ImPACT. CT dosimetry and a data base for CTDI values. EFOMP Workshop at ECR Imaging Performance Assessment of CT Scanners

Similar documents
ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

Comparison of the Imaging Performance of CT Scanners, Issue 11

Optimisation of Toshiba Aquilion ONE Volume Imaging

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

INTERNATIONAL STANDARD

CT vs. VolumeScope: image quality and dose comparison

CT Protocol Review: Practical Tips for the Imaging Physicist Physicist

S. Guru Prasad, Ph.D., DABR

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

AAPM Standard of Practice: CT Protocol Review Physicist

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

RADIOLOGY AND DIAGNOSTIC IMAGING

International Journal of Innovative Research in Advanced Engineering (IJIRAE) ISSN:

CT Dose Profiler. Probe for evaluation of CT systems. CT Dose Profiler User's Manual - English - Version 6.4A. RTI article number:

8/2/2016. Measures the degradation/distortion of the acquired image (relative to an ideal image) using a quantitative figure-of-merit

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

Accessories for RaySafe Diagnostic X-ray Equipment

Fujifilm DR Solution. FDR AcSelerate. The new pinnacle in diagnostic imaging from Fujifilm ISS. CsI. Dynamic Visualization. Technology.

abc Report Wide bore CT scanner comparison report version 12 February 2005 best choice best practice nww.medical-devices.nhs.

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

ACMP 25th Annual Meeting

Kevin O Donnell Senior R&D Manager Toshiba Medical Research Institute Co-Chair, DICOM Standards Committee Past Chair, IHE Radiology Planning

The effect of automatic exposure control with inappropriate scout image on radiation dose: a chest phantom experiment with three different CT machines

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

CT issues in PET / CT scanning. ImPACT technology update no. 4

Computer-Tomography II: Image reconstruction and applications

Iterative Reconstructions: The Impact on Dose and Image Quality

GafChromic Protocol Multi-Channel Film Dosimetry + Gamma Map Analysis

Shielding factors for traditional safety glasses

GPU implementation for rapid iterative image reconstruction algorithm

CBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona

UNCOMPROMISING QUALITY

Acknowledgments and financial disclosure

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

As fl exible as your care requires

Equipment Specification

AIDR 3D Iterative Reconstruction:

A closer look at CT scanning

Biomedical Imaging. Computed Tomography. Patrícia Figueiredo IST

PCXMC 2.0 SUPPLEMENTARY PROGRAMS USER'S GUIDE

Introduction to Biomedical Imaging

Lucy Phantom MR Grid Evaluation

Retrospective Spiral Respiratory Correlated Imaging with Varian RPM

Philips SPECT/CT Systems

Lorad FFDM QC Procedures for Medical Physicist. Tao Wu, Ph.D. Hologic, Inc.

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Acknowledgments. High Performance Cone-Beam CT of Acute Traumatic Brain Injury

Evaluation of the Elekta Synergy concept for patient positioning in image guided radiotherapy

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws.

Monte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters

Deep Scatter Estimation (DSE): Accurate Real-Time Scatter Estimation for X-Ray CT using a Deep Convolutional Neural Network

Unique Features of the GE Senoclaire Tomosynthesis System. Tyler Fisher, M.S., DABR Therapy Physics, Inc.

Digital breast tomosynthesis: comparison of different methods to calculate patient doses

Michael Speiser, Ph.D.

Disclosure 7/24/2014. Validation of Monte Carlo Simulations For Medical Imaging Experimental validation and the AAPM Task Group 195 Report

The smaller, simpler, safer alternative to radioisotope irradiators. Precision s MultiRad160 is ideal for irradiating larger cell cultures and/or

Financial disclosure. Onboard imaging modality for IGRT

Cardiac Dual Energy CT: Technique

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

Computer-Tomography I: Principles, History, Technology

Symbia T Series System Specifications Answers for life.

