJ456KB CSRJ456K90

SHALLOW FLOOR BOXES. Description Applications

Cables and Connectors

Category 7A/7 Cabling Solutions P5 Voice & Outlets Product P24. Category 7A S/FTP Cable P6 Category 3 Indoor Multi Pair Cable P25

TO THE BID PACKAGE FOR COUNTY OF INYO NETWORK PROJECT. This addendum is being issued to modify portions of the Bid Package for the Project entitled:

07. har-link Interface Connectors

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

GIGANET - MANUFACTURED TO INTERNATIONAL QUALITY STANDARDS COPPER & FIBRE GIGANET FACEPLATES & ACCESSORIES SYSTEM CATALOG.

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

Pro 21/Galea/Sistena socket for LCS 6 Category 6

Document Information:

3M Telecommunications Solutions for Networks. Volition Network Solutions Product Solution Guide. for Enterprise Networks.

ANSI/TIA-568-C Cat 6A Field Test Specifications

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

121700A Paired - Category 5e DataTuff Twisted Pair Cable

Compact Module. Enhanced Category 5 UTP Cabling System

ANSI/TIA-568-C Cat 6 Field Test Specifications

Target Interface / Construction Compliance Inspection Checklist

3 Chapter Introduction. 3.2 Copper Cable

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

INTERNATIONAL STANDARD

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

A Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks

Cabling a Data Center to TIA-942 Standard

COPPER-T EXTENDER TABLE OF CONTENTS SECTION 1 - DESCRIPTION SECTION 2 - SPECIFICATIONS... SECTION 3 - INSTALLATION

NETCONNECT. Structured Cabling Solutions Guide. Asia-Pacific Region

Los Angeles Community College District Design Standards

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect

Suppliers' Information Note BT CHANNEL EXTENSION SERVICE Service Description

Copper Structured Cabling Solutions

Peter Sharp RCDD IBI Group

Business Customer Demarcation Information

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

PIONEERS OF The Structured Cabling Systems

Cat.8 Shielded Field Termination Plug Description

PANGEN SYSTEM WARRANTY. Warranty Guide

CERTIFICATION PLUS SM

The advantages of the 6-connector channel

ADJUSTABLE FLOOR BOXES

Connectix Specification Guide for Category 6 U/UTP and Optical Fibre Cabling System Architecture

2G Engine Installation

CONTENT PAGE. Giganet Company Overview... Giganet 50 Port 1U Voice Panel... Giganet Voice Converter... Giganet Voice Cabling...

The AMP NETCONNECT Category 6 Cabling System

STRUCTURED CABLING WORKS SCHEDULE 1: GROUND FLOOR ITEM DESCRIPTION QTY UNIT RATE KSH

LCS² Cat. 6A RJ45 Socket

FTTH Cabling Concept in a Korean MDU and Expansion to OSP

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs

Uniprise Structured Cabling Solutions Guide

Voice Cable & Gel Splices

TELEBLOCK CONTENTS: Descriptions Characteristics Applications Installation Product specifications Compatibilities

Total Amount Carried Forward To Bill summary Page

Ethernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B.

Powered Fiber Cable System

Area distribution boxes with connectors

The Riser as a Contract Document. Peter Sharp, RCDD

Guaranteed flexibility

AMP-TWIST* Modular Jack, UTP, Category 6A

FIBER OPTIC HARDWARE STEVE PAULOV

Transcription:

Passive Infrastructure Technical Specification Version 1 / March 14

Contents INTRODUCTION 3 SERVICE OVERVIEW 4 HIGH LEVEL DESIGN 4 OPTIONS 8 CONTACTS 12 2 HEATHROW Technical Specification

