HTTL Speed Feedback Communications Option

Similar documents
Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

8902/E1 Sin/Cos Speed Feedback Option

8902/E1 Sin/Cos Speed Feedback Option

8903/AI High Resolution Analogue Input Option. 8903/EP Encoder Option

8902/RE Resolver Speed Feedback Option

890 Quickstart Manual

AC10 series NEW FEATURES FRAME 1-5. HA502319U100 Issue 5 Product Manual ENGINEERING YOUR SUCCESS.

8903/PB Profibus Communications Option

8903/PB Profibus Communications Interface

8902/EQ. HTTL Speed Feedback Option. HA469255U001 Issue 4 Technical Manual. electromechanical

890 Quickstart Manual

Resolver to Digital Expansion Board

V E1B Snap-in I/O Module

8903/FA FireWire IEEE 1394a Communications Interface

Operating instructions. Speed monitor D / / 2014

Operating instructions. Standstill monitor A / / 2011

SMVector Additional I/O Module Installation and Operation Manual

V E2B Snap-in I/O Module

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

690+ Series Frequency Inverter

Siemens APOGEE P1 Communications Option

V E2B Snap-in I/O Module

User s Manual Pulse Encoder Interface Module OTAC-01

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

V E1B Snap-in I/O Module

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Installation, Operation and Maintenance Manual

690+ Series AC Drive Frame B, C, D, E & F

V E5B Snap-in I/O Module

This manual was downloaded on (0) TS8000. Firewire Option 8000/FA/00 HA Issue 1

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Operating instructions. Switching amplifier DN0210 DN / / 2015

PV Rapid Shutdown device

PRO-1250D CT MID DIN rail three phase four wire energy meter.

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Model 7705 Control Module

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

690+ Series AC Drive Frame B, C, D, E & F

5401 and 5402 Digital I/O Modules

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

PCI 2 Axis Servo Card

270 MHz Control Modules

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

5504 Thermocouple Analog Input Module

Master Pulse Reference/ Isolated Pulse Follower Expansion Board

Digital ac/dc (24V) Input Module

Vision OPLC V TR6/V350-J-TR6

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EX-RC1 Remote I/O Adapter

High Speed Remote I/O Module

V E62B Snap-in I/O Module

Johnson Controls Metasys N2 Communications Interface

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

ENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS

Profibus DP Expansion Board

MDM 011-Z1 Regen Resistor

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

P216 Series Condenser Fan Speed Controller

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

Kinetix 6000 Axis Module and Shunt Module

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Siemens Industrial s

P216. Condenser fan speed controller. Product bulletin. Features

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

CPCI-PS24 24V-Power Supply

P3-SCM. General Specifications

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

MAXIMA+ Series Rotary Level Indicator

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

OPLC Installation Guide

Electric Actuators and Control Systems. Established Leaders in Valve Actuation AD-8140 & AD Instruction Manual. Publication P971E Issue 08/09

PCI 2 Axis Servo Card

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Hybrid AC Driver [GCNC-1110]

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Profibus DP Expansion Board

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

700 Series 200 Amp Clamp Meters

Instruction manual. Output chokes 690V. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

EOS-6000 Series Optical A/B Switch User Manual DC Version

Masterswitch 25kW 230V-125A Automatic AC transfer switch

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

MC 11 EB-2 Power supply cabinet with external bus, AC version

Installation Instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Two Module Development Kit Installation and User Instructions For Model No. ED-GV15/30

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Transcription:

HTTL Speed Feedback Communications Option Technical Manual HA467152U001 Issue 7 Compatible with Version 1.x Software - 690+ Compatible with Version 5.x Software - 605C Copyright 2010 Parker Hannifin Ltd All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any form or by any means to persons not employed by a Parker Hannifin Ltd., Automation Group, SSD Drives Europe without written permission from Parker Hannifin Ltd., Automation Group, SSD Drives Europe. Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Parker Hannifin ltd., Automation Group, SSD Drives Europe cannot accept responsibility for damage, injury, or expenses resulting there from. WARRANTY Parker Hannifin Ltd., Automation Group, SSD Drives Europe, warrants the goods against defects in design, materials and workmanship for the period of 24 months from the date of manufacture, or 12 months from the date of delivery (whichever is the longer period) on the terms detailed in Parker SSD Drives Standard Conditions of Sale IA500504. Parker Hannifin Ltd., Automation Group, SSD Drives Europe reserves the right to change the content and product specification without notice.

