NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

Similar documents
NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

A CLOSER LOOK. Electronic Fail-Safe Series Direct Coupled Actuators. The Belimo Difference. Brushless DC Motor for Added Accuracy and Controllability

Minimum 360 in-lb torque - GK. Minimum 54 in-lb torque - NKQ. Minimum 101 lbf - AHQ. Electronic Fail-Safe Series Direct Coupled Actuators

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Power consumption In operation At rest For wire sizing

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Functional data Factory settings Variable Setting Torque Inhibiting torque

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data sheet. Technical data

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Overview of types. Technical data

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AF24-MFT (-S) US Proportional damper actuator, Spring Return Fail-Safe, Multi-Function Technology

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data sheets

s Spring return C / max C

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING CONTROL

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

ECON-ZIP-BASE. ZIP Economizer Base Module

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ECM3000. Control Motor

THERMOSTATS & CONTROLLERS

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Products no longer available

Compact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Fast Route to Reliable Energy Savings ZIP Economizer

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Control Motor ECM3000

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Brief description. Type overview

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Standard. Functions Functions MFT. Multi-Function Technology. Fully Customizable. Proportional Control. Pre-Set Configuration.

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Products no longer available

Linear Actuators (235N)

N20, N34 SERIES. NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR FLOATING / 2-POSITION CONTROL SPECIFICATIONS GENERAL FEATURES

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

N20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

Brief description. Type overview

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Rotary version, three-position control

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

N20010, N NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

ASI Systems ML5740A Series

clarity 3 VAV Programmable Controller

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

N0524/N1024, N POS/N POS

J3C-H20DPS 25Nm Smart Electric Actuator Type: J3C Model: H20DPS

FX Input/Output (I/O) Modules XM07 and XM14

N05010/N10010 NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING / 2-POSITION CONTROL SPECIFICATIONS

RA Electric Rotary Actuator 20 Nm to 60 Nm for butterfly valves

ASI Systems ML5720A Series

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

General-Purpose Photoelectric Sensor

I ntroduction. RA Fast Running Electric Actuator. Features and Benefits

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

Satellite INSTALLATION GUIDE

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

ML7421A,B Electric Linear Valve Actuators

VA-7700 Series. Electric Valve Actuators. Product Bulletin

Rotork Fairchild PAX1 Linear Actuator User s Manual

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

S05, S10, S20 Series Spring Return Direct Coupled Actuators

Absolute Encoders Multiturn

Installation, Operation and Maintenance Manual

Operating instructions. Standstill monitor A / / 2011

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

Air damper actuators

Transcription:

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V orque min. 54 in-lb for control damper surfaces up to 12 sq ft. Application For proportional modulation of dampers in HVAC systems. he NKQB24-1 and NKQX24-1 provide electrical power off operation for reliable fail-safe application. he actuator is mounted directly to a damper shaft up to 1.05 in diameter. A crank arm and several mounting brackets are available for applications where actuator cannot be direct coupled to the damper shaft. Operation he actuator is electronically protected against overload. he anti-rotation strap supplied with the actuator will prevent lateral movement. he NKQB24-1 and the NKQX24-1 provide 95 of rotation and a visual indicator shows the position of the actuator. When reaching the damper or actuator end position the actuator automatically stops. he gear can be manually disengaged by pressing the button located on the actuator cover. echnical Data Power supply Power consumption ransformer sizing Electrical connection Overload protection Operation range Y Input impedance Feedback output U NKQB24-1, NKQX24-1 24VAC ±20% 50/60Hz 24VDC ±10% 11W (3W) 22VA (class 2 power source) 18 GA plenum rated cable ½" conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] electronic throughout 0 to 95 rotation on/off 100kΩ (0.1 ma), 500Ω 1500Ω (PWM, on/off) 2 to 10VDC, 0.5mA max, VDC variable Angle of rotation max. 95, adjustable with mechanical stop electronically variable orque 54 in-lb [6 Nm] Direction of rotation reversible with switch Fail-safe position adjustable with dial or tool 0 to 100% in 10% increments Position indication refl ective visual indicator (snap-on) Manual override external push button Running time normal operation fail-safe 4 seconds (default), variable 4 to 16 seconds 4 seconds Humidity 5 to 95% RH non-condensing (EN 60730-1) Ambient temperature Storage temperature -22 F to +122 F [-30 C to +50 C] -40 F to +176 F [-40 C to +80 C] Housing NEMA2, IP54, UL enclosure type 2 Housing material UL94-5VA Agency list culus acc. to UL 60730-1A/-2-14 CAN/CSA E60730-1:02 CE acc. to 2004/108/EEC and 2006/95/EC Noise level < 60dB(A) Servicing maintenance free Quality standard ISO 9001 Weight 2.4 lbs [1.10 kg] he NKQB24-1 and NKQX24-1 actuators use a brushless DC motor controlled by an Application Specifi c Integrated Circuit (ASIC). he ASIC monitors and controls the actuators rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in a holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (inches [mm]) 2.05 [52] 1.18 [30] 5.47 [139] 6.30 [160] 1.61 [41] 3.15 [80] 3.86 [98] D321 161

