HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Similar documents
HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006

COBRE Scan Information

SIEMENS MAGNETOM Avanto syngo MR B15

SIEMENS MAGNETOM Avanto syngo MR B15

SIEMENS MAGNETOM Verio syngo MR B17

SIEMENS MAGNETOM Verio syngo MR B15V

SIEMENS MAGNETOM Skyra syngo MR D13

SIEMENS MAGNETOM TrioTim syngo MR B17

SOP: Brain MRI Inital version Gorm Greisen. CONTENT 1.0 Timing of Brain MRI Informed consent...1

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

Siemens AG, Healthcare Sector. syngo MR D13 0. Supplement - Parameters and image text 0.

SIEMENS MAGNETOM Symphony syngo MR A30

Philips MRI Protocol Dump Created on Comment Software Stream

MRI Physics II: Gradients, Imaging

ADNI, ADNI_QH, SURVEY. Geometry. connection

Diffusion MRI Acquisition. Karla Miller FMRIB Centre, University of Oxford

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

(a Scrhon5 R2iwd b. P)jc%z 5. ivcr3. 1. I. ZOms Xn,s. 1E IDrAS boms. EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 8 Solutions

Module 4. K-Space Symmetry. Review. K-Space Review. K-Space Symmetry. Partial or Fractional Echo. Half or Partial Fourier HASTE

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

A Virtual MR Scanner for Education

MR Advance Techniques. Vascular Imaging. Class III

Scan Acceleration with Rapid Gradient-Echo

Orthopedic MRI Protocols. Philips Panorama HFO

Applications Guide for Interleaved

New Technology Allows Multiple Image Contrasts in a Single Scan

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

ADNI GO - ADNI 2 Human7 (9) 38:30.1

Fast Imaging UCLA. Class Business. Class Business. Daniel B. Ennis, Ph.D. Magnetic Resonance Research Labs. Tuesday (3/7) from 6-9pm HW #1 HW #2

MRI image formation 8/3/2016. Disclosure. Outlines. Chen Lin, PhD DABR 3. Indiana University School of Medicine and Indiana University Health

Role of Parallel Imaging in High Field Functional MRI

MRI. When to use What sequences. Outline 2012/09/19. Sequence: Definition. Basic Principles: Step 2. Basic Principles: Step 1. Govind Chavhan, MD

Functional MRI. Jerry Allison, Ph. D. Medical College of Georgia

M R I Physics Course

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Midterm Review

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Supplementary methods

Following on from the two previous chapters, which considered the model of the

Page 1 of 9. Protocol: adult_other_adni3basichumanprotocol25x_ _ _1. 3 Plane Localizer. 3 Plane Localizer PATIENT POSITION

Exam 8N080 - Introduction MRI

Fmri Spatial Processing

Lucy Phantom MR Grid Evaluation

Basic fmri Design and Analysis. Preprocessing

Field Maps. 1 Field Map Acquisition. John Pauly. October 5, 2005

Head motion in diffusion MRI

MR-Encephalography (MREG)

surface Image reconstruction: 2D Fourier Transform

SPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing

Dynamic Contrast enhanced MRA

Parallel Imaging. Marcin.

GE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.

Single Breath-hold Abdominal T 1 Mapping using 3-D Cartesian Sampling and Spatiotemporally Constrained Reconstruction

EPI Data Are Acquired Serially. EPI Data Are Acquired Serially 10/23/2011. Functional Connectivity Preprocessing. fmri Preprocessing

Functional MRI in Clinical Research and Practice Preprocessing

ACQUIRING AND PROCESSING SUSCEPTIBILITY WEIGHTED IMAGING (SWI) DATA ON GE 3.0T

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

SPM8 for Basic and Clinical Investigators. Preprocessing

syngo MR E11 Operator Manual Ortho Answers for life.