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems Cont.2

Safety Information! Requirements IMPORTANT: Please read this information BEFORE installing the equipment. Intended Users This manual is to be made available to all persons who are required to install, configure or service equipment described herein, or any other associated operation. The information given is intended to highlight safety issues, EMC considerations, and to enable the user to obtain maximum benefit from the equipment. Complete the following table for future reference detailing how the unit is to be installed and used. Model Number (see product label) INSTALLATION DETAILS Where installed (for your own information) Unit used as a: (refer to Certification for the Inverter) Component Relevant Apparatus Unit fitted: Wall-mounted Enclosure Application Area The equipment described is intended for industrial motor speed control utilising DC motors, AC induction or AC synchronous machines Personnel Installation, operation and maintenance of the equipment should be carried out by qualified personnel. A qualified person is someone who is technically competent and familiar with all safety information and established safety practices; with the installation process, operation and maintenance of this equipment; and with all the hazards involved. Product Warnings Caution Risk of electric shock Caution Refer to documentation Earth/Ground Protective Conductor Terminal Cont.3

Hazards DANGER! - Ignoring the following may result in injury 1. This equipment can endanger life by exposure to rotating machinery and high voltages. 2. The equipment must be permanently earthed due to the high earth leakage current, and the drive motor must be connected to an appropriate safety earth. 3. Ensure all incoming supplies are isolated before working on the equipment. Be aware that there may be more than one supply connection to the drive. 4. There may still be dangerous voltages present at power terminals (motor output, supply input phases, DC bus and the brake, where fitted) when the motor is at standstill or is stopped. Cont.4 Safety Information! 5. For measurements use only a meter to IEC 61010 (CAT III or higher). Always begin using the highest range. CAT I and CAT II meters must not be used on this product. 6. Allow at least 5 minutes for the drive's capacitors to discharge to safe voltage levels (<50V). Use the specified meter capable of measuring up to 1000V dc & ac rms to confirm that less than 50V is present between all power terminals and earth. 7. Unless otherwise stated, this product must NOT be dismantled. In the event of a fault the drive must be returned. Refer to "Routine Maintenance and Repair". WARNING! - Ignoring the following may result in injury or damage to equipment SAFETY Where there is conflict between EMC and Safety requirements, personnel safety shall always take precedence. Never perform high voltage resistance checks on the wiring without first disconnecting the drive from the circuit being tested. Whilst ensuring ventilation is sufficient, provide guarding and /or additional safety systems to prevent injury or damage to equipment. When replacing a drive in an application and before returning to use, it is essential that all user defined parameters for the product s operation are correctly installed. All control and signal terminals are SELV, i.e. protected by double insulation. Ensure all external wiring is rated for the highest system voltage. Thermal sensors contained within the motor must have at least basic insulation. All exposed metalwork in the Inverter is protected by basic insulation and bonded to a safety earth. RCDs are not recommended for use with this product but, where their use is mandatory, only Type B RCDs should be used. EMC In a domestic environment this product may cause radio This is a product of the restricted sales distribution interference in which case supplementary mitigation class according to IEC 61800-3. It is designated as measures may be required. professional equipment as defined in This equipment contains electrostatic discharge (ESD) EN61000-3-2. Permission of the supply authority sensitive parts. Observe static control precautions shall be obtained before connection to the low when handling, installing and servicing this product. voltage supply. CAUTION! APPLICATION RISK The specifications, processes and circuitry described herein are for guidance only and may need to be adapted to the user s specific application. We can not guarantee the suitability of the equipment described in this Manual for individual applications. RISK ASSESSMENT Under fault conditions, power loss or unintended operating conditions, the drive may not operate as intended. In particular: Stored energy might not discharge to safe levels as The motor's direction of rotation might not be controlled quickly as suggested, and can still be present even The motor speed might not be controlled though the drive appears to be switched off The motor might be energised A drive is a component within a drive system that may influence its operation or effects under a fault condition. Consideration must be given to: Stored energy Supply disconnects Sequencing logic Unintended operation

