Additional Device Support in PowerLogic ION Enterprise 6.0

Similar documents
Instruction Bulletin. PowerLogic File Transfer Utility Installation Guide. Introduction A1 05/2009 LaVergne, TN, USA

StruxureWare Power Monitoring Expert 8.0 Data Center Edition

PowerLogic ION Enterprise 6.0

Generator Performance Guide 7EN /2015

Compact NSX communication

PowerLogic ION7550 RTU option

The PowerLogic range. Gain energy insight and control

StruxureWare Power Monitoring 7.0

The synergy of SCADA with energy control

Compact NSX communication

PowerLogic ION Setup 3.0

Gateways & Energy Servers

PowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet

PowerLogic ION7300 Series

Firmware Revision History

StruxureWare Power Monitoring Expert for Healthcare 7.2

StruxureWare Power Monitoring Expert (PME) 8.x Fundamentals

PowerLogic ION7300 Series

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

PowerLogic ION7550 / ION7650 Hardware Lockable Meter

DOCA0069EN 10/2016. Ecoreach Online Help. Version /2016 DOCA0069EN-04.

PowerLogic TM Series E4800 Multi-Circuit Meters. Configuration Guide

How can I. Implement a cost-effective energy monitoring system for small to medium buildings using Com'X 510?

PowerLogic Active Pager Module Version 6.1

WinPM.Net 3.2 User Guide

PowerLogic ION6200 Serial Communications Protocol and ION / Modbus Register Map

E3xA, E3xB, E3xC, E3xE

PowerLogic High Density Metering System 1-Meter Enclosure

StruxureWare. Power Monitoring Expert 8.2 User Guide 7EN /2017

ULP System ULP (Universal Logic Plug) System User Guide

Therefore, before you can use the Microlog Inspector application for the first time, you must perform the following steps:

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

DOCA0093EN-00 10/2015. ULP System. ULP (Universal Logic Plug) System User Guide 10/2015 DOCA0093EN-00.

Instruction Bulletin 3080IB0801 April PowerLogic Active Pager Module Version 6.0

ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL

Small hydro power plant automation. Oswaldo Kaschny Schneider Electric Brazil CDI Power

Electrical network protection Sepam series 20 Sepam series 40 Quick start

PowerLogic TM Series EM4800 Multi-Circuit Meters. Configuration Guide

PM800 series. Applications

Instruction Bulletin. Sepam Series 20 & 40 Relays Quick Start Guide

WinPM.Net 6.0. PDF version of the Web Applications online help

PowerLogic Branch Circuit Power Meter Series. Harness industry-leading monitoring capabilities for maximum power reliability

/2009. PowerLogic ION8600. Energy and power quality meter. User Guide

Quick Start powermanager SENTRON. Software Quick Start powermanager. Introduction. Installation. Starting the project 3

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

7-1. This chapter explains how to set and use Event Log Overview Event Log Management Creating a New Event Log...

Opus Supervisor User Guide

Communication 7. What's in this Chapter? This chapter contains the following sections:

PowerLogic TM SCADA. System integrator s manual Version E1 06/2011

8-1. This chapter explains how to set and use Data Sampling.

PowerLogic ION7550 / ION7650

Dell EMC ME4 Series Storage Systems. Release Notes

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Sequence of Events Recorder

PowerLogic ION8650 Energy and power quality meter User guide

DOCA0069EN 09/2014. Ecoreach Online Help. Version /2014 DOCA0069EN-00.

PowerLogic TM Tenant Metering Solutions. Neel Sharma Schneider Electric 1

Department Administration

Sentry Power Manager (SPM): Hub and Node Feature Part Numbers SPM-Hub and SPM-Node

1. Supplied Items. 2. Connecting the DTS SKT. Input side. Input Side

ZENworks 2017 Full Disk Encryption Pre-Boot Authentication Reference. December 2016

Using LCS Help. In This Section

Scheduler Plug-In PTC Inc. All Rights Reserved.

