Application RTU560 RJ45 RJ45. Management. Switch RJ45 RJ45. Switch 560NMS34 SDSL. Data Sheet Switch 560NMS34. Port 1. Port 2. Port 3.

Similar documents
ABB 500NMD20 Switch datasheet

Switch 560NMS34 Data sheet

Switch 560NMD01 Data sheet

Switch 560NMD11 Data sheet

Switch 500NMD30 EDS500 series

Switch 500NMD01 EDS500 series

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

Bus Connection Unit 560BCU04

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

Industrial Gigabit Managed Ethernet Switch

Industrial Managed Ethernet Switch

Characteristics. Application RTU560. HMI unit 560HMR01. Data Sheet HMI unit 560HMR01

8 or 12-Port IEC Certified Industrial Managed Gigabit Switch. EHG9508 EHG9512 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

Industrial Switches Industrial Switches

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

24x10/100/1000Mbps PoE and 4 Gigabit SFP (Combo) Port L2+ Managed PoE Switch

ESW500 Series. Industrial Managed Ethernet Switches

LineRunner IS-3400 Family

8-Port EN Certified Railway IP67 WATERPROOF MANAGED Gigabit PoE SWITCH. EMG8508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

4 or 8-Port Industrial Managed Gigabit PoE Switch. EHG7504 EHG7508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

Gazelle S1010i GE NMS-manageable Industrial Switch

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

4 or 8-Port Industrial Managed Gigabit PoE Switch. EHG7504 EHG7508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

System-vision DDM. Network connection. Monitoring and Configuration interface

ies8g COMMUNICATIONS Features Intelligent 8 Port Managed Gigabit Ethernet Switch Tel: Fax:

DIN Rail RTU 540CMD01 Data sheet

JetNet 5228G / 5228G-DC

4 or 8-Port Industrial Layer-3 Managed Gigabit PoE Switch. EHG7604 EHG7608 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

Chassis-based Media Converters

Description Features CL-SW-G1812iw-150. L2 16X 10/100/1000 copper + 2X 100/ 1G SFP SLOT DD ipv6 ready

Industrial Din Rail Ethernet Switch

1Industrial Ethernet Switch

IEC /IEEE 1613 Lite L3 Hardened Managed 24-port Gigabit SFP. 10GbE Connectivity Four 10G SFP+ for connecting the switch to the core network

Industrial Switches. Industrial switches. Copper cables Fiber optic cables Ring redundancy

XSLAN+4400 XSLAN+2xxx XSLAN+1xxx XSLAN+140

EN port managed Ethernet switch with 8x10/100Base-T(X) and 2xGigabit combo ports, SFP socket

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

ProCurve Switch 2500 Series

Preface. Managed Media Converter Chassis System

S7055xM / S7075xM Web Smart Managed 5-Port / 7-Port 10/100 Fast Ethernet Switch w/vlan Support Installation Guide

RTU560 Connections and Settings DIN Rail RTU 560CIG10

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

SWP-0208G, 8+2SFP. 8-Port Gigabit Web Smart Switch. User s Manual

Product features. Applications

HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch

500NMD Ethernet DSL switches DIN rail wide area networking

16- or 24-port Managed Switching Hubs

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

Gigabit Ethernet Industrial Switch 10 Port with Ring- Redundancy and PoE

1Industrial Ethernet Switch

Operation. RTU500 series Connection and Settings Switch 500NMD02

Spotlight Versatile Connectivity Modularized Ethernet Switch of 24-port 10/100BASE-TX/FX/BX and 4-port Gigabit-TX/SX/LX/BX/SFP

Quick Start Guide. Physical Description. The Port Status LEDs

Operation. RTU500 series Connection and Settings Switch 560NMD11

Designed, built, and tested for troublefree operation in extreme conditions

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

Save installation time and money with PoE

ProCurve Switch 2600 Series

EX Lite L3 Hardened Managed 24-port Gigabit and 4-port 1G/10G SFP+ Ethernet Switch SFP

Gigabit Ethernet Industrial Switch 10 Port with Railway and Power Substation Certification

L Port 10/100/1000T PoE + 2-Port Gigabit SFP + Managed Switch

JSH2402GBM. Introduction. Main Features Combo Port Mixed Giga Ethernet SNMP Switch. Picture for reference

Gigabit Ethernet 10 port Industrial Switch with Ring redundancy

Gigabit Ethernet Micro Switch 6 Port PoE

Gazelle S1003i Series L2 Manageable Industrial Switch/Serial Device Server

JetNet 5428Gv2. Features. Industrial 24FE+4G Gigabit Managed Ethernet Switch INDUSTRIAL ETHERNET RACKMOUNT SWITCH

Binary output and supervision 520CSD01 Data sheet

HYPERION Ports - Managed Industrial Ethernet Switch 2x 100M/1000M/2.5G SFP 24x 10M/100M/1G RJ45 PoE PoE++ Environmental limits.