Correction for EPI Distortions Using Multi-Echo Gradient-Echo Imaging

Accelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing

Magnetic Resonance Angiography

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006

Fast Imaging Trajectories: Non-Cartesian Sampling (1)

Release Notes. Multi-Band EPI C2P. Release HCP_v1 10 February 2014

An Introduction to Image Reconstruction, Processing, and their Effects in FMRI

MRI Image Quality Assessment

MB-EPI PCASL. Release Notes for Version February 2015

XI Signal-to-Noise (SNR)

MRI Imaging Options. Frank R. Korosec, Ph.D. Departments of Radiology and Medical Physics University of Wisconsin Madison

Imaging Notes, Part IV

3-D Gradient Shimming

Motion Artifacts and Suppression in MRI At a Glance

Functional MRI data preprocessing. Cyril Pernet, PhD

Sampling, Ordering, Interleaving

Compressed Sensing for Rapid MR Imaging

FMRI Pre-Processing and Model- Based Statistics

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Table of Contents. IntroLab < SPMLabs < Dynevor TWiki

Sources of Distortion in Functional MRI Data

University of Cape Town

Qualitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs

Outline: Contrast-enhanced MRA

Breast MRI Accreditation Program Clinical Image Quality Guide

Removal of EPI Nyquist Ghost Artifacts With Two- Dimensional Phase Correction

Controlled Aliasing in Parallel Imaging Results in Higher Acceleration (CAIPIRINHA)

TOPICS 2/5/2006 8:17 PM. 2D Acquisition 3D Acquisition

Sampling, Ordering, Interleaving

Abbie M. Diak, PhD Loyola University Medical Center Dept. of Radiation Oncology

Analysis of Functional MRI Timeseries Data Using Signal Processing Techniques

2D spatially selective excitation pulse design and the artifact evaluation

Blipped-Controlled Aliasing in Parallel Imaging for Simultaneous Multislice Echo Planar Imaging With Reduced g-factor Penalty

The SIMRI project A versatile and interactive MRI simulator *

Gradient-Echo. Spin-Echo. Echo planar. Assessment of Regional Function Assessment of Global. Parallel Imaging. Function. Steady State Imaging

Partial k-space Reconstruction

T 1 MAPPING FOR DCE-MRI

Improved Spatial Localization in 3D MRSI with a Sequence Combining PSF-Choice, EPSI and a Resolution Enhancement Algorithm

Partial k-space Recconstruction

QIBA Profile: Magnetic Resonance Elastography of the Liver

Transcription:

MIT OpenCourseWare http://ocw.mit.edu HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.

HST.583: Functional Magnetic Resonance Imaging: Data Acquisition and Analysis, Fall 2008 Harvard-MIT Division of Health Sciences and Technology Course Director: Dr. Randy Gollub. 2. T, T2 and T2* Measurements Background To calculate T values of the tissue we will be using an inversion recovery turbo spin echo sequence. We will be sampling the magnetization as a function of the inversion time (TI). The observed signal intensity is given by the following equation: S(t) [ 2exp( TI /T)] () To obtain the transverse relaxation time, T2, values in the brain a series of spin echo images will be acquired by stepping through a range of TEs. The image intensity is given by the following equation: S(t) exp( TE /T 2) (2) T2star (T2*) is the time constant that describes the decay of the transverse magnetization including local magnetic field inhomogeneities. T2* is an important relaxation time for functional studies because it is related to the amount of deoxygenated hemoglobin present in the brain. To determine the T2* values in gray, white matter and CSF, we will be using a gradient echo sequence and the signal is described by: S(t) exp( TE / T 2*) (3)

Experiments In this exercise we will acquire and evaluate human data in order to characterize T, T2 and T2* values in brain tissue compartments. Various sequences will be used with the imaging parameters manipulated so that they provide the appropriate contrast weightings. T measurements Acqusition: Total scan time: 5m 38sec A. Inversion Recovery Turbo Spin Echo (tse_ir) sequence with TR=3000ms, FOV=240x240, matrix=96x28, repeated for multiple inversion times TI=200, 300, 400, 500, 600, 700, 800, 000, 300, 500, 700, 2000, 2200 ms.. Load all the images on the viewer. 2. Draw ROIs in gray matter areas. 3. Record the mean signal values in Table for each inversion time and ROI. 4. Repeat steps -3 for regions of white matter and CSF. Lab Question 6 : Draw the measured signal as a function of inversion time for each of the tissue compartments. Calculate the T for gray, white matter and CSF by fitting Eq. () to your data. Hint: you will need to use a nonlinear fitting function such as nlinfit in matlab to accomplish this. T2 measurements Acqusition: Total scan time: 9m 42sec B. SE sequence with TR=4000ms, FOV=220x220, matrix=92x92, 8 echo times in a range between 4.3ms and 4.4ms and inter-echo spacing 4.3 ms. 5. Load all the images on the viewer. 6. Draw ROIs in gray matter areas. 7. Record the mean signal values in Table 2 for each echo time and ROI. 8. Repeat steps -3 for regions of white matter and CSF. Lab Question 7 : Draw the measured signal as a function of echo time for each of the tissue compartments. Calculate the T2 for gray, white matter and CSF by fitting Eq. (2) to your data. T2* measurements Acqusition: Total scan time: sec C. 2D FLASH sequence with TR=00msec, FOV=256x256, matrix=28x28, and multi contrast with echo times TE=6, 0, 5, 20, 30, 50, 70, 80 msec. 9. Load all the images on the viewer.