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V Accessories K-AM25 ¾" [20mm] Shaft Clamp ZG-102 Multiple Actuator Mounting Bracket ZG-NMA Crank arm Adaptor Kit ZG-JSA (-1,2,3) Jackshaft Adaptors for Hollow Jackshafts ZS-100 Weather Shield - Steel ZS-150 Weather Shield - Polycarbonate ZS-260 Explosion Proof Housing ZS-300 (-1) (-5) NEMA 4X Housing ool-06 8 and 10 mm Wrench PS-100 Actuator Power Supply Simulator S1A, S2A Auxiliary Switch(es) P370 Shaft Mount Auxiliary Switch P A Feedback Potentiometers ZG-X40 ransformer Note: When using NKQB24-3 and NKQX24-3 actuators, only use accessories listed on this page. Wiring Diagrams 1 Provide overload protection and disconnect as required. 2 CAUION Equipment Damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. Position feedback cannot be used with riac sink controller. 4 he actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) 5 or the Common (sink) 24 VAC line. Contact closures A & B also can be triacs. 8 A & B should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator 9 must be connected to the hot connection of the controller. ypical Specifi cation On/off control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to shaft up to 1.05" diameter. Actuators shall have Brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be culus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. Meets UL requirements without the need of an electrical ground connection. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W399 no_org On/Off control 162

NKQB24-SR, NKQX24-SR Proportional Control, Fail-Safe, Operation, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20mA orque min. 54 in-lb for control damper surfaces up to 12 sq ft. Application For proportional modulation of dampers in HVAC systems. he NKQB24-SR and NKQX24-SR provide electrical power off operation for reliable fail-safe application. he actuator is mounted directly to a damper shaft up to 1.05 in diameter by a universal clamp. A crank arm and several mounting brackets are available for applications where actuator cannot be direct coupled to the damper shaft. he actuator operates in response to a 2 to 10 VDC, or with the addition of a 500 Ω resistor, a 4 to 20mA control input from an electronic controller or positioner. A 2 to 10 VDC feedback signal is provided for position indication or master-slave applications. Operation he actuator is electronically protected against overload. he anti-rotation strap supplied with the actuator will prevent lateral movement. echnical Data NKQB24-SR, NKQX24-SR Power supply 24VAC ±20% 50/60Hz 24VDC ±10% Power consumption 11W (3W) ransformer sizing 22VA (class 2 power source) Electrical connection 18 GA plenum rated cable ½" conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload protection electronic throughout 0 to 95 rotation Operation range Y 2 to 10 VDC, 4 to 20mA (default) Input impedance 100kΩ (0.1 ma), 500Ω Feedback output U 2 to 10VDC, 0.5mA max, VDC variable Angle of rotation max. 95, adjustable with mechanical stop electronically variable orque 54 in-lb [6 Nm] Direction of rotation reversible with switch Fail-safe position adjustable with dial or tool 0 to 100% in 10% increments Position indication refl ective visual indicator (snap-on) Manual override external push button Running time normal operation fail-safe 4 seconds (default), variable 4 to 16 seconds 4 seconds Humidity 5 to 95% RH non-condensing (EN 60730-1) Ambient temperature Storage temperature -22 F to +122 F [-30 C to +50 C] -40 F to +176 F [-40 C to +80 C] Housing NEMA2, IP54, UL enclosure type 2 Housing material Agency list Noise level Servicing UL94-5VA culus acc. to UL 60730-1A/-2-14 CAN/CSA E60730-1:02 CE acc. to 2004/108/EEC and 2006/95/EC 60dB(A) maintenance free Quality standard ISO 9001 Weight 2.40 lbs [1.1 kg] he NKQB24-SR and NKQX24-SR provide 95 of rotation and a visual indicator shows the position of the actuator. When reaching the damper or actuator end position the actuator automatically stops. he gear can be manually disengaged by pressing the black button located on the actuator cover. he NKQB24-SR and NKQX24-SR actuators use a brushless DC motor, which is controlled by an Application Specifi c Integrated Circuit (ASIC). he ASIC monitors and controls the actuators rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in a holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (inches [mm]) 2.05 [52] 1.18 [30] 5.47 [139] 6.30 [160] 1.61 [41] 3.15 [80] 3.86 [98] D321 163