Features and Benefits. Certifications

ABB 520BID01 Binary Input datasheet

8 to 14 ports 10/100Base-TX with up to 2-port 100Base-FX or Gigabit Hardened Managed Ethernet Switches. Overview

IES-P3073GC Series. Industrial IEC port managed Ethernet switch with 7x10/100Base-T(X) and 3xGigabit combo ports, SFP socket.

16-Port Industrial Gigabit Web Smart DIN-Rail Switch TI-G160WS (v1.0r)

CES2000 Series Industrial Carrier Ethernet Switches

JetNet 6528Gf. Features. Industrial 28G Full Gigabit Managed Ethernet Switch INDUSTRIAL ETHERNET RACKMOUNT SWITCH

24 Gigabit Fiber Copper PoE and Stacking Switch Series. Network Transmission Products 24 Gigabit Fiber Copper PoE and Stacking Switch Series.

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

1Industrial Ethernet Switch

Best Connectivity. 5-Port 10/100Mbps Desktop Switch with 4-Port PoE

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

Expert Line Managed Industrial Switch with M-Ring Function 6x 10/100/1000 Base-TX, 2x 10/100/1000Base-T (100/1000 Base-X SFP Ports)

Analog output 520AOD01 Data sheet

ies10gf Features Intelligent 10 Port Managed Gigabit Ethernet Switch IEC61850, IEEE1613 Compliant

Industrial and Industrial Hardened Managed PLUS non-poe and PoE switch range

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

Media Converters & Chassis

Features and Benefits. Certifications

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

CHIRON-4E1. E1 over Ethernet Multiplexer (TDM over IP)

ies10g Features Intelligent 10 Port Managed Gigabit Ethernet Switch Tel: Fax:

ExtremeSwitching Industrial Ethernet Switches

PT-7728 Series. IEC G-port Gigabit modular managed Ethernet switch. Introduction PT-7728

ExtremeSwitching Industrial Ethernet Switches

6GK6050-0MM Transmission rate. Interfaces

Gigabit Ethernet Micro Switch Twisted Pair Uplink PoE

ISO 9001:2000 Certified Company

Cisco SGE Port Gigabit Switch Cisco Small Business Managed Switches

Transcription:

Switch 560NMS34 Application The RTU component 560NMS34 is a managed plug and play Layer2-switch providing four Fast auto-negotiating RJ45-ports with auto MDI/X (Automatic Crossover Detection and Correction) and one 2-wire SDSL-port for use with private copper cables. It can be used with rack types 560MPR01, 560 MPR03, 23TP21/22, 560SFR02 and 23ET23/24. The switch is intended for distributing within a station through the RJ45-ports. The SDSL port can be used for interconnecting stations with a maximum distance of 20 km (copper cable with diameter of 0.8 mm). The switch is able to provide redundant topologies by the (Rapid) Spanning Tree Protocol. For documentation purposes, the ports are labeled from 1 to 4. The SDSL port is connected through the backplane. There is no specific uplink port. All ports are equal in function. Link and speed status of each and the SDSL port are displayed by status indicators (refer to Connectors and Indicators). The switch learns addresses by analyzing received frames and stores them in a lookuptable (max. 2048 entries), which is used to forward frames only to the correct port. If it is broad- or multicast or if the target address is not found in the lookup-table, a received frame is forwarded to all ports except the receiving one. If an entry in the lookup-table is not refreshed by an incoming frame with the specific source address, it is aged out within a maximum of 304 seconds (by default, value is configurable). Regarding IEEE 802.1Q VLAN frames, the switch can be configured to VLAN or transparent mode. In transparent mode the switch will never change any frame or TAG of a frame; in VLAN mode it can be configured to support several applications like trunk or access ports. Quality-of-Service is supported by the switch if an IEEE 802.1p compliant frame format is used. The switch can separate frames into up to four queues, which can be configured to priority based or weighted-fair queuing. The 560NMS34 uses a power supply voltage of 5 V that can be set to the internal RTU supply or external supply via a Jumper. The component itself, the ports as well as the SDSL connection are hot-plug capable. Port 1 Port 2 Port 3 Port 4 RJ45 RJ45 RJ45 RJ45 Transformer Transformer Transformer Transformer Switch SDSL Management Alarm Logic Bus / Power Connection Fig. 1: Block diagram of 560NMS34 Doc.-No.: 1KGT 150 755 V001 1 1