0. Draw ROIs in gray matter areas.. Record the mean signal values in Table 3 for each echo time and ROI. 2. Repeat steps -3 for regions of white matter and CSF. Lab Question 8 : Draw the measured signal as a function of echo time for each of the tissue compartments. Calculate the T2* of gray and white matter and CSF by fitting Eq. (3) to your data. Lab Question 9 : According to your measurements how do T2 and T2* compare for the same tissue compartment? Did you expect these findings? Explain why. Table T Measurements TI (ms) Gray White CSF Matter Matter 200 300 400 500 600 700 800 000 300 500 700 2000 2200

Table 2 T2 Measurements TE (ms) Gray White CSF Matter Matter 4.3 28.6 42.9 57.2 7.5 85.8 00. 4.4 Table 3 T2* Measurements TE (ms) Gray White CSF Matter Matter 6 0 5 20 30 50 70 80

3. Distortion in EPI due to B0 Inhomogeneity Background The echo-planar image (EPI) is distorted due to local field gradients present in the head during imaging. Since the acquisition of k-space data is very asymmetric in EPI, with the readout direction points (kx) collected quickly and the phase encode steps (ky) relatively slowly, the distortion is essentially entirely in the y direction (phase encode direction). The relative distortion between the two directions can be estimated from the relative speed of the acquisition. In kx, at a typical readout BW (say 2.2kHz/pixel or 40kHz in frequency across the 64 pixel image), the dwell time (time between kx samples) is 7.μs. The ky sampling rate is slower because of the zig-zag trajectory, and is about 64 times slower. This gives a sampling spacing of 64 * 7.μs = 0.45ms. We call this.the "echospacing", (esp), of the sequence, the time between gradient echos (acquisition of the kx=0 point). The effective "bandwidth" in the phase encode direction is therefore across the esp image or /64*esp = 34.7Hz/pixel. Therefore a B0 shift which induces a 34.7Hz frequency shift will induce a shift in this region of pixel. The frequency shifts in the "bad susceptibility" regions of the brain are easily in the 00Hz range. Therefore, the principle metric of how distorted the EPI sequence will be is its effective echo-spacing. For conventional echo-planar imaging, this is basically limited by the gradient slew rate and amplitude. Using parallel acceleration such as SENSE or GRAPPA effectively decreases the esp by a factor of the acceleration factor, (i.e. 2 or 3 fold).

Experiments In this lab we will acquire images with different effective esp and compare the distortion in the brain. Acquisition : ) epi_esp730: voxel size = 3. x 3. x 3., Matrix size = 64x64, BW=502Hz/px, ESP=0.73ms, effective esp =0.73ms 2) epi_esp460: voxel size = 3. x 3. x 3., Matrix size = 64x64, BW=2520Hz/px, ESP=0.46ms, effective esp =0.46ms 3) epi_esp480_grappa: voxel size = 3. x 3. x 3., Matrix size = 64x64, BW=2520Hz/px, ESP=0.48ms, effective esp =0.46ms Lab Question 0: Estimate the distortion in frontal lobes by measuring distance on the scanner to some reference feature. Plot the distortion in mm as a function of effective esp.