Contents Contents Page HTTL SPEED FEEDBACK OPTION 1 Description... 1 Features... 1 Used On... 1 Specifications... 1 Recommended Spare Parts... 1 Installation... 2 Wiring the System : 605C, 690+ Frames C-K... 2 DIP Switch Settings... 3 Terminal Block (TB1) Connections... 3 Understanding the LED Indications... 4 Wiring the System : 690+ Frame B... 4 DIP Switch Settings... 5 Terminal Block (TB1) Connections... 5 Initial Set-up... 6 Configuring the 605C Inverter... 6 Configuring the 690+ Inverter... 8 Parker SSD Drives Approved Encoders... 9 Cont.5

1 HTTL SPEED FEEDBACK OPTION Description The HTTL Speed Feedback Option allows incremental encoders to be connected directly to the motor controller to provide highly accurate speed feedback measurement. Features The option has the following features: Contains up to four optically isolated differential inputs on channels A, B, M and H Decoding logic to interface the encoder to the microprocessor Supplies variable voltage, isolated encoder power supply Used On The HTTL Speed Feedback Option is provided in two forms: 1. Technology Box -for use with the 605C Inverter and 690+ Frames C-K Inverter 2. Speed Feedback Board - for use with the 690+ Frame B Specifications Technology Box Speed Feedback Board Maximum Pulse Rate 250kHz 250kHz Receiver Current 10mA per channel 10mA per channel Input Format Two channels in quadrature, clock/dir or clock only Two channels in quadrature, clock/dir or clock only Phase Displacement >1μs >1μs Input Voltage Encoder Supply 10-30V differential recommended, or singleended Maximum load = 200mA or 2W, whichever is smaller. Voltage adjustable approximately 10-20V by firmware 10-30V differential recommended, or singleended Maximum load = 200mA or 2W, whichever is smaller. Voltage adjustable approximately 10-20V by firmware Terminal Wire Size (maximum) 16 AWG 16 AWG Terminal Tightening Torque 0.4Nm (3.5 pound-inches) 0.2Nm (1.75 pound-inches) Recommended Spare Parts We recommend that you keep one option as a spare to reduce down-time.

2 Installation WARNING! Disconnect all sources of power before attempting installation. Injury or death could result from unintended actuation of controlled equipment. Caution This option contains ESD (Electrostatic Discharge) sensitive parts. Observe static control precautions when handling, installing and servicing this option. Wiring the System : 605C, 690+ Frames C-K earthing screw Figure 1 Installing the Option (605C illustrated) 1. Unpack and handle the Option using correct static safety procedures. 2. Remove the inverter terminal cover and securing screws. 3. Carefully plug the Option into the left-hand port (as illustrated above) ensuring correct alignment of the connector and tighten the earthing screw. You can operate the Inverter with the Speed Feedback and/or a Communications Technology Box, but you cannot use two options of the same kind.

DIP Switch Settings The DIP switch can be seen through the casing of the HTTL Speed Feedback Technology Box. The switch settings control the following inputs: ON DIP SWITCH 1 2 3 4 OFF 3 Input Threshold Switch Number 1 2 3 4 DIP Input Controlled H A B M 3V±1 On On On On 8V±1 Off Off Off Off TB1 Usually the switches will be set to give a threshold of 3V when using a differential encoder, and to 8V when using a single-ended encoder. (Factory default is with switches 1 & 2 set in the ON position - 3V). Terminal Block (TB1) Connections TB1 - TECHNOLOGY BOX supply H /H A /A B /B M /M + - GND 1 2 3 4 5 6 7 8 9 10 11 TB1 - TECHNOLOGY BOX supply H /H A /A B /B M /M + - GND 1 2 3 4 5 6 7 8 9 10 11 H /H A /A B /B M /M + - supply ENCODER 0V H A B M + - supply ENCODER 0V Figure 3 Differential Encoder Outputs Figure 2 Single-Ended Encoder Outputs For correct operation, A, /A, B and /B must be connected as shown. If any is left unconnected, the HTTL speed feedback technology box will not operate. Note: The M and H inputs are not normally connected - these are for use with future versions of drive software. M: For connection to the once-per-revolution marker output from the encoder to verify correct operation of the encoder. H: For where the encoder has provision for a `health output. Take special care wiring the encoders to the option due to the low level of the signals. All wiring to the should be made in screened cable. Use cable with an overall screen and a screen over each individual pair. To ensure compliance with the EMC Directive the overall cable screen should be connected to the encoder body and to the terminal block, pin 11. Recommended cable (pairs individually screened): Belden equivalent 8777 Parker SSD Drives Part Number CM052666