Passive Infrastructure Introduction Heathrow has been the busiest international hub airport in the world for the past decade, handling more than 60 million passengers on an annual basis. In order to successfully cater for such an extraordinary high volume of traffic, the airport operation must be based on using a robust groundwork, providing a reliable, uninterruptable service. The IT infrastructure at Heathrow has been built to meet these challenging criteria, and is being constantly upgraded to adopt the latest innovations and standards. It has proven to be well designed to handle the daily routine operation, as well as to cope with unexpected events. Now, all the Heathrow airport tenants may benefit from this powerful IT infrastructure, commonly with the airport operations teams. Modern, resilient, built for purpose - all at the fraction of the costs for which it has been put in place. The essential element of the Heathrow common infrastructure is the cabling. It s the cabling that is connecting the entire campus, spread through the miles of wiring laid in the ceilings and floors, terminating at some 120,000 ports. Using only high quality components, compliant with the industry standards, HAL provide a reliable and stable service making sure your data is safely delivered across the airport. 3

Service Overview Put simply, the Passive Infrastructure service is based on usage of network cabling to physically connect two points located at Heathrow Airport. This can be done in multiple ways, depending mainly on the distance between those two locations, and on the speed the data shall be transferred across. For short distances, cost effective horizontal copper cabling is used; for longer distances, powerful fibre optic cabling is used to prevent loss of signal. More details about each technology are described further in this document. The main opportunity for using the passive infrastructure comes when tenants have their own active network equipment hosted in the Communication Rooms located in various Heathrow airport buildings. The passive infrastructure then provides connection between such Communication Rooms and a destination port at the Customer s site, or a connection between two Communication Rooms. HIGH LEVEL DESIGN The cabling at Heathrow has been deployed systematically, with the focus on the most efficient use of the available capacity and on the simplicity of the installed wiring structures. The overall strategy and policies applied to the cabling are based on the concept of sharing the common infrastructure. In those HAL premises where common infrastructure has not been deployed, the design and delivery process will consider the specific local environment. TERMINAL 2 T2A FTNS A FTNS B T2B PCR A PCR B STORAGE LOUNGE LOUNGE STORAGE 4 HEATHROW Technical Specification

Passive Infrastructure FTNS (Fixed Telecoms Network Services), the single demarcation point for all external telecommunications providers who want to provide services at Heathrow Terminal 2. One FTNS is in T2A and another one in T2B. PCR (Primary Communications Room), main Communications rooms, one in T2A and T2B, located airside. These house core switching, routers and server applications. Physical resilience can be configured by using both PCRA & PCRB located in T2A & T2B respectively. (Secondary Communications Rooms), multiple Communications rooms located more frequently across Terminal 2. House Access Layer switching, have 10U lockable compartments and are located to provide optimal coverage for the Cat6 structured cabling layout. (Consolidation Point), can serve one or more demises, has up to 12 data ports, and is what makes the Common Infrastructure as flexible as it is. For areas where a high number of ports are required, Heathrow can flood the areas with more s. There are already links set up between the Communications Rooms and Consolidation Points This is Common Infrastructure. This is where Telco Providers etc drop their circuits (single point of entry to T2) TERMINAL 2 Core switching and routers are to reside in the PCRs in provided racks This is not allowed FTNS A FTNS B T2B TELCO LINE PCR A PCR B Access Layer switches reside in the s STORAGE LOUNGE LOUNGE STORAGE Heathrow/Airline simply run and patch the last section between the and the point in the unit where the client wants the data port s consist of multiple data points (up to 12) 5

In all terminals, the Demarcation Point is defined as any two outlets between which the Passive Infrastructure connects. The exact point of demarcation is the female outlet of the Passive Infrastructure to which a subsequent connection is made (commonly referred to as the Channel link for Cat 6 cabling). When a connection is required either between two Communications Rooms or between a Communications Room to a port destination within a Customer s demised area, it will be provided as a single service, that is to say irrespective of the number of transitions or patching points, which might be required in order to provide the service all the way through. Where the customer has a preferred supplier for the external connectivity, Heathrow will provide a fully ed infrastructure for a Telco link between the local FTNS room and the Customer s demise. This can be done via fibre optic or Cat3 cabling, depending on what type of service has been brought from the provider chosen by the Customer. The infrastructure for both of these services are already in place between the FTNS room and all rooms, all that would be required is for the final cable run to be made from the room to the customer demise. In some key locations, there are fibre optic and copper s installed preventing the requirement to cable all the way back to the. The service can be delivered into the customer s site either through copper Cat3 cabling on patch panel, installed into the customer s cabinet or on a dual/quad RJ45 network socket. Or through a fibre optic on a patch panel installed into the customer s cabinet or on a fibre optic work area outlet. Cat 3 Telco Service to customer premises Terminal 5 and 2 only CUSTOMER PREMISES TELCO PROVIDER FTNS CABINET PRESENTED ON 1 U PATCH PANEL PRESENTED ON AN RJ45 TELECOMS OUTLET DEVICE The service is run on Cat3 cabling The service is run on Cat 6 cabling Telco provider Cabling under HALs Customer Fibre Optic Service to customer premises Terminal 5 and 2 only CUSTOMER PREMISES TELCO PROVIDER FTNS CABINET PRESENTED ON 1 U PATCH PANEL PRESENTED ON A FIBRE OPTIC WORK AREA OUTLET DEVICE The service is run on Singlemode Fibre optic cabling Telco provider Cabling under HALs Customer 6 HEATHROW Technical Specification