Scheduler Plug-In Help Kepware Technologies

Web Designer for Modicon M340, Premium and Quantum

PowerLogic ION7300 Profibus DP. Serial Communications Protocol October 2006

Package Manager. Managing Cisco VXC Manager Packages CHAPTER

StruxureWare Power Monitoring Expert 8.0

Logipam. SFT2885 Programming Software for Sepam Series 80 User s Manual 01/ SEPED303004EN. Logipam

StruxureWare. Power Monitoring Expert 8.2 Hierarchy Manager Help Topics 7EN /2017

TCweb Data Logger. November 9, 2005 Rev D Tidal Engineering Corporation Page 1 of 30

DEB Setup Video. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

Generic SCADA System. User manual. Ovak Technologies

RGM180 Display Series

BCM2 Series Branch Circuit Monitors Quick Setup Guide

PEGASUS DISTRIBUTOR S GUIDE

Managing the CaseMap Admin Console User Guide

PowerLogic BCPM Functions and characteristics

Installation Guide CONTROL MICROSYSTEMS

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

MODULAR CIRCUIT MONITORING SYSTEM

Energy Management Smart Panel

Eco-POWER METER Data Collection Software KW Monitor Operation Manual

Cimetrics, Inc. B6030 BACnet/IP to Utility Meters. User Manual V.4

Client Proxy interface reference

User s Manual Type DTWG Web Server Version 1.1

Meter Insights. QR code feature Quick start guide

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

VERIS H8035 and H8036

PM Series Power Meter

Chromeleon-PA Analyzer User s Guide Dionex Corporation

C Heat Trace Controller

ZENworks 2017 Update 1 Full Disk Encryption Pre-Boot Authentication Reference. July 2017

InfraStruxure Central 6.0 Release Notes

Contents. System Properties...5

UC for Enterprise (UCE) Room Direct for Hospitality (UNIVERGE UA5200 )

based on a previously created custom model an entirely new model

PowerLogic Circuit Monitor Series 4000T Reference Manual Addendum

User Manual. Active Directory Change Tracker

Transcription:

70072-0191-00 TECHNICAL 06/2009 Additional Device Support in PowerLogic ION Enterprise 6.0 This document outlines support in ION Enterprise 6.0 for devices that are not based on ION architecture. In This Document PM Series Devices............................................ 2 CM Series Devices........................................... 5 Compact NSX Devices......................................... 8 BCPM Devices.............................................. 10 Micrologic Trip Units......................................... 12 Sepam Series Devices........................................ 14 Upgrading from Limited Edition (LE) Device Support.................. 17 Compact, ION, ION Enterprise, Modbus, Modicon, Micrologic, Power Measurement, PowerLogic, Schneider Electric and Sepam are either trademarks or registered trademarks of Schneider Electric in France, the USA and other countries. All other trademarks are property of their respective owners. Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. 2009 Schneider Electric. All rights reserved. www.powerlogic.com Additional Information Online ION Enterprise Help Your device documentation Documentation for your device configuration software ION Setup Device Configuration Guide Software Configuration Utilities ION Setup (PM Series and BCPM devices) PMCU (CM Series devices) SFT2841 (Sepam Series devices) RSU (Compact NSX devices and Micrologic Trip Units)

PM Series Devices Additional Device Support in PowerLogic ION Enterprise 6.0 PM Series Devices The following sections provide information on using PM Series devices with The supported PM Series devices are PM210, PM710, PM750, PM810, PM820, PM850 and PM870. Configuring Devices to Communicate with ION Enterprise Before you add a PM Series device in ION Enterprise, you need to configure the device using ION Setup. The PM210 is not supported in ION Setup. The following table outlines parameters that need to be set in a particular way for the device to communicate with ION Enterprise when the device is on a serial communications loop: Device Parameter Required Setting Unit ID 1 Between 1 and 247 Protocol Modbus RTU Parity None 2 1 Each address (Unit ID) must be unique for each device on a serial communications loop. 2 This is the suggested setting for an ION Enterprise system. If you set the parity to a setting other than None, ensure that all devices on the serial communications loop are set to the same parity. If you are using the PM800 series device with the optional PM8ECC card, you need to adjust the Unit ID in Management Console to match the Unit ID of comm port 1 of the PM800 series device. Configure other settings as required for your system. See the ION Setup Device Configuration Guide for more information on configuring this device using ION Setup. Trying to communicate to the device with the same communications port at the same time using two software programs (for example, configuration software and ION Enterprise) can cause communication problems. To discontinue communication between ION Enterprise and the device, right-click the device in Management Console and select Disconnect. To restart communication between ION Enterprise and the device, right-click the device in Management Console and select Connect. Page 2 2009 Schneider Electric. All rights reserved.