4 Understanding the LED Indications Module LED In normal operation this LED will be ON. If it fails to come on within 10 seconds after powerup check that the Technology Box is correctly installed. Encoder LED This will indicate the status of the Health inputs, pins 1 and 2 on future versions of drive software. If the voltage across pins 1 and 2 exceeds the Minimum Differential Input Voltage set by the DIP switch, the Encoder LED will be ON (pin 1 is positive with respect to pin 2). Wiring the System : 690+ Frame B cable tie loop Speed Feedback Board Comms Technology Option Figure 4 The HTTL Speed Feedback Board fitted to 690+ Frame B The option is factory-fitted using correct static safety procedures. The cable tie loop is used to secure the connecting cable so that it doesn t obstruct the LED light pipes used by the Comms Technology Option.

5 DIP Switch Settings The DIP switch settings control the following inputs: Input Threshold Switch Number 1 2 HTTL Speed Feedback Option Input Controlled A B 3V±1 On On 8V±1 Off Off 1 6 TB1 ON DIP Usually the switches will be set to give a threshold of 3V when using a differential encoder (as shown), and to 8V when using a single-ended encoder. (Factory default is with switches 1 & 2 set in the ON position - 3V). Terminal Block (TB1) Connections ON DIP SWITCH 1 2 3 4 OFF POSITIONS 3 & 4 ARE NOT USED TB1 - TECHNOLOGY OPTION supply A /A B /B + - 1 2 3 4 5 6 cable clamp GND TB1 - TECHNOLOGY OPTION supply A /A B /B + - 1 2 3 4 5 6 cable clamp GND + - supply A /A B /B ENCODER 0V + - supply A ENCODER B 0V Figure 5 Differential Encoder Outputs Figure 6 Single-Ended Encoder Outputs Note: The GND connection shown above is the screen connection, some encoder manufacturers use a different terminology. For correct operation, A, /A, B and /B must be connected as shown. If any is left unconnected, the HTTL speed feedback technology box will not operate. Take special care wiring the encoders to the option due to the low level of the signals. All wiring to the Speed Feedback option should be made in screened cable. Preferably, use cable with an overall screen and a screen over each individual pair. To ensure compliance with the EMC Directive the overall cable screen should be connected to the encoder body and to the cable clamp. Recommended cable: Belden equivalent 8164 - overall screen and pairs individually screened Belden equivalent 8777 - pairs individually screened, ParkerSSD Drives Part No CM052666

6 Initial Set-up MMI Menu Map 1 SETUP PARAMETERS 2 FUNCTION BLOCKS 3 INPUTS & OUTPUTS 4 ENCODER Configuring the 605C Inverter ENCODER MODE ENCODER LINES ENCODER INVERT ENCODER RESET ENCODER SUPPLY ENCODER SPEED ENCODER SPEED ENCODER SPEED ENCODER POSITION Using the Operator Station (MMI) or other suitable PC programming tool, the ENCODER function block requires configuring before the HTTL option can be used. DSE Lite is Parker SSD Drives Windows-based block programming software. Parameter Descriptions ENCODER SPEED Hz [568] 0.0 Hz SPEED RPM [569] 0 n/min SPEED % [749] 0.00% POSITION [748] 0 QUADRATURE [565] MODE 1000 [566] LINES FALSE [567] INVERT FALSE [747] RESET 10.0V [761] SUPPLY MODE Range: Enumerated, see below This must be set to QUADRATURE, CLOCK/DIR or CLOCK. A wrt /A B wrt /B Quadrature direction = forward direction = reverse (assumes ENCODER INVERT is FALSE) A wrt /A B wrt /B Clock/Dir direction = forward direction = reverse (assumes ENCODER INVERT is FALSE) Clock A wrt /A B wrt /B (ignored) direction = forward direction = forward (assumes ENCODER INVERT is FALSE) Enumerated Value : Encoder Mode 0 : QUADRATURE 1 : CLOCK/DIR 2 : CLOCK

LINES Range: 1 to 10000 The number of lines must be set to match the type of encoder being used. Incorrect setting of this parameter will result in an erroneous speed measurement. INVERT Range: FALSE / TRUE When TRUE, changes the sign of the measured speed and the direction of the position count. 7 RESET When TRUE, the POSITION output is set (and held) at zero. Range: FALSE / TRUE SUPPLY Range: 10.0 to 20.0V Approximate encoder supply voltage. SPEED Hz Speed feedback in Hz. SPEED RPM Speed feedback in RPM. SPEED % Speed feedback as a percentage of MAXIMUM SPEED. Range: xxx.xhz Range: xxxxx n/min Range: xxx.xx% POSITION Range: (increments @ 4 x line rate, i.e. 1 revolution = 4000 for a 1000 line encoder) Number of encoder counts from when RESET was set to FALSE. The value will increment or decrement depending on the direction the encoder is rotated. The value will wrap around between 32767 and -32768.