SIEMENS MAGNETOM TrioTim syngo MR B5 \\USER\INVESTIGATORS\HST_583\Physics2\tse_IR TA: 0:26 PAT: Voxel size:.9.9 5.0 mm Rel. SNR:.00 SIEMENS: tse Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slice group Slices Dist. factor 50 % Position R0.7 A0.8 H2.2 T > C-0.3 Phase enc. dir. 90.00 deg Phase oversampling 0 % FoV read 240 mm FoV phase 75.0 % Slice thickness 5.0 mm TR 3000 ms TE 2 ms Averages Concatenations Filter Coil elements HEA;HEP Contrast MTC Magn. preparation TI Freeze suppressed tissue Flip angle Fat suppr. Fat sat. mode Water suppr. Restore magn. Averaging mode Reconstruction Measurements Multiple series Slice-sel. IR 200 ms 80 deg Strong Short term Real Each measurement Resolution Base resolution 28 Phase resolution 00 % Phase partial Fourier Trajectory Cartesian Interpolation PAT mode Matrix Coil Mode Image Filter Distortion Corr. Prescan rmalize rmalize Auto (CP) Raw filter Elliptical filter Geometry Multi-slice mode Series Special sat. System Body HEP HEA Positioning mode MSMA Sagittal Coronal Save uncombined Coil Combine Mode Auto Coil Select REF H 0 mm S - C - T Adaptive Combine Default Shim mode Adjust with body coil Confirm freq. adjustment Assume Silicone Ref. amplitude H Adjustment Tolerance Adjust volume Position Physio st Signal/Mode Tune up 337.66 V Auto Isocenter 0.00 deg 350 mm 263 mm 350 mm Dark blood Resp. control Inline Subtract Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag MIP-Cor MIP-Tra MIP-Time Save original images Sequence Introduction Dimension 2D Compensate T2 decay Reduce Motion Sens. Contrasts Bandwidth 30 Hz/Px Flow comp. Allowed delay 0 s Echo spacing.7 ms /+

SIEMENS MAGNETOM TrioTim syngo MR B5 Define Turbo factor Turbo factor 5 Echo trains per slice 7 RF pulse type rmal Gradient mode Fast 2/+

SIEMENS MAGNETOM TrioTim syngo MR B5 \\USER\INVESTIGATORS\HST_583\Physics2\se_mc TA: 9:42 PAT: Voxel size:.. 5.0 mm Rel. SNR:.00 SIEMENS: se_mc Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slice group Slices Dist. factor 00 % Position R0.7 A0.8 H2.2 T > C-0.3 Phase enc. dir. 0.00 deg Phase oversampling 0 % FoV read 220 mm FoV phase 00.0 % Slice thickness 5.0 mm TR 4000 ms TE 4.3 ms TE 2 28.6 ms TE 3 42.9 ms TE 4 57.2 ms TE 5 7.5 ms TE 6 85.8 ms TE 7 00. ms TE 8 4.4 ms Averages Concatenations Filter Raw filter Coil elements HEA;HEP Contrast MTC Magn. preparation Flip angle Fat suppr. Fat sat. mode Water suppr. Averaging mode Reconstruction Measurements Multiple series 80 deg Strong Resolution Base resolution 92 Phase resolution 00 % Phase partial Fourier 6/8 Interpolation PAT mode Matrix Coil Mode Image Filter Short term Magnitude Each measurement Auto (CP) Distortion Corr. Prescan rmalize rmalize Raw filter Intensity Weak Slope 25 Elliptical filter Geometry Multi-slice mode Series Special sat. System Body HEP HEA Positioning mode MSMA Sagittal Coronal Save uncombined Coil Combine Mode Auto Coil Select REF H 0 mm S - C - T Adaptive Combine Default Shim mode Adjust with body coil Confirm freq. adjustment Assume Silicone Ref. amplitude H Adjustment Tolerance Adjust volume Position Physio st Signal/Mode Tune up 337.66 V Auto Isocenter 0.00 deg 350 mm 263 mm 350 mm Dark blood Inline Subtract Liver registration Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag MIP-Cor MIP-Tra MIP-Time Save original images Sequence Introduction Contrasts Bandwidth Allowed delay RF pulse type 3/+ 8 202 Hz/Px 0 s rmal