Passive Infrastructure Where the Customer has multiple site locations across a Terminal and wants to use their own active devices, Customers can install a router or distribution device in the airline room / PCR. From there cable out from the location to the over fibre optic to their own active equipment installed in one of the cabinet spaces reserved for commercial customers and then back over the Heathrow copper cabling to the end devices. Shared infrastructure access required in single location Terminal 2 only CUSTOMER PREMISES /11U COMMERCIAL CABINET WITH CUSTOMER ACCESS DEVICE PRESENTED ON A FIBRE OPTIC WORK AREA OUTLET DEVICE FTNS/AIRLINE ROOM TELCO PROVIDER ROUTER DISTRIBUTION EQUIPMENT/ SERVERS D /11U COMMERCIAL CABINET WITH CUSTOMER ACCESS DEVICE PRESENTED ON A FIBRE OPTIC WORK AREA OUTLET DEVICE The service could be fibre optic or Cat3 The service is run on singlemode Fibre optic cabling The service is run on Cat 6 cabling Telco provider Cabling under HALs Customer Where the Customer does not wish to install horizontal copper cabling in their premises and wish to use the Heathrow s copper cabling (as it may already be in place), the Telco service can be presented into one of the commercial cabinets located within the and then the service runs to the end user over the Heathrow infrastructure. Shared infrastructure access required in single location Terminal 2 only CUSTOMER PREMISES Can be presented in to the 20U cabinet by a Male RJ45 copper Connection depending what has been purchased from Telco supplier TELCO PROVIDER FTNS /11U COMMERCIAL CABINET WITH CUSTOMER ROUTER AND EQUIPMENT PRESENTED ON A FIBRE OPTIC WORK AREA OUTLET DEVICE The service is run on Cat3 or singlemode Fibre optic cable cabling depending on Telco media deliver to customer The service is run on Cat 6 cabling Telco provider Cabling under HALs Customer 7

