IEEE Mb/s single twisted pair Ethernet for Process Industry

Similar documents
10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs

Tutorial: Characteristics & Requirements of Physical Networks in the Process Industry

Proudly present. Ethernet to the Field (APL)

Installation & Operation Manual

5 Fieldbus Technology

Safety instructions Overvoltage protection B81-35

PROFIBUS and Integrated Safety architectures in Ex areas


Installation & Operation Manual

10 Mb/s Single Twisted Pair Ethernet Power Distribution

Refer to attachment for more details. Andreas Meyer

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital

INTRINSICALLY SAFE ACOUSTIC EMISSION TRANSDUCERS

Explosive atmospheres occur when flammable gases, mist, vapors or dust are mixed with air. This creates a risk of explosion.

E2Q4 Square Proximity Sensor

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

Safety Instructions Cerabar M PMC51, PMP51, PMP55

Safety Instructions Cerabar S PMP71, PMP75

Intrinsic Safety Control Drawing

FEATURES DESCRIPTION

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

IECEx Certificate of Conformity

Manual English. for the Devices of the MVK-MPNIO Safety Series MVK-MPNIO F DI16/8 Art. No and MVK-MPNIO F DI8/4 F DO4 Art. No.

MTL8000-2/x Series Modular I/O

New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs. Andreas Agostin Pepperl+Fuchs

Breaking the Limits of Analog Technology. Key attributes of the technology that makes FOUNDATION fieldbus suitable for process control

How to calculate an Intrinsically Safe loop approval.

Introduction to Fieldbus Foundation Physical Layer

Distributed Intrinsically Safe Fieldbus Applications

Link Segment Considerations Industrial Applications IEEE Mb/s Single Twisted Pair Ethernet Study Group. San Antonio, Texas November 2016

Dräger REGARD 7000 Control System

IECEx Certificate of Conformity

PROFIBUS. Planning Guideline

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

SMARTLINE RM76 Supplementary instructions

FLEX Ex Spring Clamp Terminal Base

Non-Incendive Fieldbus for Simplified Maintenance

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

EXPLORER. Industrial Panel PC - Flexible Modular Design

IECEx Certificate of Conformity

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

ALTERNATING RELAYS & CONTROLLERS ARM Series

General. Remote I/O A4/1.

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

Myths and Actual Practice with Industrial Data Communications and Hazardous Areas. Steve Mackay IDC Technologies

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Link Segment IEEE Mb/s Single Twisted Pair Ethernet Study Group Chris DiMinico MC Communications/Panduit

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

IECEx Certificate of Conformity

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

M E M O R A N D U M I.S.

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

PHOENIX CONTACT - 12/2007

Barriers. EB3N Discrete Input Barrier with Redundant Output

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

Operating Instructions

The High Power Trunk Alternative to FISCO and FNICO

Safety Instructions Omnigrad TRxx, TCxx, TxCxxx

Temperature and humidity module DHT11 Product Manual

Thread length (overall length) material

Capacitance level switches LS 210 LS 220

TITLE: IECEx Cybersecurity Workshop, June 2018, Weimar Report as copy of workshop presentation INTRODUCTION

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

IECEx Certificate of Conformity

DR7100 SERIES Supplementary instructions

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

Zener Barriers Bulletin 937Z

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Inductive sensor BI5-EM18-Y1X-H1141

"Power-i" = INTRINSIC SAFETY 2.0?

Grounding Monitoring Device Series 8485

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Safety instructions VEGATOR 121, 122

remote I/O future inside

PI-EX-ME-2NAM/COC-120VAC

CPU module for zone 2 Series 9442/35

Multiphase Flowmeter FlowSys TopFlow Multiphase Meter Operations Manual

PI-EX-ME-2NAM/COC-24VDC

Next steps in single-pair ecosystem - consideration of extended reach. IEEE NEA Ad hoc

About the FLEX Ex I/O Systems

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Isolating repeater IRU 420

6 Reasons to Give PROFIBUS PA Another Look

Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Continuous Dew Measurement in Explosive Area for flammable and non-flammable gases. VASTHI ENGINEERS

S900 Remote I/O System Intrinsic safety in the field ABB

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Carbon Monoxide Sensor - ModBus

Advances in NeSSI TM communications

Transcription:

IEEE 802.3 10 Mb/s single twisted pair Ethernet for Process Industry Harald Mueller, Markus Wucher, Dr. Joerg Haehniche Endress+Hauser Page 1

Purpose Scope Initiate discussion/understanding on typical topologies and installations for industrial applications in Process Automation Rationale Typical topology, length and components Environmental conditions: Non-Ex and Ex Understanding of the specific requirements on a Ethernet Phy for the Process Automation Topology and resulting link segment characteristic enables specification on the Ethernet Phy Objective The link segment and the Phy shall not preclude the ability to create intrinsically safe devices and systems Ex requirements. The link segment current, voltage, power and stored energy shall comply with IEC 60079 Support extension to 100 Mb/s. The Phy shall not preclude the ability of future transmission speed extension (100 Mb/s) Page 2

Overview Topology in Process Automation SCADA Engineering Asset Management Office Network Existing Fieldbus Installation Legend: green Std. Ethernet blue 10 SPE purple Fieldbus (non Ex) black Fieldbus (Ex) PLC Power Process Network PROFINET/ EtherNet IP Power PLC Power Power Switch Remote I/O w/ Switch Power Remote I/O`s, PROFINET/ EtherNet IP Field Switch 10 SPE 2-wire with power Power Field Switch (separate power) Field Devices 10 SPE 10 SPE 10 SPE 10 SPE Field Devices 4..20mA, HART, PA, FF, etc. Zone 0,1 Zone 0,1 Page 3