SIEMENS MAGNETOM TrioTim syngo MR B5 Gradient mode Fast 4/+

SIEMENS MAGNETOM TrioTim syngo MR B5 \\USER\INVESTIGATORS\HST_583\Physics2\T2star_8echos TA: 0: PAT: Voxel size: 2.0 2.0 5.0 mm Rel. SNR:.00 SIEMENS: gre Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slice group Slices Dist. factor 20 % Position R0.7 A0.8 H2.2 T > C-0.3 Phase enc. dir. 0.00 deg Phase oversampling 0 % FoV read 256 mm FoV phase 00.0 % Slice thickness 5.0 mm TR 00 ms TE 6.00 ms TE 2 0.00 ms TE 3 5.00 ms TE 4 20.00 ms TE 5 30.00 ms TE 6 50.00 ms TE 7 70.00 ms TE 8 80.00 ms Averages Concatenations Filter Raw filter Coil elements HEA;HEP Contrast MTC Magn. preparation Flip angle Fat suppr. Water suppr. Averaging mode Reconstruction Measurements Multiple series 5 deg Resolution Base resolution 28 Phase resolution 00 % Phase partial Fourier 6/8 Interpolation PAT mode Matrix Coil Mode Image Filter Distortion Corr. Long term Magnitude Each measurement Auto (CP) Prescan rmalize rmalize Raw filter Intensity Weak Slope 25 Elliptical filter Geometry Multi-slice mode Series Sequential Saturation mode Special sat. Standard System Body HEP HEA Positioning mode MSMA Sagittal Coronal Save uncombined Coil Combine Mode Auto Coil Select REF H 0 mm S - C - T Adaptive Combine Default Shim mode Adjust with body coil Confirm freq. adjustment Assume Silicone Ref. amplitude H Adjustment Tolerance Adjust volume Position Physio st Signal/Mode Segments Tune up 337.66 V Auto Isocenter 0.00 deg 350 mm 263 mm 350 mm Dark blood Resp. control Inline Subtract Liver registration Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag MIP-Cor MIP-Tra MIP-Time Save original images 5/+ Wash - In Wash - Out TTP

SIEMENS MAGNETOM TrioTim syngo MR B5 PEI MIP - time Sequence Introduction Dimension 2D Phase stabilisation Asymmetric echo Contrasts 8 Bandwidth 300 Hz/Px Bandwidth 2 300 Hz/Px Bandwidth 3 300 Hz/Px Bandwidth 4 300 Hz/Px Bandwidth 5 300 Hz/Px Bandwidth 6 300 Hz/Px Bandwidth 7 300 Hz/Px Bandwidth 8 300 Hz/Px Flow comp. Flow comp. 2 Flow comp. 3 Flow comp. 4 Flow comp. 5 Flow comp. 6 Flow comp. 7 Flow comp. 8 Readout mode Bipolar Allowed delay 0 s RF pulse type Gradient mode Excitation RF spoiling rmal Fast Slice-sel. 6/+

SIEMENS MAGNETOM TrioTim syngo MR B5 \\USER\INVESTIGATORS\HST_583\Physics2\epi_esp730 TA: 2.0 s PAT: Voxel size: 3. 3. 3. mm Rel. SNR:.00 USER: ep2d_bold_mgh_pro_tb Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slice group Slices 9 Dist. factor 67 % Position R0.3 A.0 F2. T > C-0.4 Phase enc. dir. 0.34 deg Phase oversampling 0 % FoV read FoV phase 00.0 % Slice thickness 3.0 mm TR 2000 ms TE 30 ms Averages Concatenations Filter Coil elements HEA;HEP Contrast MTC Flip angle Fat suppr. Averaging mode Reconstruction Measurements Delay in TR Multiple series 90 deg Fat sat. Long term Magnitude 0 ms Resolution Base resolution 64 Phase resolution 00 % Phase partial Fourier Interpolation PAT mode Matrix Coil Mode Distortion Corr. Prescan rmalize Raw filter Elliptical filter Hamming Geometry Multi-slice mode Series Special sat. Auto (CP) System Body HEP HEA Positioning mode MSMA Sagittal Coronal Coil Combine Mode Auto Coil Select FIX H 0 mm S - C - T Sum of Squares Default Shim mode Adjust with body coil Confirm freq. adjustment Assume Silicone Ref. amplitude H Adjustment Tolerance Adjust volume Position Physio st Signal/Mode Standard 337.66 V Auto R0.3 A.0 F2. T > C-0.4 0.34 deg 45 mm BOLD GLM Statistics Dynamic t-maps Starting ignore meas 0 Ignore after transition 0 Model transition states Temp. highpass filter Threshold 4.00 Paradigm size Meas Baseline Motion correction Spatial filter Sequence Introduction Bandwidth Free echo spacing Echo spacing 7/+ 502 Hz/Px 0.73 ms EPI factor RF pulse type Gradient mode 64 rmal Fast Dummy Scans 0