NKQB24-SR, NKQX24-SR Proportional Control, Fail-Safe, Operation, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20mA Accessories K-AM25 ¾" [20mm] Shaft Clamp ZG-102 Multiple Actuator Mounting Bracket ZG-NMA Crank arm Adaptor Kit ZG-JSA (-1,2,3) Jackshaft Adaptors for Hollow Jackshafts ZS-100 Weather Shield - Steel ZS-150 Weather Shield - Polycarbonate ZS-260 Explosion Proof Housing ZS-300 (-1) (-5) NEMA 4X Housing ool-06 8 and 10 mm Wrench PS-100 Actuator Power Supply Simulator S1A, S2A Auxiliary Switch(es) P370 Shaft Mount Auxiliary Switch Note: When using NKQB24-SR and NKQX24-SR actuators, only use accessories listed on this page. ypical Specifi cation Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to shaft up to 1.05" diameter. Actuators must provide proportional damper control response to a 2 to 10 VDC or, with the addition of a 500Ω resistor, a 4 to 20 ma control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be culus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. Wiring Diagrams 1 Provide overload protection and disconnect as required. 2 CAUION Equipment Damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. Meets UL requirements without the need of an electrical ground connection. he ZG-R01 500 Ω resistor may be used. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Electrical Installation Wiring diagram Note Connect via safety isolation transformer.! Parallel connection of other actuators possible. Note performance data for supply. ~ + 1 2 3 5 Y U DC 0... 10 V DC 2... 10 V Cable lengths Note When several actuators are connected in parallel, the maximum cable length must be divided by the number of actuators. ~ Y U 1 2 3 5 N L AC 230 V AC 24 V Y L 2 L 1 U C L tot A C VDC/4-20 ma L 1 Note here are no special restrictions on installation if the supply and data cable are routed separately. 1 2 3 5 A Cable colors: 1 = black 2 = red 3 = white 5 = orange A = Actuator C = Control unit L1 = Belimo connecting cable, 1 m (4 x 0.75 mm 2 ) L2 = Customer cable Ltot = Maximum cable length Cross section L2 Max. cable length Example for DC Ltot t = L1 + L2 / AC DC 0.75 mm 2 <30 m <5 m 1 m (L1) + 4 m (L 2) 1.00 mm 2 <40 m <8 m 1 m (L1) + 7 m (L 2) 1.50 mm 2 <70 m <12 m 1 m (L1) + 11 m (L 2) 2.50 mm 2 <100 m <20 m 1 m (L1) + 19 m (L 2) ~ A = Actuator C = Control unit L1 = Belimo connecting cable, 1 m (4 x 0.75 mmm 2 ) 164