OPTIONS CABLING CONNECTIVITY Up to 90 meters within a building More than 90 meters within a building Between buildings Copper Fibre Copper Cabling Due to its physical characteristics, the copper-based cabling is used only within an area of a single building located at Heathrow Airport. As it can span across a single building level, it s often called horizontal cabling. The maximum length that channel link can be run is 100 meters end to end, the last 5 meters are removed at either end for patch leads. This enables connection to end devices and cross patching, plus another 10 meters for switch looms / equipment cord that are used for the connection to network devices in the commercial and HAL cabinets. This means the maximum length a permanent link can be run is 80 meters. To ensure that all deployments are kept within this standard, a patch lead at the customer end or in the / D over 5 meters will not be provided. CHANNEL C = CONNECTION PERMANENT LINK LINK FD EQP C EQUIPMENT CORD C C C C C TE PATCH CORD/ JUMPER CABLE WORK AREA CORD For an area where the location of the Consolidation Point is unknown to the Customer, a survey will be performed to determine what kind of cabling is available for the given case. For T1/3/4/5 where a port already exists and is not used, this can be patched as needed. For T2, Heathrow provided infrastructure within a Customer s own demise includes four dual network outlets per 10 square meter of accommodation. In T2 and T5 all installations have achieved a standard sufficient enough for a 25 year TrueNet warranty to be issued. In all other terminals the minimum installation standard is to achieve a 20 year Truenet warranty. Heathrow Passive infrastructure conforms to EN 50173 and EN 50174 standards to a wide variety of communication protocols. The standard installation for internal runs is UTP LSZH and UTP PVC for external runs. STP can also be requested and is used in areas that may have high interference, such as baggage sort areas. Cat3 Specifications The Cat3 cabling at Heathrow is primarily used to deliver the copper solution Telco services, between the FTNS location and an. The continuation of this service will then be run over the Horizontal cabling (Cat5e or Cat6 depending on location) from the to final destination, be it a commercial cabinet using the switch loom or a telecoms outlet at the customer s premises. The Cat3 cabling installed at Heathrow is a multi pair cable. For internal runs the CW1308 with a jacket construction of Low Smoke Zero Halogen (LZOH) is used, while the CW1128 is for the external runs with over voltage modules installed at one end of the cable run. The Cat3 cabling is presented in the FTNS on a wall frame utilizing Series II blocks (237A), so the Telco service can be connected with a jumper wire and in the / D rooms on 25 way RJ-45 ADC Krone voice patch panels (1 pair per port), which are installed in the high density patching frames (HDPF) to enable cross patching to the Horizontal cabling with a standard straight through patch leads. All of the Cat3 backbone cabling is tested on installation for continuity and installation resistance. 8 HEATHROW Technical Specification

Passive Infrastructure Cat5e Specifications Cat5e was the chosen cable to be used for the copper cabling prior the construction of T5, therefore can be found in the older buildings and Terminals. ADC Krone TrueNet UTP with the following features is currently being used for the deployment: Covered by the TrueNet System Warranty Conductor 24 AWG solid bare copper Insulation 100% polyolefin Jacket Low Smoke Zero Halogen Nominal outside diameter 5.0mm DC Resistance unbalanced 2% DC Resistance at 20 degrees C 9.38 W/100m Mutual Capacitance at 20 degrees C 5.6nF / 100m Operating Voltage (max) 300 V DC Worst Case cable skew 22 ns / 100m Nominal Velocity of propagation 67% Operating Temp Range -20º to 75ºC Installation Temp 4º to 50ºC Transportation Temp -20º to 75ºC Conforms to ISO/IEC 11801, EN50173-1 and IEC 60332-1 Cat6 Specifications Cat 6 is now the horizontal cable of choice and is used in all new building installs. Cat6 can be found in all of T5 and out buildings and in T2. ADC Krone TrueNet UTP with the following features is currently being used for the deployment: Conductor 24 AWG solid bare copper Insulation 100% polyolefin Separator 100% polyolefin Jacket Low Smoke Zero Halogen Nominal outside diameter 6.0mm DC Resistance unbalanced 2% DC Resistance at 20 degrees C 9.38 W/100m Mutual Capacitance at 20 degrees C 5.6nF / 100m Operating Voltage (max) 300 V DC Worst Case cable skew 25 ns / 100m Nominal Velocity of propagation 69% Operating Temp Range -20º to 75ºC Installation Temp 4º to 50ºC Storage Temp -20º to 75ºC ISO/IEC 11801:2002 2nd edition (ref: IEC 61156 series) ANSI/TIA/EIA 568-B.2.1 EN 50173:2002 (ref: EN 50288 series) 9