RADIATION DOSE AND IMAGE-QUALITY ASSESSMENT IN COMPUTED TOMOGRAPHY

Z-MOTION. Universal Digital Radiographic System Z-MOTION. Control-X Medical CONTROL-X MEDICAL

Protocol. Technical evaluation of X-ray tomographic image-guided radiotherapy devices CEP10070

[PDR03] RECOMMENDED CT-SCAN PROTOCOLS

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Monte Carlo simulation of scatter field for calculation of contrast of discs in synthetic CDMAM images

Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems. Bruce Curran University of Michigan Medical Center Ann Arbor, MI

Fits you like no other

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

Whole Body X-ray CT System Supria. DICOM Conformance Statement

Dosimetry Simulations with the UF-B Series Phantoms using the PENTRAN-MP Code System

The effects of metal on size specific dose estimation (SSDE) in CT : a phantom study

RECENTLY APPROVED GE FFDM DBT TESTING PROCEDURES.

Using a local Dose Index Registry system to determine Notification Values for the MITA XR 25 (Dose Check) Standard in CT

Development and Use of Computational Anthropomorphic Phantoms for Medical Dosimetry Nina Petoussi-Henss

CT: Physics Principles & Equipment Design

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

Preparing for Part 2 of the ABR Diagnostic Physics Exam

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

Deep Scatter Estimation (DSE): Feasibility of using a Deep Convolutional Neural Network for Real-Time X-Ray Scatter Prediction in Cone-Beam CT

MEDICAL IMAGING 2nd Part Computed Tomography

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

Evaluation report. X-ray tomographic image guided radiotherapy systems CEP10071

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Spectral analysis of non-stationary CT noise

Improvement of Efficiency and Flexibility in Multi-slice Helical CT

Diagnostic quality of time-averaged ECG-gated CT data

Conflicts of Interest Nuclear Medicine and PET physics reviewer for the ACR Accreditation program

DUAL-ENERGY CT IN PROTON THERAPY

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Helical 4D CT pitch management for the Brilliance CT Big Bore in clinical practice

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

Fits you like no other

Digital Image Processing

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Transcription:

ImPACT Imaging Performance Assessment of CT Scanners A Medical Devices Agency Evaluation Group CT dosimetry and a data base for CTDI values EFOMP Workshop at ECR 2002 S. Edyvean, ImPACT St George s Hospital, London

CT scanner dose distribution higher lower 2

CT scanner dosimetry Computed Tomography Dose Index (CTDI) CTDI FDA CTDI 100 CTDI w CTDI 100 = 1 T + 50 50 D(z)dz CTDI w =1/3CTDI c +2/3CTDI p c = centre positon, p= periphery position 3

CT scanner dosimetry Monte Carlo Calculations NRPB (1991,1993) GSF (1991) WinDose 4

NRPB CT organ dose datasets NRPB SR250, 1993 23 Organ dose data sets generated using MC calculations Effective Dose Organ dose and ED expressed relative to CTDI in air n D mgy / mgy, n ED msv/ mgy Numerical phantom NRPB R248, 249, 250, SR250 5

NRPB CT organ dose datasets Relevant information from manufacturers for 27 scanner models Condensed to 13 scanner groups based on scanners with similar dosimetry characteristics Different kvs 23 Monte Carlo organ dose data sets 6

Purpose of ImPACT survey In 1996 80 scanner models with different names in use in the UK NRPB SR250 MC data sets not applicable to ~65% of scanners in UK increasing due to number of newer scanner models How to estimate patient doses on these scanners? 7

Three choices 1. Generate new MC datasets no relevant expertise difficult to acquire accurate information on ~ 80 scanner models 8

Three choices 2. Data set from an average scanner does not address differences between models 3. Use dose distribution characteristics to match new scanner models to those used in NRPB SR250 Then use appropriate MC data set Based on assumption that old and new scanners fell within similar ranges method chosen 9

Scanner Characteristics Survey Measurement based approach easy to carry out on existing and future scanners Standard protocol how to do the measurements accuracy and tolerances of set up data sheets 30 centres, 74 scanners UK + Holland,France,Spain x-ray tube x-ray slice y-axis ion chamber scanner z-axis tilt Scanner couch detectors 10

Scanner models 80 models ~ 40 groups at first by partial knowledge then refined by review of measurement data 11

CTDI air X-ray source CTDI phantom Ion chamber Perspex Phantom Detectors HVL Off-axis variation Aluminium

ImPACT survey data Separated scanners into those with NRPB SR250 MC data sets newer models without 13

Scanners with NRPB SR250 MC data sets Survey measurement data versus calculated ED Establish which combination of data gave best correlation CTDI air CTDI ph HVL 14