Additional Device Support in PowerLogic ION Enterprise 6.0 Using PM Series Devices with ION Enterprise Using PM Series Devices with ION Enterprise After you have configured the device, use Management Console to add the device to your ION Enterprise network. See the online ION Enterprise Help for more information. The following sections outline considerations when using the device with Time Synchronization For the PM Series devices, time sync requests are sent every hour. You cannot manually send time synchronization signals to these devices from For information on enabling or disabling time synchronization, contact Technical Support. Viewing Historical Data using Web Reporter The following default reports are available to generate reports on historical data using Web Reporter: Power Quality Load Profile Energy Cost Other reports can be used with the PM Series devices but may require further device configuration to be useful. For PM Series devices that support power quality features (such as voltage sag/swell detection on the PM870), disturbance monitoring needs to be set up before you can create Power Quality reports using Web Reporter. Setting Up PM Series Data Logs for Load Profile and Energy Cost Reports The PM Series devices by default do not log all the measurements required to generate Load Profile and Energy Cost reports using Web Reporter. To generate these reports, you must first use ION Setup to configure the meter to log these measurements. Use ION Setup to configure the onboard data logs as follows: Add Reactive Energy Into the Load and Real Energy Into the Load to the Billing Log. Add the log containing basic values into the Log Files for Data Log #1. Make sure the following settings are set as noted: Ensure Enable is selected. Ensure the Logging Interval Mode is set to Continuous. Configure other settings as required for your purposes. 2009 Schneider Electric. All rights reserved. Page 3

Using PM Series Devices with ION Enterprise Additional Device Support in PowerLogic ION Enterprise 6.0 ION Enterprise Priority Numbers for PM Series Events PM Series device events are mapped to ION Enterprise event log priority numbers in the following way: PM Series Device Event ION Enterprise Priority Numbers 0 0 3 64 2 128 1 200 Upgrading Device Firmware Use DLF3000 to upgrade device firmware. CAUTION Disable communication from ION Enterprise to the device before attempting to upgrade your device firmware. You could seriously damage your device if you try to upgrade while ION Enterprise is trying to communicate with the device. To discontinue communication between ION Enterprise and the device, right-click on the device in Management Console and select Disconnect. To enable communication after the upgrade is complete, right-click on the device in Management Console and select Connect. Page 4 2009 Schneider Electric. All rights reserved.

Additional Device Support in PowerLogic ION Enterprise 6.0 CM Series Devices CM Series Devices The following sections provide information on using CM Series devices with The supported CM Series devices are CM3250, CM3350, CM4000, CM4000T and CM4250. Configuring Devices to Communicate with ION Enterprise Before you add a CM Series device in ION Enterprise, you need configure the device using PowerLogic Meter Configuration Utility (PMCU). The following table outlines parameters that need to be set in a particular way for the device to communicate with ION Enterprise when the device is on a serial communications loop: Device Parameter Required Setting Unit ID 1 Between 1 and 247 Protocol Modbus RTU Parity None 2 1 Each address (Unit ID) must be unique for each device on a serial communications loop. 2 This is the suggested setting for an ION Enterprise system. If you set the parity to a setting other than None, ensure that all devices on the serial communications loop are set to the same parity. Configure other settings as required for your system. It is recommended that you use PMCU or Vista to disable Data Log 4 on CM Series devices in your ION Enterprise network. Because this Data Log logs at a very high frequency (every 5 seconds), it can impact the performance of For more information on CM Series devices, see your device documentation. For more information on using PMCU, see the PMCU documentation. Trying to communicate to the device with the same communications port at the same time using two software programs (for example, configuration software and ION Enterprise) can cause communication problems. To discontinue communication between ION Enterprise and the device, right-click the device in Management Console and select Disconnect. To restart communication between ION Enterprise and the device, right-click the device in Management Console and select Connect. 2009 Schneider Electric. All rights reserved. Page 5