CAT5e and Cat6 presentation The horizontal presentations at the Customer premises are made with a female RJ45 connection and terminated to T-568B. The horizontal runs within an or D are terminated on one of two types of ADC Krone TrueNet patch panels: 1U 24 way TrueNet PCB UTP patch panel for Cat5e 1U 24 way Modular KM8 Patch panel for Cat6 At the Telecoms Outlet (TO) the horizontals can be presented in a number of ways, depending on the customer requirements and location. The standard presentation for Cat5e is ADC Krone category 5e LN UTP faceplate in a double or quad variant, surfaced mounted, wall mounted or installed into trunking. For Cat6, the ADC Krone UK style faceplate and adaptors are used. These are also available in a double or quad variant and asle can be installed in the same way as the Cat5e outlets. If the outlet is to be installed into an industrial area, then a metal back box and face plate is used. The other options available are for the cables to present on to another patch panel in the Customer s cabinet located in their premises, or for the outlets to be presented onto a pod system. The pod system is a metal box / pod and comes in a different number of outlet configurations, which can accept either Cat5e or Cat6 cabling and adaptors. The pod exits the floor via a grommet on a length of flexible conduit. This pod is then secured in an accessible location like under a desk or till area and can provide multiple connectivity. This solution is suitable mainly for offices as it provides the advantage of having more flexibility for the desk moves. Copper Testing All the copper horizontal cabling is tested in accordance with and to EN50173:2002 (2) standard or those agreed with ADC KRONE to maintain their warranty. The test is carried out with a Fluke DTX and the data must meet or exceed the limit value determined in EN50173-1:2002 (2). The following checks are carried out during the testing process: Wire map Length Delay Skew Insertion Loss (Attenuation) NEXT Loss pair to pair PSNEXT Loss ELFEXT Loss, pair to pair PSELFEXT Loss Structural Return loss Return loss ACR (Attenuation to cross Talk Ratio) PSACR Propagation Delay The permanent link is only tested on installation, as all cross connection patch leads are pre tested and made by the approved manufacturer. The Channel test is only carried out when a fault condition occurs. 10 HEATHROW Technical Specification

Passive Infrastructure Fibre Optic Cabling Fibre optic connections are typically used for connections for longer distances, like between Communications Rooms at different terminals or at other buildings within Heathrow. As there is currently fibre optic cabling spanning across all of the Heathrow estate, every active cabinet in, D, and FTNS has the ability to connect to each other over single mode fibre optic cabling. This is valid also for any A (Active Consolidation Point), which is a cabinet or group of cabinets that are not located in a comms room. General Characteristics Single-mode fibre 9/125 micron step index Dual window (1310/1550 nm) All fibre optic routes are designed to have a maximum loss of 4 db or less Core counts: 12, 24, 48, 96, 144 LC fibre connector is the standard All terminations are fusion spliced of pigtails onto incoming fibre cables Fibre Optic Cabling Presentation Within all the comms rooms, the fibre is presented on to an ODP (Optical Distribution Panel) with a female LC connection, while the cross patching is carried out with male LC fibre optic patch leads. The ODP is a 1U panel which can accept up to 48 LC connections. Fibre to be delivered to the Customer premises can be carried out in two different ways; either to have an ODP installed into the customers cabinet located within their demise, or to use a Fibre to the desk Fibre optic wall outlet, which works the same as a Copper TO, but with a fibre. Both of these solutions are presented with a female LC connection. Fibre Optic Cabling Testing All Fibre optic cabling is tested in accordance with and to ISO/IEC 14763-3 standard or those agreed with ADC KRONE to maintain their warranty. The test is carried out with a Fluke DTX and OTDR (Optical Time Domain Reflectometer) while the data must always meet or exceed the limit value determined in ISO/IEC 14763-3. On the installation of any new cabling, 1 core is tested before the cable is pulled off the drum to confirm the length and quality of the cable. Once the cable has been installed all terminated cores will be tested in both directions with an OTDR to confirm continuity and ensure that all connections are within the standards When a new circuit is installed to create a channel link, the circuit will be tested with a Fluke DTX to ensure that the channel link is still within and meets the required standards stated by Krone. All cross connection patch leads are pre manufactured by an approved manufacturer and tested before being installed on site. Fibre optic cross connection leads are never made on site. 11

Contacts Contact: 0208 756 8545 Email: Heathrow@sita.aero Contact Address: Compass Centre, Nelson Road, Hounslow, Middlesex, TW6 2GW Heathrow Airport Common Infrastructure Policy (CIP) and Heathrow Airport Limited reserves all of it rights and remedies in respect of the CIP including but not limited to those rights relating to scope, application and enforcement. The rights and remedies set out in the CIP are in addition to, and not exclusive of, any rights or remedies provided by law. This document and the information contained therein are confidential and remains the property of Heathrow Airport Limited. The document may not be reproduced or the contents transmitted to any third party without the express written consent of Heathrow Airport Limited. This document and information contained therein is subject to contract.