Connectors & Indicators The 560NMS34 switch consists of four equal RJ45 ports, one SDSL transceiver and a RS-232 interface for configuration and tunneling of serial data. Each RJ45 port can be connected with a Cat. 3 (for 10 Mbps) or Cat. 5 (for 100 Mbps) cable with a maximum length of 100 meters. The cable should only be used for inhouse connections. Since Auto MDI/X is supported by the 560NMS34 switch for the RJ45 ports, there is no need for crossover cables. The SDSL interface can be connected to 2-wire customer-owned copper lines. The maximum bridgeable distance is 20 km for 0,8 diameter copper cable with a transmission rate of 192 kbps. Depending on the distance, the transmission rate can be configured to up to 11 Mbps. The status of any switch port can be signalized by two LED indicators, which are located in each lower and upper RJ45. A green Link LED (labeled L) indicates an active connection with the states described below: Off No Connection On Connection Established (Link) Flashing Activity (Transmission or Reception of Frames) A yellow Speed LED (labeled S) indicates a 100 Mbps connection with the following states: Off On Speed of 10 Mbps Speed of 100 Mbps The state of the DSL interface can be monitored through the green LEDs labeled A1 (Activity) and L1 (Link). States of L1: Off On States for A1: No DSL connection DSL link established Off No DSL connection Flashing DSL activity (Transmission or Reception of Frames). DSL connection negotiation if L1 is off Detected errors are signalized by a red Error LED (labeled ERR) together with an Alarm condition. The alarm condition can also be signalized by an isolated alarm relay, which can be deactivated by a jumper. The conditions that lead to an alarm state can be configured. Topology The 560NMS34 provides a total of five ports for use with end devices, switches, bridges, hubs, routers or other 560NMS24, 560NMS34 or 560NMD01 using the DSL port. Star, ring or line topologies can easily be built by this family of switches. Redundant topologies are automatically detected and handled by the Rapid Spanning Tree Protocol (RSTP). This is fully backward compatible with the wide-spread Spanning Tree Protocol (STP). SDSL 560NMS34 560NMS34 Switch Device SDSL 560NMS34 560NMS34 Fig. 2: Typical topology for use with 560NMS34 Doc.-No.: 1KGT 150 755 V001 1 2

Management and Configuration Management and Configuration of the 560NMS34 can be done by Telnet, SNMP or Web-interface. All methods can be used to either read or write parameters of the device. By default, the IP address for the configuration of a 560NMS34 switch is 10.0.0.2 with a subnet mask of 255.0.0.0 and a gateway of 10.0.0.1. The SNMP strings are public for read-only access and private for read-write operations. Any 560NMS34 can be reset to this state by a hardware jumper. Telnet connections for configuration are accepted through any port. All ports are administratively up in default state. Ports All ports of the device can be disabled or enabled by configuration. Furthermore, the speed and duplex of any port can be set according to its capabilities. This is 10 or 100 Mbps, Full or Half duplex for the ports and 192 kbps up to 11 Mbps in steps of 8 kbps for the SDSL port. It is also possible to use an auto-detect setting. For the SDSL port it is recommended to set the 560NMS34 device closer to the control center to a fixed speed setting, while setting the communication partner at the RTU side to auto-detect. Ports connected to a 560CMU0X should be configured with auto detect. All ports are equipped with frame counters readable by the management software. Redundancy Support The redundancy protocols Spanning Tree Protocol (STP) and Rapid Spanning Tree Protocol (RSTP) are fully supported. Without configuration RSTP is enabled for all ports. Switching from RSTP to STP is done automatically to ensure the compatibility to existing STP installations. For every port, the (R)STP parameters can be configured separately. This includes port priority for root bridge control as well as point-to-point and edge connection settings. A global bridge priority is also settable. Authentication Access to the telnet interface of the 560NMS34 is controlled by a two-level password protection. The first level enables the user to access parameters in read-only mode and has to be entered as soon as a connection is established. To read and write parameters, the device has to be put in a configuration mode that requires an additional password. Any password can be disabled. Some security sensitive information, such as the configuration file, may not be available in read-only mode. Alerts, Notifications and Logging The 560NMS34 provides Syslog and SNMP capabilities to send alerts and notifications to one or more predefined destinations. There is also a relay for configurable out-of-band alerts. For each Syslog server entry a severity can be entered to filter outgoing messages. A system log stores critical messages. The log can be accessed by Telnet and implements a timestamp either by uptime, or date and time if a time server is configured. For Syslog and local logging, a SNTP time server can be used to synchronize clocks and to enable the generation of date and time timestamps instead of uptime related messages. Doc.-No.: 1KGT 150 755 V001 1 3