Generalized Overview of the Topology SCADA Power Engineering General purpose area @ Hazardous area Zone 2/Class1, Div. 2 Switch Trunk up to 1000m Field Switch Spur up to 200m @ Hazardous area Zone 1/Class1, Div. 1/2 @ Hazardous area Zone o/class1, Div. 1 Page 4

Power Power Switched Topology Switch Zone2/Div.2 Ex e Ex e Ex e Ex d/e Zone1/Div.1/ 2 Ex e Field Switch Ex e Ex e Field Switch Ex e Ex d/e Field Switch Ex d Zone0/Div.1 Page 5

Characteristics of the topology Components are installed within different environmental conditions hazardous areas where different handling of flammable gases, vapors and dust are attributable to normal chemical and physical processes The process automation differentiates different zones with different requirements Zone 0,1,2: The explosive characteristics of the air mixtures of gases, vapors, or dusts vary with the specific material involved. Materials have been placed in groups based on their ignition temperatures and explosion pressures The zone defines the probability of hazardous material being present in an ignitable concentration in the surrounding atmosphere. Zone 0: Area in which an explosive gas-air mixture is continuously present or present for long periods. Zone 1: Combustible or conductive dusts are present. Area in which an explosive gas-air mixture is likely to occur for short periods in normal operation. Zone 2: Area in which an explosive gas-air mixture is not likely to occur, and if it occurs it will only exist for a very short time due to an abnormal condition. Page 6

Protection types Different protection techniques are used to address the hazardous zones. Zone Ex d Flameproof (Explosion proof) Enclosure 1, 2 Ex e Increased Safety 1, 2 a Intrinsically Safe 0, 1, 2 b Intrinsically Safe 1, 2 Ex o Oil Immersion 2 Ex p Pressurized Apparatus (Purged Apparatus) 1, 2 Ex q Powder Filling (Sand Filling) 2 Ex m Encapsulation 1, 2 Ex n or Ex N Non incentive or/and normally no sparking circuits 2 Page 7

Support of standard PHY interfaces PHY MCU Interface MII => for standard devices standard MCU SGMII => for switches SPI, 3,4 pin => for low power devices and low speed MCU Page 8

Typical requirements Long distances into the field: typically 1000 meters - called as Trunk with or without power supply into the field Shorter distance in the field to the different field devices: typically 200 meters - called Spur Powering of the field devices in the field by single twisted pair including communication Field devices operating in hazardous areas are intrinsic safe limited energy in order to avoid release of sufficient electrical or thermal energy under normal or abnormal conditions Power consumption of the field device: typically 500mW to 5 W Page 9

Link segment consideration 2-wire concept supports with preferred cable: IEC61158 type A fieldbus cable with shield, other cables can be considered Power supply of the devices, low and high power devices 500mW up to 5 W Phy power consumption (less than 100mW @10Mb/s) adequate for low power field devices 10 Mbit, full-duplex via MII-Interface including auto negotiation (support for future extension of transmission speed 100 Mbit) Cable length 200 for Spur with max. 5 connectors, > 1000 m for Trunk with max. 5..10 connectors Trunk, max. 5 10 connectors Spur, max. 5 connectors Page 10

EMI requirement IEC 61326-1 and NE21 (I) Page 11

EMI requirement IEC 61326-1 and NE21 (II) Page 12

cable shield - EMI 2-wire concept supports with preferred cable: IEC61158 type A fieldbus cable with shield, other cables can be considered Cable shield option Switch Field device Ground Ground Ground Ground capacitive to ground open + - Shield + - Shield Page 13

Cable and Data rate for Process Industry Preferred cable: IEC61158 type A fieldbus cable, other cables can be considered Use for 10 Mb/s and future phase 100 Mb/s Insertion loss cable and connectors: TBD Page 14

BER Bit Error Rate for Process Industry According to actual available Fieldbus protocols Example Profinet with BER 10-9 100BASE-T1 The BER shall be less than 10-9... 10-10 Page 15

Support extension of transmission speed According to APL Group Req. Specification an extension of transmission speed should be possible APL shall support a two-phase approach. Phase 1 will provide solutions based on today available technology e.g. electronic components and intrinsically safe concepts and supports 2 and 10 Mbit/s. Phase 2 will expand the capabilities of APL based on new integrated electronic components and new intrinsically safe concepts to 100 Mbit/s which have to be developed. Page 16

Summary Take away Ethernet down to the field in Process Automation has to consider the specific requirements: length, hazardous atmosphere and more The outcome of IEEE 802.3 10 Mb/s Single Twisted Pair shall not preclude the ability to create intrinsically safe devices and systems The typical Process Automation architecture differentiate Trunk with up to 1000m down to the field and Spur with up to 200m between field device and Field Switch The IEEE 802.3 10 Mb/s Single Twisted Pair should have the ability to bring Ethernet down to the field considering the specific requirements Typical field devices are sensors and actuators that are powered via the network (power over single twisted pair 500mW 5W) The IEEE 802.3 10 Mb/s Single Twisted Pair shall not preclude IS compatible design Especially for low power field devices the power consumption of the Phy has to be small The IEEE 802.3 10 Mb/s Single Twisted Pair shall not preclude future extension of transmission speed 100 Mb/s. Version 0.0 Page 17