NKQX24-MF Proportional Control, Fail-Safe, Operation, Direct Coupled, 24V, Multi-Function echnology orque min. 54 in-lb for control damper surfaces up to 12 sq ft. Application For proportional modulation of dampers in HVAC systems. he NKQX24-MF provides electrical power off operation for reliable fail-safe application. he actuator is mounted directly to a damper shaft up to 1.05 in diameter by a universal clamp. A crank arm and several mounting brackets are available for applications where actuator cannot be direct coupled to the damper shaft. he default parameters for 2 to 10 VDC applications of the NKQX24-MF actuator are assigned during manufacturing. If necessary, custom versions of the actuator can be ordered. he parameters can be changed by: pre set or custom confi gurations provided by Belimo or on-site using the PC-ool software. Operation he actuator is electronically protected against overload. he anti-rotation strap supplied with the actuator will prevent lateral movement. echnical Data NKQX24-MF Power supply 24VAC ±20% 50/60Hz 24VDC ±10% Power consumption 11W (3W) ransformer sizing 22VA (class 2 power source) Electrical connection 18 GA plenum rated cable ½" conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload protection electronic throughout 0 to 95 rotation Operation range Y 2 to 10 VDC, 4 to 20mA (default), variable VDC Input impedance 100kΩ (0.1 ma), 500Ω Feedback output U 2 to 10VDC, 0.5mA max, VDC variable Angle of rotation max. 95, adjustable with mechanical stop electronically variable orque 54 in-lb [6 Nm] Direction of rotation reversible with switch Fail-safe position adjustable with dial or tool 0 to 100% in 10% increments Position indication refl ective visual indicator (snap-on) Manual override external push button Running ime normal operation fail-safe 4 seconds (default), variable 4 to 16 seconds 4 seconds Humidity 5 to 95% RH non-condensing (EN 60730-1) Ambient temperature Storage temperature -22 F to +122 F [-30 C to +50 C] -40 F to +176 F [-40 C to +80 C] Housing NEMA2, IP54, UL enclosure type 2 Housing material Agency list UL94-5VA Noise level 60dB(A) Servicing maintenance free Quality standard ISO 9001 Weight 2.40 lbs [1.1 kg] culus acc. to UL 60730-1A/-2-14 CAN/CSA E60730-1:02 CE acc. to 2004/108/EEC and 2006/95/EC he NKQX24-MF provides 95 of rotation and a visual indicator shows the position of the actuator. When reaching the damper or actuator end position the actuator automatically stops. he gear can be manually disengaged by pressing the button located on the actuator cover. he NKQX24-MF actuator uses a brushless DC motor, which is controlled by an Application Specifi c Integrated Circuit (ASIC). he ASIC monitors and controls the actuators rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in a holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. When combining signal and power cable together, see important electrical installation diagram on page 164. Dimensions (inches [mm]) 2.05 [52] 1.18 [30] 5.47 [139] 6.30 [160] 1.61 [41] 3.15 [80] 3.86 [98] D321 165

NKQX24-MF Proportional Control, Fail-Safe, Operation, Direct Coupled, 24V, Multi-Function echnology Accessories K-AM25 ¾" [20mm] Shaft Clamp ZG-102 Multiple Actuator Mounting Bracket ZG-NMA Crank arm Adaptor Kit ZG-JSA (-1,2,3) Jackshaft Adaptors for Hollow Jackshafts ZS-100 Weather Shield - Steel ZS-150 Weather Shield - Polycarbonate ZS-260 Explosion Proof Housing ZS-300 (-1) (-5) NEMA 4X Housing ool-06 8 and 10 mm Wrench PS-100 Actuator Power Supply Simulator S1A, S2A Auxiliary Switch(es) P370 Shaft Mount Auxiliary Switch P A Feedback Potentiometers SGA24 Min positioners in NEMA 4 Housing SGF24 Min positioners for fl ush panel mounting ADS-100 Analog to Digital Switch ZG-R01 Resistor for 4 to 20 ma Conversion NSV24 US Battery Back-Up Module ZG-X40 ransformer Note: When using NKQX24-MF actuators, only use accessories listed on this page. he ZG-R01 500 Ω resistor may be used. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. VDC/4-20 ma ypical Specifi cation Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to shaft up to 1.05" diameter. Actuators must provide proportional damper control response to a 2 to 10 VDC or, with the addition of a 500Ω resistor, a 4 to 20 ma control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be culus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. Wiring Diagrams 1 Provide overload protection and disconnect as required. 2 CAUION Equipment Damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. Position feedback cannot be used with riac sink controller. 4 he actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) 5 or the Common (sink) 24 VAC line. Contact closures A & B also can be triacs. 8 A & B should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator 9 must be connected to the hot connection of the controller. PWM On/Off control Meets UL requirements without the need of an electrical ground connection. Floating Point control 166