Technical Data Power Operating Voltages 5 VDC ± 10% Power Consumption typ. 4.50 W, max. 7.00 W (All RJ45 and DSL port active) Alarm Status Indicator Relais Contact Red LED, label: ERR Isolated Change Over Contact Relais max. switching Voltage / Current DC 60 VDC / 0,5 A AC 250 VAC / 0,24 A Mechanical Layout Printed circuit board 3HE, Euro-card (160 x 100 mm) Front panel Weight Connection Type Power / Alarm Connector Environment 4R, 1 slot (20 mm) approx. 180 g Indirect, 48 pole DIN 41612 Type F Operating Temperature -25...70 C rel. Humidity 5 95% (non-condensing) Electromagnetic Compatibility Radio Interference IEC 55011 Power Supply Voltage Class B Field Strength Class B Electrostatic Discharge IEC 61000-4-2 8 kv Air, 6 kv Contact Criteria A Electromagnetic Field Immunity IEC 61000-4-2 80 MHz to 3 GHz Criteria A Surge & Burst Immunity IEC 61000-4-3 and -4 Surge 4 kv Criteria A Burst 4 kv Criteria A Conducted Disturbances Immunity IEC 61000-4-6 10 V, 0.15 MHz to 80 MHz, 80% AM 1 khz Criteria A Mains Frequency Immunity IEC 61000-4-16 300 V Criteria A Oscillatory Wave Immunity IEC 61000-4-18 2.5 kv Criteria A 4 Doc.-No.: 1KGT 150 755 V001 1

Connectors Status Indicators 4 x RJ-45 Speed (10/100 Mbps): Amber LED Link/Activity: Green LED Cable Type (RJ-45) EIA/TIA Category 3 or ISO/IEC Class C cable or better for 10 Mbps EIA/TIA Category 5 or ISO/IEC Class D cable or better for 100 Mbps Max. Cable Length 100 m for RJ45, for optical connection refer to SFP Module Data Switching Flow Control Max. Frame size Quality of Service Full Duplex Flow Control according to IEEE 802.3-2005 An. 31B and IEEE 802.3x-1997 Half Duplex Back Pressure 1552 Bytes IEEE 802.1p Tag based Priority MAC Lookup Table Max. 2048 entries Max. 304 s hold time Switching Mode Store and Forward Protocol Fast- according to IEEE 802.3-2005 Cl. 25 and IEEE 802.3u-1995 according to IEEE 802.3-2005 Cl. 14 Auto-Negotiation (NWAY) according to IEEE 802.3-2005 Cl. 28 Auto-Crossover (Auto MDI/X) Digital Subscriber Line Connectors 1 x through backplane Protocol ETSI SDSL (ETSI TS 101 524 V 1.2.1) ETSI SDSL.bis (ETSI TS 101 524 V 1.2.2) ITU G.shdsl (ITU-T G.991.2) ITU G.shdsl.bis (ITU-T G.991.2 2004) ITU G.hs (ITU-T G.994.1) IEEE EFM (IEEE 802.3) Doc.-No.: 1KGT 150 755 V001 1 5

Supported Protocols Spanning Tree IEEE 802.1D-2004 Ordering Information 560NMS34 R0001 1KHW023538R0001 Class of Service IEEE 802.1p VLAN Tagging IEEE 802.1q IP ARP ICMP UDP TCP TFTP CIDR Telnet SNTP SNMP SNMP MIB-II Syslog RFC-791 RFC-826 RFC-792 RFC-768 RFC-793 RFC-783 RFC-1519 RFC-854 RFC-2030 RFC-1098 RFC-1213 RFC-3164 Doc.-No.: 1KGT 150 755 V001 1 6

Doc.-No.: 1KGT 150 755 V001 1 7

Note: We reserve the right to make technical changes or modify the contents of this document without prior notice With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2012 ABB All rights reserved 8 Doc.-No.: 1KGT 150 755 V001 1