Using CM Series Devices with ION Enterprise Additional Device Support in PowerLogic ION Enterprise 6.0 Configuring Input Metering on CM Series Devices With input metering, device inputs can measure values from the same location as the device or they can measure values from locations other than that of the device. If you want these inputs to appear in ION Enterprise as device independent measurements, you must create custom labels for these measurements using PMCU. These custom labels must include the @ symbol. ION Enterprise interprets labels with the @ symbol as a device independent measurements. Measurements with the default labels appear as if they are from the CM Series device and are available to the OPC Server Assistant. However, if you use custom labels to create device-independent measurements, these measurements are no longer available to the OPC Server Assistant. Using CM Series Devices with ION Enterprise After you have configured the device, use Management Console to add the device to your ION Enterprise network. See the online ION Enterprise Help for more information. The following sections outline considerations when using the device with Time Synchronization Time synchronization is enabled by default. Signals are sent to these devices once every hour and do not include DST adjustments. You cannot manually send time synchronization signals to these devices from For information on enabling or disabling time synchronization for a particular device type, contact Technical Support. ION Enterprise Priority Numbers for CM Series Events CM Series device events are mapped to ION Enterprise event log priority numbers in the following way: CM Series Device Event ION Enterprise Priority Numbers 0 0 3 64 2 128 1 200 Page 6 2009 Schneider Electric. All rights reserved.

Additional Device Support in PowerLogic ION Enterprise 6.0 Using CM Series Devices with ION Enterprise Viewing Historical Data using Web Reporter The following default reports are available to generate reports on historical data using Web Reporter: Load Profile Energy Cost Power Quality EN50160 100 ms (CM3350/CM4000/CM4000T/CM4250) Other reports can be used with these CM Series devices but may require further device configuration to be useful. For more information on the default reports, see the online ION Enterprise Help. Setting Up CM Series Data Logs for Use with Load Profile and Energy Cost Reports The CM Series devices by default do not log all the measurements required to generate Load Profile and Energy Cost reports using Web Reporter. To generate these reports, you must first use PMCU to configure the meter to log these measurements. Use PMCU to configure the onboard data logs as follows: Add Reactive Energy Into the Load and Real Energy Into the Load to the Log Template that corresponds to basic values (e.g., Basic Values). Add the log containing basic values into the Log Files for Data Log #1. Make sure the following settings are set as noted: Select Continuous logging. Ensure Enable and FIFO are selected. Configure other settings as required for your purposes. Upgrading Device Firmware Use DLF3000 to upgrade firmware. CAUTION Disable communication from ION Enterprise to the device before attempting to upgrade your device firmware. You could seriously damage your device if you try to upgrade while ION Enterprise is trying to communicate with the device. To discontinue communication between ION Enterprise and the device, right-click on the device in Management Console and select Disconnect. 2009 Schneider Electric. All rights reserved. Page 7

Compact NSX Devices Additional Device Support in PowerLogic ION Enterprise 6.0 Compact NSX Devices The following sections provide information on using Compact NSX devices with The supported devices are Compact NSX with BSCM module and Micrologic trip units type A and type E Configuring Devices to Communicate with ION Enterprise Before you add a Compact NSX device in ION Enterprise, you need configure the device using RSU. The following table outlines parameters that need to be set in a particular way on the device for the device to communicate with Device Parameter Required Setting Unit ID 1 Between 1 and 247 Parity None 2 Auto-speed sensing No 3 1 Each address (Unit ID) must be unique for each device on a serial communications loop. 2 This is the suggested setting for an ION Enterprise system. If you set the parity to a setting other than None, ensure that all devices on the serial communications loop are set to the same parity. 3 Setting this to Yes can result in significant communications problems between ION Enterprise and the device. Configure other settings as required for your system. For more information on Compact NSX devices, see your device documentation. For more information on using RSU, see the RSU documentation. Trying to communicate to the device with the same communications port at the same time using two software programs (for example, configuration software and ION Enterprise) can cause communication problems. To discontinue communication between ION Enterprise and the device, right-click the device in Management Console and select Disconnect. To restart communication between ION Enterprise and the device, right-click the device in Management Console and select Connect. Using Compact NSX Devices with ION Enterprise After you have configured the device, use Management Console to add the device to your ION Enterprise network. See the online ION Enterprise Help for more information. The following sections outline considerations when using the device with Page 8 2009 Schneider Electric. All rights reserved.