Scanners with NRPB SR250 MC data sets Survey measurement data versus calculated ED Establish which combination of data gave best correlation CTDI air CTDI ph HVL 15

Scanners with NRPB SR250 MC data sets Survey measurement data versus calculated ED Establish which combination of data gave best correlation with ED CTDI air CTDI ph HVL 16

CTDI data : phantom factor CTDI air CTDI ph HVL Phantom Factor = CTDI w / CTDI air Gelijns, K. Patient Dosimetry in Diagnostic Radiology, Chest Examinations and Computed Tomography, PhD Thesis, Leiden 17

ImPACT factor CTDI air CTDI ph CTDI air CTDI c,ctdi p HVL Multi-variate analysis for combination which gave best correlation ImPACT Factor ImF = a. (CTDIc / CTDIair)+ b. (CTDIp / CTDIair)+ constant 18

HVL vs normalised ED 12 10 y = 7.6119x + 0.0736 R 2 = 0.9131 8 HVL (mm) 6 4 2 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 Normalised Effective Dose ( ED / CTDI air ) (msv/mgy) 19

HVL vs normalised ED 12 10 y = 7.6119x + 0.0736 R 2 = 0.9131 8 HVL (mm) 6 4 2 0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 Normalised Effective Dose ( ED / CTDI air ) (msv/mgy) 20

Phantom factor vs normalised ED Phantom Factor (CTDI w / CTDI air ) 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 y = 0.7089x + 0.0012 R 2 = 0.9369 0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Normalised Effective Dose ( ED / CTDI air ) 21

ImF vs Effective Dose 1.6 1.4 1.2 y = 0.977x + 0.0203 R 2 = 0.977 1.0 0.8 0.6 0.4 0.2 0.0 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 Normalised Effective Dose (Abdomen) ( ED / CTDI air ) 22

Correlations for data combinations Correlation co-efficient (r^2) (r 2 ) 1 0.975 0.95 0.925 0.9 0.875 0.85 0.825 0.8 HVL CTDI CTDI HVL, CTDI HVL CTDI CDTI HVL & CTDI (PF) (ImF) head neck chest abdo pelvis 23

Newer scanner models ImF calculated Compare to ImFs for SR250 scanners Find closest match Use that MC dataset New ImF Scanner Philips AV 0.62 SR250 ImF Scanner xxx 0.60 yyy 0.75 Data Set MC 1 MC 2 24

CTDI data 25

ImPACT Factor - scanner matching 26

Organ and Effective Dose 28

Spiral scanning 29

CTDI and collimation relative CTDI 2.50 2.00 1.50 1.00 0.50 0.00 Single slice plus4 Multi-slice vol zoom 0 5 10 15 20 collimation 30

CTDI and slice width 31

Multi-slice scanners 32

ImPACT 1996-1997 survey Enabled NRPB datasets to be used for 99% of installed scanners in the UK New scanners are measured routinely by ImPACT and published CTDI in air and in phantom ImF 33

EUR16262 Quality Criteria for CT Dose Reference Levels CTDI w, DLP CTDI w =1/3CTDI c +2/3CTDI p c = centre positon, p= periphery position 34

Scanner models Name can be misleading Siemens Plus, Plus 4 Philips LX, AV Expander Filtration can change on existing scanner models name stays the same need to identify by model name & date 35

ImPACT data Survey data tried to minimise errors chambers cross checked extensive work checking consistency of data data > 10% from mean of a group looked at newer scanners use our own data checked against manufacturers data Data for 10 mm slices only used for matching look-up tables simplified need focal spot with narrow slices 36

Goal achieved ImPACT survey matching new scanners to NRPB MC datasets Additional use for phantom CTDI EUR16262 (10 mm data) Data continuously updated Need to keep aware of manufacturers changes CTDI air CTDI Px 37

Acknowledgements N. Keat, M.A. Lewis, H. Kiremidjian, Dr. S. Sassi, Dr. A.J Britten, S E Jackson (DoH) Department of Health Grant Ref RPP 26 Dr. P. Shrimpton (nrpb) Participating centres ImPACT Imaging Performance Assessment of CT Scanners A Medical Devices Agency Evaluation Group www.impactscan.org 38