8 MMI Menu Map 1 SETUP 2 MOTOR CONTROL 3 FEEDBACKS ENCODER SUPPLY ENCODER LINES ENCODER INVERT QUADRATIC TORQUE DC LINK VOLTS TERMINAL VOLTS SPEED FBK RPM SPEED FBK HZ SPEED FBK % ENCODER COUNT TORQUE FEEDBACK FIELD FEEDBACK MOTOR CURRENT % MOTOR CURRENT A Configuring the 690+ Inverter Using the Operator Station (MMI) or other suitable PC programming tool, this function block requires configuring before the HTTL option can be used. DSE Lite is SSD Drives Windows-based block programming software. Ranges for some outputs are given as.xx %, for example, indicating an indeterminate integer for the value, to two decimal places. Note that only parameters relevant to the Encoder are described below. Parameter Descriptions Feedbacks DC LINK VOLTS [ 75] 0 V TERMINAL VOLTS [1020] 0 V SPEED FEEDBACK [569] 0.00 rpm RPM SPEED FEEDBACK HZ [568] 0.00 Hz SPEED FEEDBACK % [749] 0.00 % ENCODER COUNT [1016] 0 TORQUE FBK [ 70] 0.00 % FIELD FBK [ 73] 0.00 % MOTOR CURRENT % [ 66] 0.00 % MOTOR CURRENT [ 67] 0.0 A 10.0 V [761] ENCODER SUPPLY ** 2048 [566] ENCODER LINES FALSE [567] ENCODER INVERT FALSE [ 50] QUADRATIC TORQUE ENCODER SUPPLY Range: 10.0 to 20.0V Set this to the supply voltage required by the encoder. ENCODER LINES Range: 250 to 1000000 The number of lines must be set to match the type of encoder being used. Incorrect setting of this parameter will result in an erroneous speed measurement. ** Set to a value depending on the overall power build of the Inverter. ENCODER INVERT Range: FALSE/TRUE Used to match the encoder direction to the motor direction. When TRUE, it changes the sign of the measured speed and the direction of the position count. It is especially necessary to set up this parameter when in CLOSED-LOOP VEC mode, as the encoder direction must be correct for this mode to operate. SPEED FEEDBACK RPM The mechanical speed of the motor shaft in revolutions per minute. SPEED FEEDBACK HZ Range:.xx rpm Range:.xx Hz This parameter changes according to the CONTROL MODE (MOTOR DATA function block): In CLOSED-LOOP VEC mode, or SENSORLESS VEC mode, the parameter shows the mechanical speed of the motor shaft in revolutions per second. In VOLTS / Hz mode, the parameter shows the drive output frequency. SPEED FEEDBACK % Range:.xx % Shows the mechanical speed of the motor shaft as a percentage of the user maximum speed setting (MAX SPEED in the SETPOINT SCALE function block). ENCODER COUNT Range:. (increments/decrements @ 4 x line rate, i.e. 1 revolution = 4000 for a 1000 line encoder) This is a 16-bit register which is incremented or decremented by the pulses from the encoder. It is useful to check that the encoder is operating, and to measure the encoder lines, if this is not known. Rotate the motor shaft through 1 revolution and note the difference between readings at the start and finish. The difference should be 4 times the encoder lines. For greater accuracy, rotate the shaft through several revolutions. The direction of count is unaffected by ENCODER INVERT.

Parker SSD Drives Approved Encoders 9 Recommended Encoder (12mm bore) Alternative Encoders (20mm bore) Hengstler: Parker SSD Drives Part Number: Hengstler: Parker SSD Drives Part Number: RI 58TD//2048ED.37IF DD464475U012 RI 76TD/2048ED-4N20IF DD464475U020 Encoders are available from Hengstler in other accuracies such as 500 lines/rev or 2000 lines/rev to suit the application.

10