Additional Device Support in PowerLogic ION Enterprise 6.0 Using Compact NSX Devices with ION Enterprise Compact NSX Security and ION Enterprise Access When performing control actions on the Compact NSX, ION Enterprise attempts to use the device s default passwords. If these have been changed and ION Enterprise cannot gain access to the Compact NSX, the action is aborted and an error message appears. Time Synchronization Time synchronization is enabled by default. Signals are sent to these devices once every 15 minutes and include DST adjustments. You cannot manually send time synchronization signals to these devices from For information on enabling or disabling time synchronization for a particular device type, contact Technical Support. ION Enterprise Priority Numbers for Compact NSX Events Compact NSX events are mapped to ION Enterprise event log priority numbers in the following way: Compact NSX Event ION Enterprise Priority Numbers 1 64 2 128 3 200 Viewing Historical Data using Web Reporter The following default reports are available for the Compact NSX E when generating reports on historical data using Web Reporter: Load Profile Energy Cost Other reports can be used with the Compact NSX devices but may require further device configuration to be useful. For more information on the default reports, see the online ION Enterprise Help. Upgrading Device Firmware Use RSU to upgrade firmware CAUTION Disable communication from ION Enterprise to the device before attempting to upgrade your device firmware. You could seriously damage your device if you try to upgrade while ION Enterprise is trying to communicate with the device. To discontinue communication between ION Enterprise and the device, right-click the device in Management Console and select Disconnect. 2009 Schneider Electric. All rights reserved. Page 9

BCPM Devices Additional Device Support in PowerLogic ION Enterprise 6.0 BCPM Devices The following sections provide information on using Branch circuit power meters (BCPM) with Configuring Devices to Communicate with ION Enterprise Before you add a BCPM device in ION Enterprise, you need configure the device using ION Setup. The following table outlines parameters that need to be set in a particular way on the device for the device to communicate with Device Parameter Required Setting Unit ID 1 Between 1 and 247 Parity Off 1 Each address (Unit ID) must be unique for each device on a serial communications loop. Configure other settings as required for your system. For more information on Branch circuit power meters, see your device documentation. For more information on using ION Setup to configure the device, see the ION Setup Device Configuration Guide. Trying to communicate to the device with the same communications port at the same time using two software programs (for example, configuration software and ION Enterprise) can cause communication problems. To discontinue communication between ION Enterprise and the device, right-click the device in Management Console and select Disconnect. To restart communication between ION Enterprise and the device, right-click the device in Management Console and select Connect. Using BCPM Devices in ION Enterprise The following sections outline considerations when using the device with BCPM OPC Server Support in ION Enterprise OPC server support is available for the BCPM in ION Enterprise except for channel measurements (such as channel current and channel demand), which are not exported to the OPC server. Page 10 2009 Schneider Electric. All rights reserved.

Additional Device Support in PowerLogic ION Enterprise 6.0 Using BCPM Devices in ION Enterprise Adding Devices to ION Enterprise Perform basic device configuration using the appropriate device configuration utility before you add the device to your ION Enterprise network. For instructions on adding devices to your ION Enterprise network, see the online ION Enterprise Help. The BCPM and Device Licensing in ION Enterprise Device licensing for the BCPM in ION Enterprise is different from most other devices. For specific information on device licensing and the BCPM, contact your Schneider Electric sales representative. BCPM84: For the BCPM84, each pair of current sensor (CT) strips must be added as a separate device in Each pair of CT strips has a unique unit ID (the base address that you configure and the base address plus 1). The BCPM84 appears as two devices in However, each pair of CT strips on the BCPM84 counts as half a device license so when you add both pairs of CT strips, you use one device license. BCPM42: The BCPM42 is added as one device in ION Enterprise but uses half a device license. ION Enterprise Priority Numbers for BCPM Events BCPM events are mapped to ION Enterprise event log priority numbers in the following way: BCPM Event Channel and Auxiliary Input Events 64 ION Enterprise Priority Numbers Global Events 200 2009 Schneider Electric. All rights reserved. Page 11