SIEMENS MAGNETOM TrioTim syngo MR B5 \\USER\INVESTIGATORS\HST_583\Physics2\epi_esp460 TA: 2.0 s PAT: Voxel size: 3. 3. 3. mm Rel. SNR:.00 USER: ep2d_bold_mgh_pro_tb Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slice group Slices 9 Dist. factor 67 % Position R0.3 A.0 F2. T > C-2.5 Phase enc. dir. 0.34 deg Phase oversampling 0 % FoV read FoV phase 00.0 % Slice thickness 3.0 mm TR 2000 ms TE 30 ms Averages Concatenations Filter Coil elements HEA;HEP Contrast MTC Flip angle Fat suppr. Averaging mode Reconstruction Measurements Delay in TR Multiple series 90 deg Fat sat. Long term Magnitude 0 ms Resolution Base resolution 64 Phase resolution 00 % Phase partial Fourier Interpolation PAT mode Matrix Coil Mode Distortion Corr. Prescan rmalize Raw filter Elliptical filter Hamming Geometry Multi-slice mode Series Special sat. Auto (CP) System Body HEP HEA Positioning mode MSMA Sagittal Coronal Coil Combine Mode Auto Coil Select FIX H 0 mm S - C - T Sum of Squares Default Shim mode Adjust with body coil Confirm freq. adjustment Assume Silicone Ref. amplitude H Adjustment Tolerance Adjust volume Position Physio st Signal/Mode Standard 337.66 V Auto R0.3 A.0 F2. T > C-2.5 0.34 deg 45 mm BOLD GLM Statistics Dynamic t-maps Starting ignore meas 0 Ignore after transition 0 Model transition states Temp. highpass filter Threshold 4.00 Paradigm size Meas Baseline Motion correction Spatial filter Sequence Introduction Bandwidth Free echo spacing Echo spacing 8/+ 2520 Hz/Px 0.46 ms EPI factor RF pulse type Gradient mode 64 rmal Fast Dummy Scans 0

SIEMENS MAGNETOM TrioTim syngo MR B5 \\USER\INVESTIGATORS\HST_583\Physics2\epi_esp480_grappa2 TA: 8.0 s PAT: 2 Voxel size: 3. 3. 3. mm Rel. SNR:.00 USER: ep2d_bold_mgh_pro_tb Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slice group Slices 9 Dist. factor 67 % Position R0.3 A.0 F2. T > C-2.5 Phase enc. dir. 0.34 deg Phase oversampling 0 % FoV read FoV phase 00.0 % Slice thickness 3.0 mm TR 2000 ms TE 30 ms Averages Concatenations Filter Coil elements HEA;HEP Contrast MTC Flip angle Fat suppr. Averaging mode Reconstruction Measurements Delay in TR Multiple series 90 deg Fat sat. Long term Magnitude 0 ms Resolution Base resolution 64 Phase resolution 00 % Phase partial Fourier Interpolation PAT mode Accel. factor PE Ref. lines PE Matrix Coil Mode Reference scan mode Distortion Corr. Prescan rmalize Raw filter Elliptical filter Hamming Geometry Multi-slice mode GRAPPA 2 32 Auto (Triple) Separate Series Special sat. System Body HEP HEA Positioning mode MSMA Sagittal Coronal Coil Combine Mode Auto Coil Select FIX H 0 mm S - C - T Sum of Squares Default Shim mode Adjust with body coil Confirm freq. adjustment Assume Silicone Ref. amplitude H Adjustment Tolerance Adjust volume Position Physio st Signal/Mode Standard 337.66 V Auto R0.3 A.0 F2. T > C-2.5 0.34 deg 45 mm BOLD GLM Statistics Dynamic t-maps Starting ignore meas 0 Ignore after transition 0 Model transition states Temp. highpass filter Threshold 4.00 Paradigm size Meas Baseline Motion correction Spatial filter Sequence Introduction Bandwidth Free echo spacing Echo spacing 9/ 2520 Hz/Px 0.48 ms EPI factor RF pulse type Gradient mode 64 rmal Fast Dummy Scans 0