Micrologic Trip Units Additional Device Support in PowerLogic ION Enterprise 6.0 Micrologic Trip Units The following sections provide information on using Micrologic Trip Units with The following Micrologic Trip Units are supported as stand alone devices in ION Enterprise: Micrologic Type A (2.0, 3.0, 5.0, 6.0 and 7.0), Micrologic Type H (5.0, 6.0 and 7.0) and Micrologic Type P (5.0, 6.0 and 7.0). Configuring Devices to Communicate with ION Enterprise Before you add a Micrologic Trip Unit in ION Enterprise, you need configure the device using RSU. The following table outlines parameters that need to be set in a particular way on the device for the device to communicate with Device Parameter Required Setting Unit ID 1 Between 1 and 47 2 Parity None 3 Auto Speed Sensing No 1 Each address (Unit ID) must be unique for each device on a serial communications loop. If other devices are on the same serial loop as a Micrologic device, set the non Micrologic device Unit IDs to values between 148 and 200. 2 Because a Micrologic Trip Unit is composed of multiple components with their own unit IDs, the values 50, 100 and 200 are added to the base unit ID. For example, if you set the unit ID to 5, unit IDs 55, 155 and 255 may also used, depending on the trip unit. 3 This is the suggested setting for an ION Enterprise system. If you set the parity to a setting other than None, ensure that all devices on the serial communications loop are set to the same parity. Configure other settings as required for your system. For more information on Micrologic Trip Units, see your device documentation. For more information on using RSU, see the RSU documentation. Trying to communicate to the device with the same communications port at the same time using two software programs (for example, configuration software and ION Enterprise) can cause communication problems. To discontinue communication between ION Enterprise and the device, right-click the device in Management Console and select Disconnect. To restart communication between ION Enterprise and the device, right-click the device in Management Console and select Connect. Page 12 2009 Schneider Electric. All rights reserved.

Additional Device Support in PowerLogic ION Enterprise 6.0 Using Micrologic Trip Units in ION Enterprise Using Micrologic Trip Units in ION Enterprise After you have configured the device, use Management Console to add the device to your ION Enterprise network. See the online ION Enterprise Help for more information. The following sections outline considerations when using the device with ION Enterprise. Time Synchronization Time synchronization is enabled by default. Signals are sent to these devices once every 15 minutes and do not include DST adjustments. You cannot manually send time synchronization signals to these devices from For information on enabling or disabling time synchronization, contact Technical Support. Viewing Historical Data using Web Reporter The following default reports are available for Micrologic Type H and Micrologic Type P when generating reports on historical data using Web Reporter: Load Profile Energy Cost Other reports can be used with the Micrologic Trip Unit devices but may require further device configuration to be useful. For more information on the default reports, see the online ION Enterprise Help. Upgrading Device Firmware Use RSU to upgrade device firmware. Disable communication from ION Enterprise to the device before attempting to upgrade your device firmware. You could seriously damage your device if you try to upgrade while ION Enterprise is trying to communicate with the device. To discontinue communication between ION Enterprise and the device, right-click on the device in Management Console and select Disconnect. 2009 Schneider Electric. All rights reserved. Page 13

Sepam Series Devices Additional Device Support in PowerLogic ION Enterprise 6.0 Sepam Series Devices The following sections provide information on using Sepam Series devices with The supported Sepam Series devices are: Sepam Series 10 Sepam Series 20 firmware version V0526 or later Sepam Series 40 firmware version V3.0 or later Sepam Series 80 firmware version V3.0 or later See Upgrading from Limited Edition (LE) Device Support on page 17 for information on upgrading your Sepam Series device support from Limited Edition to standard support. Configuring Devices to Communicate with ION Enterprise Before you add a Sepam Series device in ION Enterprise, you need configure the device using the appropriate version of SFT2841. The following table outlines parameters that need to be set in a particular way on the device for the device to communicate with Device Parameter Required Setting Unit ID 1 Between 1 and 247 Parity None 2 1 Each address (Unit ID) must be unique for each device on a serial communications loop. 2 This is the suggested setting for an ION Enterprise system. If you set the parity to a setting other than None, ensure that all devices on the serial communications loop are set to the same parity. Configure other settings as required for your system. For more information on Sepam Series devices, see your device documentation. For more information on using SFT2841, see the SFT2841 documentation. Trying to communicate to the device with the same communications port at the same time using two software programs (for example, configuration software and ION Enterprise) can cause communication problems. To discontinue communication between ION Enterprise and the device, right-click the device in Management Console and select Disconnect. To restart communication between ION Enterprise and the device, right-click the device in Management Console and select Connect. Page 14 2009 Schneider Electric. All rights reserved.

Additional Device Support in PowerLogic ION Enterprise 6.0 Using Sepam Series Devices in ION Enterprise Using Sepam Series Devices in ION Enterprise After you have configured the device, use Management Console to add the device to your ION Enterprise network. See the online ION Enterprise Help for more information. The following sections outline considerations when using the device with Multiple System Access If you have multiple master software communicating to the same communication port on a Sepam Series device (i.e., ION Enterprise and another mastering software), the SEPAM Data Zone register must be configured. Sepam Event Logs are designed to initiate a delete when an event is acknowledged (read) from the device. For this reason the device is designed with duplicate event logs, called Data Zones. ION Enterprise Management Console allows the device setup to choose which Data Zone to read from. If multiple devices are using the same Data Zone then events will be deleted by one master, permanently removing them from access to the other master. The Data Zone setting must be coordinated between the two software configurations to ensure that this circumstance does not occur, or data will be permanently lost. Sepam Data Zone Value System Default default 1 1 Zone 1 2 Zone 2 1 ) The default value is Zone 2 for Sepam Series devices added to The default value is appropriate in most cases. Time Synchronization To alter the time synchronization settings for the device, right click the device in Management Console and select Configure Device. Right click the blank space below Description and select Advanced Properties. For both Timesync Enabled and Timesync with DST, the default setting is System Default. This is set at a device type level (for example, all Sepam Series 20 devices), and the System Default for both of these settings is Enabled (unless you have modified the.xml file for the device type). For Timesync Enabled, select one of the following: System Default (see note above) Yes: enables time synchronization for the device. No: disables time synchronization for the device. 2009 Schneider Electric. All rights reserved. Page 15

Using Sepam Series Devices in ION Enterprise Additional Device Support in PowerLogic ION Enterprise 6.0 For Timesync with DST, select one of the following: System Default (see note above) Yes: DST is applied for that device if time synchronization is enabled. No: DST is ignored for that device if time synchronization is enabled. Waveform Triggers and Peak Demand Reset ION Enterprise Vista allows manual waveform capture and Peak Demand reset for applicable Sepam Series devices. Device Waveform Capture Current Peak Demand Reset Power Peak Demand Reset Sepam Series 10 No Yes No Sepam Series 20 Yes Yes 1 No Sepam Series 40 Yes Yes Yes Sepam Series 80 Yes Yes Yes 1 ) Sepam Series 20 model B20, B21 and B22 do not have current inputs and so cannot trigger a Current Peak Demand Reset. Viewing Historical Data using Web Reporter The following default reports are available to generate reports on historical data using Web Reporter: Report Sepam Series 10 1 Sepam Series 20 1 Sepam Series 40 1 Sepam Series 80 1 Trend Yes Yes Yes Yes Tabular Yes Yes Yes Yes Event History Yes Yes Yes Yes System Configuration Yes Yes Yes Yes Energy Period-over-Period No No Yes Yes Load Trend No No Yes Yes Energy Usage by Shift No No Yes Yes Energy Cost No No Yes Yes Power Quality No Yes 2 Yes 2 Yes 2 1 Some models in a series may not support all the reports listed. 2 Waveform report only For more information on the default reports, see the online ION Enterprise Help. Page 16 2009 Schneider Electric. All rights reserved.

Additional Device Support in PowerLogic ION Enterprise 6.0 Upgrading from Limited Edition (LE) Device Support Upgrading from Limited Edition (LE) Device Support If you installed optional, limited device drivers and standard support is now available for those devices, you can upgrade the device support. You must perform the upgrade manually; it is not done automatically when upgrading to ION Enterprise 6.0. In order to perform the upgrade, ION Enterprise Services must be stopped. The services are stopped and restarted automatically. 1. Start Management Console and click the Devices icon in the System Setup pane. 1. Select the device(s) you want to upgrade. Right click and select Upgrade LE Device. A dialog box appears notifying you that ION Enterprise services need to be stopped in order to perform the upgrade. 2. Click OK to stop ION Enterprise services and continue. The LE Device Upgrade Status dialog box appears. If the upgrade is successful, click Close. If it is unsuccessful, contact Technical Support. 2009 Schneider Electric. All rights reserved. Page 17